Installation Requirements Slayer Espresso 2-group Counter 30.5 in / 77.5 cm • Width: 30.5 inches / 77.5 centimeters 2.75 in / 7 cm 4.75 in / 12 cm • Weight: 220 lbs / 100 kg (tanks filled) Measurements do not include overhanging wood components: portafilters, brew actuators, steam handles, cup rails 17 in / 43.5 cm • Height: 17 inches / 43.5 centimeters Ø 2 in / 5 cm Ø 2.75 in / 7 cm 26.5 in / 67.5 cm • Length: 26.5 inches / 67.5 centimeters Drip tray edge Water • 3/8-inch BSP dedicated cold water line with shutoff valve (in North America, 3/8-inch compression fitting is included) • Incoming water pressure: 3 Bar min, 5 Bar max • Water hardness cannot exceed 50ppm, otherwise a water softener is needed Power 9 bars • Single-phase: 200-260 volts AC, 50/60 hertz, 26 amps, 5,700 watts • Three-phase: 380-400 volts AC, 50/60 hertz, 17 amps, 5,700 watts Line pressure to hot water mix valve Water line in • Receptacle: Nema 6-50 *Male plug end is included only when UL specifications have been requested Drain • Open gravity drain located within 4 feet / 1.2 meters of the machine • Ensure drain line is always sloping downwards Requires 220 V, 30 A, singlephase male plug end* Drain hose Water filter • Drain hose: 7/8-inch outside diameter, 5/8inch inside diameter (2.2-centimeter outside diameter, 1.6-centimeter inside diameter) 3/8-inch water line connects to water system with shutoff valve Water line in ® P +1 2 0 6 28 4 7 1 7 1 F +1 2 0 6 28 4 7 76 6 S U P P O R T@ S L AY E R E S P R E S S O .C O M 61 3 3 6 T H A V E S . S E AT T L E , W A 9 81 0 8 S L AY E R E S P R E S S O .C O M