NEUROSPECT QUAD ™ FIXED FOUR HEADED SPECT IMAGING SYSTEM NCS (800-548-4024) NEUROSPECT QUAD™ SPECIFICATION & FEATURES Parameter Central Field of View (CFOV) Intrinsic spatial resolution FWHM FWTM Intrinsic energy resolution FWHM Intrinsic flood field uniformity integral differential Intrinsic spatial linearity absolute differential Intrinsic high count rate performance 20% count rate loss maximum count rate Intrinsic spatial resolution at 75 kcps FWHM FWTM Intrinsic flood field uniformity at 75 kcps integral differential Multiple window spatial resolution Point Source Sensitivity System Spatial Resolution w/scatter( LEAP @ 10cm) FWHM FWTM System Spatial Resolution w/o scatter ( LEAP @ 10cm) FWHM FWTM System Sensitivity LEAP Collimator Useful Field of View (UFOV) ≤ 2.72mm ≤ 5.44mm ≤ 2.8mm ≤ 5.6mm ≤ 9.7% ≤ 9.7% ± 2.4% ± 1.9% ± 2.9% ± 2.4% ≤ 0.38mm ≤ 0.18mm ≤ 0.40mm ≤ 0.20mm 160kcps 200kcps 160kcps 200kcps ≤ 2.5mm ≤ 4.97mm ≤ 2.54mm ≤ 4.97mm ± 2.6% ± 1.9% ± 3.8% ± 2.2% ≤ 1.5mm ≤ 1.5mm ± 0.5% ± 0.5% ≤ 8.7mm ≤ 15.5mm ≤ 8.7mm ≤ 15.5mm N/A N/A N/A N/A 360 cpm/µCi 360 cpm/µCi Performance Specifications - Reconstructed System Spatial Resolution Radial Tangential Center (Non RM2 ) SPECT FWHM ≤ 7.5mm ≤ 4.0mm ≤ 7.5mm Resolution Matched Matrix (RM2 ) SPECT FWHM ≤ 5.6mm ≤ 3.2mm ≤ 5.6mm Features: • Configured specially for brain imaging • Four Fixed 90˚ ring small FOV ultra high resolution detectors • Four independent energy channels • Excellent resolution / short time imaging • 2.5mm low attenuation SPECT pallet • High density FPGA technology • Ultra fast, 40 MHz digitizing • 4096 pixel image digitizing • Real-time cross correction for each energy level and different collimators • SW-based pile-up correction for high count rate • Pre-programmed robotic gantry motions for precise positioning • Ring Gantry Design • Fixed position SPECT gantry, high stability • Low energy high resolution (LEHR) collimator • 90˚ and 180˚ SPECT movements • Motorized vertical movement imaging table (250mm) • Specially design comfortable head support • Easy to change collimators Options: • Additional collimators • Collimator cart • SPECT table accessories 33 (5.08cm diameter) high performance photo-multiplier tubes (PMTs) Detector thickness 9.50mm / FOV 215 x 230mm (Camera specifications and features may change without notice. Options may carry additional charges, please call for additional information and/or pricing.) NCS Nuclear Cardiology Systems, Inc. 5660 Airport Blvd., Suite 101 • Boulder, CO 80301 phone: 800-548-4024 fax: 303-541-0066 [email protected] NEUROSPECT QUAD™ PHYSICAL & PARAMETERS Power Requirements Electrical Service 100 / 120 VAC ± 10%, 60/50Hz, 20 amperes, Dedicated Receptacle 102-125 volts, 3 prong (Hospital grade.) Line Regulation 105 volts AC to 125 volts AC. Continuous Current 9 amps, maximum. Depends on number of modules and system configuration. Dedicated Power 1. One dedicated separate isolated line (free of noise or transients and other electrical equipment) is required for the camera. The dedicated power lines must meet the minimum electrical service requirements of 20 amps. 2. One dedicated separate isolated line (free of noise or transients and other electrical equipment) is desired for the Computer system. Refer to the preinstallation chapter of the Computer Service Manual for the power requirements. 