3 Peltier Gas Cooler Series ECP® Version ECP 20-2 for 500 Nl/hr gas flow rate (single stream) ECP 20-2 PV • Compact, self-controlling and maintenance-free • With patented Jet-Stream heat exchanger available in 3 standard materials • Gas flow rate 1 stream x500 l/hr • Dew point adjustable at +5 °C ± 0,1 °C • Status-Alarm contact standard • Small dimensions • Light weight • Optimum reliability Application The M&C gas cooler ECP-20-2 is used in gas analysis to lower the dew point of humid gas to avoid condensation in the analyser. An extremely stable gas dew point avoids water vapour cross-sensitivity and volumetric errors. Description The electronically controlled peltier cooler produced by M&C incorporates the patented ‘’Jet-Stream’’ design of heat exchanger. This design induces condensate formation and guarantees optimum dew point reduction to a stable low value, eliminating the need for additional pre-drainage devices. The condensate formed should be removed with a small peristaltic pump, sample trap or collection vessel. The simple construction employed enables heat exchangers of different materials to be used depending on the application. The operating status of the cooler is displayed by three LED’s, one each for over or under temperature alarm and one which pulsates indicating the cooler is functioning correctly. The alarm status changes when the temperature deviates by +/-3 °C from the set point. The gas cooler ECP 20-2 has got two EC-Jet-stream heat exchangers which are best employed using one as a pre-cooler and the second as a main or final cooler with a flow capacity max. of 500 Nl/hr. The compact lightweight design of this device makes it ideal for use in portable and compact continuous sample conditioning systems. The gas cooler is self-controlling and maintenance-free. 1/3 3-1.10 © M&C 05.97 / 06.01 Technical details are subject to change. Copying, including extracts, not permitted unless authorized by M&C. M&C Products Analysentechnik GmbH • Rehhecke 79 • 40885 Ratingen • Germany • Tel.: +49 (0) 21 02 / 9 35-0 • Fax: / 9 35-111 • E-mail: [email protected] • www.muc-products.de 3 Example application for ECP 20-2 10 1 2 3 4 5 6 7 8 Heated filter sample probe SP2000-H Heated sample line 4M4/6 Cooler ECP20-2 3-way ball valves 3L/PV-1 Peristaltic pumps SR25.1 Diaphragm pump MP47 Fine filter FP-2T-D with liquid alarm LA1 Aerosol filter CLF-5/W optional according to application 9 Flow meter FM10, 50-500 Nl/hr 10 Analyser, e. g. PMA1000 Testgas IN 4 Sample Gass IN 1 8 3 ECP20-2 +5 °C 9 6 7 2 5 Alternative: Trap with float or condensate vessel Condensate OUT Dimensions Functioning diagram of M&C-heat exchanger ECP 20-2 side view front view 210 226 72 95 38 Sample gas - OUT 2xGL 18 Sample gas - IN 90 60 ø7 M&C Jet-Stream heat exchanger Cooling block +5°C 280 385 °C ON °C GL 25 PG 11 PG 9 Power -in Condensate - OUT Alarm contact Sample outlet dew point °C Abmessungen in mm Sample outlet dew point difference for the gas cooler ECP20-2 with heat exchangers out of: 20 60 °C -1/Glas 40 °C -1/Glas 60 °C -2/PVDF 16 40 °C -2/PVDF 60 °C -3/SS316Ti 40 °C -3/SS316Ti 1 Glass 2 PVDF 3 Stainless steel 316Ti 12 8 4 0 50 100 150 200 250 300 350 400 450 500 550 in dependence on the gas flow rate and 40 °C and 60 °C sample inlet dew point at 25 °C ambient temperature. Sample gas flow rate Nl/hr 2/3 3-1.10 © M&C 05.97 / 06.01 Technical details are subject to change. Copying, including extracts, not permitted unless authorized by M&C. M&C Products Analysentechnik GmbH • Rehhecke 79 • 40885 Ratingen • Germany • Tel.: +49 (0) 21 02 / 9 35-0 • Fax: / 9 35-111 • E-mail: [email protected] • www.muc-products.de 3 Technical Data Gas Cooler series ECP® Part No. Gas Cooler ECP 20-2 Material of heat exchanger Gas pressure max.-bar abs. 2) with GL adapter Sample gas connection Condensate connection ∆P at 500 Nl/hr flow rate Stagnant space per heat exchanger Gas stream / Gas flow rate Ambient temperature Sample outlet dew point Dew point stability Sample inlet temperature Sample inlet dew point Total cooling capacity at +25 °C ambient Main power connection / Power consumption Ready for working Electrical connection Status alarm 1 changeover contact, potential free Case protection / Electrical standard Method of mounting / Case colour Dimension / Weight ECP 20-2 01K8100 01K8140 01K8120 Duran glass® PVDF st. steel AISI 316Ti 2 / 32) 3 10** for ø 6 mm o.d. tube G1/4"i for ø 12 mm o.d. tube G3/8"i 5 mbar approximately 70 ml 1x max. 500 Nl/hr * +5 to +45 °C set in factory +5 °C ±1 °C, range of adjustment 0-15 °C at constant conditions ± 0,1 °C* max. 180 °C* max. 80 °C* 80 kJ/h 230V 50Hz or 115V 60Hz switchable, 250VA <20 min. terminals 2,5 mm2, 2x PG11 cable gland contact rating 250V, 2A, 500VA, 50W alarm point: ∆ ±3 °C to TSOLL IP54 EN60529 / EN61010 wall mounting / case colour black 210x385x 226 mm / 12,5 kg * Maximum values in technical datas must be rated in consideration of total cooling capacity at 25 °C ambient temperature. ** Other versions on request. GL-adapter and tube fittings for the connection of different tube diameters at the heat exchanger see data sheet 3-5.1.1 and 7-1. 3/3 3-1.10 © M&C 05.97 / 06.01 Technical details are subject to change. Copying, including extracts, not permitted unless authorized by M&C. M&C Products Analysentechnik GmbH • Rehhecke 79 • 40885 Ratingen • Germany • Tel.: +49 (0) 21 02 / 9 35-0 • Fax: / 9 35-111 • E-mail: [email protected] • www.muc-products.de
© Copyright 2025 Paperzz