1/2" BLUERIDGE SOUNDSTOP FIBERBOARD (MEETING ASTM E94-91a) SOUND BATT INSULATION TO FILL CAVITY SOUND BATT INSULATION TO FILL CAVITY SOUND BATT INSULATION TO FILL CAVITY SOUND BATT INSULATION TO FILL CAVITY GUESTROOM SIDE OF WALL SOUND BATT INSULATION TO FILL CAVITY GUESTROOM SIDE OF WALL CORRIDOR SIDE OF WALL 1/2" BLUERIDGE SOUNDSTOP FIBERBOARD (MEETING ASTM E84-91a) 5/8" TYPE "X" GYPSUM BOARD NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO DECKING OF FLOOR ABOVE 2. GYP. BD. TO STRUCTURE ABOVE- ACOUSTIC SEALANT AT PLATES 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. ALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR SOUND TRANSMISSION 5. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE SEE 2/A510 FOR DETAIL @ TUBS P1 2X6 WOOD STUD WITH INSULATION & SOUNDBOARD ON BOTH SIDES WOOD 1 HR WALL - PARTY WALL (UL-U387 CALCULATED STC 55 MIN.) SHEAR WALL SHEATHING ATTACHED DIRECTLY TO STUDS SHEAR WALL SHEATHING ATTACHED DIRECTLY TO STUDS 5/8" TYPE "X" GYPSUM BOARD 5/8" TYPE "X" GYPSUM BOARD NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO DECKING OF FLOOR ABOVE. 2. GYP. BD. TO STRUCTURE ABOVE- ACOUSTIC SEALANT AT PLATES 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. ALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR SOUND TRANSMISSION 5. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE SEE 2/A510 FOR DETAIL @ TUBS P2 P3 2X6 WOOD STUD WITH INSULATION, 7/16" RATED SHEATHING ON ONE SIDE AND SOUNDBOARD WOOD 1 HR WALL - PARTY WALL (UL-U387 CALCULATED STC 55 MIN.) 2X WOOD STUDS (SEE STRUCTURAL FOR SPACING) NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO DECKING OF FLOOR ABOVE. 2. GYP. BD. TO STRUCTURE ABOVE- ACOUSTIC SEALANT AT PLATES 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. ALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR SOUND TRANSMISSION 5. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE SEE 2/A510 FOR DETAIL @ TUBS WOOD 1 HR WALL - PARTY WALL (UL-U387 CALCULATED STC 55 MIN.) 2X WOOD STUDS (SEE STRUCTURAL FOR SPACING) 5/8" TYPE "C" GYPSUM BD EACH SIDE 2X6 WOOD STUD WITH INSULATION, 7/16" RATED SHEATHING ON BOTH SIDES AND SOUNDBOARD NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO DECKING ABOVE 2. GYP. BD. TO STRUCTURE ABOVE 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE SEE 2/A510 FOR DETAIL @ TUBS 5. ALL CORRIDOR WALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR SOUND TRANSMISSION- PROVIDE ACOUSTIC SEALANT 6. CORRIDOR WALL WITH SHEAR REQUIREMENTS SHALL HANG PLYWOOD ADDED TO ROOM SIDE IF REQUIRED BY STRUCT. 6. AT DOOR OPENINGS, OMIT RESILIENT CHANNEL AND FURR OUT WALL WITH 1/2" SHEATHING FOR DOOR FRAME BACKING. C1 WOOD 1 HR WALL - CORRIDOR (UL - U311 CALCULATED STC 55) 2X WOOD STUDS 5/8" TYPE "X" GYPSUM BD EACH SIDE 5/8" TYPE "X" GYPSUM BD. ON FINISH SIDE W1 2X4 or 2x6 (SEE PLAN) WOOD STUD WITH INSULATION WOOD 1HR WALL (UL DESIGN U333) GENERAL WALL TYPE NOTES: 1. 2. 3. 4. 5. 6. 