RFOU-HCF-30kV-HF_2014 12.11.2014 09:12:00 Page 1 of 3 RFOU-HCF 18/30(36)kV P33 / 1100°C / 30-60 min. HydroCarbon Fire resistant, flame retardant halogen-free medium voltage power cable. RFOU-HCF 18/30(36)kV EPR/EPR/TCWB/EVA/HCF/SHF1 NEK 606 Code P33 1100°C / 2000°F / 200 kW/m² Operating temperature Operating Voltage : 90°C : 18/30(36)kV Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital. IEC 60092-354 Draka Norsk Kabel IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-21 EN 1363-2 / ISO 834 IEC 600754-1,2 IEC 61034-1,2 - Design - HCF protection - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - HC Fire resistance - Halogen Free - Low Smoke Construction Code Letter Conductor Conductor screen semiconductive Insulation Insulation screen semicoductive Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Semiconductive layer (EP-rubber) R Lay up / Shielding Inner covering Tape over bedding Armour/screen Tape over armour/screen Outer sheath HCF protection Tape F EP-rubber, IEC 60092-360 (EPR) Semiconductive layer (EP-rubber) Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Flame retardant and halogen-free thermoset compound PET tape O Tinned copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Extruded heatblock compound Lapped glassfibre tape Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092360) Eg. "meter" "year" DRAKA NORSK KABEL RFOU-HCF 18/30(36)kV P33 1x 95/30 mm2 HCF 1100/60 FLEX - FLAME -HCF Overall sheath Marking text Subject to change without prior notice Draka Norsk Kabel AS www.draka.no / www.prysmiangroup.com RFOU-HCF-30kV-HF_2014 12.11.2014 09:12:00 Page 2 of 3 RFOU-HCF 18/30(36)kV P33 / 1100°C / 30-60 min. Code Letter Outer sheath colour Red Range and dimensions New Part number Type Diameter Thickness of Diameter Diameter over bedding armour sheath overall HCF[mm] wires protection [mmØ] [mm] (mm) [mm2] Type (mm²) 1 x 95/30 35,0 ± 2,0 0,4 1 x 240/35 42,0 ± 2,5 0,4 42,0 ± 3,0 50,0 ± 3,0 Weight of cable approx. [kg/km] 75,5 ± 3,5 7980 84,0 ± 4,0 10780 Diameter of copper conductor approx. mmØ Insulation thickness, nominal mm Semiconducting layer thickness approx. mm Diameter over insulated, screened conductor, approx. mm 12.1 19.1 8.0 8.0 0.8 0.8 31.3 38.3 1x 95/30 1x 240/35 ELECTRICAL DATA No. of cores x cross section [mm2] 1x 95/30 1x 240/35 Conductor resistance DC [/km] Reactance [/km] Impedance [/km] at 90 °C Continous current rating Short circuit (conductor) [Ampere] at 20 °C at 90 °C at 50 Hz at 50 Hz at 45 °C 1 sec 0,3 sec 0.195 0.0762 0.249 0.0972 0.138 0.120 0.285 0.154 293 290 13300 33600 24282 61345 Subject to change without prior notice Draka Norsk Kabel AS www.draka.no / www.prysmiangroup.com RFOU-HCF-30kV-HF_2014 12.11.2014 09:12:00 Page 3 of 3 RFOU-HCF 18/30(36)kV P33 / 1100°C / 30-60 min. INSTALLATION DATA TYPE [mm2] Overall Diameter [mmØ] 1x 95/30 1x 240/35 75.5 ± 3.5 84.0 ± 4.0 Minimum bending radius During Fixed Installation Installed [mm] 20 x D 12 x D 1510 1680 906 1008 Maximum pulling tension [N] 4750 12000 Minimum installation temperature: - 10°C The RFOU-HCF MV cables are available on request in all voltage levels from 3,6/6(7,2)kV up to and including 26/45(52)kV. Please be aware that we have a limitation on the cable diameter which allows us to manufacture mainly single core cables on these voltage levels. Subject to change without prior notice Draka Norsk Kabel AS www.draka.no / www.prysmiangroup.com
© Copyright 2026 Paperzz