wall type details

1/2" BLUERIDGE SOUNDSTOP FIBERBOARD (MEETING ASTM E94-91a)
SOUND BATT INSULATION TO FILL CAVITY
SOUND BATT INSULATION TO FILL CAVITY
SOUND BATT INSULATION TO FILL CAVITY
SOUND BATT INSULATION TO FILL CAVITY
GUESTROOM SIDE OF WALL
SOUND BATT INSULATION TO FILL CAVITY
GUESTROOM SIDE OF WALL
CORRIDOR SIDE OF WALL
1/2" BLUERIDGE SOUNDSTOP FIBERBOARD (MEETING ASTM E84-91a)
5/8" TYPE "X" GYPSUM BOARD
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO
DECKING OF FLOOR ABOVE
2. GYP. BD. TO STRUCTURE ABOVE- ACOUSTIC SEALANT AT PLATES
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. ALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR SOUND
TRANSMISSION
5. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE
SEE 2/A510 FOR DETAIL @ TUBS
P1
2X6 WOOD STUD
WITH INSULATION & SOUNDBOARD ON BOTH SIDES
WOOD 1 HR WALL - PARTY WALL (UL-U387 CALCULATED STC 55 MIN.)
SHEAR WALL SHEATHING ATTACHED DIRECTLY TO STUDS
SHEAR WALL SHEATHING ATTACHED DIRECTLY TO STUDS
5/8" TYPE "X" GYPSUM BOARD
5/8" TYPE "X" GYPSUM BOARD
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO
DECKING OF FLOOR ABOVE.
2. GYP. BD. TO STRUCTURE ABOVE- ACOUSTIC SEALANT AT PLATES
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. ALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR SOUND
TRANSMISSION
5. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE
SEE 2/A510 FOR DETAIL @ TUBS
P2
P3
2X6 WOOD STUD WITH INSULATION, 7/16" RATED
SHEATHING ON ONE SIDE AND SOUNDBOARD
WOOD 1 HR WALL - PARTY WALL (UL-U387 CALCULATED STC 55 MIN.)
2X WOOD STUDS (SEE STRUCTURAL FOR SPACING)
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO
DECKING OF FLOOR ABOVE.
2. GYP. BD. TO STRUCTURE ABOVE- ACOUSTIC SEALANT AT PLATES
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. ALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR SOUND
TRANSMISSION
5. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE
SEE 2/A510 FOR DETAIL @ TUBS
WOOD 1 HR WALL - PARTY WALL (UL-U387 CALCULATED STC 55 MIN.)
2X WOOD STUDS (SEE STRUCTURAL FOR SPACING)
5/8" TYPE "C" GYPSUM BD EACH SIDE
2X6 WOOD STUD WITH INSULATION, 7/16"
RATED SHEATHING ON BOTH SIDES AND
SOUNDBOARD
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO DECKING ABOVE
2. GYP. BD. TO STRUCTURE ABOVE
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE
SEE 2/A510 FOR DETAIL @ TUBS
5. ALL CORRIDOR WALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR
SOUND TRANSMISSION- PROVIDE ACOUSTIC SEALANT
6. CORRIDOR WALL WITH SHEAR REQUIREMENTS SHALL HANG PLYWOOD ADDED TO
ROOM SIDE IF REQUIRED BY STRUCT.
6. AT DOOR OPENINGS, OMIT RESILIENT CHANNEL AND FURR OUT WALL WITH 1/2"
SHEATHING FOR DOOR FRAME BACKING.
C1
WOOD 1 HR WALL - CORRIDOR (UL - U311 CALCULATED STC 55)
2X WOOD STUDS
5/8" TYPE "X" GYPSUM BD EACH SIDE
5/8" TYPE "X" GYPSUM BD. ON FINISH SIDE
W1
2X4 or 2x6 (SEE PLAN)
WOOD STUD
WITH INSULATION
WOOD 1HR WALL (UL DESIGN U333)
GENERAL WALL TYPE NOTES:
1.
2.
3.
4.
5.
6.
7.
TOP AND BOTTOM OF WALLS TO BE EFFECTIVELY
FIRE-STOPPED; WHERE RATED WALLS OCCUR, GYP. BD. TO BE
CONTINUOUS FROM FLOOR TO BOTTOM OF RATED ASSEMBLY
OR DECK ABOVE.
EXTERIOR WALLS: 7/16" SHEATHING SHALL ALIGN WITH EDGE OF
FOUNDATION WALL.
STAGGER SHEATHING JOINTS. USE MOISTURE RESISTANT
CEMENTITIOUS MATERIALS @ CERAMIC TILE & WET AREASDENSARMOR PLUS FIREGUARD BOARD(TO MAINTAIN HOURLY
RATING OF WALL) OR EQUAL.
