Fact Sheet Biotech Elements Small Size Spiral-wound Elements for Lab Testing The Biotech Test product family includes RO, NF, UF and MF membranes. These small elements are used for trials when the amount of feed liquid available is limited. The Biotech Test Elements are made with high temperature stable construction materials. The maximum recommended operating temperature is 50°C (122°F). Operation at temperature above 50°C (122°F) is possible however permeability will be reduced by irreversible compaction. The Biotech Test Elements feature a Durasan* Cage patented Outerwrap, a 34 mil spacer and polysulfone parts. Table 1B: Element Specification – Nanofiltration Membrane Model D-Series Thin-Film Membrane (TFM*) Duracid Series Minimum Membrane Area Rejection1,2 ft2 (m2) Outerwrap Part Number DK1812 98% MgSO4 4.0 (0.38) Cage 1255117 DL1812 96% MgSO4 4.0 (0.38) Cage 3051745 DURACID NF1812 98% MgSO4 4.0 (0.38) Cage 3052540 Average salt rejection after 24 hours operation. 2 Testing conditions: 2,000ppm MgSO solution at 110psi (760kPa) operating pres4 sure, 25°C (77°F), pH 7.5 and 15% recovery. 1 Table 1C: Element Specification – Ultra and Microfiltration Membrane Figure 1: Element Dimensions Diagram – Female G-Series Thin-Film Membrane (TFM*) M-Series (Hydrophilic Polyacrylonitrile PAN) P-Series (Polyethersulfone PES) J-Series (Polyvinylidene difluoride PVDF) Table 1A: Element Specification – Reverse Osmosis Membrane A-Series and S-Series Thin-Film Membrane (TFM*) Minimum Rejection1 Membrane Area ft2 (m2) Outerwrap Part Number 99% NaCl2 4.0 (0.38) Cage 3051741 AG1812HR 99.3% NaCl2 4.0 (0.38) Cage 3062684 AG1812LF 99% NaCl2 4.0 (0.38) Cage 3062685 AK1812 98% NaCl2 4.0 (0.38) Cage 3051742 AP1812 92% NaCl3 4.0 (0.38) Cage 3148691 SE1812 97.5% NaCl4 4.0 (0.38) Cage 3051750 Model AG1812 Average salt rejection after 24 hours operation. 2 Testing conditions: 2,000ppm NaCl solution at 225psi (1,551kPa) operating pressure, 25°C (77°F), pH 7.5 and 15% recovery. 3 Testing conditions: 500ppm NaCl solution at 75psi (520kPa) operating pressure, 25°C (77°F), pH 7.5 and 15% recovery. 4 Testing conditions: 2000ppm NaCl solution at 425psi (2930kPa) operating pressure, 25°C (77°F), pH 7.5 and 15% recovery. 1 MWCO (Dalton) Membrane area ft2 (m2) Outerwrap Part Number GE1812 1,000 4.0 (0.38) Cage 1255124 GH1812 2,500 4.0 (0.38) Cage 1255123 GK1812 3,500 4.0 (0.38) Cage 1255122 MW1812 30,000 4.0 (0.38) Cage 1255107 PT1812 5,000 4.0 (0.38) Cage 3051748 PW1812 20,000 4.0 (0.38) Cage 3051749 JX1812 0.3 micron 4.0 (0.38) Cage 1255108 Model Table 2: Dimensions and Weight Model All 1812 Dimensions, inches (cm) Boxed A B C Weight lbs (kg) 12 (30.48) 0.625 (1.59) 1.85 (4.7) 0.15 (0.3) Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”. * Trademark of General Electric Company; may be registered in one or more countries. ©2017, General Electric Company. All rights reserved. FSpsBiotechTestElem_EN.docx May-17 Table 3: Operating and CIP parameters Reverse Osmosis: A-Series Ultrafiltration: G-Series Typical Operating Flux 5-20GFD (8-34 LMH) Maximum Operating Pressure 400 psi (2,760 kPa) Maximum Temperature Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C) Typical Operating Flux 5-20GFD (8-34 