Rittal PMC Technical Specifications 7857.010 7857.015 7857.030 7857.110 7857.020 7857.040 7857.120 10 – 15 – 20 – 30 – 40 kVA Uninterruptible Power Supply (UPS) Modular, n+1 redundant, three-phase On-line, Double-Conversion, VFI A3346402IT74-GB A3346402IT74-GB 2 CONTENTS TECHNICAL SPECIFICATIONS POWER MODULAR CONCEPT PMC ..................................................3 1. GENERAL DATA ................................................................................................................................3 2. RECTIFIER DATA ..............................................................................................................................4 3. BATTERY DATA .................................................................................................................................4 4. INVERTER DATA ...............................................................................................................................4 5. POWER MANAGEMENT DISPLAY (PMD) ........................................................................................5 6. OPTIONALS........................................................................................................................................5 7. TECHNICAL SPECIFICATIONS POWER MODULAR CONCEPT BASIC ........................................6 7.1 MECHANICAL CHARACTERISTICS PMC BASIC....................................................................6 7.2 BLOCK DIAGRAM PMC BASIC .................................................................................................8 7.3 CABLE SECTIONS AND FUSE RATINGS RECOMMENDED BY EUROPEAN STANDARDS ALTERNATIVELY, LOCAL STANDARDS TO BE RESPECTED......................................................8 8. TECHNICAL SPECIFICATIONS POWER MODULAR CONCEPT TWIN..........................................9 8.1 MECHANICAL CHARACTERISTICS PMC TWIN (NOT AVAILABLE FOR 40KVA MODULE) ..........9 8.2 BLOCK DIAGRAM PMC TWIN ................................................................................................10 8.3 CABLE SECTIONS AND FUSE RATINGS RECOMMENDED BY EUROPEAN STANDARDS ALTERNATIVELY, LOCAL STANDARDS TO BE RESPECTED....................................................10 9. TECHNICAL SPECIFIKATIONS POWER MODULAR EXTENDED TWIN......................................11 9.1 MECHANICAL CHARACTERISTICS PMC EXTENDED TWIN .................................................11 9.2 BLOCK DIAGRAM EXTENDED TWIN......................................................................................13 9.3 CABLE SECTIONS AND FUSE RATINGS RECOMMENDED BY EUROPEAN STANDARDS ALTERNATIVELY, LOCAL STANDARDS TO BE RESPECTED....................................................13 3 A3346402IT74-GB TECHNICAL SPECIFICATIONS POWER MODULAR CONCEPT PMC 10, 15, 20, 30 and 40 kVA (three phase input and output) 1. GENERAL DATA Output Rated Power kVA 10 15 20 30 40 0.8 Output Power Factor On-Line, Double Conversion, VFI Topology Second Generation, Tansformerless Technology Modular, Parallelable Construction For redundancy and/or capacity: - Standard up to 10 modules - Without limitation on request Parallel Configuration Double Conversion AC-AC efficiency