PROVIDE MIN. 4 MIL. V.B. ON INTERIOR (WARM) SIDE OF ALL
EXTERIOR WALLS.
MIN. 10 MIL. V.B. TO BE APPLIED IN POOL AREA TO ALL WALLS
(DIRECTLY TO STUD) AND CEILING (DIRECTLY TO BOTTOM OF
THE TRUSS).
VERIFY ALL SHEAR WALL LOCATIONS AND REQUIREMENTS WITH
STRUCTURAL SHEAR WALL PLAN- IF DISCREPANCIES, DEFER
TO STRUCTURAL DRAWINGS.
PROVIDE ACCOUSTICAL SEALANT (TYP.) EACH SIDE, AT TOP &
BOTTOM PLATES.
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED
2. GYP. BD. TO STRUCTURE ABOVE
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY
W2
2X4 or 2x6 (SEE PLAN)
WOOD STUD
WITHOUT INSULATION
WOOD 1HR WALL (UL DESIGN U305)
NOTE:
1. GYP. BD. TO CEILING ABOVE
2. INSULATION TO BE MECHANICALLY FASTENED TO WALL ASSEMBLY TO
MAINTAIN CONSISTENT THICKNESS
C2
W3
2X4 or 2x6 (SEE PLAN) WOOD STUD
WITH INSULATION
2X WOOD STUDS (SEE STRUCTURAL FOR SPACING)
(2) LAYERS 5/8" TYPE "X" GYPSUM BD EACH SIDE
WOOD STUD OUTER CAVITY WALL
2X6 WOOD STUD (SHEAR WALL)
WITH SHEARWALL SHEATHING
ON ONE OR BOTH SIDES; SEE
STRUCT. FOR SHEATHING SPEC.
WOOD 1HR WALL (UL DESIGN U333)
5/8" TYPE "X" GYPSUM BD.
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED
2. GYP. BD. TO STRUCTURE ABOVE
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. PROVIDE 6 MIL. V.B. ON INTERIOR SIDE
5. MIN. EIFS THICKNESS TO BE 2" FOR CONTINUOUS INSULATION "R" VALUE OF 7.5
6. OMIT GYP. BD. ON INTERIOR SIDE AT WALL CAVITIES WHERE THE INTERIOR SIDE
OF OPPOSING WALLS WILL RECEIVE GYP. BD. (SUCH AS WITH W3) AND AT THE
PORTE COCHERE COLUMNS.
7. WHERE EXTERIOR SHEAR WALLS OCCUR, FASTEN RATED SHEATHING PER SHEAR
WALL SCHEDULE ON S201 PER STRUCTURAL.
E1
WOOD 1 HR WALL - CORRIDOR (UL - U311 CALCULATED STC 55)
SOUND BATT INSULATION TO FILL CAVITY
W4
6 MIL VAPOR BARRIER
2X6 WOOD STUD WITH INSULATION, 7/16"
RATED SHEATHING ON ONE SIDE AND
RESILIENT CHANNEL
5/8" TYPE "C" GYPSUM BD EACH SIDE
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED
2. GYP. BD. TO STRUCTURE ABOVE
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY
R-19 BATT INSULATION
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED; WALL CONT. TO DECKING ABOVE
2. GYP. BD. TO STRUCTURE ABOVE
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY, PLEASE
SEE 2/A510 FOR DETAIL @ TUBS
5. ALL CORRIDOR WALL PLATES NEED TO BE EXTENDED TO DECK ABOVE FOR
SOUND TRANSMISSION- PROVIDE ACOUSTIC SEALANT
6. CORRIDOR WALL WITH SHEAR REQUIREMENTS SHALL HANG PLYWOOD ADDED TO
ROOM SIDE IF REQUIRED BY STRUCT.
6. AT DOOR OPENINGS, OMIT RESILIENT CHANNEL AND FURR OUT WALL WITH 1/2"
SHEATHING FOR DOOR FRAME BACKING.
2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING)
SHEAR WALL SHEATHING ATTACHED DIRECTLY TO STUDS
-VERIFY WITH STRUCT.
1/2" APA RATED OSB EXTERIOR SHEATHING
CORRIDOR SIDE OF WALL
SOUND BATT INSULATION TO FILL CAVITY
SOUND BATT INSULATION TO FILL CAVITY
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED
2. GYP. BD. TO STRUCTURE ABOVE
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. WET APPLY DENSESHIELD IN LIEU OF GYP BD @ WET WALL ONLY
2X6 WOOD STUD WITH INSULATION,
RESILIENT CHANNEL AND ADD. LAYER
OF 5/8" TYPE "C" GYP.
