High-efficiency Drinking Water Pump Rio-Eco Therm N Type Series Booklet Legal information/Copyright Type Series Booklet Rio-Eco Therm N All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. © KSB Aktiengesellschaft, Frankenthal 24.08.2015 Contents Contents Building Services: Heating ................................................................................................................................. 4 Variable-speed Drinking Water Pumps ......................................................................................................................... 4 Rio-Eco Therm N ........................................................................................................................................................ 4 Main applications ................................................................................................................................................ 4 Fluids handled ...................................................................................................................................................... 4 Operating data .................................................................................................................................................... 4 Designation .......................................................................................................................................................... 4 Design details ....................................................................................................................................................... 4 Materials .............................................................................................................................................................. 5 Product benefits ................................................................................................................................................. 5 Certifications ........................................................................................................................................................ 5 Selection information .......................................................................................................................................... 5 Programme overview / selection tables ............................................................................................................. 7 Technical data ...................................................................................................................................................... 7 Selection chart ..................................................................................................................................................... 8 Characteristic curves ............................................................................................................................................ 8 Dimensions ......................................................................................................................................................... 10 Flange design ..................................................................................................................................................... 11 Installation information .................................................................................................................................... 11 Scope of supply .................................................................................................................................................. 11 Accessories ......................................................................................................................................................... 12 3 Building Services: Heating Variable-speed Drinking Water Pumps Building Services: Heating Code Variable-speed Drinking Water Pumps 100 Rio-Eco Therm N Design details Design Description 30 = R 1 1/4 40 ... 