CLOCK INPUT CONFIGURATION SETPOINT MODIFICATION PRESS Read carefully the safety guidelines and programming instructions contained in this manual before using/connecting the device. Disconnect power supply before proceeding to hardware settings or electrical wirings. TCT101-3ABC USER MANUAL PIXSYS www.pixsys.net e-mail: [email protected] - [email protected] Software V 2.06 2300.10.139-RevH 060513 Only qualified personnel should be allowed to use the device and/or service it and in accordance to technical data and environmental conditions listed in this manual. Do not dispose electric tools together with household waste materials in observance of European Directive 2002/96/CE WIRING DIAGRAM PNP NPN INTRODUCTION - Techometer TCT101 allows to read the frequency (max 100KHz) of a signal from single or double (bidirectional encoder) input. 2 universal digital inputs are available (NPN/PNP/Potential free contact) for external commands like output activation or Hold/ Stop current visualization; one input it is also analogue in order to allow setpoint modification by external potentiometers. + OUT Proximity Sensor PNP 3 wires Programming Software Power Supply Selects chosen digit 3a LOADING DEFAULT SETTINGS PRESS DISPLAY 3 1 1 1 2 OUT Proximity Sensor PNP 2 wires 1 Fase A Fase Z Fase B POSITIVO GND POTENZIOMETRO 5..10 Kohm Risoluzione 1000 punti Encoder Potentiometer: To modify Set1 or Set2 by external potentiometer follow the steps below: 1- use potentiometers 5kOhm to 10kohm PC ABS UL94V0 self-extinguishing 2- connect cursor to pin I3; a wrong connection may damage the potentiometer and lead to lock of the device. 3PNP/NPN configurable as analogue for potentiometers. 3- accuracy on input is max 1000 points, therefore set the parameters "Upper limit" (max 28 Vdc in PNP mode) and "Lower limit" with a max difference of 1000 units. (Ex.: LoS1 to 50,0 and uPS1 to 150,0 to modify time value related to Set1 between 2 relays 5A resistive charge 50 and 150 seconds with steps of one tenth). Greater differences would make 30mA(24Vac),40mA(24 Vdc),60mA (110...230Vac) unstable the less significant digit. . 4- To calibrate the scale of potentiometer enter the configuration mode and select: Rechargeable battery, approx. 7days autonomy Hin.3 as Pot Fin.3 as Set1 or Set2 P.tAr as Enable Labsoftview 2.6 or later Exit configuration mode and place potentiometer at minimum level and press key, then place potentiometer at max level and press premere key: the device automatically exit the calibration procedure. 24...230Vac/Vdc +/-15% 50/60Hz / 2W N.B.: A switch-off of the device would interrupt the calibration. 2 2 MEANING 3 3 3 There are two methods: Report the activation of Q2 > With the device connected to the power supply insert the memory card when the controller is off. Report serial transmission by the TCT101 3 4 to confirm (Only if the values stored on Mmeory Card are correct). By pressing the Confirm using the Dima di foratura 28.5 x 70.5 mm Frontal panel cut-out Q1 Q2 5A 230V Resistive 1/2HP Spessore suggerito 2÷8 mm Suggested thickness > With the controller disconnected from the power supply: Insert the memory card and press the programming button. When writing the parameters, the LED turns red and on completing the procedure it changes to green. It is possible to repeat the procedure. 5A 230V Resistive 1/2HP PIXSYS TCT101-3ABC MEMORY C.121 To update the memory card values, follow the procedure described in the first method, setting display 2 to so as not to load the parameters on controller. PIXSYS 1 U1 CN1 6 C1 Memory Card (optional) with battery Cod. MEMORY C243 1 CN1 6 35 mm The device loads the new data and starts again. UPDATING MEMORY CARD. TCT101 2 Enter configuration and change at least one parameter. Exit configuration. Changes are saved automatically. MAXIMUM AND MINIMUM PEAK FUNCTION DISPLAY PRESS If enabled maximum peak function, maximum peak value obtained is visualized. 