Fieldpiece InDuct Brochure.indd

7IOÅDK9JÅ?HÅ;7IKH;C;DJI
;JÅKB8…Å;CFI…Ų…Å?HÅ;BE9?JO
The best way to take air measurements for A/C is at
HLWKHUHQGRIWKHHYDSRUDWRU1RZ)LHOGSLHFHSURYLGHV
WRROVIRUWHFKVWRWDNHWKHPHDVLO\DQGDFFXUDWHO\
1HZ,Q'XFW+RWZLUH$QHPRPHWHUVDQG3V\FKURPHWHUVPDNHLWHDVLHU
WRJHWDLUPHDVXUHPHQWVZKHUHWHFKVQHHGWKHP²LQWKHGXFW
‡(DVLHUWRWDNHPHDVXUHPHQWVQHDUWKHHYDSRUDWRU
‡´WHOHVFRSLQJSUREHWRWUDYHUVHDQ\GXFWVL]H
‡+DQGVIUHHWHVWLQJZLWKVWDELOL]LQJFRQHDQGPDJQHWLFKDQJHU
‡´GLDPHWHUSUREHIRUVPDOOKROHV
‡$FFHVVRU\KHDGVFRPSDWLEOHZLWK)LHOGSLHFHZLUHOHVVPHWHUV
‡5XOHUHWFKHGSUREHIRUWUDYHUVLQJ
Hot-wire Anemometer
DQG3V\FKURPHWHULQ2QH
The AAT3 InDuct Hot-wire Anemometer and Psychrometer gets into ducts easily for
measurement of temperatures, %RH, and air velocity.
ce HVAC Guide® System Analyzer’s
These measurements go hand in hand with the Fieldpiece
Superheat, TEET, CheckMe!, and CFM switch positions for faster, more accurate and
convenient diagnostics.
5+DQGDLUYHORFLW\
‡ 0HDVXUHVWHPSHUDWXUHV5+DQGDLUYHORFLW\
Z
‡ &DOFXODWHVZHWEXOEDQGGHZ
point temperatures
piece
Sends wireless signal to Fieldpiece
0’ away*
wireless meters from up to 100’
‡ *UHDWSDUWQHUZLWK+9$&*XLGH®
System Analyzer for full system diagnosis
*ET2W wireless transmitter turns
any Fieldpiece Accessory Head into
a wireless device when synced with
Fieldpiece wireless enabled meters.
&)0:LWKRXWD+RRG
The STA2 InDuct, Hot-wire Anemometer calculates CFM from
air velocity and free area. Averaging air velocity from several
measurements and inputting free area are a snap.
With in-duct traversing it’s an excellent alternative to costly, bulky
hoods for air balancing.
‡)DVWUHVSRQVHWLPH
‡'XDOGLVSOD\WRVKRZDQ\FRPELQDWLRQRIUHDOWLPH&)0DLUYHORFLW\RUWHPS
‡0LQLPL]HVHIIHFWVRIWXUEXOHQFHZLWKWLPHRUWHVWSRLQWDYHUDJHV
‡)DVWDFFXUDWHWHPSV
ZZZ¿HOGSLHFHFRP‡
Convenient Wet Bulb
0HDVXUHPHQWV
Now you can get in-duct wet bulb and dew point measurements
in the convenience of a Fieldpiece Accessory Head.
Not only does the ARH5 make it easy to get in-duct measurements
near the evaporator, but now techs can get wireless indoor
wet bulb measurements in real-time, while they are making
a
adjustments
at the condenser.