65 = DN 40 ... DN 65 Head in m x 10 (example 10 m = 100) ▪ Highly efficient, maintenance-free wet rotor pump (glandless) ▪ Screw-ended or flanged ▪ Permanent magnet motor ▪ Continuously variable differential pressure control Operating modes ▪ Automatic mode with variable differential pressure ▪ Open-loop control mode with external 0 - 10 V setpoint signal for speed ▪ Open-loop control mode with manual setpoint input Automatic functions ▪ Continuous output adjustment depending on the operating mode ▪ Deblocking function ▪ Soft start (slow start) Main applications ▪ Drinking water circulation systems ▪ Similar systems in industry and building services applications (e.g. cooling water circulation) ▪ Full motor protection Manual functions ▪ Setting the operating mode ▪ Setting the differential pressure setpoint ▪ Setting the speed level Fluids handled ▪ Drinking water and water for the food and beverage industry, as per German 2001 drinking water regulations External control functions ▪ Control input "start/stop" ▪ Control input for remote speed adjustment 0-10 V Signalling and display functions Operating data ▪ General fault indication (volt-free changeover contact) Operating properties Characteristic Flow rate Head Fluid temperature Ambient temperature Operating pressure Connection Value Q [m3/h] Screw-ended pumps: ≤ 12 Flanged pumps: ≤ 38 Q [l/s] Screw-ended pumps: ≤ 3.33 Flanged pumps: ≤ 10.6 H [m] ≤ 12 T [°C] Heating water: -10 to +110 Drinking water (≤ 20 °dH): ≤ 80 T [°C] ≤ 40 p [bar] ≤ 10 Screw-end: R 1 1/4 Flange: DN 40 - DN 65 ▪ Fault indication, display of error codes Interfaces ▪ Serial digital Modbus RTU interface for connecting higherlevel automation systems via the RS485 system bus Twin pump management ▪ Duty/stand-by mode with timer-controlled pump changeover every 24 hours and automatic changeover in the event of a fault Drive ▪ Electronically commutated synchronous motor with permanent magnet rotor ▪ 1~230 VAC, 50/60 Hz ▪ IP42 enclosure Designation Example: Rio-Eco Therm N 30-100 Designation key Code Rio Eco Therm N 30 Description Type series High-efficiency pump Drinking water pump New generation Nominal diameter of pipe connection ▪ Thermal class F ▪ Temperature class TF 110 ▪ Variable speed electric drives to EN 61800-3 EMC requirements ▪ Interference emission standard EN 55014-1 or EN 61000-6-3 ▪ Interference immunity standard EN 55014-2 or EN 61000-6-2 Bearings ▪ Product-lubricated special plain bearing 4 Rio-Eco Therm N Building Services: Heating Variable-speed Drinking Water Pumps Materials Overview of available materials Component Volute casing Shaft Impeller Bearings Material Bronze Stainless steel 1.4034 Plastic (PSU - 30 % glass fibre) Carbon, resin-impregnated Product benefits ▪ Maximum savings of operating costs by high-efficiency motor combined with speed control ▪ "All-in" concept saves costs ▪ Design principle ensures long service life and high level of comfort ▪ Universal use reduces storage costs Certifications Overview Label Effective in: Germany Comment All sizes Selection information Minimum pressure The minimum pressure pmin at the pump suction nozzle serves to avoid cavitation noises at an ambient temperature of +40 °C and the indicated fluid temperature Tmax. The indicated values are applicable up to 300 m above sea level. For installation at altitudes > 300 m, an allowance of 0.01 bar / 100 m must be added. Minimum pressure pmin [bar] specified for the fluid temperature [°C] Size 30-100, 30-120, 40-100, 40-120, 50-90 65-120 Fluid temperature Minimum pressure [°C] Up to 80 81 to 95 Up to 80 81 to 95 [bar] 0,5 1,5 0,8 1,5 Rio-Eco Therm N 5 Building Services: Heating Variable-speed Drinking Water Pumps Description of the characteristic curve 4,0 H [m] 3,5 4 3,0 2,5 3 2,0 a) b) 2 1,5 . 1,0 c) 0,5 0 A 1 0 1 Q [m3/h] 1,5 0,5 2 2,5 3 2 2,5 3 30 P1 [W] 25 4 a) 20 3 b) 2 15 c) 10 1 5 0 0 0,5 1 Q [m3/h] 1,5 Selection example 1 2 3 4 A Level 1 Open-loop control (n = constant) Level 2 Open-loop control (n = constant) Level 3 Open-loop control (n = constant) Level 4 Open-loop control (n ≠ constant) Point of maximum pump power output (Q x H = Pmax.) Control range a) b) Control curve, maximum head Control curve, maximum pump power output (factory setting) Control curve, minimum head c) The characteristic curve can be adjusted between a) and c) by turning the control knob. Description of the Modbus interface Description see operating manual of the pump. 6 Rio-Eco Therm N Building Services: Heating Variable-speed Drinking Water Pumps Programme overview / selection tables Features and functions Features and functions Functions Operating modes Δp-v for variable differential pressure Fixed speed operation Manual functions Setting the operating mode Setting the differential pressure setpoint Setting the speed Vent plug Automatic