1 2 3 3 77 mm key . The memory card is equipped with an internal battery with a life of about 1000 uses. Memory Card (optional) Cod. MEMORY C121 1 key display 2 shows 7 53 mm and If enabled minimum peak function, minimum peak value obtained is visualized. If enabled peak function, minimum and maximum peak value will initialize to current timer value. Enter password + Scroll parameters pressing or and an arrow key Default Sampling frequency software filter No software filter on reading Mean realized on samplings done within time set in this parameter. Display will be updated according to this time range. Default Visualization time base Visualized value referred to the second Visualized value referred to the minute Visualized value referred to the hour Impulses on visualized unit Number of impulses for single unit. For example, in speed measurement, it indicates how many impulses corresponds to a full revolution. Default 1 pulse ... 9999 pulse 0 0.0 0.00 0.000 Default Tachometer value visualization format No decimal digit visualization 1 decimal digit visualization 2 decimal digits visualization 3 decimal digits visualization Default MEASURE UNIT CONFIGURATION configuration table or 99.99 pulse ... 0.01 pulse P-18 Decimal Point Display shows first parameter of Increase or decrease value on display 5 DO Modify blinking digit, pass to the next one pressing or Enter the new data that will be stored when releasing the keys P-19 Measure Unit 1 Setting digit 1 of displayed measuring unit P-20 Measure Unit 2 Setting digit 2 of displayed measuring unit P-21 Measure Unit 3 Setting digit 3 of displayed measuring unit P-22 Measure Unit 4 Edit digits Setting digit 4 of displayed measuring unit Set each of 4 digits as chosen Default ---- SETPOINT CONFIGURATION End of configuration, the device exits from programming mode. 6 P-23 Display Set 1 P-26 Display Set 2 Disable Visualized Modifiable PARAMETERS LIST CLOCK INPUT CONFIGURATION P-01 Clock Input I1 Encoder Input signal on I1 Input signal on I1 and I2 (bidirectional encoder) Default P-02 Hardware input 1 Input 1 hardware configuration P-05 Filtre Input 1 NPN (not available on input 3) PNP TTL Potentiometer (available only for input 3) P-06 Active State Input 2 Input 2 active state P-07 Active State Input 3 Input 3 active state High level Low level P-08 Function Input 2 Default Disable Min Peak Max Peak All Peak Default 0 Set 1 maximum value (0...9999) Default 999 P-28 Upper Limit Set 2 Set 2 maximum value(0...9999) Default 999 Default Function associated to key UP (up arrow) Desabled Max. registered peak visualization (reset by UP+DOWN key) Default Function associated to key DOWN (down arrow) Desabled Min. registered peak visualization (reset by UP+DOWN key) Default Default 0 Tachometer outputs always enabled Outputs enabled automatically Tachometer outputs enabled by digital inputs P-30 Logic Output Mode1 Tachometer logic output mode 1 P-34 Logic Output Mode2 Tachometer logic output mode 2 High Deviation Low Deviation Inside Band Out of Band P-35 Activation Delay 2 P-32 Deactivation Delay 1 Active output with high deviation Active output with low deviation Active output inside band Active output out of band Default Logic output 2 activation delay Defines logic output activation delay. Default Setting range from 0.0 sec to 999.9 sec. Logic output 1 deactivation delay Logic output 2 deactivation delay Defines logic output deactivation delay. Default Setting range from 0.0 sec to 999.9 sec. Tachometer logic output 1 duration P-37 Output 2 Duration Tachometer logic output 2 duration Automatic Latch output (clear by FNC key) Pulse 0.1 sec to Pulse 99.9 sec Default Logic output 1 activation delay P-33 Output 1 Duration Automatic output duration Latch output, reset by FNC 0,1 sec output inpulse duration Default 99,9 sec output inpulse duration OUTPUT CONFIGURATION P-39 Output Q2 Setup Default Outputs enabled TACHOMETER LOGIC OUTPUT MODE CONFIGURATION P-38 Output Q1 Setup Power-off memory No peak value stored at switch-off Minimum peak value stored at switch-off Maximum peak value stored at switch-off Max. and Min. peak values stored at