TECHNICAL MANU AL MANUAL ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers • Refer to Service Manual RS6200006 for installation, operation & troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2012-2014 Goodman Company, L.P. RT6121003r7 January 2014 PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. A R U F 18 EXPANSION DEVICE: F: Flowrater T: TXV (Expansion Device) PRODUCT TYPE: A: Air Handler CABINET FINISH: P: Painted U: Unpainted B 1 4 A A MINOR REVISION* CABINET WIDTH B: 17.5" C: 21" D: 24.5" MAJOR REVISION* REFRIGERANT CHARGE: 4: R-410A only ELECTRICAL: 1: 208-230V/1ph/60Hz APPLICATION: R: Multi-Position PSC Motor S: Energy Efficient Motor NOMINAL CAPACITY RANGE 18: 1-1/2 Tons 24: 2 Tons 30: 2-1/2 Tons 36: 3 Tons 42: 3-1/2 Tons 48: 4 Tons 49: 4 Tons 59: 5 Tons 60: 5 Tons All Airhandlers use DIRECT DRIVE MOTORS. Power supply is AC 208-230v, 60 hz, 1 phase. WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. WARNING 2 Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician", at a minimum, as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. WARNING PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. ARPT18B14** ARPT24B14** ARPT30B14** ARPT36C14** ARPT36D14** ARPT42D14** ARPT48D14** ARPT60D14** WARNING ASUF29B14** ASUF39C14** ASUF49C14** ASUF59D14** ASPT42D14** ASPT48D14** ASPT60D14** ARUF18B14** ARUF24B14** ARUF30B14** ARUF30C14** ARUF36C14** ARUF42C14** ARUF48D14** ARUF60D14** ASPT24B14** ASPT30C14** ASPT36C14** ASPT42C14** ASPT48C14** The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. When installing or servicing this equipment, safety clothing, including hand and eye protection, is strongly advised. If installing this equipment in an area that has special safety requirements (hard hats etc.), observe these requirements. To protect the unit when brazing close to the painted surfaces, the use of a quenching cloth is strongly advised to prevent scorching or marring of the equipment finish. The unit MUST have an uninterrupted, unbroken electrical ground to minimize the possibility of personal injury if an electrical fault should occur. The electrical ground circuit may consist of an appropriately sized electrical wire connecting the ground lug in the unit control box to the building electrical service panel. Other methods of grounding are permitted if performed in accordance with the “National Electric Code” (NEC)/“American National Standards Institute” (ANSI)/“National Fire Protection Association” (NFPA) 70 and local/state codes. In Canada, electrical grounding is to be in accordance with the Canadian Electric Code CSA C22.1. Failure to observe this warning can result in electrical shock that can cause personal injury or death. WARNING WARNING WARNING WARNING 3 PRODUCT DESIGN If this appliance is installed in an enclosed area such as a garage or utility room with any carbon monoxide (CO) producing appliance (i.e. automobile, furnace, water-heaters, etc.), ensure the area is properly ventilated. WARNING WARNING HIGH VOLTAGE Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Heating and cooling equipment located in garages, which may generate a glow, spark or flame capable of igniting flammable vapors, must be installed with the ignition source at least 18"[46cm] above the floor level. When more than one appliance is installed in a building it shall be permanently identified as to the area or space serviced by the equipment. When this product is installed in the downflow installation in an unconditioned