ADHERED STONE, EIFS OR SIDING
NOTE:
1. TOP AND BOTTOM OF WALL EFFECTIVELY FIRESTOPPED
2. GYP. BD. TO STRUCTURE ABOVE
3. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
4. ALL BATHROOM EXHAUST SHAFTS & LAUNDRY CHUTE SHAFTS TO HAVE DENSE
SHIELD ON THE INTERIOR OF THE SHAFT ONLY. IN LIEU OF 1 LAYER GYP. BD. (
DENSE SHIELD APPLIED ON TOP OF 1ST LAYER OF GYP. BD. )
5. 2 HR. WALL FOR FIRST FLOOR A3 AREAS ONLY. WHERE WALL IS CONTINUOUS TO
UPPER FLOORS, OUTER LAYER OF GYP. STOPS AT UNDERSIDE OF FLOOR DECKING.
6. WHERE WALL IS ENCLOSING A COLUMN, OMIT GYP. ON INTERIOR SIDE OF WALL.
W5
2X WOOD STUD
WITH INSULATION
WOOD 2HR WALL (UL DESIGN U301)
2X6 EXTERIOR WALL
ASSEMBLY WITH INSULATION
EXTERIOR WOOD 1 HR WALL (UL - U356)
5/8" TYPE "X" GYP. BD. NAILED TO STUD W/ 1-7/8" 6D CEM. COAT. NAILS AT 7 IN. O.C.
SHEAR WALL SHEATHING ATTACHED DIRECTLY TO STUDS ON ONE OR BOTH SIDES
- SEE STRUCTURAL FOR LOCATIONS & FASTENING.
2x WOOD STUDS (SEE STRUCT.
FOR SPACING)
SOUND BATT INSULATION TO FILL CAVITY
2 LAYERS 5/8" TYPE "X" GYPSUM BD **SEE NOTE 3
2x WOOD STUDS (SEE STRUCTURAL FOR SPACING)
NOTE:
1. SECURELY FASTEN TOP AND BOTTOM OF WALL(S) TO FLOOR AND DECKING ABOVE, AND
PROVIDE FIRE CAULKING [3M FIRE BARRIER FD150 OR EQUAL] AT JOINTS, PENETRATIONS
AND AS REQ'D.
2. GYP. BD. CONTINUOUS TO STRUCTURE ABOVE
3. GYP. BD. BETWEEN STUDS SHALL BE INSTALLED DURING THE ERECTION PHASE OF
CONSTRUCTION TO ENSURE PROPER INSTALLATION AND FIRE RATING - G.C. TO
COORDINATE. FASTEN BASE LAYER VERTICALLY WITH 1-7/8" LONG 6d COATED NAILS AT 14
IN. O.C. AND FACE LAYER HORIZONTALLY WITH 2-3/8 IN. 8d COATED ANILS AT 7 IN. O.C.- FACE
LAYER BUTT JOINTS OFFSET ONE STUD LENGTH FROM BASE LAYER.
4. STAGGER JOINTS, WATER RESISTANT @ CERAMIC TILE & WET AREAS
5. SPACE WALL PLATES 1.5" APART
6. WALL TYPES B & C TO RETAIN ALL PARTS OF ASSEMBLY ABOVE
W6
2X WOOD STUD
WITH INSULATION
WOOD 2HR WALL (UL DESIGN U301)
701 - 293 - 1350
701 - 224 - 5006
701 - 577 - 0033
engineers
C
LJA-1.COM
SHEARWALL SHEATHING ATTACHED DIRECTLY TO STUDS
1/2" RESILIENT FURRING @ 24" O.C.(CORRIDOR SIDE)
FARGO, ND
BISMARCK, ND
WILLISTON, ND
1/2" BLUERIDGE SOUNDSTOP FIBERBOARD (MEETING ASTM E94-91a)
SHEARWALL SHEATHING ATTACHED DIRECTLY TO STUDS
5/8" TYPE "C" GYP. FOR SHEARWALL SHEATH. (SEE STRUCT.)
1/2" RESILIENT FURRING @ 24" O.C.(CORRIDOR SIDE)
2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING)
i n co r po r a t ed
1/2" BLUERIDGE SOUNDSTOP FIBERBOARD (MEETING ASTM E94-91a)
5/8" TYPE "C" GYPSUM BD EACH SIDE
C
5/8" TYPE "C" GYPSUM BOARD
5/8" TYPE "C" GYPSUM BOARD
2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING)
5/8" TYPE "C" GYPSUM BD EACH SIDE
NOT PART OF
RATED ASSEMBLY
5/8" TYPE "C" GYPSUM BOARD
2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING)
1 1/2"
2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING)
2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING)
2X6 WOOD STUDS (SEE STRUCTURAL FOR SPACING)
a rchitects
Lightowle r Jo h nson
Associate s
WALL TYPE DETAILS