switch-off Always enable Automati enable Enable by input 0.0 sec to 999.9 sec BACKUP MEMORY CONFIGURATION P-13 Power-off Memory Set 2 minimum value (0...9999) P-25 Upper Limit Set 1 P-36 Deactivation Delay 2 Potentiometer calibration procedure Desabled Enabled P-12 Function Key DOWN Disable Display min peak P-27 Lower Limit Set 2 0.0 sec to 999.9 sec Set1 setting by potentiometer Set2 setting by potentiometer P-11 Function Key UP Disable Display max peak Default Set1 Set 1 minimum value (0...9999) P-31 Activation Delay 1 Default Function associated to Input 3 Desabled Enable / Desable tachometer outputs Hold visualized tachometer value P-10 Potentiom. Tarature Disable Enable Default Function associated to Input 2 P-09 Function Input 3 Disable Out Enable/Disable Hold (only for I3) Set1 (only for I3) Set2 (only for I3) Default Input 1 hardware filter configuration Input hardware filter desabled Input hardware filter enabled (22nF) High Level Low Level Default Set2 P-24 Lower Limit Set 1 P-29 Output Enable P-04 Hardware input 3 Input 3 hardware configuration Off On Setpoint 2 display selection Setpoint value not visualized Setpoint value visualized Setpoint value visualized and modifiable OUTPUT ENABLE CONFIGURATION P-03 Hardware input 2 Input 2 hardware configuration NPN PNP TTL Potent. Setpoint 1 display selection Input signal selection INPUT CONFIGURATION On activation display 1 shows and display 2 shows SIZE AND INSTALLATION 42mm inserimento Memory Card Switch the device off and restart it Display 1 shows with 1st digit blinking, while Display 2 shows for 3 seconds sec min hour P-17 Pulse in Unit The device loads default settings to confirm Parameters and setpoint values can be copied from one device to another using the Memory car. Report the activation of Q1 Guarnizione per 32x74 Cod. 1600.00.082 (optional) Gasket for 32x74 P-16 Timebase Enter password Modify blinking digit, pass to the next digit pressing or For lower frequency values 0 is visualized on display. This parameter forces max. refresh time of display from 100 to 0.1 sec. DISPLAY CONFIGURATION DO Display 1 shows with 1st digit blinking, while Display 2 shows for 3 seconds MEMORY CARD (optional) LED P-15 Software Filter off 0.01 sec ... 1.00 sec Modifies blinking digit of selected SET or 2 Operating Operating temperature 0-40°C, humidity 35..95uR% temperature Sealing Front panel IP65 (with optional gasket) , Box IP30, Terminal blocks IP20 Back-UP 2a CONFIGURATION PARAMETER MODIFICATION PRESS DISPLAY TECHNICAL DATA Outputs OUT 24V Modifies selected SET NPN Thanks for choosing a Pixsys device. Digital Inputs or 2 PNP 0.01 Hz ... 0.09Hz 0.1 Hz ... 10.0Hz Visualizes SETPOINT 1 / 2 2 1 *2300.10.139-F* Material 1 P-14 Minimum Input FrequencyLower frequency visualized DISPLAY Disable Logic Out 1 n.o. Logic Out 1 n.c. Logic Out 2 n.o. Logic Out 2 n.c. Relay Q1 output setting Relay Q2 output setting Desabled output Logic output 1 on n.o. contact Logic output 1 on n.c. contact Logic output 2 on n.o. contact Logic output 2 on n.c. contact Default 2 Default 1 TCT101-3ABC “TACHOMETER” CLOCK INPUT CONFIGURATION P-01 Clock Input 0.01 Hz to 10,0 Hz P-15 Software Filtre P-17 Pulses in Unit P-16 Timebase off 0.01 sec ... 1.00 sec sec min hour INPUT CONFIGURATION P-05 Filter Input 1 P-02 Hardware Input 1 P-23 Display Set 1 Off On P-03 Hardware Input 2 P-08 Function Input 2 High Level Low Level Disable Out Enable/Disable P-09 Function Input 3 P-26 Display Set 2 Disable Out Enable/Disable Hold Display Value Set1 Set2 High Level Low Level P-10 Potentiometer tarature P-11 Function Key UP Disable Enable Set2 P-12 Function Key DOWN Key P-30 Logic Output Mode 1 Disable Display min peak BACKUP MEMORY CONFIGURATION P-13 Power-off Memory PNP input TTL input Logic level H < 4,7 v > 5,7 v (I1, I2) >12,4 v (I3) >2,5 v L > 5,7 v < 4,7 v (I1, I2) < 10,2 v (I3) < 2,0 v Disable Max Peak Min Peak All Peak 0.0 sec ... 999.9 sec ERROR IN READING OF EEPROM MEMORY (NotE 1) P-32 Deactivation Delay 1 0.0 sec ... 