space, remove the horizontal drain pan and install the following insulation kit. MODEL LIST FOR DOWNFLOW KITS DFK-B Downflow Kit DFK-C Downflow Kit DFK-D Downflow Kit AIR HANDLERS ARUF18B14** ARUF30C14** ARUF48D14** See Air Handler Specification Sheet for Proper Combinations. ARUF24B14** ARUF36C14** ARUF60D14** ARUF30B14** ARUF42C14** ARPT36D14** ARPT18B14** ARPT36C14** ARPT42D14** ARPT24B14** ASUF39C14** ARPT48D14** ARPT30B14** ASUF49C14** ARPT60D14** ASUF29B14** ASPT30C14** ASUF59D14** ASPT24B14** ASPT36C14** ASPT42D14** ASPT42C14** ASPT48D14** ASPT48C14** ASPT60D14** ALL AIR HANDLERS USE DIRECT DRIVE MOTORS. POWER SUPPLY IS 208-230 V, 60 HZ, 1 PHASE. Installation Before installing this appliance insure that it is properly sized and adequate power is available. This appliance can be installed in the vertical or right horizontal position without modification. The horizontal left and downflow positions require product modification. This product is designed for zero inches (0 inches) clearance; however, adequate access for service or replacement must be considered without removing permanent structure. This unit can be installed on a platform when deemed necessary. In an attic installation a secondary drain pan must be provided by the installer and placed under the entire unit with a separate drain line properly sloped and terminated in an area visible to the owner. This secondary drain pan is required in the event that there is a leak or main drain blockage. Closed cell insulation should be applied to the drain lines in unconditioned spaces where sweating may occur. Appliances installed in garages, warehouses or other areas where they may be subjected to mechanical damage must be suitably guarded against such damage by installing behind protective barriers, being elevated or located out of the normal path of vehicles. When installed on a base, the base must also be protected by similar means. 4 This kit is used to prevent sweating on the vertical drain pan. ARPT, ARUF, ASPT and ASUF air handlers are multi-position, multi-speed with direct drive motors. ARPT and ARUF are available in 1 1/2 to 5 ton sizes with optional 3 kW to 25kW electric heat kits available for field installation. (See note below.) ASPT air handlers are available in 2, 3, 4 and 5 ton sizes with optional 3 kW to 25kW electric heat kits available for field installation. (See following note.) NOTE: Factory-sealed to achieve a 2% or less leakage rate at 1.0" water gauge external duct static pressure. Complies with the Factory-sealed Air Handling Credit as listed in the 2001 Florida Building Code, Chapter 13, Section 610.2.A.2.1. HKS HEAT KITS ARPT**14** ARPT Heat Kit Applications Type / model 18B14-A* 24B14-A* 30B14-A* 36C14-A* 36D14-A* 42D14-A* 48D14-A* 60D14-A* HKSX03XC* X X X X X X X X HKSX05XC* X X X X X X X X HKSX06XC* X X X X X X X X HKSX08XC* X X X X X X X X HKSX10XC* X X X X X X X X HKSC05XC* X X X X X X X X HKSC08XC* X X X X X X X X HKSC10XC* X X X X X X X X HKSC15XA* X X X X X X HKSC15XB* X X X X X X HKSC15XF* X X X X X HKSC19CA* X HKSC19CB* X HKSC20DA* X X X X HKSC20DB* X X X X X X HKSC20XF* HKSC25DC* * Revi sion l evel that may or may not be desi gnated X X X X X Re fer to the minimum air flow requirements for each of the heat k it s. 5 HKS HEAT KITS ARUF**14** ARUF Heat Kit Applications Type / model 18B14-A* 24B14-B* 30B14-A* 3 0C14-B* 36C14-B* 42C14-A* 48 D14-A* 60D14-A* HKSX03XC* X X X X X X X X HKSX05XC* X X X X X X X X HKSX06XC* X X X X X X X X HKSX08XC* X X X X X X X X