APPLICATION NOTE For Your Information ... #45 Using a Photocell with the RadioRA® System Overview The RadioRA system has the ability to accept Class 2 dry contact closures to automatically control lights in a home. There are times when photocell functions are desired so that lighting events change with background light levels. This can be accomplished by using an external photocell as shown below. Wiring The wiring diagram below uses a RadioRA Multi-Function Entry Master Control or a Switch Closure Interface, and a photocell Manufactured by PLC Multipoint, Inc. Using the RadioRA Setup Guide or RAMC-MFE Setup and Installation Guide, an input on the RA-SCI or RAMCMFE can be programmed to the MAINTAINED function such that a maintained switch closure will turn a SCENE ON. The input SCENE turns on when the switch closure is made. When released, the input SCENE returns to OFF. For information on purchasing this photocell, contact PLC Multipoint at: 3101 111th Street SW, Suite F Everett, WA 98204 (425) 353-7552 Photocell Wiring for Multi-Function Entry Master Control RadioRA Dimmer(s) and/or Switch(es) RF Multi-Function Entry Master Control Model No. RA-MFE N.O. 6 7 8 N.C. COM To 9 VAC Transformer (Supplied) PLC Multipoint, Inc. LC8 Single Level r 2 1 2 CCO 2 OUTPUTS 5 COM 4 FLASH FULL 3 CCI 1 1 CCO 1 2 CCI 2 COM +24 1 INPUTS Green Scene 1 Green Ground Plug-in Transf T ormer Common PLC Photocell 24 VAC or VDC (not supplied by PLC) PLC Photocell Models Include: PLC Number Housing PC1A Indoor PC5AD PC9 PC9AD Outdoor tr Skylight Foot Candle e 40 400 ñ 3000 FC Need additional assistance? Call the Lutron Technical Support Center 1-800-523-9466 Please provide exact model number when calling. Photocell Wiring for Switch Closure Interface RadioRA Dimmer(s) and/or Switch(es) RF Switch Closure Interface Model No. RA-SCI TM Coopersburg, P PA USA ace m Power Input Select Input 5 Input 3 Input 2 Flash Full n Closure Input 1 Input 2 N.O. 6 7 Input 3 8 N.C. Input 4 COM Guide for operating instr PLC Multipoint, Inc. LC8 Single Level r o y COM +24 2 3 4 5 Class 2 connection only h AC IN Green l 1 To AC Transformer (Supplied) Scene 1 Green Ground Plug-in Transf T ormer Common PLC Photocell 24 VAC or DC by PLC) PLC Photocell Models Include: PLC Number Housing PC1A PC5 PC5AD PC9 PC9AD Outdoor Foot Candle e Indoor Skylight 400 ñ 3000 FC Operation SCENE 1: Turn some exterior landscape lighting ON at dusk and OFF at dawn. 1. Using the RadioRA Setup Guide or the RAMC-MFE Setup and Installation Guide, configure CCI 1 on the RadioRA Multi-Function Entry Master Control (RAMC-MFE) or input 1 on the Switch Closure Interface (RASCI) to the MAINTAINED function for control of the RadioRA Dimmers, Switches or GRAFIK Eye® Control Units that control exterior landscape lighting. 2. Configure the output circuit of the photocell to provide a maintained ON closure when the photocell senses its LOW setpoint and a maintained OFF closure when the photocell senses its HIGH setpoint. (Setpoints can be calibrated to the actual desired light level. See instructions provided with photocell.) 3. Wire CCI 1 and common or input 1 and common as shown in the wiring diagram on page one. OPERATION: As dusk arrives and the photocell senses that the background light level is reaching the LOW setpoint, the photocell will provide a maintained ON closure to CCI 1 on the RAMC-MFE or input 1 on the RASCI. The RAMC-MFE or RA-SCI will turn scene 1 ON to its preprogrammed light levels (in this case the andscape lighting). As dawn approaches and the background light level reaches the HIGH setpoint, the photocell will turn its closure OFF, which will open the MAINTAINED closure on the RAMC-MFE CCI 1 or RA-SCI input 1, which will turn scene 1 (the landscape lighting) OFF. Other inputs may be dedicated to other functions such as timeclock, telephone interface, motion sensor, pressure pad, etc. Lutron Electronics Co., Inc. Worldwide Technical and Sales 7200 Suter Road Assistance Coopersburg, PA 18036-1299 U.S.A. If you need assistance call the toll-free Lutron Phone: (610) 282-3800 Technical Support Center. Please provide exact Fax: (610) 282-3090 model number when calling. (800) 523-9466 (U.S.A., Canada, and the Caribbean) Other countries call (610) 282-3800 Visit our Website at www.lutron.com Lutron, GRAFIK Eye, and RadioRA are registered trademarks of Lutron Electronics Co., Inc. © 1998 - 2002 Lutron Electronics Co., Inc. Need additional assistance? Call the Lutron Technical Support Center 1-800-523-9466 Please provide exact model number when calling. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. Made and printed in U.S.A. 6/02 P/N 366-634 Rev. B
© Copyright 2026 Paperzz