CVH stage and roof – Specifications: Size: CVH Stage provides an effective covered floor area on 423m2. The CVH roof is 15,30 meters wide and 15,75 meters deep. Opening is 14,40 meters between the towers. Clearance is 9 meters The stage floor measures a total of 25,20 x 14,4 meters. Performance area measures 14,40x14,40 meters. incl. backstage prepare area. Net aprx. 8 meters for artists (Kløften Festival only) . Floor: (Nordic Staging System) Nordic Staging System Bearing construction: Aluminium Floor surface: 21mm phenol-glued Baltic birch plywood with a skid-proof surface Floor height: 1,6 - 1,8 metre Floor stress capacity: 750 kg per square metre Handrails: Along all outside edges – height: 1,1 metre Roof: (CVH and ATC Truss System) Roof construction: CVH Aluminium Truss Vertical towers: ATC Aluminium Truss Roof covering: Black fireproof PVC tarpaulin Vertical side cover: Black fireproof PVC tarpaulin Wind support: Internal windbraces of steelrope, and a total of 6t. of steelballast Wind force: Maximum 12 m/ sec. (with all vertical side covers) Standard equipment: Stairs: Two adjustable stairs with handrail for the stage, and one for the loadingdock. Loading dock including ramp for stage 2,4 x 7,2 metre and 1,2 metre in height FOH: 6x6 metre in one floor level covered with black fireproof tarpaulin, nd with a solid black rubber floor. Roll-risers: 4 pcs. á 2.4 x 2.4 meters. Risers comes in 2 hights: 40cm & 60cm Crowd barriers: 20 Nordic Crowd Barriers - 1,15 meters each - in front of the stage Technical tents: Two, 1 for sound and one for backline, 4,8 x 14,4 metre covered with black fireproof tarpaulin.