UserManual iSense30%or100%CO2&25%or95%O2DataLogger ‐NEMA4 Models CM‐0053 CM‐0054 CM‐0176 CM‐0204 Rev.March,2016 Copyright©2016CO2Meter,Inc.AllRightsReserved. CO2 + Oxygen Monitor Logger CO2Meter Savemeterinformationforfuturereference ModelNumber: SerialNumber: PurchaseDate: WARNING! InstallGasLab®softwarebeforeconnectingyourCO2Meterproduct(s)toyourcomputer. Foryourfreedownloadpleasevisithttp://www.co2meter.com/pages/downloadsFailuretodoso mayaffecttheabilityforGasLab®todetectyourmeter. PAGE2 of19 CO2 + Oxygen Monitor Logger CO2Meter TableofContents WELCOME......................................................................................................................4 IMPORTANTSAFEGUARDS.......................................................................................4 PACKAGECONTENTS..................................................................................................5 OPTIONALACCESSORIES...................................................................................................................5 GASLAB®SOFTWARE................................................................................................5 MINIMUMSYSTEMREQUIREMENTS................................................................................................5 POWERINGTHEMETER............................................................................................7 PRODUCTOVERVIEW.................................................................................................7 THEORYOFOPERATION....................................................................................................................7 INSTRUMENTOVERVIEW...................................................................................................................8 USBTORS485CABLE.....................................................................................................................8 SETUPWITHOPTIONALCM‐0182.................................................................................................9 SETUPFORMODELSCM‐0054ANDCM‐0053..........................................................................9 ANALOG4‐20MAOUTPUTS...........................................................................................................10 OPERATIONGUIDE...................................................................................................10 CONNECTINGMETERS.....................................................................................................................11 LCDDISPLAY....................................................................................................................................11 DATASTORAGE.................................................................................................................................11 LOGGINGDATA.................................................................................................................................11 SOFTWARESETTINGS.............................................................................................12 DISPLAYSETTINGS...........................................................................................................................12 OUTPUTSSETTINGS..........................................................................................................................12 PORTSETTINGS.................................................................................................................................12 TIME/DATESETTINGS....................................................................................................................12 LOGGINGSETTINGS..........................................................................................................................12 