with batt. fully charged 100%/75%/50%25% Linear Load (cos=0.8ind) % 94.5/94.5/93/91 94.5/94.5/93/91 94.5/94.5/93/91 95/95/93.5/92 95/95/93.5/92 100%/75%/50%/25% Linear Load (Resistive cos=1) % 94/94/92/90 94/94/92/90 94/94/92/90 94/94/92.5/91 94/94/92.5/91 100%/75%/50%/25% Non-linear Load (EN50091-1) % 93/93/91/90 93/93/91/90 93/93/91/90 93/93/92/91 93/93/92/91 % 98 98 98 98 98 1600 Eco-Mode efficiency (load on by-pass) at 100% load Heat Dissipation With 100% Load (cos= 0.8ind) W 400 600 800 1200 Heat Dissipation With 100% Load (Resistive cos= 1) W 480 720 960 1450 1920 Heat Dissipation With 100% Non-linear Load (EN50091-1) W 560 840 1120 1680 2240 Airflow (25° - 30°C) with Non-linear Load (EN50091-1) 3 m /h 110 150 200 300 400 Audible Noise with 100% / 50% Load dBA 55/49 57/49 57/49 59/51 63/53 Ambient Temperature for UPS °C 0 – 40 Ambient Temperature for Batteries (recommended) °C 20 - 25 Storage Temperature °C -25 - +70 Max. 6 months Battery Storage Time at Ambient Temperature Fan-assisted Cooling Max. 95% (non-condensing) Relative Air-humidity Standards Safety Electromagnetic Compatibility Performance EN 50091 - Part 1 (IEC 62040-1, IEC 60950) EN 50091 - Part 2 (IEC 62040 –2) EN 50091 - Part 3 (IEC 62040 –3) Provided with UPS Transportation Palette Accessibility Totally front accessibility for service and maintenance (no need for side, top or rear access) Positioning Min. 10cm rear space (required for fan) From front and bottom Input and Output Power Cabling For remote signalling and automatic computer shutdown Dry Port (Volt-free contacts) For monitoring and integration in network management Smart Port (RS 232) EMERGENCY OFF (Normally closed) GEN-ON (Normally open) BATTERY TEMP. SENSOR Input Terminals UPS Module Weight UPS Module Size (WxHxD) kg 10 – 20kVA = 40kg, 30kVA = 55kg ; 40kVA = 58kg mm 483 x 400 x 675 4 A3346402IT74-GB 2. RECTIFIER DATA Input Voltage Input Voltage Tolerance (ref to 3x400/230V) Input Frequency V 3x380/220V+N, 3x400V/230V+N, 3x415/240V+N For Loads: <100%(-23%,+15%) V (%) <80%(-30%,+15%) Hz <60%(-40%,+15%) 35 – 70 Input Power Factor 0.98 Input Current Form Sinewave THDI = 7÷9% at 100% load Limited by soft start Inrush Current Model kVA 10 15 20 30 40 Input Power with rated output power and charged battery kW 8.6 12.9 17.2 25.8 34 Max. Input Power with rated output power and discharged battery kW 9.6 13.8 19.2 28.2 38 3. BATTERY DATA Maximum Battery Charger Current (standard) 10 A Battery Charging Curve IU (DIN 41773) Temperature Controlled Battery Charger Yes Battery Charger Ripple Ripple-free battery charging Battery Test Automatic and periodic (adjustable) Battery Type Variable Number of 12V Battery Blocks Lead-acid, Maintenance-free and NiCd 30-50 blocks for 10-20kVA, 40-50 blocks for 30kVA and 50 blocks for 40kVA 4. INVERTER DATA Output Rated Power KVA Output Rated Voltage V 10 15 20 30 3x380/220V, 3x400/230V, 3x415/240V 0.8 Output Power Factor Output Voltage Stability - Static % < +/- 1 - Dynamic (with load Step 0-100%, 100-0%) % < +/- 4 Output Voltage Distortion - With Linear Load % +/-2 - With Non-linear Load (EN 50091) % < +/- 3 (according to EN 50091-1) Recovery Time After Load Jump (0-100%, 