3Ø Electronic Energy Meters - DM 52 series Enables direct energy usage reading, no external multiplication factor required. Can be hooked on to an Energy Management System, SCADA, PLC, DCS. Technical Specifications Input (3 Phase 3 Wire / 4 Wire) : + V input overload withstanding Applications Features + True RMS + Low PT, CT burden + Accuracy class 1.0 IEC 61036 & Class 0.5 + Simultaneous sampling of Volts & Amps + Accurate on distorted waveforms Sealed dust-proof construction + Quick and easy installation + Reverse LED for trouble shooting + 3 phase 4 wire (& Single phase) - DM 5240 + 3 Phase 3 wire - DM 5230 + Industrial quality + Field settable standard full scale + Pulse output feature + Tamper proof cover option + Dimensions Bezel : 96 x 96 mm Depth : 80 mm behind Bezel +0.5 -0 x 92 -0 mm Panel cutout : 92+0.5 x 20 Times Rated Current 4kV Voltage + Electrical Panels + Test Benches + Wind Energy + Co-Generation + Genset Panels + Lab Equipment + Power Plants + All types of Industries + Load Centers 3kV 2kV 1kV .05 .5 x 12 1A x8 x6 x4 x2 5A 5 50 .5k 5k 1min 1 Time (mS) Nominal 10 100 1000 Time (Sec) Range Range Current 5 Amps 0.25 to 6.0 Amps 1 Amp 0.05 to 1.2 Amps Nominal Voltage 110 VLL 80 to 130 V 240 VLN 170 to 270 V 415 VLL 330 to 470 V Frequency Power Factor 0.5 PF Lag-Unity-0.8 PF Lead 50 Hz / 60 Hz + 5% + Auxiliary Supply : Nominal 110 V Range 80-150 V Nominal 240 V Range 170-300 V (45 to 65 Hz) + : 0.2 VA max. per phase (Volts/Amps Input) Burden 3 VA max. on Auxilia ry Supply + Display : 6 Digit Impulse Counter. Max counts 999999. Tamper proof, Non-resettable. Retains the last recorded reading even under power failure conditions. + Accuracy : Class 1.0 ; as per IEC 61036 Class 0.5 ; + (0.25 % of reading + 0.25 % of Full Scale) 1 2 3 4 5 6 Decimal Point 0.4 to Ö3 V Pri LL x A Pri 4.0 + Multiplying Factor: 0.01 Full Scale kW + 4.1 to 40 0.1 41 to 400 1 0.1 0.1 1 1 401 4,001 40,001 to to to 4000 40,000 4,00,000 10 100 1000 (Represented by decimal point) + Resolution : - Counter : kWh/ Count INTEG LED kWh/ Blink kWh/ Pulse Overflow Hours + Pulse Width + Contact Rating + Ambient + ISO 14001:2004 Certified ISO 9001:2000 Certified x 16 0.6kV - Pulse Output 9mm additional space on both side of the meter inside the Panel A input overload withstanding x 30 6kV/ 5kV Weight + Dimension + Depth + Panel Cut-out + Mounting + Warranty + 0.01 0.01 10 10 100 100 1000 1000 10 or 8 10 or 8 10 or 8 10 or 8 10 or 8 10 or 8 0.01 0.1 1 10 100 : 2,500 - 2 5 ,000 (at Full Load) : 500 mS + 50 mS : 24V DC, 100 mA Max : Temperature 0 - 50 C 0 Humidity < 95% Non-Condensing : 450 gms approx. : Bezel: 96 x 96 mm : 80 mm behind Bezel : (92 +0.5) x (92 +0.5) mm : Flush Mounting. : 1 Year from date of Invoice 1000 Know your DM 52 Multiplying Factor (MF) In the case of Direct Reading Meters, Multiplying Factor is the number by which Counter reading must be multiplied to get actual kWh consumed. The MF is indicated by decimal point of the Meter. In the case of 3 Phase 4 Wire Model DM 5240, calibrated for 415V/5A, the decimal point printed on the meter is 0.01. Each count on the Counter represents 1/100th of a kWh for direct input of 415V/5A. For the same meter when input is through a CT, depending on the CT Ratio an additional MF has to be applied by the user to get actual consumption. For example, for a CT Ratio of 100/5, the consumption is given by (Counter Reading) x 0.01 x 100/5 i.e, (Counter Reading) x 0.2. Thus, for a 500/5 CT, the Counter Reading directly gives the consumption. What do the POWER & INTEG LEDs on the front panel do ? POWER LED indicates presence of Auxiliary Power which is essential for the meter operation. INTEG LED indicates that integration of Energy is in progress. The LED Blink Rate is either 10 or 8 times that of the Counter update. Hence its resolution is 10 or 8 times that of the Counter and can be conveniently