CALIBRATION............................................................................................................14 CALIBRATIONPROCEDURE..............................................................................................................14 APPENDIX...................................................................................................................16 METERSPECIFICATIONS..................................................................................................................16 TROUBLESHOOTINGGUIDE..................................................................................17 USBDRIVERINSTALLATIONINSTRUCTIONS...............................................................................18 SUPPORT.....................................................................................................................18 WARRANTY................................................................................................................18 LIABILITY....................................................................................................................19 RETURNS.....................................................................................................................19 CONTACTUS...............................................................................................................19 PAGE3 of19 CO2 + Oxygen Monitor Logger CO2Meter Welcome Thankyouforpurchasingourmeter.CO2Meter,Inc.isaFloridabasedbusinessspecializinginthe designandmanufacturingofgasdetectionandmonitoringdevices–mainlyCO2.Ourapproachis onebasedinthescienceofgasandhowbesttoaccuratelyandrepeatedlymeasurethatgasforthe enduserspurposes.OurbusinesspartnersinAgriculture,Medical,Pharmaceuticals,Science, Beverage,andotherfieldsfindourdevicestobehighlyaccurateandcosteffective. Weapproacheachcustomer’sapplicationasauniqueopportunitytounderstand,educate,and provideproductsolutionsthatmeetthecustomers’needswhileexceedingtheirexpectationsfor reliabilityandservice.Ourcontinuedproductinnovationincombinationwithour“customerfirst” focusallowsCO2Meter,Inc.tocontinuetoprovidesolutionsforthefuture. BasedinOrmondBeach,FL,CO2Meter,Inc.iscommittedtothesuccessofourcustomers;the health,welfare,andprosperityofourtalentedemployees;andthecontinueddevelopmentofour localcommunity. CO2Meter,Inc.appreciatesyourbusinessandlooksforwardtoworkingwithyouandyourteamin thefuture. Pleasetakesometimetoreadthroughthismanualinordertobecomefamiliarwiththemeter.Also, pleasepayspecialattentiontotheimportantsafeguardsshownonthenextpage. ImportantSafeguards Toreducetheriskoffire,electricalshockand/orinjurytopersons,basicsafetyprecautionsshould alwaysbefollowedwhenusingelectricalappliances,includingthefollowing: 1. 2. 3. 4. 5. 6. 7. READALLINSTRUCTIONSBEFOREUSINGTHISMETER. INSTALLGasLab®SOFTWAREBEFORECONNECTINGMETERTOACOMPUTER. Useonlytheincludedpowersupplytooperatethismeter. Makesurethatthetubesaresecurelyattachedtothemeterbeforesamplingaclosed environment. Donotoperatewithanobstructedsamplepath. Donotoperatethismeteriftheenclosureisopened. Donotoperatethedeviceifitismalfunctioning. SAVETHESEINSTRUCTIONS! PAGE4 of19 CO2 + Oxygen Monitor Logger CO2Meter PackageContents Pleaseverifythatyourpackagecontainsthefollowingitemsbeforeusingthemeter: ALLUNITS: (1)Meter (1)6‐footUSBCable (1)Fittings,tubing,&filterkit (1)CalibrationCertificateTag (1)Usermanual (1)M12,12‐Pos.5‐meterCable Figure1:BasicKit OptionalAccessories Figure2:WithCM‐0182Kit 12‐Pos.M12RS485‐USBCablewithDCBarrelJackandInternationalPowerSupply(CM‐0182) asshowninFigure2. Note:Pleasecontactourtechnicalsupportstaffformoredetailsabouttheseaccessories. GasLab®Software