LINAC 2004 XXII International Linear Accelerator Conference Lübeck, Germany, 17 August 2004 CLIC Magnet Stabilization Studies (TUP88) R. Assmann, W. Coosemans, G. Guignard, S. Redaelli, D. Schulte, I. Wilson, F. Zimmermann CERN AB-ABP Geneva, Switzerland 1. 2. 3. 4. Introduction CLIC Stability Study - experimental setup Highlights of experimental achievements Conclusions 1. Introduction - Stability issues in linear colliders Ne = particles per bunch Nb = number of bunches frep = repetition frequency x,y = colliding beam sizes Pb = beam power CLIC: Luminosity in linear colliders: Ecm = 3 - 5 TeV L = 0.8 x 1035 cm-2s-1 Pb 2 x 15 MW x x y = 60 nm x 0.7 nm The luminosity depends strongly on the relative beam-beam offset: Final focus quadrupole Final focus quadrupole y Beam 1 *IP Final focus quads must be stable to a fraction of the colliding beam size!! Beam 2 Tolerances for 2% luminosity reductions S.R., LINAC04 Magnet Linac Final Focus Nmagnet 2600 2 fmin 4 Hz 4 Hz Ix 14 nm 4 nm Iy 1.3 nm 0.2 nm Is this really achievable? page 2 2. CLIC Stability Study Activities from January 2001 to December 2003 People: R. Assmann, W. Coosemans, G. Guignard, S. Redaelli, D. Schulte, I. Wilson, F. Zimmermann Goal: Demonstrate the feasibility of colliding nanometre-size particle beams in CLIC How well can we stabilize magnets in a real accelerator environment? Our approach: use state-of-the-art stabilization devices to stabilize CLIC prototype quadrupoles in a normal working environment. S.R., LINAC04 page 3 The CLIC test stand for vibration measurements and magnet stabilization: The experimental setup includes: S.R., LINAC04 • Sensors for vibration measurements (geophones) • Honeycomb table (virtually) with no internal resonances • Prototypes accelerator magnets • State-of-the-art stabilization equipment • Stretched-wire system for alignment measurements page 4 3. Achieved quadrupole stability RMS vibrations above 4 Hz Quad Ground [nm] [nm] Vertical 0.43 6.20 Horizontal 0.79 3.04 Longitud. 4.29 4.32 Integrated RMS motion [ nm ] Integrated vertical RMS motion versus frequency 10 Floor (Normal working area) 1.3 nm 1 Quadrupole 0.2 nm 0.1 Toleran. of linac quads Toleran. of FF quads Beam-based feedbacks correct motion below 4Hz 0.01 1 4 Hz 10 100 Frequency [Hz] CLIC prototype magnets stabilized to the sub-nanometre level !! Above 4Hz: 0.43 nm on the quadrupole instead of 6.20 nm on the ground. S.R., LINAC04 page 5 Vertical RMS motion above 4 Hz [ nm ] S.R., LINAC04 12 0 2 Quadrupole Saturday Friday Thursday Wednesday Tuesday Monday Sunday Saturday Friday Thursday 14 19:35 03:15 10:55 18:35 02:15 09:55 17:35 01:15 08:55 16:35 00:15 07:55 15:35 23:15 06:55 14:35 22:15 05:55 13:35 21:15 04:55 12:35 20:15 03:55 11:35 19:15 02:55 10:35 18:15 01:55 09:35 Ok, this is good. But is it stable? Jeûne Genevois Day 10 10 nm Ground 8 6 4 Linac tolerance 1.3 nm Time Quadrupole vibrations kept below the 1 nm level over a period of 9 consecutive days! page 6 4. Conclusions The CLIC Stability Team has demonstrated the principle feasibility of colliding nanometre-size beams in future linear accelerators like CLIC: For the first time, a prototype quadrupole was stabilized to 0.5 nm above 4 Hz in a normal working area. Stabilization below 1 nm continuously for several days. Horizontal stability within tolerances. Simulations of time-dependent CLIC luminosity indicate that 70% of the nominal luminosity can be achieved! Outlook Stabilization performance on more realistic quadrupole prototypes Study integration of tested devices in the CLIC detector region S.R., LINAC04 page 7
© Copyright 2026 Paperzz