Raider® Rooftop Units 3 to 5 Tons Net Cooling Capacity − 34,600 to

PA C KA G E D G A S / e l e c t r i c
ZG
Raider® Rooftop Units
60 HZ
P R O D U C T S P E C I F I C AT I O N S
Bulletin No. 210655
March 2014
Supersedes December 2013
Value Without Compromise™
$6+5$(
COMPLIANT
3 to 5 Tons
1HW&RROLQJ&DSDFLW\ïWR%WXK
*DV,QSXW+HDW&DSDFLW\ïWR%WXK
MODEL NUMBER IDENTIFICATION
Z G A 060 S 4 B S 1 Y
Voltage
3 9íSKDVHK]
< 9SKDVHK]
* 9SKDVHK]
- 9SKDVHK]
Brand/Family
Z = Raider® Product Line
Unit Type
G = Packaged Gas Heat w/ Electric Cooling
Minor D
Design
i S
Sequence
1 = 1st Revision
2 = 2nd Revision
3 = 3rd Revision
Major Design Sequence
A = 1st Generation
B = 2nd Generation
Nominal Cooling Capacity - Tons
036 = 3 Tons
048 = 4 Tons
060 = 5 Tons
&RROLQJ(I¿FLHQF\
6 6WDQGDUG(I¿FLHQF\
Refrigerant Type
4 = R-410A
Heating T
Type
S = Standard Gas Heat, 1 Stage
M = Medium Gas Heat, 1 Stage
H = High Gas Heat, 2 Stage
T = High Gas Heat, 1 Stage
U = Medium Gas Heat, 2 Stage
Q = Medium Gas Heat, 2 Stage, Low NOx
W = Standard Gas Heat, 1 Stage, Low NOx
Y = Medium Gas Heat, 1 Stage, Low NOx
X = High Gas Heat, 2 Stage, Low NOx
Z = High Gas Heat, 1 Stage, Low NOx
Blower T
Type
B = Belt Drive
FEATURES AND BENEFITS
H
L
G
J
D
E
C
F
K
B
I
Raider® rooftop units from Lennox DUHWKHQHZVWDQGDUGIRUFRVWHI¿FLHQWUHOLDEOHURRIWRS
XQLWVEXLOWIRUORQJODVWLQJSHUIRUPDQFHWKDWFDQVLJQL¿FDQWO\LPSURYHLQGRRUHQYLURQPHQWV
Raider® rooftop units feature:
•
•
•
•
•
•
•
•
•
4XLFNDQG(DV\5HWUR¿W)DVWLQVWDOODWLRQIRUUHSODFHPHQWRIPDQ\H[LVWLQJURRIWRS
XQLWV¿WVKLJKYROXPHFRPSHWLWRU¶VURRIFXUEV
R-410A Refrigerant -(QYLURQPHQWDOO\IULHQGO\
Scroll Compressors - Single speed scroll compressor is furnished on all models.
Lennox’ Environ™ Coil System - Smaller, lighter condenser coil.
High Pressure Switch - Protects compressor.
Belt Drive Blower Motor -7RPD[LPL]HDLUSHUIRUPDQFH
'RZQÀRZRU+RUL]RQWDO$LUÀRZ(DV\¿HOGFRQYHUVLRQ
Two Fork Lift Slots on Three Sides -(DV\WRSLFNXSDQGWUDQVSRUWXQLWVIURPDOPRVW
DQ\DQJOH
Corrosion-Resistant Drain Pan -3URYLGHVDSSOLFDWLRQÀH[LELOLW\GXUDELOLW\LPSURYHG
VHUYLFHDELOLW\DQGPHHWV$6+5$(UHTXLUHPHQWVIRUGUDLQSDQVORSH
Raider® Packaged Gas / Electric 3 to 5 Tons / Page 2
FEATURES AND BENEFITS
&217(176
$FFHVVRU\'LPHQVLRQV . . . . . . . . . . . . . . . .
Blower Data . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . .
Electrical Data. . . . . . . . . . . . . . . . . . . . .
)HDWXUHV$QG%HQH¿WV . . . . . . . . . . . . . . . .
High Altitude Derate . . . . . . . . . . . . . . . . .
0RGHO1XPEHU,GHQWL¿FDWLRQ . . . . . . . . . . . . .
2SWLRQDO&RQYHQWLRQDO7HPSHUDWXUH&RQWURO6\VWHPV
Options / Accessories . . . . . . . . . . . . . . . . .
Outdoor Sound Data . . . . . . . . . . . . . . . . .
Ratings . . . . . . . . . . . . . . . . . . . . . . . .
