City of Moline PLAN COMMISSION Wednesday, April 12, 2017 4:00 p.m. Council Chambers, 619 16th Street AGENDA 1. Call to order 2. Reading and approval of minutes from March 22, 2017 3. Public hearings a. PC 17-02 – Public hearing and request from Hemal Patel, Moline Hotel Investments, LLC for a text amendment to Table 35-3301.1 of the Moline Zoning and Land Development Code to increase the maximum building height in the B-4 zoning district from 45 feet to 70 feet. 4. Other business 5. Review of upcoming meetings 6. Public comment 7. Adjournment Any person with disabilities who wishes to attend the meeting who requires a special accommodation or any other person requiring a special accommodation in attending the meeting should notify Anamaria Vera, Department of Planning & Development, 524-2053. MEMORANDUM TO: FROM: SUBJECT: DATE: Planning & Development th 619 – 16 Street Moline, Illinois 61265 309-524-2036 309-524-2031 fax www.moline.il.us Plan Commission Shawn Christ PC 17-02 – Public hearing and request from Hemal Patel, Moline Hotel Investments, LLC for a text amendment to Table 35-3301.1 of the Moline Zoning and Land Development Code to increase the maximum building height in the B-4 zoning district from 45 feet to 70 feet. April 7, 2017 I’ve attached an application and redlined draft of a proposed amendment to the Zoning and Land Development Code. Moline Hotel Investments, LLC has purchased the former Holiday Inn site near the QC Airport at th 6902 27 Street. They are working to redevelop the site with at least one new hotel and have noticed an issue with Moline’s maximum allowable height in the B-4 zoning district. They have submitted an application to amend the ordinance with a claim that a 3-story hotel with roofmounted HVAC units may exceed the 45-foot height limit. Planning & Administration 524-2030 The proposal is to amend Table 35-3301.1 by increasing the allowable building height in the B-4 zoning district from 45 feet to 70 feet. As part of this amendment, staff will propose an additional front and rear setback for buildings over 50 feet. Staff will also propose an additional amendment to Sec. 35-3108 to create a maximum height exception for generators, HVAC, commucations, utilities, and related equipment. Community Development 524-2040 Section 35-2203(c) lists the approval criteria for zoning code amendments. Most of these criteria are specific to rezoning requests, however, the following criteria may be evaluated for this proposed text amendment: Divisions Economic Development 524-2036 Land Development 524-2050 • Whether the existing text was in error at the time of adoption. The B-4 Highway/Intensive Business district is intended to permit intensive, general commercial development adjacent to expressways and major thoroughfares. Although the district is commonly defined by large 1 or 2story commercial development such as big box stores or shopping centers, the district’s building height limit did not seem to anticipate vertical development such as hotels or corporate offices which could exceed 3 stories in height. • Whether the proposal is in conformance with and in furtherance of the implementation of the goals and policies of the Comprehensive Plan, other adopted plans, and the policies, intents, and requirements of the Zoning Code and other City regulations and guidelines. The proposal conforms and is consistent with all adopted plans and policies. • Whether there is a need in the community for the proposal. Offices, apartment buildings, and hotels are allowed to build up to 4 stories or 70 feet in height with wood frame construction and other provisions such as a fire protection system. There is demand for this type of development in areas outside of downtown and it seems reasonable to reconsider the B-4 height standard rather than rely on the PUD process for flexibility in a development. Staff recommends Plan Commission support of the proposed amendment. Attachment: Redlined amendment sheet, application form and attachments Table 35-3301.1. Non-Residential/Resource