IMPORTANT:MAKESURETOINSTALLSOFTWAREBEFORECONNECTINGYOURMETERTOYOUR COMPUTER. MinimumSystemRequirements Toutilizeourfreesoftware,thecomputermustmeetthefollowingminimumrequirements: 1GHzprocessorswith1GBRAM1GBfreediskspace(2GBfreediskspacefor64‐bit systems). WindowsXP*/7/8/8.1withMicrosoft.NETFramework4.0**orlater. OnIntel‐basedMaccomputers,GasLab®softwarecanrunusingaWindows7/8virtual machinesoftwaresuchasVMwareFusion®orsimilar. *Microsoft.NETisnotsupportedonMediaCenterorTableteditions. PAGE5 of19 CO2 + Oxygen Monitor Logger CO2Meter **Installerwilloptionallyinstall.NETFramework. Visitwww.co2meter.com/pages/downloadstodownloadourcomplimentaryGasLab®software toyourcomputer.YoucanalsodownloadtheGasLab®usermanualinPDFfromthispage. PleasereadtheGasLab®usermanualcarefullytobecomemorefamiliarwithhowthesoftware workssothatyoucangetthemaximumbenefitfromthisusefultool. InstalltheGasLab®softwarefirsttoensurethattheproperdriver,necessaryforthemeter,is installedonyourcomputerbeforeconnectingthemeter. Figure3:GasLab®downloadpage(InternetExplorer11shown) Followthestepsandinstructionspromptedbyyourcomputer’soperatingsystem.Makesureyou haveadministratorprivilegesinordertoinstallthisprogram. NOTE:WestronglyrecommendallowingGasLab®toinstalldriversforthemeterautomatically. SoftwareCapabilities OurGasLab®softwarewillallowusersto: Manageanddownloadlogs Configuresensor Adjustloggingintervals Calibratethemeter AutomaticdataloggingwhenmeterispoweredON DataloggingsessionstatusdisplayedonLCDscreen Collectdatareal‐time PAGE6 of19 CO2 + Oxygen Monitor Logger CO2Meter PoweringtheMeter Thismonitorloggerrequiresdirecthardwiringto24VDCpowersourceusingtheM12cable included,unlessthe12‐Pos.RS485CablewithPower(CM‐0182)ispurchased,whichcontainsa universalpowersupply. ProductOverview ThisCO2Meter,Inc.monitorloggerisdesignedtomeasurecarbondioxide(CO2)andoxygen(O2), logdataandcontrolconcentrationlevels.Itstoresupto15,000collecteddatapointstoitsinternal memorytoberetrievedatalatertimeforanalysis.WhencombinedwithourGasLab®software, youcanalsoseereal‐timedataonyourcomputer’sscreen.Itsbuilt‐in1,000hourssamplingmicro‐ pumpensuresreliableoperationforpersistentreadingsbasedonuser‐selectedtimeintervals.With variousoutputs,arelayandweather‐proofconnectors,thismeteriscertainlyaheavyhitteramong gassensingdevices. Scientificdevicessuchasthismonitorloggerrequiretheusertohaveanintimateknowledgeofthe meter,itsoperation,therequiredsoftware,andthemeterspecificationspriortouse.CO2Meter,Inc. highlyrecommendsreadingthisuser’smanualbeforeoperatingthedevice,especiallythe ImportantSafeguardssectiononpage4. TheoryofOperation TheCO2sensorinsidethismeterusesNDIR(non‐dispersiveinfrared)technologytosense,asa functionoftransmittedlight,theconcentrationofCO2intheair.Tomeasureoxygen,thismeterhas anextremelyaccurateZirconiaO2sensor.Thismeterhasbeenfactorycalibratedtooperatewithin thespecifiedrangeandprecision. PAGE7 of19 CO2 + Oxygen Monitor Logger CO2Meter InstrumentOverview LCDDisplay IN/OUT BarbFittings Mini‐USB Portwithcap M12Connector Figure4:Metercomponents USBtoRS485Cable ThiscableprovidesaUSBplugwithanintegratedUSB/RS485converterandterminatesinan RJ485plug.OnlythethreeconductorsD1,D0andCommonarepresent.Thiscablesallowsahost PC(withsuitablesoftware)tocommunicatewithmultipleRS485devicesonthecable. FTDI‐USBtoModbusRJ45Wiring RJ45PIN FTDIUSBColor Cat‐5Color 4 Orange(B) Blue 5 Yellow (A) White/Blue 8 Black (G) Brown RS‐485Output PleaseseeourwebsiteforadvancedRS‐485documentationandregisterdescriptions. NOTE:Themetercomeswithapre‐wiredconnectorthatincludesaRS‐485cableandan18or 24VDCinternationalpowersupply. PAGE8 of19 CO2 + Oxygen Monitor Logger CO2Meter SetupconnectingtheoptionalCM‐00182 