6SHFL¿FDWLRQV . . . . . . . . . . . . . . . . . . . . .
6SHFL¿FDWLRQV*DV+HDW . . . . . . . . . . . . . . .
Unit Clearances . . . . . . . . . . . . . . . . . . . .
Weight Data . . . . . . . . . . . . . . . . . . . . . .
$33529$/6
$+5,&HUWL¿HGWR$+5,6WDQGDUG
210/240-2008.
CSA listed.
8QLWVDUH&HUWL¿HGE\&6$
Components bonded for grounding
WRPHHWVDIHW\VWDQGDUGVIRU
VHUYLFLQJUHTXLUHGE\8/8/&DQG
National and Canadian Electrical
Codes.
All models are ASHRAE 90.1
compliant.
ISO 9001 Registered
0DQXIDFWXULQJ4XDOLW\6\VWHP
0RGHOVHTXLSSHGZLWKORZ12[JDV
heat meet the California Nitrogen
2[LGHV12[6WDQGDUGVWKDWDSSO\
LQWKH6RXWK&RDVW$LU4XDOLW\
Management District and the San
)UDQFLVFR%D\$UHD$LU4XDOLW\
Management District.
:$55$17<
/LPLWHGWHQ\HDUVDOXPLQL]HGKHDW
exchanger.
/LPLWHG¿YH\HDUVRQFRPSUHVVRUV
/LPLWHGWKUHH\HDUVRQWKH
/HQQR[¶(QYLURQŒ&RLO6\VWHP
/LPLWHG¿YH\HDUV2SWLRQDO+LJK
3HUIRUPDQFH(FRQRPL]HUV
/LPLWHGRQH\HDUDOORWKHUFRYHUHG
components.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.24
.14
.23
.19
. 2
.12
. 1
.21
. 9
.21
.13
.11
.12
.20
.22
+($7,1*6<67(0
B $OXPLQL]HGVWHHOLQVKRWEXUQHUV
direct spark ignition, electronic
ÀDPHVHQVRUFRPEXVWLRQDLU
inducer, redundant automatic
single or dual stage gas valve with
manual shut-off.
C Heat Exchanger
7XEXODUFRQVWUXFWLRQDOXPLQL]HG
VWHHOOLIHF\FOHWHVWHG
D Electronic Pilot Ignition
Electronic spark igniter provides
positive direct ignition of burners
RQHDFKRSHUDWLQJF\FOH7KH
V\VWHPSHUPLWVPDLQJDVYDOYHWR
VWD\RSHQRQO\ZKHQWKHEXUQHUV
are proven to be lit. Should a
ORVVRIÀDPHRFFXUWKHJDVYDOYH
closes, shutting off the gas to
the burners. Ignition module has
LED to indicate status and aid in
troubleshooting.
Watchguard circuit on module
DXWRPDWLFDOO\UHVHWVLJQLWLRQ
controls after one hour of
continuous thermostat demand
after unit lockout, eliminating
nuisance service calls. Ignition
FRQWUROLVIDFWRU\LQVWDOOHGLQWKH
controls section.
Limit Controls
)DFWRU\LQVWDOOHGUHGXQGDQWOLPLW
FRQWUROVZLWK¿[HGWHPSHUDWXUH
setting.
Heat limit controls protect heat
exchanger and other components
from overheating.
Safety Switches
)ODPHUROORXWVZLWFKÀDPHVHQVRU
and combustion air inducer proving
VZLWFKSURWHFWV\VWHPRSHUDWLRQ
Low NOx Models
All models are available in low NOx
versions.
Required Selections
Gas Input Choice - Order one:
• Standard Gas Heat (1 Stage)
65,000 Btuh
• Medium Gas Heat (1 Stage)
108,000 Btuh
• Medium Gas Heat (2 Stage)
75,600/108,000 Btuh
• High Gas Heat (1 Stage)
150,000 Btuh
• High Gas Heat (2 Stage)
105,000/150,000 Btuh
Standard or Low NOx
6SHFLI\FRQYHQWLRQDOJDVKHDWRU
Low NOx option.
Options/Accessories
Field Installed
LPG/Propane Kits
&RQYHUVLRQNLWWR¿HOGFKDQJHRYHU
units from Natural Gas to LPG/
Propane.
Vertical Vent Extension Kit
8VHWRH[KDXVWÀXHJDVHV
YHUWLFDOO\DERYHXQLW5HTXLUHG
when unit vent is too close to fresh
air intakes per building codes. The
vent kit also prevents ice formation
on intake louvers.
Raider® Packaged Gas / Electric 3 to 5 Tons/ Page 3