Districts Principal and Major Accessory Structure Bulk Standards Minimum Yard Setbacks(2) (ft) Side Minimum Lot Dimensions Maximum Building Height (ft/stories Maximum Building Coverage (4) (%) Maximum Building Size (3) (sq ft/FAR) Minimum Landscape Surface Ratio 50 20,000 0.25 20 35 70 10,000 0.20 0/20 0 35 100 10,000 0.00 0/10 0 0 None 100 5.0 FAR 0.00 0/10 0 0 10 45 60 100,000 0.10 0/20 20 0 0 20 4570 50 500,000 0.20 0/20 20 50 15 30 20 45 50 250,000 0.30 40 50 20 20 15 30 20 45 60 250,000 0.10 0/10 50 20 20+ 15 30 20+ 75 70 2.0 FAR 0.10 0/10 Zoning District Lot Area (sq ft) Width (feet) Street Front (feet)(1) Front(8) Least O-1(6) 5,000 50 20 15 0 15 15 35/2 1/2 (6) 5,000 50 20 20 0 0 10 NC(6) 5,000 50 20 0 0 0 B-2(6) 5,000 50 20 0 0 B-3 (6) 5,000 50 20 20 B-4 (7) 20,000 50 20 ORT 20,000 50 I-1 20,000 20,000 B-1 I-2 (7) Minimum On-Site Building Separation(5) (ft) Sum Rear Footnotes: (1) The requirements may be waived if the City engineer instead approves, and the applicant records, an irrevocable access easement. (2) Yards adjoining Residential Districts shall have minimum setbacks equal to the adjoining Residential District. Required bufferyards (see Sec. 35-5207) may also require larger setbacks. (3) Maximum size of building permitted by right. Larger buildings require approval of a special use permit (see Sec. 35-2206). (4) Combined coverage of all principal and major accessory structures. (5) Where “0” and another dimension are indicated, buildings must be attached or have the minimum separation indicated. (6) For residential development, refer to the R-6 District standards. (7) For buildings higher than 50 feet, the minimum front yard setback shall be 40% of building height and the minimum rear yard setback shall be 30 feet. (8) The required front yard setbacks apply to all sides of a corner lot that have street frontage (See Section 35-3108 for exceptions). (Ord. No. 3008-2009; Table 35-3301.1 amended by inserting footnote (8) to Minimum Yard Setbacks, “Front”; 03/24/09) Formatted: Superscript, Highlight Formatted: Highlight SEC. 35-3108. PRINCIPLE AND MAJOR ACCESSORY STRUCTURE BULK STANDARD EXCEPTIONS. (a) MINIMUM FRONT YARD SETBACK. The following Minimum Setbacks shall be applied to lots of record created prior to 1991 that do not meet all of the Bulk Standards for Minimum Lot Dimension contained in Table 35-3201.1 or Table 35-3301.1: (1) Minimum corner lot side street setback: 10 feet. (2) Minimum reverse corner lot side street setback: 50% of the minimum front yard setback of the lot to the rear or 15 feet, whichever is less. MAXIMUM HEIGHT EXCEPTIONS. The Maximum Height Requirements shall not apply to (b) the following. However, if in the opinion of the building official such structures would adversely affect abutting or adjacent properties, such greater height shall not be authorized except by approval of a variance by the zoning hearing officer as per Sec. 35-2207 of this Code. (1) Church spires, belfries, cupolas and domes, monuments, water Towers, fire and hose Towers, masts and aerials. (2) Indoor institutional uses such as churches, schools and other permitted public and semi-public buildings not to exceed six 6 stories or 75 feet, provided that for each foot over the maximum height otherwise permitted in the district, the minimum side and rear yard setbacks shall be increased in width and depth by an additional foot. (3) Barns, silos or other farm buildings provided they are not less than 50 feet from every lot line. (4) Bulkheads, conveyors, derricks, elevators, penthouses, monitors, scenery lofts, cooling Towers, grain elevators, gas holders, or other structures where the permitted industrial use requires a greater height. (5) Generators, heating, cooling, ventilation, communications, utility and related equipment provided that such equipment meets all other applicable standards in this Code including but not limited to screening, visibility, height, or placement. (Ord. No. 3008-2009; Sec. 35-3108(a) repealed; new Sec. 35-3108(a) enacted; 03/24/09)
© Copyright 2025 Paperzz