The Benefits of Installing ZETTLER Technology into an Auditorium In a small auditorium the fire detection and alarm system could simply comprise of a manual system. In larger premises, with greater occupancy, the system should incorporate automatic detectors used in critical areas and in escape routes. In the largest and more complex auditoriums, full detection coverage is beneficial. The reliability of the fire detection system is paramount, as its primary function is to protect life. As the system is likely to incorporate sounders, precautions must be taken against creating panic when the auditorium is occupied by members of the public. In such cases, two operating modes should be included; one for when the auditorium is occupied or in use by the public and one for when it is not use and likely to be empty. The ZETTLER PROFILE range of control panels incorporates MZX Technology, a complete system from a single manufacturer designed to provide optimum performance at all times. Some of the systems key features are highlighted below. The Benefits of Installing ZETTLER Technology into an Auditorium / / Risk: During performances / / Risk: In a large space occupied by there can be a presence of theatrical smoke or fog, (fog is created by pumping one of a variety of different glycol or glycol/water mixtures, referred to as fog fluid, into a heat exchanger). The effects can vary. It can lie at a low level or it may rise and dissipate at a higher level. This phenomenon, however, can easily create unwanted alarms. Smart fire detection software from ZETTLER is capable of differentiating between this type of event and a real fire, allowing the sensors to remain active during a performance. The risk of fire undoubtedly increases during the performance, given the amount of electrical equipment operating at the time. / / Solution: / / Solution: hundreds of people at any one time, there is a high risk and when a problem occurs, swift action is required. There is not often time to wait for an alarm engineer to be dispatched, as this can incur further delay. During this time, if the staff are evacuated or stood down and the show stops, costs soon escalate. Auditoriums usually have a resident engineer who is available to provide first line cover and perhaps fix the problem or provide a temporary solution. Either way the engineer would need to be competent, have good knowledge of the system and a level of access to the system. / / Solution: By installing the 850PC triple sensing detector from ZETTLER both front and backstage, the auditorium is protected to the highest level, as heat, smoke and carbon monoxide are monitored. Monitoring levels of carbon monoxide is - an important factor in an auditorium where much of the materials will have a high carbon content. The added benefit of the 850PC is that it has a built-in resilience to stage smoke and if there is no carbon monoxide present it can identify that there is no real fire present. The 850 series of sensors are available in 10 standard colours, to match most decors and are available with and without an integral short circuit isolator. They use sophisticated digital signalling to ensure reliable communications with the ZETTLER PROFILE control panel. ZETTLER PROFILE is a powerful fire detection and alarm system using MZX Technology. The system is highly resilient to external factors, such as electrical noise or sources of false alarm. / / The Touchscreen Graphical Guided User Interface (GUI) has context sensitive help and has been ergonomically engineered so that every operation is made easy, even to non-fire experts. Touch sensitive LED’s provide detailed status information and an integral help file ensures a fast response to all incoming events. The system combines ease of use with high performance and through innovation brings lifetime cost benefits to end users. On-screen site floor plans display devices in alarm or fault and are site configurable, so are constantly up / / to date. ZETTLER PROFILE control panels are available as single, 2-4, 4-16 and 4-32 loop models (with appropriate expansion modules). There is also a range of fully functional repeater panels offering a number of options, including a compact DC repeater, an 80 zone AC version or 40 and 80 way zonal displays. / / Risk: High level fire alarm sounders can initiate panic in public areas such as an auditorium. Alerting staff to a possible outbreak of fire in the first instance is a suitable alternative. By specifying and installing MZX Technology, sounders and beacons can be combined within a single unit, in both the loop powered Symphony range of wall mounted units and the AV sounder beacon base. Sounders and beacons are addressed, which means, although installed on the same cables, they can be programmed when to operate and at what volume. The volume is set in the software so some sounders can be set at lower levels than others, or even turned off, leaving only the flashing beacon operating. This allows the designer to be flexible when designing the system, whilst the installer and user do not incur extra costs for additional wiring. All loop powered sounders incorporate integral short circuit isolators, providing maximum integrity. Risk: What happens if by accident the system is activated? This is still referred to as an unwanted alarm. The incident, whilst not really being a malfunction, can still cause the same amount of disruption. To avoid unnecessary interruption to a performance or evacuation of the audience, incidents will often be investigated before evacuation takes place. When taking this course of action speed is of the essence, as delays will undoubtedly increase the risk to all occupants. Solution: Any investigation needs to be carried out quickly and under strict controls ensuring that time limits are in place. MZX Technology provides essential components to ensure a quick and accurate investigation of an alarm from a detector. Every ZETTLER PROFILE control panel has an investigate delay programme ensuring that a procedure is followed within approved time constraints. ZETTLER, is a leading brand of fire detection, security, and care communications products in the European market. The ZETTLER fire detection product line includes a wide range MZX TECHNOLOGY EN54 CPR approved fire detection products carrying approvals and cross-listings, including VdS and NF, for all European countries. The ZETTLER care communications product line is a technology leader providing the latest IP based Nursecall, Emergency Call, Communication and Management solutions for care homes, hospitals, prisons, and related markets. The ZETTLER product lines are available through ZETTLER dealers as well as many Tyco offices around the world. For more information, visit www.tycoemea.com TYZETENAUDIT (10/16)
© Copyright 2026 Paperzz