Sanitary Ultrafiltration Spiral

Sanitary Ultrafiltration Spiral-Wound Element: ST (PES 10kDa)
Synder Filtration’s Ultrafiltration Elements offer an
STANDARD SERIES BENEFITS
optimal combination of both flux and rejection in a

comprehensive range of MWCO’s. Contact us today




to learn more about our complete line of membrane
products and services.
Conforms to 3-A, FDA, and USDA sanitary
standards
Widest range of UF MWCO’s available
Good resistance to pH and temperature
High resistance to fouling
Customizable dimensions for unique housings
RECOMMENDED OPERATING PARAMETERS
Operating Parameters
Maximum Temperature
pH Range @ Max Temperature
pH Range @ Ambient Temperature
Pressure
55°C (131°F)
3-9
2-10
PSI
Bar
Max Inlet Pressure
120
8.3
Min Outlet Pressure
10
0.7
Max Differential Pressure per Element
18
1.2
Max Permeate Backpressure
5
0.3
Note: Soft start on boost pumps required to minimize pressure/flow shocks to
elements.
Cleaning Parameters
Maximum Temperature (Short term
<30min)
pH Range @ Max Temperature
pH Range @ Ambient Temperature
50°C (122°F)
COMMON APPLICATIONS
 Whey protein concentrate & isolate
production
 Gelatin concentration
 Beverage clarification
 Enzyme concentration
2-11
1.8-11
CONTACT US
Chlorine
Norm ppm
Max ppm
Free Chlorine During Operation
0
<0.1
Chlorine During CIP at pH10.8-11.0 and
150
180
50°C
Note: Maximum chlorine exposure for all elements is 30 minutes per day at pH
and temperature conditions listed above.
Dairy Product Total Solids Limits
Sweet Whey Max. T.S.
Acid Whey Max. T.S.
Skim Milk Max. T.S.
Whole Milk Max. T.S.
31
15
15
14
15
Feed Spacer (in mils)
46
65
80
25
28
30
24
26
28
24
26
28
30
33
35
Note: Trials should be made to determine temperature and viscosity effects.
4941 Allison Parkway
Vacaville, CA 95688, USA
Phone: 1 (707) 451-6060
Fax: 1 (707) 451-6064
Email:
[email protected]
All inquiries will be responded to
by a Synder employee
personally within 24 hours.
ELEMENT DIMENSIONS
MEMBRANE AREA (SQ. FT.)
Element
Model No.
Diameter (B) in
Length (A) in
P.W.T. ID
Element
1.8”
1812F
2519
2540F
2540M*
3838
3838.75
3850
3938.75
4333
4335
4335.5
4336
4338
5838
6338
6324
6438
6424
7838
7824
8038
8040
8238
8240
8338
8340
9838
10338
1.8
2.5
2.5
2.5
3.8
3.8
3.8
4.0
4.3
4.3
4.3
4.3
4.3
5.8
6.3
6.3
6.4
6.4
7.8
7.8
8.0
8.0
8.2
8.2
8.3
8.3
9.8
10.3
12
19.25
40
38
38
38.75
50
38.75
33
35
35.5
36
38
38
38
24
38
24
38
24
38
40
38
40
38
40
38
38
0.63
0.63
0.63
0.75
0.83
0.83
0.83
0.63
0.83
0.83
0.83
0.83
0.83
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.8”
2.5”
3.8”
4.3”
5.8”
6.3”
6.4”
7.8”
8”
9.8”
10”
2.5”
3.8”
4.3”
5.8”
6.3”
6.4”
7.8”
8”
9.8”
10”
Model
No.
24
31
1812F
2519
2540F
2540M
3838
3838.75
3850
3938.75
4333
4335
4335.5
4336
4338
5838
6324
6338
6424
6438
7824
7838
8038
8040
8238
8240
8338
8340
9838
10338
N/A
15
34
35
85
86
100
102
99
105
107
108
115
210
150
246
157
258
242
396
414
414
441
441
450
450
N/A
N/A
3.6
13
29
30
72
74
84
89
86
91
93
94
100
184
134
220
140
230
210
344
368
368
384
384
400
400
564
620
Feed Spacer (in mils)
46
65
N/A
10
22
23
58
59
70
69
66
71
72
73
77
147
107
176
112
184
166
273
287
287
302
302
311
311
440
492
N/A
N/A
N/A
N/A
46
47
52
53
53
56
57
58
62
114
83
136
83
136
132
216
225
225
238
238
245
245
351
386
80
N/A
N/A
N/A
N/A
38
39
46
47
44
47
48
49
52
96
70
115
74
122
110
180
189
189
201
201
207
207
296
326
*1” permeate tube extensions (0.75” OD)
TECHNICAL NOTES
RECOMMENDED ELEMENT CROSS FLOW RATE
Element
1.8”
2.5”
3.8”
4.3”
5.8”
6.3”
8”
10”
Feed Spacer (in mils)
46
65
24
31
m³/hr
1
1
1
2
80
2
gpm
m³/hr
gpm
m³/hr
gpm
m³/hr
gpm
m³/hr
gpm
m³/hr
gpm
m³/hr
gpm
m³/hr
4
2
9
5
22
6
29
12
51
15
65
21
94
42
5
2
10
6
25
7
32
13
59
17
74
24
107
48
6
3
11
7
29
9
38
16
69
20
88
29
128
57
7
3
12
8
33
10
44
18
78
22
99
33
143
64
7
3
13
8
35
10
46
19
83
24
105
35
154
68
gpm
184
213
250
283
299
The recommended cross flow rate will be subject to differential pressure limitations
and specific applications. Please consult Synder Filtration if additional information is
needed.
For element sizes not listed, please call or email Synder Filtration for details. We can design
an element to fit your exact needs – just specify the element outer diameter (OD) or
vessel/housing inner diameter (ID), element inner diameter (ID), and length. Elements are
also available with or without a controlled bypass tail. Additional feed spacers are also
available. Trials should be conducted to determine optimal application conditions.
ELEMENT DESCRIPTIONS
Model No.
OD (in.)
1812F
2519
2540F
2540M*
3838
3838.75
3850
3938.75
4333
4335
4335.5
4336
4338
5838
6338
6324
6438
6424
7838
7824
8038
8040
8238
8240
8338
8340
9838
10338
1.8
2.5
2.5
2.5
3.8
3.8
3.8
4.0
4.3
4.3
4.3
4.3
4.3
5.8
6.3
6.3
6.4
6.4
7.8
7.8
8.0
8.0
8.2
8.2
8.3
8.3
9.8
10.3
L (in.)
12
19.25
40
38
38
38.75
50
38.75
33
35
35.5
36
38
38
38
24
38
24
38
24
38
40
38
40
38
40
38
38
ID* (in.)
0.63
0.63
0.63
0.75
0.83
0.83
0.83
0.63
0.83
0.83
0.83
0.83
0.83
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
Weight (lb)
Weight (kg)
1.0
2
4
4
10
10
13
10
11
11
11
11
12
15
16
17
29
18
40
26
38
39
38
40
40
40
42
50
0.5
0.9
1.8
1.8
4.5
4.5
5.9
4.5
5.0
5.2
5.2
5.2
5.4
7
7
7.7
13.2
8.2
18.2
11.8
17.2
17.7
17.2
18
18
18
19.1
22.7
*1” permeate tube extensions (0.75” OD)
NOTE: Different diameters are available. Please specify you requirements when ordering.
Specifications are subject to change without notice.