7. TOP AND BOTTOM OF WALLS TO BE EFFECTIVELY FIRE-STOPPED; WHERE RATED WALLS OCCUR, GYP. BD. TO BE CONTINUOUS FROM FLOOR TO BOTTOM OF RATED ASSEMBLY OR DECK ABOVE. EXTERIOR WALLS: 7/16" SHEATHING SHALL ALIGN WITH EDGE OF FOUNDATION WALL. STAGGER SHEATHING JOINTS. USE MOISTURE RESISTANT CEMENTITIOUS MATERIALS @ CERAMIC TILE & WET AREASDENSARMOR PLUS FIREGUARD BOARD(TO MAINTAIN HOURLY RATING OF WALL) OR EQUAL. PROVIDE MIN. 4 MIL. V.B. ON INTERIOR (WARM) SIDE OF ALL EXTERIOR WALLS. MIN. 10 MIL. V.B. TO BE APPLIED IN POOL AREA TO ALL WALLS (DIRECTLY TO STUD) AND CEILING (DIRECTLY TO BOTTOM OF THE TRUSS). VERIFY ALL SHEAR WALL LOCATIONS AND REQUIREMENTS WITH STRUCTURAL SHEAR WALL PLAN- IF DISCREPANCIES, DEFER TO STRUCTURAL DRAWINGS. PROVIDE ACCOUSTICAL SEALANT (TYP.) EACH SIDE, AT TOP & BOTTOM PLATES. NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED 2. GYP. BD. TO STRUCTURE ABOVE 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY W2 2X4 or 2x6 (SEE PLAN) WOOD STUD WITHOUT INSULATION WOOD 1HR WALL (UL DESIGN U305) NOTE: 1. GYP. BD. TO CEILING ABOVE 2. INSULATION TO BE MECHANICALLY FASTENED TO WALL ASSEMBLY TO MAINTAIN CONSISTENT THICKNESS C2 W3 2X4 or 2x6 (SEE PLAN) WOOD STUD WITH INSULATION 2X WOOD STUDS (SEE STRUCTURAL FOR SPACING) (2) LAYERS 5/8" TYPE "X" GYPSUM BD EACH SIDE WOOD STUD OUTER CAVITY WALL 2X6 WOOD STUD (SHEAR WALL) WITH SHEARWALL SHEATHING ON ONE OR BOTH SIDES; SEE STRUCT. FOR SHEATHING SPEC. WOOD 1HR WALL (UL DESIGN U333) 5/8" TYPE "X" GYPSUM BD. NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED 2. GYP. BD. TO STRUCTURE ABOVE 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. PROVIDE 6 MIL. V.B. ON INTERIOR SIDE 5. MIN. EIFS THICKNESS TO BE 2" FOR CONTINUOUS INSULATION "R" VALUE OF 7.5 6. OMIT GYP. BD. ON INTERIOR SIDE AT WALL CAVITIES WHERE THE INTERIOR SIDE OF OPPOSING WALLS WILL RECEIVE GYP. BD. (SUCH AS WITH W3) AND AT THE PORTE COCHERE COLUMNS. 7. WHERE EXTERIOR SHEAR WALLS OCCUR, FASTEN RATED SHEATHING PER SHEAR WALL SCHEDULE ON S201 PER STRUCTURAL. E1 WOOD 1 HR WALL - CORRIDOR (UL - U311 CALCULATED STC 55) SOUND BATT INSULATION TO FILL CAVITY W4 6 MIL VAPOR BARRIER 2X6 WOOD STUD WITH INSULATION, 7/16" RATED SHEATHING ON ONE SIDE AND RESILIENT CHANNEL 5/8" TYPE "C" GYPSUM BD EACH SIDE NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED 2. GYP. BD. TO STRUCTURE ABOVE 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY R-19 BATT INSULATION NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO DECKING ABOVE 2. GYP. BD. TO STRUCTURE ABOVE 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE SEE 2/A510 FOR DETAIL @ TUBS 5. ALL CORRIDOR WALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR SOUND TRANSMISSION- PROVIDE ACOUSTIC SEALANT 6. CORRIDOR WALL WITH SHEAR REQUIREMENTS SHALL HANG PLYWOOD ADDED TO ROOM SIDE IF REQUIRED BY STRUCT. 6. AT DOOR OPENINGS, OMIT RESILIENT CHANNEL AND FURR OUT WALL WITH 1/2" SHEATHING FOR DOOR FRAME BACKING. 2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING) SHEAR WALL SHEATHING ATTACHED DIRECTLY TO STUDS -VERIFY WITH STRUCT. 