EFC Thermostat Specification & Installation Instructions Features: EFC Series fan coil controller Used to program/configure the EFC Fan Coil controller x Attractive modern look with large LCD and backlight x Icons driven information and 1 line of text information x 3 wire or RJ45 Ethernet cable between thermostat & EFC x Programmable analog & digital outputs x Selectable fan speed contacts x Selectable Fahrenheit or Celsius scale x Occupancy sensor (programmable) x Multi level lockable access menu x Selectable internal or external temperature sensor x Programmable proportional control band & dead band x Change over by contact or external temperature sensor available x Anti-freeze protection x BACnet® MS/TP @ 9600, 19200, 38400, 76800bps x Selectable MAC Address by dip switch on the EFCB x Selectable device instance via technician menu TFL54 TFL55 3 wire cable RJ45 (Ethernet cable) Technical Data Electrical connection Setpoint range Control accuracy Power supply TFL54 TFL55 TFLH54-xxx TFLH55-xxx x TFLH54-xxx TFLH55-xxx 3 wire cable RJ45 (Ethernet cable) Temperature: 10ºC to 40ºC [50ºF to 104ºF] 10ºC to 40ºC [50ºF to 104ºF] Humidity: 10 to 65%RH Temperature: ±0.5ºC [0.9ºF] @ 22ºC [71.6ºF] Temperature: ±0.5ºC [0.9ºF] @ 22ºC [71.6ºF] typical calibrated typical calibrated, Humidity ±3.5% From EFC Power consumption 1 VA Display resolution ±0.1ºC [0.2ºF] Proportional band 0.5ºC to 5ºC [1ºF to 10ºF] adjustable Operating temperature 0ºC to 50ºC [32ºF to 122ºF] Storage temperature -30ºC to 50ºC [-22ºF to 122ºF] Relative humidity 5 to 95 % non condensing Housing degree of protection IP 30 (EN 60529) Weight 80 g. [0.15 lb] The TFL(H)5x can only work with the EFC. All the inputs/outputs are located on the EFC except Note for the temperature sensor built-in the TFL(H)5x. Interface Display Symbols Cooling ON 100% output A: Automatic Heating ON 100% output A: Automatic Fan ON 100% output A: Automatic Menu set-up lock Programming mode (Technician setting) Alarm status Energy saving mode or ºC: Celsius scale ºF: Fahrenheit scale Minimum/Maximum setpoints Dimensions B D A TFL(H)5x.doc/111031 Dimension A B C D Imperial (in) 3.00 3.00 1.00 2.36 Metric (mm) 78 78 24 60 C 1 Specification & Installation Instructions TFL(H)5x Mounting Instructions A B C D E CAUTION: Risk of malfunction. Remove power prior to separate thermostat cover (control module) from its base. A. Remove the screw (captive) holding the base and the front cover of the thermostat. B. Lift the front cover of the thermostat to separate it from the base. C. Pull the cable through the base hole. D. Secure the base to the wall using wall anchors and screws (supplied). Make the appropriate connections. E. Mount the control module on the base and secure using the screw (from step A). Settings on PC Board & Connections Mode Selection (JP1) JP1 RUN PGM Jumper (JP1) on RUN: Thermostat is in Operation Mode. Thermostat must be set in this mode to operate properly. If not locked, setpoint, fan speed and control mode (Heating & Cooling ON, Cooling only ON or Heating only ON) can be modified by end user. RUN PGM Jumper (JP1) on PGM: Thermostat is set in Programming Mode. Refer to following section about all settings description TFL55 – RJ45 Ethernet cable BACnet service port works only if TFL(H)5x is connected to EVCB PGM RUN RUN JP1 JP1 TFL54 – 3 wire cable (TB5 #1, 2 & 3) Connect TB6 #4 (A+) & #5 (B-) to EFCB for BACnet service port to work JP1 Connecting strip PGM TB1 24V 2 COMM. BUS 3 AI1 4 DI1 5 A+ 6 B- RJ45 connector Mode selector Temperature sensor 7 Temperature BACnet sensor service port COM 1 Mode selector BACnet service port Recycling at end of life ® At end of life, please return the thermostat to your Neptronic local distributor for recycling. If you need to find the nearest Neptronic authorized distributor, please consult www.neptronic.com. ® 2
© Copyright 2026 Paperzz