Sanitary Ultrafiltration Spiral-Wound Element: ST (PES 10kDa) Synder Filtration’s Ultrafiltration Elements offer an STANDARD SERIES BENEFITS optimal combination of both flux and rejection in a comprehensive range of MWCO’s. Contact us today to learn more about our complete line of membrane products and services. Conforms to 3-A, FDA, and USDA sanitary standards Widest range of UF MWCO’s available Good resistance to pH and temperature High resistance to fouling Customizable dimensions for unique housings RECOMMENDED OPERATING PARAMETERS Operating Parameters Maximum Temperature pH Range @ Max Temperature pH Range @ Ambient Temperature Pressure 55°C (131°F) 3-9 2-10 PSI Bar Max Inlet Pressure 120 8.3 Min Outlet Pressure 10 0.7 Max Differential Pressure per Element 18 1.2 Max Permeate Backpressure 5 0.3 Note: Soft start on boost pumps required to minimize pressure/flow shocks to elements. Cleaning Parameters Maximum Temperature (Short term <30min) pH Range @ Max Temperature pH Range @ Ambient Temperature 50°C (122°F) COMMON APPLICATIONS Whey protein concentrate & isolate production Gelatin concentration Beverage clarification Enzyme concentration 2-11 1.8-11 CONTACT US Chlorine Norm ppm Max ppm Free Chlorine During Operation 0 <0.1 Chlorine During CIP at pH10.8-11.0 and 150 180 50°C Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH and temperature conditions listed above. Dairy Product Total Solids Limits Sweet Whey Max. T.S. Acid Whey Max. T.S. Skim Milk Max. T.S. Whole Milk Max. T.S. 31 15 15 14 15 Feed Spacer (in mils) 46 65 80 25 28 30 24 26 28 24 26 28 30 33 35 Note: Trials should be made to determine temperature and viscosity effects. 4941 Allison Parkway Vacaville, CA 95688, USA Phone: 1 (707) 451-6060 Fax: 1 (707) 451-6064 Email: [email protected] All inquiries will be responded to by a Synder employee personally within 24 hours. ELEMENT DIMENSIONS MEMBRANE AREA (SQ. FT.) Element Model No. Diameter (B) in Length (A) in P.W.T. ID Element 1.8” 1812F 2519 2540F 2540M* 3838 3838.75 3850 3938.75 4333 4335 4335.5 4336 4338 5838 6338 6324 6438 6424 7838 7824 8038 8040 8238 8240 8338 8340 9838 10338 1.8 2.5 2.5 2.5 3.8 3.8 3.8 4.0 4.3 4.3 4.3 4.3 4.3 5.8 6.3 6.3 6.4 6.4 7.8 7.8 8.0 8.0 8.2 8.2 8.3 8.3 9.8 10.3 12 19.25 40 38 38 38.75 50 38.75 33 35 35.5 36 38 38 38 24 38 24 38 24 38 40 38 40 38 40 38 38 0.63 0.63 0.63 0.75 0.83 0.83 0.83 0.63 0.83 0.83 0.83 0.83 0.83 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.8” 2.5” 3.8” 4.3” 5.8” 6.3” 6.4” 7.8” 8” 9.8” 10” 2.5” 3.8” 4.3” 5.8” 6.3” 6.4” 7.8” 8” 9.8” 10” Model No. 24 31 1812F 2519 2540F 2540M 3838 3838.75 3850 3938.75 4333 4335 4335.5 4336 4338 5838 6324 6338 6424 6438 7824 7838 8038 8040 8238 8240 8338 8340 9838 10338 N/A 15 34 35 85 86 100 102 99 105 107 108 115 210 150 246 157 258 242 396 414 414 441 441 450 450 N/A N/A 3.6 13 29 30 72 74 84 89 86 91 93 94 100 184 134 220 140 230 210 344 368 368 384 384 400 400 564 620 Feed Spacer (in mils) 46 65 N/A 10 22 23 58 59 70 69 66 71 72 73 77 147 107 176 112 184 166 273 287 287 302 302 311 311 440 492 N/A N/A N/A N/A 46 47 52 53 53 56 57 58 62 114 83 136 83 136 132 216 225 225 238 238 245 245 351 386 80 N/A N/A N/A N/A 38 39 46 47 44 47 48 49 52 96 70 115 74 122 110 180 189 189 201 201 207 207 296 326 *1” permeate tube extensions (0.75” OD) TECHNICAL NOTES RECOMMENDED ELEMENT CROSS FLOW RATE Element 1.8” 2.5” 3.8” 4.3” 5.8” 6.3” 8” 10” Feed Spacer (in mils) 46 65 24 31 m³/hr 1 1 1 2 80 2 gpm m³/hr gpm m³/hr gpm m³/hr gpm m³/hr gpm m³/hr gpm m³/hr gpm m³/hr 4 2 9 5 22 6 29 12 51 15 65 21 94 42 5 2 10 6 25 7 32 13 59 17 74 24 107 48 6 3 11 7 29 9 38 16 69 20 88 29 128 57 7 3 12 8 33 10 44 18 78 22 99 33 143 64 7 3 13 8 35 10 46 19 83 24 105 35 154 68 gpm 184 213 250 283 299 The recommended cross flow rate will be subject to differential pressure limitations and specific applications. Please consult Synder Filtration if additional information is needed. For element sizes not listed, please call or email Synder Filtration for details. We can design an element to fit your exact needs – just specify the element outer diameter (OD) or vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are also available with or without a controlled bypass tail. Additional feed spacers are also available. Trials should be conducted to determine optimal application conditions. ELEMENT DESCRIPTIONS Model No. OD (in.) 1812F 2519 2540F 2540M* 3838 3838.75 3850 3938.75 4333 4335 4335.5 4336 4338 5838 6338 6324 6438 6424 7838 7824 8038 8040 8238 8240 8338 8340 9838 10338 1.8 2.5 2.5 2.5 3.8 3.8 3.8 4.0 4.3 4.3 4.3 4.3 4.3 5.8 6.3 6.3 6.4 6.4 7.8 7.8 8.0 8.0 8.2 8.2 8.3 8.3 9.8 10.3 L (in.) 12 19.25 40 38 38 38.75 50 38.75 33 35 35.5 36 38 38 38 24 38 24 38 24 38 40 38 40 38 40 38 38 ID* (in.) 0.63 0.63 0.63 0.75 0.83 0.83 0.83 0.63 0.83 0.83 0.83 0.83 0.83 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 Weight (lb) Weight (kg) 1.0 2 4 4 10 10 13 10 11 11 11 11 12 15 16 17 29 18 40 26 38 39 38 40 40 40 42 50 0.5 0.9 1.8 1.8 4.5 4.5 5.9 4.5 5.0 5.2 5.2 5.2 5.4 7 7 7.7 13.2 8.2 18.2 11.8 17.2 17.7 17.2 18 18 18 19.1 22.7 *1” permeate tube extensions (0.75” OD) NOTE: Different diameters are available. Please specify you requirements when ordering. Specifications are subject to change without notice.
© Copyright 2023 Paperzz