Thesamplingdeviceispre‐wired.Themostimportantaspectofsetupinvolvesconnectingthe samplinghosesandensuringpropersetup.DCpowersupplyhastobeconnectedtothebarrel connectorinthemateconnectortosupplythevoltagetotheunit. Includedinthepackageisthematingendofthe12‐pinconnectoronthebottomoftheunit.This connectoristohavematingwiressolderedontoitandthenassembled. Theconnectorpinsarelabelsforidentification.Theguidebelowgivestheelectricalconnections necessaryforusage. Figure5:M12connector12pin PermanentInstallation Ifusedinapermanentinstallation,thesemeterscanbepoweredby24VDCpower.The4‐20mA outputloopwillbepoweredinthissituationforusewithexternalcontrollers.TheRS‐485and RelayoutputsforNC&NOoperationsareindicateonthenextLegend. SetupconnectingtheM12,12‐Pos5Mcableincluded Thesamplingdevicewillrequireminimalsetup.Themostimportantaspectofsetupinvolves connectingthesamplinghosesandensuringproperenvironmentalsetup. Includedinthepackageisthematingendofthe12‐pinconnectoronthebottomoftheunit.This connectoristohavematingwiressolderedontoitandthenassembled. PAGE9 of19 CO2 + Oxygen Monitor Logger CO2Meter TheconnectorpinsarelabelsforidentificationandthewirelegendshowninthetableonFigure6 belowshowsthefunctionalityofeachwireoftheelectricalconnection. Pin# WireColor ColorLegend Description 1 Brown CO24‐20mA‐ 2 Blue N/ORelay 3 White CO24‐20mA+ 4 Green RS‐485Ground 5 Pink N/CRelay 6 Yellow COMRelay 7 Black PowerGround 8 Grey O24‐20mA‐ 9 Red VoltageInput 10 Purple O24‐20mA+ 11 Pink/Grey RS‐485B 12 Red/Blue RS‐485A Figure6:Wirecolorlegendfor12‐pinconnector Analog4‐20mAOutputs Thismeterfeaturesdual4‐20mAoutputlinearlyscaledtothecurrentCO2andO2readings,in additiontoadigitalRS‐485interfaceforconnectiontoaMODBUSnetworkandonerelay1A, 30VDC.Theseoutputsarepoweredbytheinputsupplyandwerecommendusinga250Ωresistor loadtomeasuretheoutput.Theexactmaximumdrivableloadwillbedeterminedbytheinput powersupply,inaccordancewithOhm’sLaw.Theloopscalingissetupasfollows: OxygenLoopOutput:0‐25%or0‐95%O2,dependingonmetermodel. CarbonDioxideLoopOutput:0‐30%or0‐100%CO2,dependingonmetermodel. OperationGuide Makesureyoureadthroughtheseinstructionsthoroughlybeforeusingthemeter.Thisguidewill helpyoubecomemorefamiliarwiththemeterinordertobeasproductiveaspossibleinashort periodoftime.PleasereadtheImportantSafeguardsonpage4beforecontinuing. IMPORTANT:Followtheseinstructionstoensurepropersetup: 1. DownloadtheGasLab®softwaretoyourcomputerasshownintheGasLab®Software sectiononpage5. 2. Powerthemeterbywiringdirectlytoa24VDCpowersourceorusingtheuniversalpower supplyiftheCM‐0182kitwaspurchased.TurnONthemeter. 3. Waituntilthedisplaychangescolorstovisuallyconfirmithasresetsuccessfullybefore connectingittoacomputer. PAGE10 of19 CO2 + Oxygen Monitor Logger CO2Meter ConnectingMeters Thefirsttimethemeterisconnectedtoyourcomputer,theoperatingsystemwillinstallthe necessaryUSBdriversasshowninFigure7.Thisprocesscouldtakeafewminutes. Figure7:USBDriverInstallation. LCDDisplay TheLiquidCrystalDisplay(LCD)showsthefollowingfeatures: Gasconcentrationlevelinparts‐per‐million(ppm)orinpercentageformat(##.##%)forallthe models LoggingON/OFF PumpON/OFF Percentageoffreememory Batteryusagein%/chargingmode Temperature(##.#C/F)/Humidity(##.#%)–optional DataStorage Thismeterfeaturesaninternalmemorycapableofstoring15,000datapoints.Duetothenatureof theirdesign,thesemeterswillneedtobeinitializedbeforeoperationanditsloggingperiodand real‐timeclockwillneedtobesetunderthe“Settings”menu. LoggingData OncetheGasLab®softwarehasbeeninstalledandthemeterisconnectedtothecomputer,youcan gatherdatainavarietyofways.Datacanbecollectedinrealtime,datalogscanbedownloaded fromthemeter’smemoryandsavedtothecomputer,anddatacanbereviewedonthemeter’sLCD display. Foreachloggingsession 1. TurnthemeterON. 