1/2" APA RATED OSB EXTERIOR SHEATHING CORRIDOR SIDE OF WALL SOUND BATT INSULATION TO FILL CAVITY SOUND BATT INSULATION TO FILL CAVITY NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED 2. GYP. BD. TO STRUCTURE ABOVE 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY 2X6 WOOD STUD WITH INSULATION, RESILIENT CHANNEL AND ADD. LAYER OF 5/8" TYPE "C" GYP. ADHERED STONE, EIFS OR SIDING NOTE: 1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED 2. GYP. BD. TO STRUCTURE ABOVE 3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 4. ALL BATHROOM EXHAUST SHAFTS & LAUNDRY CHUTE SHAFTS TO HAVE DENSE SHIELD ON THE INTERIOR OF THE SHAFT ONLY. IN LIEU OF 1 LAYER GYP. BD. ( DENSE SHIELD APPLIED ON TOP OF 1ST LAYER OF GYP. BD. ) 5. 2 HR. WALL FOR FIRST FLOOR A3 AREAS ONLY. WHERE WALL IS CONTINUOUS TO UPPER FLOORS, OUTER LAYER OF GYP. STOPS AT UNDERSIDE OF FLOOR DECKING. 6. WHERE WALL IS ENCLOSING A COLUMN, OMIT GYP. ON INTERIOR SIDE OF WALL. W5 2X WOOD STUD WITH INSULATION WOOD 2HR WALL (UL DESIGN U301) 2X6 EXTERIOR WALL ASSEMBLY WITH INSULATION EXTERIOR WOOD 1 HR WALL (UL - U356) 5/8" TYPE "X" GYP. BD. NAILED TO STUD W/ 1-7/8" 6D CEM. COAT. NAILS AT 7 IN. O.C. SHEAR WALL SHEATHING ATTACHED DIRECTLY TO STUDS ON ONE OR BOTH SIDES - SEE STRUCTURAL FOR LOCATIONS & FASTENING. 2x WOOD STUDS (SEE STRUCT. FOR SPACING) SOUND BATT INSULATION TO FILL CAVITY 2 LAYERS 5/8" TYPE "X" GYPSUM BD **SEE NOTE 3 2x WOOD STUDS (SEE STRUCTURAL FOR SPACING) NOTE: 1. SECURELY FASTEN TOP AND BOTTOM OF WALL(S) TO FLOOR AND DECKING ABOVE, AND PROVIDE FIRE CAULKING [3M FIRE BARRIER FD150 OR EQUAL] AT JOINTS, PENETRATIONS AND AS REQ'D. 2. GYP. BD. CONTINUOUS TO STRUCTURE ABOVE 3. GYP. BD. BETWEEN STUDS SHALL BE INSTALLED DURING THE ERECTION PHASE OF CONSTRUCTION TO ENSURE PROPER INSTALLATION AND FIRE RATING - G.C. TO COORDINATE. FASTEN BASE LAYER VERTICALLY WITH 1-7/8" LONG 6d COATED NAILS AT 14 IN. O.C. AND FACE LAYER HORIZONTALLY WITH 2-3/8 IN. 8d COATED ANILS AT 7 IN. O.C.- FACE LAYER BUTT JOINTS OFFSET ONE STUD LENGTH FROM BASE LAYER. 4. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS 5. SPACE WALL PLATES 1.5" APART 6. WALL TYPES B & C TO RETAIN ALL PARTS OF ASSEMBLY ABOVE W6 2X WOOD STUD WITH INSULATION WOOD 2HR WALL (UL DESIGN U301) 701 - 293 - 1350 701 - 224 - 5006 701 - 577 - 0033 engineers C LJA-1.COM SHEARWALL SHEATHING ATTACHED DIRECTLY TO STUDS 1/2" RESILIENT FURRING @ 24" O.C.(CORRIDOR SIDE) FARGO, ND BISMARCK, ND WILLISTON, ND 1/2" BLUERIDGE SOUNDSTOP FIBERBOARD (MEETING ASTM E94-91a) SHEARWALL SHEATHING ATTACHED DIRECTLY TO STUDS 5/8" TYPE "C" GYP. FOR SHEARWALL SHEATH. (SEE STRUCT.) 1/2" RESILIENT FURRING @ 24" O.C.(CORRIDOR SIDE) 2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING) i n co r po r a t ed 1/2" BLUERIDGE SOUNDSTOP FIBERBOARD (MEETING ASTM E94-91a) 5/8" TYPE "C" GYPSUM BD EACH SIDE C 5/8" TYPE "C" GYPSUM BOARD 5/8" TYPE "C" GYPSUM BOARD 2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING) 5/8" TYPE "C" GYPSUM BD EACH SIDE NOT PART OF RATED ASSEMBLY 5/8" TYPE "C" GYPSUM BOARD 2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING) 1 1/2" 2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING) 2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING) 2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING) a rchitects Lightowle r Jo h nson Associate s WALL TYPE DETAILS
© Copyright 2026 Paperzz