SGBL Series (Electronic) Residual Current Operated Circuit Breaker(RCBO) 14 Technical data Standard EN / IEC 61009 -1 Breaking capacity 6kA Protection Ground fault, overcurrent and short circuit Rated current, In 3, 6, 10, 16, 20, 25, 32, 40A Operating, IƸn 10,30, 100, 300mA Characteristic B.C Rated residual current operated making & breaking capacity IƸm 500A Rated residual non-operated current IƸno 0.5IƸn Rated impulse withstand voltage Uimp 4000V Number of poles 1P+N Rated voltage 230VAC Ambient temperature -25oC~+45oC,Max. 95%humidity Residual current off-time İ 0.1 sec. Type of trip Ground fault Electronic Over current Thermal-magnetic Protection degree IP20 Installation 35mm DIN rail Width 2 modules Type of terminal Lug type and Pin type SGBL RCBO Rated current (A) curve C curve Packing unit 3 SGBL-B3/10 SGBL-C3/10 1 6 SGBL-B6/10 SGBL-C6/10 1 10 SGBL-B10/10 SGBL-C10/10 1 SGBL-B16/10 SGBL-C16/10 1 SGBL-B20/10 SGBL-C20/10 1 25 SGBL-B25/10 SGBL-C25/10 1 32 SGBL-B32/10 SGBL-C32/10 1 40 SGBL-B40/10 SGBL-C40/10 1 3 SGBL-B3/30 SGBL-C3/30 1 6 SGBL-B6/30 SGBL-C6/30 1 10 SGBL-B10/30 SGBL-C10/30 1 SGBL-B16/30 SGBL-C16/30 1 SGBL-B20/30 SGBL-C20/30 1 25 SGBL-B25/30 SGBL-C25/30 1 32 SGBL-B32/30 SGBL-C32/30 1 40 SGBL-B40/30 SGBL-C40/30 1 3 SGBL-B3/100 SGBL-C3/100 1 6 SGBL-B6/100 SGBL-C6/100 1 10 SGBL-B10/100 SGBL-C10/100 1 SGBL-B16/100 SGBL-C16/100 1 SGBL-B20/100 SGBL-C20/100 1 25 SGBL-B25/100 SGBL-C25/100 1 32 SGBL-B32/100 SGBL-C32/100 1 40 SGBL-B40/100 SGBL-C40/100 1 3 SGBL-B3/300 SGBL-C3/300 1 6 SGBL-B6/300 SGBL-C6/300 1 10 SGBL-B10/300 SGBL-C10/300 1 SGBL-B16/300 SGBL-C16/300 1 SGBL-B20/300 SGBL-C20/300 1 25 SGBL-B25/300 SGBL-C25/300 1 32 SGBL-B32/300 SGBL-C32/300 1 40 SGBL-B40/300 SGBL-C40/300 1 16 20 16 20 Type AC B 16 20 16 20 10mA 30mA 100mA 300mA 15 SGBL RCBO 16 Rated current (A) curve C curve Packing unit 3 SGBL-B3/10-A SGBL-C3/10-A 1 6 SGBL-B6/10-A SGBL-C6/10-A 1 10 SGBL-B10/10-A SGBL-C10/10-A 1 SGBL-B16/10-A SGBL-C16/10-A 1 SGBL-B20/10-A SGBL-C20/10-A 1 25 SGBL-B25/10-A SGBL-C25/10-A 1 32 SGBL-B32/10-A SGBL-C32/10-A 1 40 SGBL-B40/10-A SGBL-C40/10-A 1 3 SGBL-B3/30-A SGBL-C3/30-A 1 6 SGBL-B6/30-A SGBL-C6/30-A 1 10 SGBL-B10/30-A SGBL-C10/30-A 1 SGBL-B16/30-A SGBL-C16/30-A 1 SGBL-B20/30-A SGBL-C20/30-A 1 25 SGBL-B25/30-A SGBL-C25/30-A 1 32 SGBL-B32/30-A SGBL-C32/30-A 1 40 SGBL-B40/30-A SGBL-C40/30-A 1 3 SGBL-B3/100-A SGBL-C3/100-A 1 6 SGBL-B6/100-A SGBL-C6/100-A 1 10 SGBL-B10/100-A SGBL-C10/100-A 1 SGBL-B16/100-A SGBL-C16/100-A 1 SGBL-B20/100-A SGBL-C20/100-A 1 25 SGBL-B25/100-A SGBL-C25/100-A 1 32 SGBL-B32/100-A SGBL-C32/100-A 1 40 SGBL-B40/100-A SGBL-C40/100-A 1 3 SGBL-B3/300-A SGBL-C3/300-A 1 6 SGBL-B6/300-A SGBL-C6/300-A 1 10 SGBL-B10/300-A SGBL-C10/300-A 1 SGBL-B16/300-A SGBL-C16/300-A 1 SGBL-B20/300-A SGBL-C20/300-A 1 25 SGBL-B25/300-A SGBL-C25/300-A 1 32 SGBL-B32/300-A SGBL-C32/300-A 1 40 SGBL-B40/300-A SGBL-C40/300-A 1 16 20 16 20 Type A B 16 20 16 20 10mA 30mA 100mA 300mA 1. Curves 17 2. Breaking time of residual current In (A) IƸn (A) 3~40 0.01,0.03,0.1,0.3 Max. Breaking times IƸn 2IƸn 5IƸn 5A, 10A, 20A, 50A, 100A, 200A, 500A 0.1s 0.08s 0.04s 0.04s 3. Wiring The suitable conductors should be used for connection,see table below for relative parameters. Rated current In (A) Cross section area S (mm2) Tightening torque (N . m) 3~6 1 2 10 1.5 2 16~20 2.5 2 25 4 2 32 6 2 40 10 2 4. Types Both RCCBs and RCBOs are devided into types depending on the operating function: Type AC : For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising. Type A :For which tripping is ensued for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising. 5. Overall and mounting dimensions 75±0.5 45±0.5 50±0.5 36±0.5 81.5±0.5 36±0.5 34±0.5 5
© Copyright 2026 Paperzz