HSG-2x8-8L-T5HO-M4 - Precision

IES INDOOR REPORT
PHOTOMETRIC FILENAME : HSG-2X8-8L-T5HO-M4-PH.IES
DESCRIPTION INFORMATION (From Photometric File)
IESNA:LM-63-1995
[TEST] HSG-2x8-8L-T5HO-M4-PH
[TESTLAB] PHOTOPIA 2.0.0.21
[ISSUEDATE] 08-22-06
[MANUFAC] PRECISION-PARAGON
[LUMCAT] HSG-2x8-8L-T5HO-M4
[LUMINAIRE] 14" x 48" x 5"
[LUMINAIRE] INDOOR
[LAMPCAT] 841/T5HO
[OTHER] 1876( 4.7%) 32520( 81.3%) ALMIRO04
[MORE] MIRO 4 REFLECTOR
CHARACTERISTICS
Lumens Per Lamp
Total Lamp Lumens
Luminaire Lumens
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Total Luminaire Watts
Ballast Factor
CIE Type
Spacing Criteria (0-180)
Spacing Criteria (90-270)
Spacing Criteria (Diagonal)
Basic Luminous Shape
Luminous Length (0-180)
Luminous Width (90-270)
Luminous Height
5000 (8 lamps)
40000
36547
91 %
78
468
1.00
Direct
1.30
1.16
1.28
Rectangular
8.00 ft
1.16 ft
0.00 ft
LUMINANCE DATA (cd/sq.m)
Angle In
Degrees
Average
0-Deg
Average
45-Deg
Average
90-Deg
45
55
65
75
85
19253
18812
17584
14775
7262
14248
9191
5159
1363
186
9078
5507
2784
69
139
Photometric Toolbox Professional Edition (c) copyright 1995-2009 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 1
IES INDOOR REPORT
PHOTOMETRIC FILENAME : HSG-2X8-8L-T5HO-M4-PH.IES
CANDELA TABULATION
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
0.0
22.5
45.0
67.5
90.0
16203.80016203.80016203.80016203.80016203.800
16183.30016125.50016144.60016509.10016939.600
15962.20016206.80016851.19916884.69916998.000
15554.20016224.90016641.00016849.50016812.900
15122.10016059.30016366.20016453.10016375.700
14634.50015562.40015834.50014852.40014390.700
14334.40015062.20014508.30012697.30012281.800
13316.10014255.30012636.30010862.60010091.400
12652.40013088.10010686.1008736.460 8049.920
11765.10011670.5008706.700 6428.820 5547.350
10581.3009984.110 6634.060 4327.010 3913.560
9324.730 8160.730 4555.740 3082.500 2729.770
7974.560 6218.430 3010.720 2061.110 1824.180
6421.930 4250.470 1884.340 1249.000 1016.640
4883.000 2593.980 1024.710 448.830 268.310
3304.810 1301.550 304.910 33.800
15.370
1776.210 411.320 28.520
16.040
15.070
546.980 49.900
14.000
9.490
10.440
34.930
6.630
1.850
1.090
0.770
Photometric Toolbox Professional Edition (c) copyright 1995-2009 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 2
IES INDOOR REPORT
PHOTOMETRIC FILENAME : HSG-2X8-8L-T5HO-M4-PH.IES
ZONAL LUMEN SUMMARY
Zone
Lumens
%Lamp
%Fixt
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
13187.42
20904.88
32661.82
36546.57
0.00
0.00
0.00
0.00
36546.57
33.00
52.30
81.70
91.40
0.00
0.00
0.00
0.00
91.40
36.10
57.20
89.40
100.00
0.00
0.00
0.00
0.00
100.00
Total Luminaire Efficiency = 91.40%
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
1567.39
4651.61
6968.42
7717.46
6841.18
4915.75
2782.1
960.95
141.71
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Photometric Toolbox Professional Edition (c) copyright 1995-2009 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 3
IES INDOOR REPORT
PHOTOMETRIC FILENAME : HSG-2X8-8L-T5HO-M4-PH.IES
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
Effective Floor Cavity Reflectance 0.20
RC
RW
80
70 50 30 10
70
70 50 30 10
50
50 30 10
30
50 30 10
10
50 30 10
0
0
0
1
2
3
4
5
6
7
8
9
10
109 109 109 109
101 98 94 91
93 87 82 77
86 78 71 66
80 70 63 57
74 63 56 50
68 57 50 44
64 52 45 40
59 48 41 36
56 44 37 32
52 41 34 30
106 106 106 106
99 96 93 90
91 85 80 76
84 76 70 65
78 69 62 57
72 62 55 50
67 56 49 44
62 52 45 40
58 47 40 36
54 44 37 32
51 41 34 30
102 102 102
92 89 87
82 78 75
74 69 64
66 61 56
60 54 49
55 49 44
50 44 39
46 40 36
43 37 32
40 34 29
97
88
79
71
64
58
53
49
45
42
39
93
85
77
69
63
57
52
48
44
41
38
91
80
70
60
53
47
41
37
33
30
28
97
86
76
67
59
53
48
43
39
36
33
97
85
73
63
55
49
44
39
35
32
29
93
83
74
65
58
52
47
43
39
36
33
Photometric Toolbox Professional Edition (c) copyright 1995-2009 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
93
82
71
62
55
48
43
39
35
32
29
Page 4
IES INDOOR REPORT
PHOTOMETRIC FILENAME : HSG-2X8-8L-T5HO-M4-PH.IES
POLAR GRAPH
16998
12749
8499
4250
3
2
1
Maximum Candela = 16998 Located At Horizontal Angle = 90, Vertical Angle = 10
# 1 - Vertical Plane Through Horizontal Angles (0 - 180)
# 2 - Vertical Plane Through Horizontal Angles (45 - 225)
# 3 - Vertical Plane Through Horizontal Angles (90 - 270)
Photometric Toolbox Professional Edition (c) copyright 1995-2009 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 5