100-0%) msec 20 % 100% (all 3 phases regulated independently) Permissible Unbalanced Load sinewave Output waveform Hz 50 or 60 - Free-running, Quartz Oscillator % + / - 0.1 - Synchronized with mains (adjustable) % +/-4 % 125 for 10min. and 150 for 1min. Output Frequency Output Frequency Tolerance Overload Capability Crest - Factor 3:1 40 5 A3346402IT74-GB 5. POWER MANAGEMENT DISPLAY (PMD) The user-friendly PMD consists of three parts the MIMIC DIAGRAM, CONTROL KEYS and LCD that provides the necessary monitoring information about the UPS. MIMIC DIAGRAM The mimic diagram serves to give the general status of the UPS. The LED-indicators show the power flow status and in the event of mains failure or load transfer from inverter to bypass and vice-versa the corresponding LED-indicators will change colour from green (normal) to red (warning). The LED’s LINE 1 (rectifier) and LINE 2 (bypass) indicate the availability of the mains power supply. The LED’s INVERTER and BYPASS if green indicate which of the two are supplying power to the critical load. When the LED-indicator BATTERY is lit it means that the battery due to mains failure is supplying the load. The LED-indicator ALARM is a visual indication of any internal or external alarm condition. At the same time the audible alarm will be activated. PUSHBUTTONS The pushbuttons serve to manage the UPS by performing commands. The 2xON/OFF pushbuttons serve to start-up or shutdown the UPS if pressed simultaneously. The pushbuttons UP and DOWN allow working through the PMD-menu. The RESET pushbutton serves to cancel the audible alarm in the event of a disturbance. If the alarm condition was only transient the LED-indicator ALARM would also extinguish otherwise it will remain on (red). DISPLAY The 2 x 20 character LCD simplifies the communication with the UPS. The menu driven LCD enables the access to the EVENT REGISTER, or to monitor the input and output U, I, f, P, Autonomy Time and other Measurement’s, to perform commands like start-up and shut-down of INVERTER or load transfer from INVERTER to BYPASS and vice-versa and finally it serves for the DIAGNOSIS (SERVICE MODE) for adjustments and testing (for more details see the USER MANUAL of Power Modular Concept). Power Modular Concept ON/OFF LINE 2 BY PASS BATTERY LINE 1 ON/OFF ALARM INV RESET ENTER Power Management Display (PMD) of Power Modular Concept. 6. OPTIONALS Extended Battery Autonomies Optional Battery Charger In matching battery frames TS 8 For longer autonomies Remote Signalling Panel (RSP) For UPS-Status indication Parallel Configuration (standard) A number of units may be paralleled for redundancy or capacity PMC Extended Twin PMC-Software SNMP - Adapter Input or Output Isolation Transformer For automatic shut-down and monitoring For network management and remote monitoring For special voltages or for galvanic isolation 6 A3346402IT74-GB 7. TECHNICAL SPECIFICATIONS POWER MODULAR CONCEPT BASIC 7.1 MECHANICAL CHARACTERISTICS PMC BASIC kVA MODEL 10 15 mm Dimensions (WxHxD) 20 30 40 600 x 2000 x 1000 Protection Degree 600 x 2000 x 1000 IP 20 Ventilation Fan assisted Colour RAL 7035 m Foot Print 2 0.41 Maximum Output Power of one