used for meter calibration. Overflow Hours? As the Counter accumulates kWh, it will eventually reach 999999 and then overflow to 000000. The duration it takes to overflow is approximately equal to (999999) / average kW which the meter senses. TAMPER PROOF COVER OPTION A Tamper Proof cover enables sealing of terminal block at the rear of the meter. This prevents tampering of connections. Pulse Output Feature Optically Isolated, Solid-state NO Contact gives digital pulse output to drive Remote Counter, PLC, DCS Station etc. for off line monitoring of Energy Data, on line control for Energy/Power/Process optimisation, correlating Energy Input to product output etc. Applications of pulse output feature are as shown below. Process Integration 1 4 VN CT 14 6 13 6 S2 ® Sl.No. S2 CT A3 A3 Sl.No. S1 7 4 PT S2 VN 12 PT S1 5 S2 11 3 V3 5 Feeder2 9 2 8 1 10 9 3 11 4 10 11 PT 2 12 5 6 13 CT 12 A3 Sl.No. 4 10 S1 PT 5 10 V3 A2 11 2 3 9 S1 V2 S2 A2 VN S1 S2 Sl.No. Presettable Counter 7 13 ® 12v 24v DC ® 14 8 9 2 8 1 V2 S2 V1 A1 S2 Feeder1 V3 S2 VN A3 6 1 V1 CT 7 14 S1 S1 A1 S1 V2 A2 + Pulse - V3 S2 + Pu lse - Pulse output from DM 52 can be integrated into a process through a PLC/DCS for online control of Energy content in a process. If the DCS/PLC has a self excited 12V or 24V Digital Input, external 24V DC Supply is not needed. The kWh pulses may also be used to derive average kW information at the PLC S1 A2 ® V1 S2 S1 V2 S2 7 3 5 6 Feeder 2 13 CT Sl.No. S2 S1 A1 V1 A1 3 VN S1 A3 + Pulse - Feeder N 14 1 10 Remote Totallizer 11 4 PT S2 12 Feeder1 P L C S1 12 DIGITAL INPUT V3 13 + Pu lse - 9 2 11 4 PT 5 12 S1 A2 13 CT Sl.No. 7 14 ® Data Logger V2 S2 Control DCS or PLC Feeder 1 V1 A1 VN S1 6 S1 V3 S2 8 10 3 S1 A3 8 9 2 V2 A2 24v DC Energy Dispensing V1 S2 S2 Energy Management System Energy Totalizing 8 1 S1 A1 + Pulse - Control Output To Contactor + Pu lse - 7 14 ® + Pulse - R e m o t e To t a l l i z e r c a n b e configured to record Data shiftwise, day wise etc., while DM 52 records total consumption. Several DM 52s can be networked into a cost effective centralised system to centrally monitor energy data and generate a variety of reports covering load-wise, shiftwise, day-wise or batch-wise analysis of energy consumption. T h e Pr e s e t t a b l e C o u n t e r i s programmed with the amount of Energy to be dispensed. When it counts down to zero, it deenergises the load. Contact Conzerv for Energy Management Systems. Ordering Option Table Specify Input Input PT ratio Frequency voltage current Pri/Sec (in Hz) (in volts) (in amps) (kV/VLL) CT ratio Aux Pri/Sec supply Tamper (in amps) (in volts) cover Accuracy Wiring EM 5230 CL 1.0 CL 0.5 3 phase 3 wire 50 60 110 415 1 5 11/110 33/110 100/1 1200/5 110 240 DM 5240 CL 1.0 CL 0.5 3 phase 4 wire 50 60 110 415 1 5 415/415 33k/110 5/5 200/5 110 240 Model Note: One typical value for CT and PT ratio is shown above. Meters can be supplied with other ratios also. + ACCESSORIES on order Fused Voltage Probes & Clamp-on Current probes. Energy Audits, Power Quality Audits, Tuned Harmonic Filters, Training on Energy Efficiency, Energy Management Systems, Reactive Power Compensation, Block Reactors, Power Factor Improvement, Multi-Function Meters, Intelligent Power Factor Controllers, Power Analysers, Portable Palm Top Analysers, Genset Synchronisation Meters, AMF Relays, Electronic Energy Meters, Digital Panel Meters, Static Watt Hour Meters, Power Capacitors LT, Current Probes & Voltage Probes. Conzerv Representative Customer Help Desk 1800 425 0555 Email [email protected] (Toll Free All India from BSNL / MTNL lines) Or Call 080 2852 0604 (Standard Charges Apply) www.conzerv.com Con/DM5200N/1007/V1.1 Conzerv strives for continuous product innovation. Product specifications are therefore subject to change without notice. is a Registered Trade Mark of Conzerv Systems Pvt Ltd
© Copyright 2026 Paperzz