2. Themetermustbestartedatleast1minutepriortodeploymentanddataloggingtoallow theCO2sensortimetowarm‐upandcalibrate. 3. Settheloggingintervalasdesiredandcommencelogging. 4. Whendataloggingiscompleted,turnthemeterOFF. NOTE:RefertotheGasLab®User’sManualformoreinformation. PAGE11 of19 CO2 + Oxygen Monitor Logger CO2Meter SoftwareSettings Settings–allowsyoutoaccessalltheparameters,options,outputs,communications,anddate/time settingstobechangedorprogrammed. DisplaySettings Hereyoucanchangethebrightnessandcolortheme(3available)onthedeviceandyoucanalso activateaScreenTimeouttosavepower.Thissettingwillnotaffectthemeter’sfunctionalitybutis importanttoindicatethatitwillaffectthebatterylifedependingonhowyousetthisparameter. OutputsSettings Hereyoucanchangetheparametersontherelaysandotheralerts. PortSettings Hereyoucanconfigureandactivateportsthatcontroladditionalaccessorieslikethedevice Modbusaddress.Pleasecalltechnicalsupportforguidanceandimportantinformationbefore makingchangestotheconfigurationofanyoftheseports.Youcanreachusduringregularbusiness hoursat(386)256‐[email protected]. Time/DateSettings Hereyoucanchangethedateandtimeonthemeterformoreaccuratereferenceontherecords. Thedefaulttimeofyourmetercouldvarydependingonyourlocation.Pleasereviewthese settingsbeforeyoustartusingthemeter. LoggingSettings Hereyoucanchangetheloggingintervalandduration.Thiswillenableyoutocollectthedatafora periodoftimeinaspecificlogginginterval.Thisscreenalsogivesyoutheoptiontosetthedesired pumpinterval.Remembertosynchronizethepumpbefore,during,oraftertheloggingintervalto readandcollectthecorrectreadingaccordingtotheapplication. ClosedLoopOperation Figure8:ClosedLoop PAGE12 of19 CO2 + Oxygen Monitor Logger CO2Meter OpenLoopwithEnvironmentalExhaust Figure9:OpenLoop Werecommendinstallingtheincludedhumidity/contaminatefiltertoensurethesensingchamber andpumpbafflestaysclearandcorrosionfree. Figure10:FilterInstallationandOrientation PAGE13 of19 CO2 + Oxygen Monitor Logger CO2Meter Calibration TheCO2sensor,inIAQapplicationsonly,usesanalgorithmcalledAutomaticBackground Calibration(ABC)toensuremaximumaccuracybycontinuouslyadjustingthezero‐point. TheABCalgorithmallowstheCO2sensortodynamicallyshiftitsCO2readingbyaconstant.It worksviastoringthelowestCO2sampletakenovertheABCPeriodandassumingthatthislow valueisequaltoaknownvalue(thetargetvalue).ItthenadjuststheoutputoftheCO2readingby thedeltabetweenthesevalues.Thisalgorithmdoesnotaffectthelinearizationoftheoutputsignal. Forexample,bydefaultABCisenabledwithanABCPeriodof180hours,atargetvalueof400ppm, andamaximumdeltaof30ppm.Thisoperatesundertheprinciplethatambient,outdoorairisat 400ppm. ThesensorwillkeeptrackofthelowestCO2readingrecordedoveraperiodof180hoursandthen adjustthezeropoint,upto30ppmatatime,towardsthatvalue. Toensuremaximumaccuracyitisrecommendedtoinstallthedeviceinanenvironmentthatwill routinelyseethislowvalue. Inaddition,thismetercanbeexposedtofreshairforafewminutesbetweenusestoverify calibrationbymakingsurethereadingsarecloseto400ppm,orcanbemanuallycalibratedusing theGasLab®softwareandtheproceduredescribedbelow. NOTE:RefertotheGasLab®User’sManualforcompleteinstructions. CalibrationProcedure–CO2 Tocalibrateyourmeter,followthesesteps: 1. 2. TurnONthepumponthemainscreen. Exposethemetertoambientair(assumedtobeat400ppm)orconnectittoacalibration gasbottle/cylinder(100%nitrogenorargon)withtheappropriatedemandregulator. Wait25secondstocollectasample.Writedownthisvalueasthe“before”value. Clickthe“Calibrate”buttonafterselectingyourcalibrationgas. Wait25secondsagain.Thistime,themeterwilltakeasampleandusethisdatatoadjust zerovalues.Thedisplayedmeasurementwillshowthenewcalibrationvalue(0or400ppm, dependingonmethodused). Disconnectthecalibrationgasandwait25seconds.Alldisplayeddatawillnowbebasedon thenewcalibrationvalue.Repeatthisprocedureifthesensorisstilloperatingoutsideofits specifiedrangeorifreadingsvarygreatly. 