PMC Basic 40 kVA Dimensions of PMC Basic (Depth 1000mm) PMC Basic Frame: TS 8 Power (kVA) 2000mm 600mm TS 8 Maximum Autonomy (min.) Maximum Battery Frame Type UPS +Battery Weight (kg) 10 0 ____ TS 8 200 10 16 40 x 7Ah TS 8 300 10 16 (2x30) x 7Ah TS 8 350 10 24 (2x40) x 7Ah TS 8 400 10 40 (3x40) x 7Ah TS 8 500 15 0 ____ TS 8 205 15 10 (2x30) x 7Ah TS 8 355 15 14 (2x40) x 7Ah TS 8 405 15 24 (3x40) x 7Ah TS 8 505 20 0 ____ TS 8 205 20 10 (2x40) x 7Ah TS 8 405 20 16 (3x40) x 7Ah TS 8 505 30 0 ____ TS 8 210 30 10 (3x40) x 7Ah TS 8 510 Battery Frame TS 8 In the Battery Frame TS 8 to 90 x 24Ah / 28Ah may be fitted. The maximum achievable autonomy with one additional Battery Frame TS 8 are: Maximum Power Maximum Autonomy (kVA) Battery (min.) 2000mm 800mm 1000mm Frame Type UPS +Battery Weight (kg) 10 132 90x24Ah TS 8 1160 15 78 90x24Ah TS 8 1160 20 53 90x24Ah TS 8 1160 30 32 90x24Ah TS 8 1160 7 A3346402IT74-GB Dimensions of PMC Basic (Depth 1000mm) for 40kVA PMC Basic Frame: TS 8 Power (kVA) Autonomy (min.) Battery Type Frame Type Weight (kg) 40 0 ____ TS 8 280 40 8 (3x50) x 7Ah TS 8 660 40 12 (4x50) x 7Ah TS 8 790 2000mm 600mm TS 8 Battery Frame TS 8 In the Battery Frame TS 8 up to 100 x 24Ah / 28Ah may be fitted. The maximum achievable autonomy with one additional Battery Frame TS 8 are: 2000mm 800mm 1000mm Power (kVA) Maximum Autonomy (min.) Maximum Battery 40 25 40 42 Frame Type UPS+Battery Weight (kg) (2x50)x24Ah TS 8 1370 (3x50)x24Ah 2xTS 8 2010 8 A3346402IT74-GB 7.2 BLOCK DIAGRAM PMC BASIC 7.3 CABLE SECTIONS AND FUSE RATINGS RECOMMENDED BY EUROPEAN STANDARDS ALTERNATIVELY, LOCAL STANDARDS TO BE RESPECTED STANDARD VERSION (SINGLE FEED INPUT) Power (kVA) Fuse A (Agl/CB) Cable A (IEC 60950-1:2001) Cable D (IEC 60950-1:2001) Fuse E +/N/- Cable E +/N/- 5x2.5 5x4 5x6 5x10 5x25 3x32A 3x63A 3x63A 3x80A 3x100A 3x4 3x10 3x10 3x16 3x25 3x20 5x2.5 10 3x25 5x4 15 3x40 5x6 20 3x63 5x10 30 3x80 5x25 40 VERSION ON REQUEST (DUAL FEED INPUT) Power (kVA) Fuse B (Agl/CB) Cable B (IEC 60950-1:2001) Fuse C (Agl/CB) Cable C (IEC 60950-1:2001) Cable D (IEC 60950-1:2001) Fuse E +/N/- Cable E +/N/- 10 15 20 30 40 3x20 3x25 3x40 3x63 3x80 5x2.5 5x4 5x6 5x10 5x25 3x20 3x25 3x40 3x63 3x80 4x2.5 4x4 4x6 4x10 4x25 5x2.5 5x4 5x6 5x10 5x25 3x32A 3x63A 3x63A 3x80A 3x100A 3x4 3x10 3x10 3x16 3x25 9 A3346402IT74-GB 8. TECHNICAL SPECIFICATIONS POWER MODULAR CONCEPT TWIN 8.1 MECHANICAL CHARACTERISTICS PMC TWIN (NOT AVAILABLE FOR 40KVA MODULE) MODEL KVA 2x10 2x15 mm Dimensions (WxHxD) 2x20 2x30 600 x 2000 x 1000 Protection Degree IP 20 Ventilation Fan assisted Colour RAL 7035 m2 Foot Print 0.41 Maximum Output Power of one PMC Twin 60 kVA Dimensions of PMC Twin (depth 1000mm) TS 8 TS 8 2000 Power (kVA) Autonomy (min.) Battery Type Frame Type Weight (kg) 10 + 10 0 ____ TS 8 265 10 + 10 7+7 (2x30)x7Ah TS 8 415 10 + 10 10 + 10 (2x40)x7Ah TS 8 465 10 + 10 16 + 16 2x(2x30)x7Ah TS 8 575 15 + 15 0 ____ TS 8 280 15 + 15 5+5 (2x30)x7Ah TS 8 430 15 + 15 7+7 (2x40)x7Ah TS 8 480 15 + 15 10 + 10 2x(2x30)x7Ah TS 8 580 20 + 20 0 ____ TS 8 280 20 + 20 5+5 (2x40)x7Ah TS 8 480 20 + 20 7+7 2x(2x30)x7Ah TS 8 580 30 + 30 0 ____ TS 8 290 30 + 30 10 (3x40)x7Ah *) TS 8 590 *) This battery is common for the 2 modules of 30kVA, Two separate batteries (5+5)min. are available on request. 