‡0HDVXUHVWHPSHUDWXUHVDQG5+
‡&DOFXODWHVZHWEXOEDQGGHZSRLQWWHPSHUDWXUHV
Sends wireless signal to Fieldpiece wireless meters
f
from
up to 100’ away*
‡‡)DVWDFFXUDWHUHVXOWVIRUWDUJHWVXSHUKHDWDQG
)D
targ
xit temp
target exap exit
The wireless HG3 HVAC Guide®
Th
Sy
System
Analyzer can receive up
12 measurements at the same
to 1
time from an ET2W Wireless
Transmitter connected to any
Tran
Accessory Head. Wirelessly
Acce
sends indoor temperatures to
unit while techs are
the outdoor
out
adjusting the refrigerant charge.
adjustin
*ET2W wireless transmitter turns
any Fieldpiece Accessory Head into
a wireless device when synced with
Fieldpiece wireless enabled meters.
(DV\7DUJHW6XSHUKHDW
Take supply/return temperatures, %RH, wet bulb and dew point
measurements from inside the duct, near the evaporator.
The STA2 InDuct Psychrometer is a great tool to properly charge
¿[HGUHVWULFWRUV\VWHPVE\TXLFNO\GHWHUPLQLQJWKHWDUJHWVXSHUKHDW
DQGWRKHOSGHWHUPLQHRSWLPXPDLUÀRZDFURVVWKHHYDSRUDWRUZLWKD
target evaporator exit temperature test.
‡0HDVXUHVWHPSHUDWXUHVDQG5+
‡&DOFXODWHVZHWEXOEDQGGHZSRLQWWHPSHUDWXUHV
‡4XLFNO\SURYLGHVWDUJHWVXSHUKHDW
‡+HOSVGHWHUPLQHRSWLPXPDLUÀRZDFURVVWKHHYDSRUDWRU with target evaporator exit temperature test
)LHOGSLHFH,Q'XFW3URGXFW6SHFLÀFDWLRQV
STA2
ARH5
AAT3
SRH3
Measures: Air Velocity, Temperature
Measures: Temperature, %RH
Measures: Air Velocity, Temperature,
%RH
Measures: Temperature, %RH
Calculates: CFM
Calculates: Wet Bulb, Dew Point
Calculates: Wet Bulb, Dew Point
Battery Life: 20-35 hours approx.
(alkaline)
Auto Power Off: after 15 minutes of
inactivity if APO is active.
Velocity
Calculates (when connected to
the HG3): Target Superheat, Target
Evaporator Exit Temperature
Auto Power Off: after 15 minutes of
inactivity if APO is active.
Auto Power Off: Approx. 15 minutes
Battery Life: 20 -35 hours typical
Battery Life: 150 hours typical
(alkaline)
Range: 40-3940 fpm (0.20-20.00 m/s)
Temperature
Auto Power Off: after 15 minutes of
inactivity if APO is active.
Velocity
Units: fpm, m/s, km/hr, mph
Temperature
Calculates (when connected to
the HG3): Target Superheat, Target
Evaporator Exit Temperature, CFM
Calculates: Wet Bulb, Target
Superheat, Target Evaporator Exit
Temperature
Sensor Type: Precision thermistor
Range: -4°F to 140°F (-20°C to 60°C)
Sensor Type: Thermistor
Relative Humidity
Range: -4°F to 140°F (-20°C to 60°C)
Sensor Type: Capacitance
SRO\PHU¿OP
Range: 0% to 100%RH
Range: 40-3940 ft/min (0.20-20.00
m/s)
Battery Life: 150 hours typical
(alkaline)
Low Battery Indication: is displayed
when the battery voltage drops below
the operating level.
Temperature
Sensor Type: Precision thermistor
Note: to use full range AAT3 must
be connected to a DMM with a 4000
mVDC range or greater.
Range: -4°F to 140°F (-20°C to 60°C)
Relative Humidity
Relative Humidity
Range: 0% to 100% RH
Sensor Type: Capacitance
SRO\PHU¿OP
Temperature
Range: 0% to 100%RH
Range: -4°F to 140°F (-20°C to 60°C)
ZZZ¿HOGSLHFHFRP
714-634-1844
Professional-grade instruments
IRU+9$&5¿HOGVHUYLFH