Toilet Room Grab Bars

Toilet Room Grab Bars
SUTTER HEALTH – PHYSICAL ACCESS COMPLIANCE
AUTHOR: BILL ZELLMER
APPLICABLE CODES: 2010 ADA & 2013 CBC
CBC CODE SECTIONS: 11B-604.5 AND 11B-609
H2-105
ISSUE DATE:
REVISIONS:
H2 NUMBER
7-28-2015
N/A
A: SIDE GRAB BAR: RECOMMEND 4 FEET TO 0 INCHES LONG X 1 ½ INCHES O.D. GRAB BAR, PLACED WITH NEAR END AT 10 INCHES
FROM BACK WALL. CODE REQUIRES MINIMUM 3 FEET TO 6 INCH LONG GRAB BAR WITH FAR END AT 54 INCHES MINIMUM
FROM BACK WALL, AND FAR END 2 FEET TO 0 INCHES BEYOND FRONT END OF TOILET. NOTE: MEASUREMENTS TO BE TAKEN
FROM CENTER OF THE ROUND BAR.
B: REAR GRAB BAR: RECOMMEND 3 FEET TO 6 INCH LONG X 1 ½ INCH O.D. GRAB BAR, PLACED WITH SHORT END AT 1 FOOT TO 2
INCHES FROM CENTERLINE OF TOILET. CODE REQUIRES: MINIMUM 3 FEET TO 0 INCHES LONG GRAB BAR WITH SHORT END
MINIMUM 12 INCHES FROM CENTERLINE OF TOILET AND WIDE END MINIMUM 2 FEET TO 0 INCHES FROM CENTERLINE OF
TOILET.
C: RECOMMEND SETTING TOP OF GRAB BAR AT 34 INCHES ABOVE FLOOR (2 FEET TO 10 INCHES). CODE REQUIRES THAT TOP OF
GRAB BAR BE SET BETWEEN 33 INCHES AND 36 INCHES ABOVE FLOOR.
D: CODE REQUIRES THAT GRAB BAR BE SET WITH A 1 ½ INCH GAP FROM WALL TO EDGE OF GRAB BAR.