functions Continuous output adjustment depending on the mode of operation Deblocking function Slow start External control functions Control input for remote speed adjustment 0-10 V Control input "start/stop" Signalling and display functions Display of error codes General fault message (volt-free NC contact) Fault indicator lamp Data exchange Serial digital Modbus RTU interface for connection to a building management system via RS485 bus system Features / scope of supply Sealing elements for connection (not fitted) Installation/operating manual Technical data 30-100 30-120 40-100 40-120 50-90 65-120 R DN G R1¼ R1¼ DN 40 DN 40 DN 50 DN 65 G2 G2 DN 40 DN 40 DN 50 DN 65 PN P1 Motor protection Size [W] 6/10 6/10 6/10 6/10 6/10 6/10 22 - 250 30 - 340 30 - 350 27 - 450 30 - 350 100 - 1400 Signalling contacts Rio-Eco Therm N selection table ✘ ✘ ✘ ✘ ✘ ✘ SSM SSM SSM SSM SSM SSM Rated current Mat. No. [kg] 1~230 V [A] 0,20 - 1,55 0,25 - 2,10 0,25 - 2,20 0,22 - 2,70 0,25 - 2,30 0,90 - 9,50 29134185 29134186 29134187 29134188 29134189 29134190 8.6 8.6 12.8 16.5 13.5 36.5 ✘ = integrated motor protection SSM = general fault message Rio-Eco Therm N 7 Building Services: Heating Variable-speed Drinking Water Pumps Selection chart Rio-Eco Therm N 140 14 H [m] [kPa] 40-120 12 120 65-120 30-120 40-100 50-90 10 100 30-100 8 80 6 60 4 40 2 20 0 0 0,1 1,0 10,0 Q [m3/h] 0,1 Q [l/s] 1,0 10,0 Characteristic curves Rio-Eco Therm N 30-120 Rio-Eco Therm N 30-100 12 1~230 VAC R 1 1/4 10 H [m] 8 14 1~230 VAC R 1 1/4 12 H [m] 10 8 6 6 4 4 2 2 0 0 0 2 4 6 8 10 12 Q [m /h] 0 3 300 2 4 6 8 10 12 14 Q [m3/h] 6 8 10 12 14 Q [m3/h] 400 P1 [W] 350 P1 [W] 250 300 200 250 150 200 150 100 100 50 50 0 0 0 8 2 4 6 Rio-Eco Therm N 8 10 12 Q [m3/h] 0 2 4 Building Services: Heating Variable-speed Drinking Water Pumps Rio-Eco Therm N 40-100 Rio-Eco Therm N 50-90 12 12 1~230 VAC DN 40 10 1~230 VAC DN 50 10 H [m] H [m] 8 8 6 6 4 4 2 2 0 0 0 2 4 6 8 10 12 14 16 Q [m /h] 0 3 400 P1 [W] 350 5 10 15 20 25 Q [m3/h] 15 20 25 Q [m3/h] 400 P1 [W] 350 300 300 250 250 200 200 150 150 100 100 50 50 0 0 2 4 6 8 10 12 14 16 0 0 Q [m /h] 3 Rio-Eco Therm N 40-120 5 10 Rio-Eco Therm N 65-120 14 14 1~230 VAC DN 40 12 1~230 VAC DN 65 H [m] 12 10 10 H [m] 8 8 6 6 4 4 2 2 0 0 0 2 4 6 8 10 12 14 16 Q [m /h] 0 10 20 30 40 50 Q [m3/h] 0 10 20 30 40 50 Q [m3/h] 3 1.600 P1 [W] 1.400 500 450 P1 [W] 400 1.200 350 1.000 300 250 800 200 600 150 400 100 200 50 0 0 0 2 4 6 8 10 12 14 16 Q [m /h] 3 Rio-Eco Therm N 9 Building Services: Heating Variable-speed Drinking Water Pumps Dimensions Dimensions of screw-ended pump 75 35 150 90 H 230 G Screw-ended pumps Dimensions [mm] Size 30-100 30-120 R 1 1/4 1 1/4 G 2 2 H 180 180 Dimensions of flanged pump a b c e H d Flanged pump Dimensions [mm] Size 40-100 40-120 50-90 65-120 10 DN 40 40 50 65 a 215 215 225 235 b 75 75 75 93 Rio-Eco Therm N c 75 75 95 105 d 150 150 160 180 e 125 125 140 170 H 250 250 280 340 Building Services: Heating Variable-speed Drinking Water Pumps Flange design ØD Ø k L2 Ø k L1 Ød DN n x Ø d1 n x Ø d2 Adapter flange Dimensions [mm] Adapter flange DN 40 DN 50 DN 65 ØD 150 165 185 Ød PN 6 PN 10 PN 6 PN 10 84 99 118 ØkL1 100 110 130 ØkL2 110 125 145 n × dL1 4 × Ø14 4 × Ø14 4 × Ø14 n × dL2 4 × Ø19 4 × Ø19 4 × Ø19 Installation information Permissible installation positions Sizes Rio-Eco Therm N 30-100, 30-120, 40-100, 40-120, 50-90 Rio-Eco Therm N 65-120 Scope of supply ▪ Pump ▪ Installation/operating manual Rio-Eco Therm N 11 Building Services: Heating Variable-speed Drinking Water Pumps Accessories Electrical accessories Description Length Mat. No. [kg] Modbus data cable With preconfigured plug for Rio-Eco Therm N 5 19075536 0.2 Description Mat. No. [kg] 2 pipe unions with G 1 1/2 union nut and insert with Rp 3/4 internal thread, brass for pumps with G 1 1/2 external thread / R 3/4 pipe connection 2 pipe unions with G 1 1/2 union nut and insert with Rp 1 internal thread, brass for pumps with G 1 1/2 external thread / R 1 pipe connection 2 pipe unions with G 2 union nut and insert with Rp 1 ¹/₄ internal thread, brass for pumps with G 2 external thread / R 1 ¹/₄ pipe connection 19075563 0.2 19075564 0.2 19075565 0.2 Pipe union 12 Rio-Eco Therm N 24.08.2015 1142.51/03-EN KSB Aktiengesellschaft 67225 Frankenthal • Johann-Klein-Str. 9 • 67227 Frankenthal (Germany) Tel. +49 6233 86-0 • Fax +49 6233 86-3401 www.ksb.com
© Copyright 2026 Paperzz