600mm 1000mm Power (kVA) Maximum Autonomy (min.) Maximum Battery Frame Type UPS + Battery Weight (kg) 10 + 10 90 + 90 120x24Ah TS 8 1535 15 + 15 55 + 55 120x24Ah TS 8 1550 20 + 20 38 + 38 120x24Ah TS 8 1550 30 + 30 46 120x24Ah*) TS 8 1560 *) This battery is common for the 2 modules of 30kVA, Two separate batteries (23+23)min. are available on request. 10 A3346402IT74-GB 8.2 BLOCK DIAGRAM PMC TWIN MAINS (3x380V/220V, 3x400/230V,3x415/240V Cable A F4 Fuse E Inverter Rectifier F5 Inverter Cable C Cable E Fuse E Rectifier F4 Inverter F1 F2 Main.Bypass IA1 Rectifier F5 Inverter Static Switch Static Switch IA2-1 IA2-2 IA2-2 IA2-1 Twin Frame Cable B MAINS (3x380V/220V, 3x400/230V,3x415/240 F1 F2 Static Switch Static Switch Fuse C F2 UPS module 2 Rectifier Cable E F1 F2 UPS module 1 F1 Fuse B UPS module 1 Fuse A VERSION ON REQUEST (DOUBLE INPUT FEED) UPS module 2 STANDARD VERSION (SINGLE INPUT FEED) Main.Bypass IA1 Twin Frame Cable D Cable D Load Load 8.3 CABLE SECTIONS AND FUSE RATINGS RECOMMENDED BY EUROPEAN STANDARDS ALTERNATIVELY, LOCAL STANDARDS TO BE RESPECTED STANDARD VERSION (SINGLE FEED INPUT) Cable A Power (kVA) Fuse A (Agl/CB) (IEC 60950-1:2001) 3x40 5x6 10 3x40 5x6 10+10 3x63 5x10 15 3x63 5x10 15+15 3x80 5x16 20 3x80 5x16 20+20 3x100 5x25 30 3x100 5x25 30+30 Cable D (IEC 60950-1:2001) 5x6 5x6 5x10 5x10 5x16 5x16 5x25 5x25 Fuse E Cable E +/N/- +/N/- 3x32A 3x63A 3x63A 3x100A* 3x63A 3x125A* 3x80A 3x125A* 3x4 3x10* 3x10 3x25* 3x10 3x35* 3x16 3x35* VERSION ON REQUEST (DUAL FEED INPUT) Cable B Cable C Cable D Power (kVA) Fuse B (Agl/CB) Fuse C (Agl/CB) (IEC 60950-1:2001) (IEC 60950-1:2001) (IEC 60950-1:2001) 3x40 5x6 3x40 4x6 5x6 10 3x40 5x6 3x40 4x6 5x6 10+10 3x63 5x10 3x63 4x10 5x10 15 3x63 5x10 3x63 4x10 5x10 15+15 3x80 5x16 3x80 4x16 5x16 20 3x80 5x16 3x80 4x16 5x16 20+20 3x100 5x25 3x100 4x25 5x25 30 3x100 5x25 3x100 4x25 5x25 30+30 *only valid for common battery use Fuse E Cable E +/N/- +/N/- 3x32A 3x63A* 3x63A 3x100A* 3x63A 3x125A* 3x80A 3x125A* 3x4 3x10* 3x10 3x25* 3x10 3x35* 3x16 3x35* 11 A3346402IT74-GB 9. TECHNICAL SPECIFIKATIONS POWER MODULAR EXTENDED TWIN 9.1 MECHANICAL CHARACTERISTICS PMC EXTENDED TWIN MODEL KVA 3x10 mm Dimensions (WxHxD) 3x15 3x20 3x30 3x40 600 x 2000 x 1000 Protection Degree IP 20 Ventilation Fan assisted Colour RAL 7035 m Foot Print 2 0.41 Maximum Output Power of one Extended Twin 90kVA or 120 kVA Dimensions of PMC Extended Twin(depth 1000mm) TS 8 TS 8 2000 600mm Power (kVA) Autonomy (min.) Battery Type Frame Type Weight (kg) 10 0 ____ TS 8 170 10 + 10 0 ____ TS 8 215 10 + 10 + 10 0 ____ TS 8 260 15 0 ____ TS 8 175 15 + 15 0 ____ TS 8 225 15 + 15 + 15 0 ____ TS 8 275 20 0 ____ TS 8 175 20 + 20 0 ____ TS 8 225 20 + 20 + 20 0 ____ TS 8 275 30 0 ____ TS 8 180 30 + 30 0 ____ TS 8 235 30 + 30 + 30 0 ____ TS 8 290 1000mm In the battery frame TS 8 up to 120 x 24Ah/28Ah batteries respectively may be fitted allowing the maximum autonomies as shown in the table on the left bellow: Power (kVA) Maximum Autonomy (min.) Maximum Battery 10+10+10 15+15+15 20+20+20 30+30+30 46+46+46 28+28+28 20+20+20 11+11+11 120x24Ah 