3. 4. 5. 6. PAGE14 of19 CO2 + Oxygen Monitor Logger CO2Meter CalibrationProcedure–Oxygen Tocalibrateyourmeter,followthesesteps: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. DownloadtheDASsoftwarefromtheCO2meter.comwebsitedownloadpage RuntheDASsoftwareandconnectthemetertoaUSBportonthecomputer. Clicktheiconin“ConnectedDevices”window. Click“ConfigureSensor”box. Inthe“ConfigureYourDevice”window,select“DataLogging”tab. Set“LogInterval”to“10”.Set“PumpPWM”to“1”. Set“PumpPeriod”,“WaitPeriod”and“IntegrationPeriod”to“0”. Set“PumpMode”to“ContinuouslyON”andclickonthe“Save”box. CyclepowerontheCM‐0054andplacetheCM‐0054initsoperatingenvironment. AllowtheCM‐0054towarmupinitsoperatingenvironmentforatleast1hourbefore performingthe“ZeroCalibration”. Connect100%Nitrogentotheinputandflowcontinuouslythroughoutthecalibration process. WaitforO2readingstocompletelystabilize.(Thiswilltake3to5minutes) Clickon“ConfigureSensor”box. Inthe“ConfigureYourDevice”window,select“OxygenCalibration”tab. Clickon“ZeroCalibrate”box. Allow100%Nitrogentoflowfor2minutesafterperforming“ZeroCalibration”andverify thereadingsarestableat0.00% Ifreadingsarenot0.00%after2minutes,repeatsteps12‐17untilstablereadingsof 0.00%areachieved. Allowthemetertowarmupandstabilizeinitsoperatingenvironmentiskeytomaximum accuracy.KeepthemeterONwiththepumprunningcontinuouslyforhighestaccuracy. PAGE15 of19 CO2 + Oxygen Monitor Logger CO2Meter Appendix A. MeterSpecifications SensorType:CO2 O2 MeasuringRange: 30%or100%CO2 25%or95%O2 Repeatability:CO2 O2 Accuracy:CO2 Non‐dispersiveinfrared(NDIR) Zirconiumdioxide(ZrO2) 0‐30%or0‐100%vol. 0‐25%or0‐95% ±0.1%,±2%ofmeasuredvalue ±20ppm,±1%measuredvalue ±0.5%vol.,±3%ofmeasured value O2 ±2%fullscale CO2SensorRatings: LifeExpectancy MaintenanceInterval Warm‐upTime O2SensorRatings: LifeExpectancy MaintenanceInterval Warm‐upTime DataLogging:DataPoints ProgrammableIntervalData PumpCharacteristics: LifeExpectancy Power:InputVoltage PowerConsumption Outputs:CO2/O2 Readings >15years Nomaintenancerequired <5 min(instantmeasurements) >15years Nomaintenancerequired <5min(instantmeasurements) 15,000 Date,time,CO2,%RH,temp. 10,000hours 18‐30VDC ~5Wavg.(pumprunning) 4‐20mAorRS‐485 MODBUS (M12connectoronly) Relay COM,NC,NO,1A@30VDC PhysicalDimensions: Inches(mm) WxHxD 7.1(180)x4.7(120) x2.4(60) PAGE16 of19 CO2 + Oxygen Monitor Logger CO2Meter TroubleshootingGuide Symptom/ Issue PossibleCause Resolution Meter/Sensoris notrecognized bycomputer/OS ordoesn’tpower ON Improperpower connectionoradapter (ifsuited)notconnected properly. Verifythewiringdiagramfor properpowerconnectionor connectmetertothepower supply(ifpurchased)andpower meterON. SeenextUSBDriverInstallation Instructionssectionnext. USBdriverinstalledin yourcomputermightbe wrong. Thereal‐timeclockwas notsynced. Alllogtime stampsstartin theyear2000 Connectthemetertothe computerwithdataloggingoff. Thetimewillsynchronizein GasLab™. Nologsare presentonthe meterafterdata logging Themeterwas disconnectedwhilelogs werebeingdownloaded. Connectthemetertothe computeranddownloadlogs again. Thedisplayis Blueorshowing SensorMissing Themeter’sEEPROM hasbeencorrupted. Improperpowersupply. Pleaseemailourtechnical supportforfurtherassistance. Slowresponseor operation. Incorrectparametersor computerOS/software malfunction. ABCisadjustingthe zeropoint. Checktheparametersofthe meterandmakesurethespeed ofthecomputerisadequate. TurnoffABCorensuretheunitis exposedto400ppmairwhile datalogging. Themeterwas disturbedmechanically. Metermayneed calibration. Performacalibrationorsendthe metertoCO2Meterfor professionalcalibrationand recertification. CO2Readingsare inaccurate *FormoretroubleshootingtipsonGasLab®software,seeitsmanuallocatedat www.co2meter.com/pages/downloads. PAGE17 of19 CO2 + Oxygen Monitor Logger CO2Meter USBDriverInstallationInstructions ToinstalltheappropriateUSBportdriverscompatiblewithyourmeter,followthesesteps: 1. Gotohttp://www.ftdichip.com/Drivers/VCP.htmanddownloadthepackageappropriate fortheversionofWindowsinstalledinyourcomputer. 