7IOÅDK9JÅ?HÅ;7IKH;C;DJI ;JÅKB8 Å;CFI Ų Å?HÅ;BE9?JO The best way to take air measurements for A/C is at HLWKHUHQGRIWKHHYDSRUDWRU1RZ)LHOGSLHFHSURYLGHV WRROVIRUWHFKVWRWDNHWKHPHDVLO\DQGDFFXUDWHO\ 1HZ,Q'XFW+RWZLUH$QHPRPHWHUVDQG3V\FKURPHWHUVPDNHLWHDVLHU WRJHWDLUPHDVXUHPHQWVZKHUHWHFKVQHHGWKHP²LQWKHGXFW (DVLHUWRWDNHPHDVXUHPHQWVQHDUWKHHYDSRUDWRU ´WHOHVFRSLQJSUREHWRWUDYHUVHDQ\GXFWVL]H +DQGVIUHHWHVWLQJZLWKVWDELOL]LQJFRQHDQGPDJQHWLFKDQJHU ´GLDPHWHUSUREHIRUVPDOOKROHV $FFHVVRU\KHDGVFRPSDWLEOHZLWK)LHOGSLHFHZLUHOHVVPHWHUV 5XOHUHWFKHGSUREHIRUWUDYHUVLQJ Hot-wire Anemometer DQG3V\FKURPHWHULQ2QH The AAT3 InDuct Hot-wire Anemometer and Psychrometer gets into ducts easily for measurement of temperatures, %RH, and air velocity. ce HVAC Guide® System Analyzer’s These measurements go hand in hand with the Fieldpiece Superheat, TEET, CheckMe!, and CFM switch positions for faster, more accurate and convenient diagnostics. 5+DQGDLUYHORFLW\ 0HDVXUHVWHPSHUDWXUHV5+DQGDLUYHORFLW\ Z &DOFXODWHVZHWEXOEDQGGHZ point temperatures piece Sends wireless signal to Fieldpiece 0’ away* wireless meters from up to 100’ *UHDWSDUWQHUZLWK+9$&*XLGH® System Analyzer for full system diagnosis *ET2W wireless transmitter turns any Fieldpiece Accessory Head into a wireless device when synced with Fieldpiece wireless enabled meters. &)0:LWKRXWD+RRG The STA2 InDuct, Hot-wire Anemometer calculates CFM from air velocity and free area. Averaging air velocity from several measurements and inputting free area are a snap. With in-duct traversing it’s an excellent alternative to costly, bulky hoods for air balancing. )DVWUHVSRQVHWLPH 'XDOGLVSOD\WRVKRZDQ\FRPELQDWLRQRIUHDOWLPH&)0DLUYHORFLW\RUWHPS 0LQLPL]HVHIIHFWVRIWXUEXOHQFHZLWKWLPHRUWHVWSRLQWDYHUDJHV )DVWDFFXUDWHWHPSV ZZZ¿HOGSLHFHFRP Convenient Wet Bulb 0HDVXUHPHQWV Now you can get in-duct wet bulb and dew point measurements in the convenience of a Fieldpiece Accessory Head. Not only does the ARH5 make it easy to get in-duct measurements near the evaporator, but now techs can get wireless indoor wet bulb measurements in real-time, while they are making a adjustments at the condenser. 0HDVXUHVWHPSHUDWXUHVDQG5+ &DOFXODWHVZHWEXOEDQGGHZSRLQWWHPSHUDWXUHV Sends wireless signal to Fieldpiece wireless meters f from up to 100’ away* )DVWDFFXUDWHUHVXOWVIRUWDUJHWVXSHUKHDWDQG )D targ xit temp target exap exit The wireless HG3 HVAC Guide® Th Sy System Analyzer can receive up 12 measurements at the same to 1 time from an ET2W Wireless Transmitter connected to any Tran Accessory Head. Wirelessly Acce sends indoor temperatures to unit while techs are the outdoor out adjusting the refrigerant charge. adjustin *ET2W wireless transmitter turns any Fieldpiece Accessory Head into a wireless device when synced with Fieldpiece wireless enabled meters. (DV\7DUJHW6XSHUKHDW Take supply/return temperatures, %RH, wet bulb and dew point measurements from inside the duct, near the evaporator. The STA2 InDuct Psychrometer is a great tool to properly charge ¿[HGUHVWULFWRUV\VWHPVE\TXLFNO\GHWHUPLQLQJWKHWDUJHWVXSHUKHDW DQGWRKHOSGHWHUPLQHRSWLPXPDLUÀRZDFURVVWKHHYDSRUDWRUZLWKD target evaporator exit temperature test. 0HDVXUHVWHPSHUDWXUHVDQG5+ &DOFXODWHVZHWEXOEDQGGHZSRLQWWHPSHUDWXUHV 4XLFNO\SURYLGHVWDUJHWVXSHUKHDW +HOSVGHWHUPLQHRSWLPXPDLUÀRZDFURVVWKHHYDSRUDWRU with target evaporator exit temperature test )LHOGSLHFH,Q'XFW3URGXFW6SHFLÀFDWLRQV STA2 ARH5 AAT3 SRH3 Measures: Air Velocity, Temperature Measures: Temperature, %RH Measures: Air Velocity, Temperature, %RH Measures: Temperature, %RH Calculates: CFM Calculates: Wet Bulb, Dew Point Calculates: Wet Bulb, Dew Point Battery Life: 20-35 hours approx. (alkaline) Auto Power Off: after 15 minutes of inactivity if APO is active. Velocity Calculates (when connected to the HG3): Target Superheat, Target Evaporator Exit Temperature Auto Power Off: after 15 minutes of inactivity if APO is active. Auto Power Off: Approx. 15 minutes Battery Life: 20 -35 hours typical Battery Life: 150 hours typical (alkaline) Range: 40-3940 fpm (0.20-20.00 m/s) Temperature Auto Power Off: after 15 minutes of inactivity if APO is active. Velocity Units: fpm, m/s, km/hr, mph Temperature Calculates (when connected to the HG3): Target Superheat, Target Evaporator Exit Temperature, CFM Calculates: Wet Bulb, Target Superheat, Target Evaporator Exit Temperature Sensor Type: Precision thermistor Range: -4°F to 140°F (-20°C to 60°C) Sensor Type: Thermistor Relative Humidity Range: -4°F to 140°F (-20°C to 60°C) Sensor Type: Capacitance SRO\PHU¿OP Range: 0% to 100%RH Range: 40-3940 ft/min (0.20-20.00 m/s) Battery Life: 150 hours typical (alkaline) Low Battery Indication: is displayed when the battery voltage drops below the operating level. Temperature Sensor Type: Precision thermistor Note: to use full range AAT3 must be connected to a DMM with a 4000 mVDC range or greater. Range: -4°F to 140°F (-20°C to 60°C) Relative Humidity Relative Humidity Range: 0% to 100% RH Sensor Type: Capacitance SRO\PHU¿OP Temperature Range: 0% to 100%RH Range: -4°F to 140°F (-20°C to 60°C) ZZZ¿HOGSLHFHFRP 714-634-1844 Professional-grade instruments IRU+9$&5¿HOGVHUYLFH
© Copyright 2026 Paperzz