Biotech Test Elements

Fact Sheet
Biotech Elements
Small Size Spiral-wound Elements for Lab Testing
The Biotech Test product family includes RO, NF, UF and
MF membranes. These small elements are used for trials
when the amount of feed liquid available is limited.
The Biotech Test Elements are made with high temperature stable construction materials. The maximum recommended operating temperature is 50°C (122°F). Operation
at temperature above 50°C (122°F) is possible however
permeability will be reduced by irreversible compaction.
The Biotech Test Elements feature a Durasan* Cage patented Outerwrap, a 34 mil spacer and polysulfone parts.
Table 1B: Element Specification – Nanofiltration
Membrane
Model
D-Series Thin-Film Membrane (TFM*)
Duracid Series
Minimum Membrane Area
Rejection1,2
ft2 (m2)
Outerwrap
Part
Number
DK1812
98% MgSO4
4.0 (0.38)
Cage
1255117
DL1812
96% MgSO4
4.0 (0.38)
Cage
3051745
DURACID NF1812
98% MgSO4
4.0 (0.38)
Cage
3052540
Average salt rejection after 24 hours operation.
2 Testing conditions: 2,000ppm MgSO solution at 110psi (760kPa) operating pres4
sure, 25°C (77°F), pH 7.5 and 15% recovery.
1
Table 1C: Element Specification – Ultra and Microfiltration
Membrane
Figure 1: Element Dimensions Diagram – Female
G-Series Thin-Film Membrane (TFM*)
M-Series (Hydrophilic Polyacrylonitrile PAN)
P-Series (Polyethersulfone PES)
J-Series (Polyvinylidene difluoride PVDF)
Table 1A: Element Specification – Reverse Osmosis
Membrane
A-Series and S-Series Thin-Film Membrane (TFM*)
Minimum
Rejection1
Membrane Area
ft2 (m2)
Outerwrap
Part
Number
99% NaCl2
4.0 (0.38)
Cage
3051741
AG1812HR
99.3% NaCl2
4.0 (0.38)
Cage
3062684
AG1812LF
99% NaCl2
4.0 (0.38)
Cage
3062685
AK1812
98% NaCl2
4.0 (0.38)
Cage
3051742
AP1812
92% NaCl3
4.0 (0.38)
Cage
3148691
SE1812
97.5% NaCl4
4.0 (0.38)
Cage
3051750
Model
AG1812
Average salt rejection after 24 hours operation.
2 Testing conditions: 2,000ppm NaCl solution at 225psi (1,551kPa) operating pressure, 25°C (77°F), pH 7.5 and 15% recovery.
3 Testing conditions: 500ppm NaCl solution at 75psi (520kPa) operating pressure,
25°C (77°F), pH 7.5 and 15% recovery.
4 Testing conditions: 2000ppm NaCl solution at 425psi (2930kPa) operating pressure, 25°C (77°F), pH 7.5 and 15% recovery.
1
MWCO
(Dalton)
Membrane area
ft2 (m2)
Outerwrap
Part
Number
GE1812
1,000
4.0 (0.38)
Cage
1255124
GH1812
2,500
4.0 (0.38)
Cage
1255123
GK1812
3,500
4.0 (0.38)
Cage
1255122
MW1812
30,000
4.0 (0.38)
Cage
1255107
PT1812
5,000
4.0 (0.38)
Cage
3051748
PW1812
20,000
4.0 (0.38)
Cage
3051749
JX1812
0.3 micron
4.0 (0.38)
Cage
1255108
Model
Table 2: Dimensions and Weight
Model
All 1812
Dimensions, inches (cm)
Boxed
A
B
C
Weight lbs (kg)
12 (30.48)
0.625 (1.59)
1.85 (4.7)
0.15 (0.3)
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2017, General Electric Company. All rights reserved.