2. Movethefileyoudownloadedtoalocationyoucaneasilyaccess.Makesureyouhave administratorprivileges. 3. Extractthefilebyrightclickingonitandselectingextracthere. 4. Gotoyourcomputer’sDeviceManagerintheControlPanel. ForWindows8,presstheWindowskeyand'x'atthesametimetobringupthestart menuthenclickonDeviceManager. ForWindows7,openthestartmenuandtypeDeviceManagerinthesearchbar. 5. FindtheUnrecognizedUSBDeviceinthelist(itusually,butnotalways,hasayellow triangleicon). 6. RightclicktheUnrecognizedUSBDeviceitemandselectUpdateDriverSoftware. 7. SelectBrowseMyComputerandpointtothefolderwhereyouextractedthedriverfilesto (step#3). Thiswillinstallthenecessarydriverstoyourcomputerandallowyoutouseyourmeterwith GasLab™.Ifyouhavemultiplesensorsyoushouldonlyhavetoperformthisprocedureonce;the operatingsystemwillautomaticallyfindthedriverforalltheothersensors. Support Thequickestwaytoobtaintechnicalsupportisviaemail.Pleasesendallsupportinquiresto [email protected]. Pleaseincludeaclear,concisedefinitionoftheproblemandanyrelevanttroubleshooting informationorstepstakensofar,sowecanduplicatetheproblemandquicklyrespondtoyour inquiry. Warranty Thisunitcomeswitha1YEAR(warrantyperiod)limitedmanufacturer’swarranty,startingfrom thedatetheunitwasshippedtothebuyer. Duringthisperiodoftime,CO2Meter.comwarrantsourproductstobefreefromdefectsin materialsandworkmanshipwhenusedfortheirintendedpurposeandagreestorepairorreplace (atourdiscretion)anypartorproductthatfailsundernormaluse.Totakeadvantageofthis warranty,theproductmustbereturnedtoCO2Meter.comatyourexpense.If,afterexamination,we determinetheproductisdefective,wewillrepairorreplaceitatnoadditionalcosttoyou. Thiswarrantydoesnotcoveranyproductsthathavebeensubjectedtomisuse,neglect,accident, modificationsorrepairsbyyouorbyathirdparty.NoemployeeorresellerofCO2Meter.com’s productsmayalterthiswarrantyverballyorinwriting. PAGE18 of19 CO2 + Oxygen Monitor Logger CO2Meter Liability Allliabilitiesunderthisagreementshallbelimitedtotheactualcostoftheproductpaidto CO2Meter.com.InnoeventshallCO2Meter.combeliableforanyincidentalorconsequential damages,lostprofits,lossoftime,lostsalesorlossordamagetodata,injurytopersonorpersonal propertyoranyotherindirectdamagesastheresultofuseofourproducts. Returns Iftheproductfailsundernormaluseduringthewarrantyperiod,aRMA(ReturnMaterial Authorization)numbermustbeobtainedfromCO2Meter.com.Aftertheitemisreceived CO2Meter.comwillrepairorreplacetheitematourdiscretion. ToobtainaRMAnumber,callusatoremailusat(386)256‐[email protected] requestingaRMApleaseprovidereasonforreturnandoriginalordernumber. Iftheproductfailsundernormaluseinthefirst10daysofownership,atourdiscretionwewill emailyouapostage‐paidUPSlabeltoreturntheproductatourexpense. Ifwedeterminethattheproductfailedbecauseofimproperuse(waterdamage,dropping, tampering,electricaldamageetc.),orifitisbeyondthewarrantydate,wewillinformyouofthe costtofixorreplacetheproduct. ContactUs Weareheretohelp! Forinformationortechnicalsupport,pleasecontactus. [email protected] (386)256‐4910(TechnicalSupport) (386)872‐7665(Sales) www.co2meter.com Address: CO2Meter,Inc. 131BusinessCenter,A3 OrmondBeach,FL32174 USA PAGE19 of19
© Copyright 2024 Paperzz