LMH) Maximum Operating Pressure 600 psi (4,137 kPa) Maximum Temperature Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C) pH Range Continuous operation: 2.0-10.0, Clean-In-Place (CIP): 1.0 – 13.01 pH Range Continuous operation: 3.0-10.0, Clean-In-Place (CIP): 1.0 – 13.01 Maximum Pressure Drop Over an element 15psi (103kPa) Chlorine Tolerance 20-50 ppm x days Maximum Pressure Drop Over an element 15psi (103kPa) Chlorine Tolerance 500+ ppm x hours, Dechlorination recommended 1 Please refer to Cleaning Guidelines Technical Bulletin TB1194. Ultrafiltration: P-Series refer to Cleaning Guidelines Technical Bulletin TB1194. Reverse Osmosis: S-Series Typical Operating Flux 5-20GFD (8-34 LMH) Maximum Operating Pressure 600 psi (4,137 kPa) Maximum Temperature Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C) pH Range Continuous operation: 3.0-10.0, Clean-In-Place (CIP): 1.0 – 11.51 Maximum Pressure Drop Over an element 15psi (103kPa) Chlorine Tolerance 500+ ppm x hours, Dechlorination recommended 1 Please 1 Please Typical Operating Flux 5-20GFD (8-34 LMH) Maximum Operating Pressure 200 psi (1,379 kPa) Maximum Temperature Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C) pH Range Continuous operation: 3.0-10.0, Clean-In-Place (CIP): 1.0 – 13.01 Maximum Pressure Drop Over an element: 15psi (103kPa) Chlorine Tolerance 5,000+ ppm x days 1 Please refer to Cleaning Guidelines Technical Bulletin TB1194. Ultrafiltration: M-Series refer to Cleaning Guidelines Technical Bulletin TB1194. Nanofiltration: D-Series Typical Operating Flux 5-20GFD (8-34 LMH) Maximum Operating Pressure 600 psi (4,137 kPa) Maximum Temperature Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C) pH Range Continuous operation: 3.0-10.0, Clean-In-Place (CIP): 2.0 – 11.01 Typical Operating Flux 5-20GFD (8-34 LMH) Maximum Operating Pressure 100 psi (1,379 kPa) Maximum Temperature Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C) pH Range Continuous operation: 3.0 - 10.0 Clean-In-Place (CIP): 2.0 - 11.01 Maximum Pressure Drop Over an element: 15psi (103kPa) Chlorine Tolerance 8,000+ ppm x days Maximum Pressure Drop Over an element 15psi (103kPa) 1 Please Chlorine Tolerance 500+ ppm x hours, Dechlorination recommended Microfiltration: J-Series 1 Please refer to Cleaning Guidelines Technical Bulletin TB1194. Nanofiltration: Duracid Typical Operating Flux 5 – 14 GFD (9 – 24 LMH) Maximum Operating Pressure 600 psi (4,137 kPa) Maximum Temperature Continuous operation: 158°F (70°C) Clean-In-Place (CIP): 158°F (70°C) pH Range Continuous operation: < 9.0, Clean-In-Place (CIP): < 9.0 Maximum Pressure Drop Over an element 15psi (103kPa) Chlorine Tolerance 500 ppm x hours, Dechlorination recommended Page 2 refer to Cleaning Guidelines Technical Bulletin TB1194. Typical Operating Flux 5-20GFD (8-34 LMH) Maximum Operating Pressure 100 psi (1,379 kPa) Maximum Temperature Continuous operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C) pH Range Continuous operation: 3.0-10.0, Clean-In-Place (CIP): 1.0 – 13.01 Maximum Pressure Drop Over an element: 15psi (103kPa) Chlorine Tolerance 5,000+ ppm x days 1 Please refer to Cleaning Guidelines Technical Bulletin TB1194. Fact Sheet
© Copyright 2026 Paperzz