ENERGY CABLES Electric Utility Cables Paper Lead 3C 6.35/11kV, Copper (Belted) APPLICATION In urban networks for primary supply to underground residential distribution substations. Main feeders to commercial and industrial projects. The lead sheath provides an earth fault capacity adequate for many installations. MDPE offers improved abrasion and chemical resistance over PVC. Pressure terminations are recommended for these cables. STANDARD VOLTAGE CONDUCTOR INSULATION METALLIC SHEATH SHEATH MAX. OPERATING TEMP. AS/NZS 1026 BS 6480 6350/11000V Shaped Compacted Annealed Copper Mass Impregnated (Non Draining) Paper Extruded lead alloy E MDPE, HDPE or PVC, 5V-90 65 °C TECHNICAL SPECIFICATIONS CONDUCTOR APPROX. OVERALL DIAMETER APPROX. MASS MINIMUM BENDING RADIUS mm2 (No./mm) MAXIMUM mm Kg/Km INSTALLED mm 16 25 35 50 70 95 120 150 185 240 300 7 strands 7 strands 7 strands 19 strands 19 strands 19 strands 19 strands 19 strands 37 strands 37 strands 37 strands 32.4 35.5 38.6 37.2 40.6 44.2 47.2 50.2 53.8 58.8 63.3 2600 3200 3800 4100 5100 6200 7400 8600 10200 12500 15100 490 540 580 560 610 670 710 780 810 890 950 New Zealand/Energy/Electric Utility Cables/MV Paper Lead/Belted/3C, Copper │ VERSION: DURING INSTALLATION mm 810 890 870 930 1020 1110 1180 1260 1350 1470 1590 Lengths and packing can be supplied to customer’s requirements. For glanding details, contact your local service centre. Bending radii to AS/NZS 4026 TECHNICAL SPECIFICATIONS - Continued NOMINAL AREA mm² CURRENT RATING (a) ELECTRICAL CHARACTERISTICS Buried Direct Max. DC Resistance @ 20°C ohm/km Buried In Ducts Max. AC Resistance @ 65°C ohm/km Inductance mH/km Equivalent Star Reactance ohm/km Capacitance µF/km 3 Phase Voltage Drop mV/A.m 1 Sec Fault Rating (b) 3 Phase Symmetrical kA 2.350 1.490 1.081 0.803 0.565 0.429 0.340 0.285 0.240 0.199 0.175 1.1 1.8 2.3 3.2 4.6 6.5 8.1 10.0 12.4 16.2 20.3 A A 16 89 76 1.15 1.35 0.36 0.113 0.239 25 115 99 0.727 0.856 0.33 0.104 0.276 35 140 120 0.524 0.617 0.29 0.091 0.341 50 165 140 0.387 0.456 0.27 0.086 0.370 70 205 175 0.268 0.316 0.26 0.082 0.422 95 245 210 0.193 0.235 0.25 0.078 0.461 120 280 240 0.153 0.181 0.24 0.076 0.522 150 315 265 0.124 0.147 0.24 0.074 0.565 185 355 300 0.099 0.118 0.23 0.073 0.619 240 410 355 0.075 0.0907 0.23 0.071 0.692 300 460 395 0.060 0.0733 0.22 0.069 0.760 (a) Based on 65°C maximum conductor temperature, burial depth of 0.8m, soil temperature of 15°C and thermal resistivity of 1.2°Cm/W. (b) For fault durations other than one second, divide the appropriate given value by the square root of the required time (in seconds). Conductor fault ratings are based on an initial temperature of 65°C and a final temperature of 160°C. CONDUCTOR NOMINAL AREA mm2 NOMINAL DEPTH mm LEAD ALLOY SHEATH MIN. INSULATION BETWEEN CONDUCTOR & SHEATH mm MINIMUM THICKNESS mm DIAMETER OVER SHEATH MINIMUM MAXIMUM mm mm NOMINAL AREA mm² 16 5.1 3.4 1.4 28.6 29.8 126 25 6.4 3.4 1.5 31.7 32.9 154 35 6.0 3.4 1.6 30.1 31.4 151 50 6.9 3.4 1.7 33.6 34.9 184 70 8.3 3.4 1.8 35.3 36.6 198 95 9.8 3.4 1.9 38.7 40.0 235 120 11.0 3.4 1.9 41.2 42.5 250 150 12.3 3.4 2.0 44.1 45.4 282 185 13.7 3.4 2.1 47.2 48.6 316 240 15.6 3.4 2.3 51.6 53.0 376 300 17.5 3.4 2.4 56.4 57.8 437 (c) For fault durations other than one second, divide the appropriate given value by the square root of the required time (in seconds). 1 SEC FAULT RATING (c) kA 3.8 4.7 4.6 5.6 6.0 7.1 7.6 8.5 9.6 11.4 13.3 Sheath fault ratings are based on an initial temperature of 55°C and a final temperature of 250°C. GENERAL CABLE NEW ZEALAND LIMITED 75 – 89 Main South Road Riccarton, Christchurch PO Box 8044, Riccarton, Christchurch, New Zealand Phone: 0800 CABLES (0800 222 537) FAX: 0800 242 267 EMAIL: [email protected] New Zealand/Energy/Electric Utility Cables/MV Paper Lead/Belted/3C, Copper │ VERSION: 3C Copper v050412
© Copyright 2025 Paperzz