3. An isolation/filtering transformer is recommended for any source not satisfying the power noise and ground specifications. Consult NC Systems for additional information. Power Noise and Ground Specifications Power Line Ground Noise Measured between power line return (neutral) and ground return (green ground terminal) must be less than 50 millivolts peak-to-peak over the frequency spectrum of 0-50 MHz. The probable cause of ground noise in excess of 50mV pp is a high ground impedance (faulty ground line.) Ground Impedance Measured between neutral and ground must be less than 0.1 ohm. This must be measured according to UL 544 for ground impedance (i.e., less than 2.5-volt drop across ground-to-neutral with a 25 amp AC current flowing through it.) Camera Ground The Gamma Camera requires a separate ground Environmental Requirements Temperature Requirements Ambient Temperature 55°F (13°C) to 90°F (32°C.) Temperature Change Not greater than 10°F (3°C) per hour. The image detector should never be subjected to a temperature change greater than 10°F (3°C) per hour. The detector must be located away from heating and air-conditioning outlets. Windows in the room should be locked to prevent accidental temperature shock that may damage the detector scintillation detector. Humidity Requirements Relative Humidity should be maintained at 50-60%. Static electricity charges associated with lower humidity levels may interfere with camera operation. Higher humidity conditions may shorten the life of the scintillation detector and other components. Background Radiation Should be kept to a minimum by keeping radioactive sources in shielded containers. The camera emits no radiation. Electrical Radiation Radiated electrical signals, such as personal paging telemetry systems, may cause interference with normal camera operation. Locate the equipment so it is not in the path of the transmitting antenna. Heat Dissipation These figures are given to aid in planning of airconditioning requirements and assume all electronic module slots are occupied. System Layout Air Flow An air circulation corridor of 15 feet (18 inches minimum) must be maintained between the wall and the rear of the operator’s electronics console. Serviceability A clear area of 3 feet (minimum) should be maintained in front of all cabinets Basic Room Layout The basic layout will be provided by NCS. Camera Max. Current = 9 amps Max. Heat = 2,400 BTU Computer and Accessories Max. Current = 6 amps Max. Heat = 2,500 BTU NOTE: Depends on the number of modules and system configuration. For a precise measurement, measure the voltage and current at the line cord and calculate BTU’s as follows: WATTS= (Voltage) x (Current) BTU= (Watts) x (3.1434) System Physical Specifications Image Detector Stand Assembly Height: 59.8 inches (152 cm) Width: 47.2 inches (120 cm) Length: See page 4 of 4 of specification for options Weight: 1760 lbs Floor Loading: Standard–434 lbs/sq. ft. Operator Console Height: 15 inches (38.1 cm) Width: 18.5 inches (47 cm) Depth: 29 inches (73.7 cm) Weight: 86 lbs (39 kg) (Camera specifications and features may change without notice. Options may carry additional charges, please call for additional information and/or pricing.) NCS Nuclear Cardiology Systems, Inc. 5660 Airport Blvd., Suite 101 • Boulder, CO 80301 phone: 800-548-4024 fax: 303-541-0066 [email protected] NEUROSPECT QUAD™ DIMENSIONS / LAYOUT ~10' 6" ~2' 8" f * 12' x 18' EXAMPLE LAYOUT a b U P S UPS 36" Door e * CARDIOSPECT QUAD™ Gamma Camera b CARDIOSPECT QUAD™ SPECT Table c Acquisition Terminal d CARDIOSIGHT ™ Computer e Color Imager (Printer) f Radiopharmaceutical Hot Lab 100 / 120 VAC ± 10%, 60/50Hz, 20 amperes, Dedicated Line * c a d * 100 / 120 VAC ± 10%, 60/50Hz, 15 amperes, Dedicated Line Dedicated Modem Line Here For 24 Hour Support. FMARK0110(Rev new) (Camera specifications and features may change without notice. Options may carry additional charges, please call for additional information and/or pricing.) NCS Nuclear Cardiology Systems, Inc. 5660 Airport Blvd., Suite 101 • Boulder, CO 80301 phone: 800-548-4024 fax: 303-541-0066 [email protected]
© Copyright 2026 Paperzz