999.9 sec INCORRECT STATUS DATA (NotE 1) P-33 Output 1 Duration P-22 Measure Unit 4 edit digit 3 Always enable TACHOMETER OUTPUTS ARE ALWAYS ENABLED. Automatic enable DEPENDING ON LOGIC OUTPUT MODE PARAMETER, THERE ARE DIFFERENT OPERATING MODES: - High Deviation : OUTPUTS ARE ALWAYS ENABLED - Low Deviation : AT STARTING, OUTPUTS ARE DESABLED; THEY CAN BE ENABLED WHEN TACHOMETER VALUE OVERCOMES SETPOINT VALUE AND KEPT ENABLED UNTIL INPUT SIGNAL FALLS BELOW VALUE SET ON PARAMETER «MINIMUM INPUT FREQUENCY» (P-14); - Inside Band : OUTPUTS ARE ALAWAYS ENABLED - Out of Band : AT STARTING OUTPUTS ARE DESABLED, THEY CAN BE ENABLED WHEN TACHOMETER VALUE OVERCOMES SET1-SET2 VALUE, AND KEPT UTNITL INPUT SIGNAL FREQUENCY FALLS BELOW VALUE SET ON PARAMETER «MINIMUM INPUT FREQUENCY» (P-14); Enable by input TACHOMETER OUTPUTS ARE ENABLED TO OPERATE ONLY IF: - INPUT 2 FUNCTION IS SET ON OUT ENABLE/DISABLE AND INPUT IS ACTIVE - INPUT 3 FUNCTION IS SET ON Out Enable/Disable AND INPUT IS ACTIVE Logic Out SET Tach. Value Activation delay P-34 Logic Output Mode 2 Time 0 Auto 1 Clear by FNC Key P-35 Activation Delay 2 Pulse duration time 0 Tach. Value Q2 Tach. Value Tach. Value Activation delay Deactivation delay Output duration Set Logic Out SET Activation delay Deactivation delay Time Logic output 0 Auto 1 Clear by FNC Key 0 Pulse 1 Tach. Value Activation delay Deactivation delay Output duration Set1 Set2 Tach. Value SET2 Logic Out SET2 Tach. Value SET1 Activation delay Activation delay Deactivation delay Deactivation delay Time Logic output 0 Auto 1 Clear by FNC Key Clear by FNC Key 0 Latch 1 Pulse duration time P-36 Deactivation Delay 2 0.0 sec ... 999.9 sec P-37 Output 2 Duration Automatic Latch output (clear only by FNC key) Pulse 0.1 (sec) to Pulse 99.9 (sec) n.o. n.c. n.o. n.c. Pulse 1 Pulse duration time 0 Pulse 1 Tach. Value 0.0 sec ... 999.9 sec 1 1 2 2 P-39 Output Q2 (relay) Setup 0 Latch 1 Output duration mode High Deviation Low Deviation P-38 Output Q1 (relay) Setup Disable Logic Out Logic Out Logic Out Logic Out Pulse duration time TACHOMETER LOGIC OUTPUT MODE CONFIGURATION OUTPUT RELAIS CONFIGURATION Q1 Deactivation delay 0 Automatic Latch output (clear only by FNC key) Pulse 0.1 (sec) to. Pulse 99.9 (sec) edit digit 4 3 Latch 1 INCORRECT BACKUP REGISTERS (NotE 2) NotE 1: SWITCH THE DEVICE OFF AND RESTART IT; IF ERROR IS STILL NOTIFIED, CONTACT TECHNICAL SERVICE. NotE 2: DISCHARGED BATTERY. KEEP THE DEVICE CONNECTED TO THE POWER SUPPLY IN ORDER TO RECHARGE THE BATTERY. edit digit 2 Tach. Value Activation delay Deactivation delay Output duration Set Output duration mode INCORRECT PARAMETERS (NotE 1) INCORRECT CALIBRATION DATA (NotE 1) P-21 Measure Unit 3 Logic output TABLE OF ERROR MESSAGES ERROR IN WRITING OF EEPROM MEMORY (NotE 1) Tach. Value Output duration mode POWER-ON RESET NPN input Out Enable High Deviation Low Deviation Inside Band (Band defined by SET2) Out of Band (Band defined by SET2) P-31 Activation Delay 1 Disable Display max peak Type of input P-29 Output Enable 2 P-28 Upper limit Set 2 TACHOMETER LOGIC OUTPUT MODE CONFIGURATION I3 Key 1 OUTPUT ENABLE CONFIGURATION Always enable Automatic enable Enable by Input P-25 Upper limit Set 1 Disable P-27 Visualized Lower limit Modifiable Set 2 P-07 Active State Input 3 PNP TTL Potent. 0 0.0 0.00 0.000 Disable P-24 Visualized Lower limit Modifiable Set 1 I2 P-04 Hardware Input 3 99.99 to 0.01 1 to 9999 P-20 Measure Unit 2 edit digit 1 Set1 P-06 Active State Input 2 NPN PNP TTL P-18 Decimal Point SETPOINT CONFIGURATION I1 NPN PNP TTL P-19 Measure Unit 1 DISPLAY CONFIGURATION P-14 Minimum Input Frequency I1 Encoder MEASURE UNIT CONFIGURATION Activation delay Deactivation delay Output duration Set1 Set2 Tach. Value SET2 SET2 Tach. Value SET1 Activation delay Deactivation delay Deactivation delay Activation delay Time Logic output Output duration mode 0 Auto 1 Clear by FNC Key Clear by FNC Key 0 Latch 1 Pulse duration time 0 Pulse 1 Pulse duration time Logic Out Disable Logic Out Logic Out Logic Out Logic Out 1 1 2 2 n.o. n.c. n.o. n.c.
© Copyright 2026 Paperzz