120x24Ah 120x24Ah 120x24Ah Frame Type TS 8 TS 8 TS 8 TS 8 UPS + Battery Weight (kg) 1530 1545 1545 1560 12 A3346402IT74-GB Dimensions of PMC Extended Twin (depth 100mm) for 40kVA TS 8 TS 8 (for separate battery) TS 8 (for common battery) Power (kVA) Autonomy (min.) Battery Type Frame Type Weight (kg) 40 0 ____ TS 8 190 40 + 40 0 ____ TS 8 248 40 + 40 + 40 0 ____ TS 8 306 2000 800mm 1000mm Power (kVA) Maximum Autonomy (min.) Maximum Battery Frame Type UPS + Battery Weight (kg) 40+40+40 11+11+11 (3x50)x24Ah 2x TS 8 2032 In the battery frame TS 8 up to 120 x 24Ah/28Ah batteries respectively may be fitted allowing the maximum autonomies as shown in the above table. 13 A3346402IT74-GB 9.2 BLOCK DIAGRAM EXTENDED TWIN VERSION ON REQUEST (DUAL INPUT FEED) Cable A Inverter Static Switch Inverter Static Switch IA2-1 Rectifier Inverter Extended Twin Frame Cable E Cable C Rectifier Inverter IA2-1 Inverter Rectifier Inverter Static Switch IA2-2 Extended Twin Frame Maintenance Bypass IA1 Rectifier F1 F2 Static Switch Static Switch IA2-3 MAINS (3x380V/220V, 3x400/230V,3x415/240V F1 F2 Fuse E Static Switch IA2-2 Cable B UPS module 1 Fuse E Rectifier UPS module 3 Rectifier Fuse C F1 F2 F1 F2 UPS module 2 Cable E F1 F2 UPS module 1 F1 F2 Fuse B IA2-3 Maintenance Bypass IA1 Cable D Cable D Load Load 9.3 CABLE SECTIONS AND FUSE RATINGS RECOMMENDED BY EUROPEAN STANDARDS ALTERNATIVELY, LOCAL STANDARDS TO BE RESPECTED STANDARD VERSION (SINGLE FEED INPUT) Power (kVA) 10 10+10 10+10+10 15 15+15 15+15+15 20 20+20 20+20+20 30 30+30 30+30+30 40 40+40 40+40+40 Fuse A (Agl/CB) 3x63 3x63 3x63 3x100 3x100 3x100 3x100 3x100 3x100 3x125 3x125 3x125 3x200 3x200 3x200 Cable A (IEC 60950-1:2001) 5x10 5x10 5x10 5x25 5x25 5x25 5x25 5x25 5x25 5x35 5x35 5x35 5x70 5x70 5x70 * only valid for common battery use Cable D (IEC 60950-1:2001) 5x10 5x10 5x10 5x25 5x25 5x25 5x25 5x25 5x25 5x35 5x35 5x35 5x70 5x70 5x70 Fuse E Cable E +/N/- +/N/- 3x32A 3x63A* 3x100A* 3x63A 3x100A* 3x125A* 3x63A 3x125A* 3x160A* 3x80A 3x125A* 3x200A* 3x100A 3x160A* 3x250A* 3x4 3x10* 3x25* 3x10 3x25* 3x35* 3x10 3x35* 3x50* 3x16 3x35* 3x70* 3x25 3x50* 3x120* UPS module 3 MAINS (3x380V/220V, 3x400/230V,3x415/240V Fuse A UPS module 2 STANDARD VERSION (SINGLE INPUT FEED) 14 A3346402IT74-GB VERSION ON REQUEST (DUAL FEED INPUT) Power (kVA) 10 10+10 10+10+10 15 15+15 15+15+15 20 20+20 20+20+20 30 30+30 30+30+30 40 40+40 40+40+40 Fuse B (Agl/CB) 3x63 3x63 3x63 3x100 3x100 3x100 3x100 3x100 3x100 3x125 3x125 3x125 3x200 3x200 3x200 Cable B (IEC 60950-1:2001) 5x10 5x10 5x10 5x25 5x25 5x25 5x25 5x25 5x25 5x35 5x35 5x35 5x70 5x70 5x70 *only valid for common battery use Fuse C (Agl/CB) 3x63 3x63 3x63 3x100 3x100 3x100 3x100 3x100 3x100 3x125 3x125 3x125 3x200 3x200 3x200 Cable C (IEC 60950-1:2001) 4x10 4x10 4x10 4x25 4x25 4x25 4x25 4x25 4x25 4x35 4x35 4x35 4x70 4x70 4x70 Cable D (IEC 60950-1:2001) 5x10 5x10 5x10 5x25 5x25 5x25 5x25 5x25 5x25 5x35 5x35 5x35 5x70 5x70 5x70 Fuse E Cable E +/N/- +/N/- 3x32A 3x63A* 3x100A* 3x63A 3x100A* 3x125A* 3x63A 3x125A* 3x160A* 3x80A 3x125A* 3x200A* 3x100A 3x160A* 3x250A* 3x4 3x10* 3x25* 3x10 3x25* 3x35* 3x10 3x35* 3x50* 3x16 3x35* 3x70* 3x25 3x50* 3x120*
© Copyright 2026 Paperzz