FSpsBiotechTestElem_EN.docx May-17
Table 3: Operating and CIP parameters
Reverse Osmosis: A-Series
Ultrafiltration: G-Series
Typical Operating Flux
5-20GFD (8-34 LMH)
Maximum Operating Pressure
400 psi (2,760 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
Typical Operating Flux
5-20GFD (8-34 LMH)
Maximum Operating Pressure
600 psi (4,137 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH Range
Continuous operation: 2.0-10.0,
Clean-In-Place (CIP): 1.0 – 13.01
pH Range
Continuous operation: 3.0-10.0,
Clean-In-Place (CIP): 1.0 – 13.01
Maximum Pressure Drop
Over an element 15psi (103kPa)
Chlorine Tolerance
20-50 ppm x days
Maximum Pressure Drop
Over an element 15psi (103kPa)
Chlorine Tolerance
500+ ppm x hours,
Dechlorination recommended
1 Please
refer to Cleaning Guidelines Technical Bulletin TB1194.
Ultrafiltration: P-Series
refer to Cleaning Guidelines Technical Bulletin TB1194.
Reverse Osmosis: S-Series
Typical Operating Flux
5-20GFD (8-34 LMH)
Maximum Operating Pressure
600 psi (4,137 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH Range
Continuous operation: 3.0-10.0,
Clean-In-Place (CIP): 1.0 – 11.51
Maximum Pressure Drop
Over an element 15psi (103kPa)
Chlorine Tolerance
500+ ppm x hours,
Dechlorination recommended
1 Please
1 Please
Typical Operating Flux
5-20GFD (8-34 LMH)
Maximum Operating Pressure
200 psi (1,379 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH Range
Continuous operation: 3.0-10.0,
Clean-In-Place (CIP): 1.0 – 13.01
Maximum Pressure Drop
Over an element: 15psi (103kPa)
Chlorine Tolerance
5,000+ ppm x days
1 Please
refer to Cleaning Guidelines Technical Bulletin TB1194.
Ultrafiltration: M-Series
refer to Cleaning Guidelines Technical Bulletin TB1194.
Nanofiltration: D-Series
Typical Operating Flux
5-20GFD (8-34 LMH)
Maximum Operating Pressure
600 psi (4,137 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH Range
Continuous operation: 3.0-10.0,
Clean-In-Place (CIP): 2.0 – 11.01
Typical Operating Flux
5-20GFD (8-34 LMH)
Maximum Operating Pressure
100 psi (1,379 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH Range
Continuous operation: 3.0 - 10.0
Clean-In-Place (CIP): 2.0 - 11.01
Maximum Pressure Drop
Over an element: 15psi (103kPa)
Chlorine Tolerance
8,000+ ppm x days
Maximum Pressure Drop
Over an element 15psi (103kPa)
1 Please
Chlorine Tolerance
500+ ppm x hours,
Dechlorination recommended
Microfiltration: J-Series
1 Please
refer to Cleaning Guidelines Technical Bulletin TB1194.
Nanofiltration: Duracid
Typical Operating Flux
5 – 14 GFD (9 – 24 LMH)
Maximum Operating Pressure
600 psi (4,137 kPa)
Maximum Temperature
Continuous operation: 158°F (70°C)
Clean-In-Place (CIP): 158°F (70°C)
pH Range
Continuous operation: < 9.0,
Clean-In-Place (CIP): < 9.0
Maximum Pressure Drop
Over an element 15psi (103kPa)
Chlorine Tolerance
500 ppm x hours,
Dechlorination recommended
Page 2
refer to Cleaning Guidelines Technical Bulletin TB1194.
Typical Operating Flux
5-20GFD (8-34 LMH)
Maximum Operating Pressure
100 psi (1,379 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)
pH Range
Continuous operation: 3.0-10.0,
Clean-In-Place (CIP): 1.0 – 13.01
Maximum Pressure Drop
Over an element: 15psi (103kPa)
Chlorine Tolerance
5,000+ ppm x days
1 Please
refer to Cleaning Guidelines Technical Bulletin TB1194.
Fact Sheet