HKSX10XC* X X X X X X X X HKSC05XC* X X X X X X X X HKSC08XC* X X X X X X X X HKSC10XC* X X X X X X X X HKSC15XA* X X X X X X HKSC15XB* X X X X X X HKSC15XF* X X X X X HKSC19CA* X X X HKSC19CB* X X X X X HKSC20DA* HKSC20DB* HKSC20XF* X X HKSC25DC* * Revision level that may or may not be designated X X X X X X Refer to the minimum airflow requirements for each of the heat kits. HEATER (kW) *ARUF ARPT 3 5 6 8 10 18 715 715 715 715 950 24 715 715 715 715 950 30B 715 15 19 20 25 715 715 715 875 875 30C 1170 1170 1170 1170 1345 1345 36 1170 1170 1170 1170 1345 1345 42 1170 1170 1170 1170 1345 1345 48 1590 1590 1590 1590 1715 1715 1715 60 1590 1590 1590 1590 1715 1715 1715 Minimum CFM required for Heater Kits 6 X X ASPT**14** HKS HEAT KITS AS PT H e at K it A p p li cat io n s Ty pe / m o del 2 4 B 1 4 -A * 3 6 C 1 4 -A * 4 2 C 1 4 -A * 4 8 C 1 4 -A * 4 8 D 1 4 -A * 6 0 D 1 4 -A * H KS X0 3 XC * X X X X X X H KS X0 5 XC * X X X X X X H KS X0 6 XC * X X X X X X H KS X0 8 XC * X X X X X X H KS X1 0 XC * X X X X X X H KS C 0 5 XC * X X X X X X H KS C 0 8 XC * X X X X X X H KS C 1 0 XC * X H KS C 1 5 XA * X X X X X X X X X X H KS C 1 5 XB* X X X X X H KS C 1 5 XF * X X X X X H KS C 2 0 D A * X X H KS C 2 0 D B* X X X X X X H KS C 1 9 C A * X X X H KS C 1 9 C B* X X X H KS C 2 0 XF * X X X H KS C 2 5 D C * * R e v is i o n l e v e l t h a t m a y o r m a y n o t b e d e s ig n a t e d . R e f e r t o t h e m in im u m a ir f lo w r e q u ir e m e n t s f o r e a c h o f t h e h e a t k i t s . Heater (KW) 3 5 6 ASPT24B14* 715 715 715 ASPT30C14* 730 715 715 ASPT36C14* NR 1170 1170 ASPT42C14* NR 1170 1170 ASPT48C14* NR 1170 1170 ASPT42D14* NR 1590 1590 ASPT48D14* NR 1590 1590 ASPT60D14* NR 1590 1590 MINIMUM CFM REQUIRED FOR HEATER KITS 8 715 715 1170 1170 1170 1590 1590 1590 10 875 950 1170 1170 1170 1590 1590 1590 15 NR NR 1345 1345 1345 1715 1715 1715 19 NR NR 1345 1345 1345 NR NR NR 20 NR NR 1345 1345 1345 1715 1715 1715 25 NR NR NR NR NR NR 1715 1715 7 HKS HEAT KITS ASUF**14** ASUF Heat Kit Applications Type / model 29B14-A* 39C14-A* 49C14-A* 59D14-A* HKSX03XC* X X X X HKSX05XC* X X X X HKSX06XC* X X X X HKSX08XC* X X X X HKSX10XC* X X X X HKSC05XC* X X X X HKSC08XC* X X X X HKSC10XC* X X X X HKSC15XA* X X X HKSC15XB* X X X HKSC15XF* X X X HKSC19CA* X X HKSC19CB* X X HKSC20DA* X HKSC20DB* X HKSC20XF* X X X HKSC25DC* X * Revision level that may or may not be designated. Refer to the minimum airflow requirements for each of the heat kits. HEATER (kW) ASUF 3 5 6 8 10 715 715 715 715 875 39 1170 1170 1170 49 1170 1170 1170 59 1590 1590 1590 29 Minimum CFM required for Heater Kits 8 15 19 1170 1345 1345 1170 1345 1345 1590 1715 20 25 1715 1715 PRODUCT DIMENSIONS ARPT**14**/ARUF**14**/ASPT**14**/ASUF**14** 9 PRODUCT DIMENSIONS ARPT**14**/ARUF**14** Model A B C D E F G H ARPT18B14* 45 16 3/8 17 1/2 18 15 14 3/16 8 13/16 11 15/16 ARPT24B14* 45 16 3/8 17 1/2 18 15 14 3/16 8 13/16 11 15/16 ARPT30B14* 45 16 1/8 17 1/2 18 15 14 3/16 8 13/16 11 15/16 ARPT36C14* 49 19 15/16 21 20 17 17 11/16 10 1/2 12 3/8 ARPT36D14* 58 23 5/16 24 1/2 28 3/16 25 3/16 21 3/16 12 5/16 12 3/8 ARPT42D14* 58 23 5/16 24 1/2 28 3/16 25 3/16 21 3/16 12 5/16 12 3/8 ARPT48D14* 58 23 5/16 24 1/2 28 3/16 25 3/16 21 3/16 12 5/16 12 3/8 ARPT60D14* 58 23 5/16 24 1/2 28 3/16 25 3/16 21 3/16 12 5/16 12 3/8 Model A B C D E F G H ARUF18B14* 45 16 3 /8 17 1 /2 18 15 14 3/16 8 13/16 11 15 /16 ARUF24B14* 45 16 /8 1 18 15 14 /16 3 8 /16 ARUF30B14* 45 ARUF30C14* Dimensions are in inches. 3 17 /2 16 /8 3 17 /2 1 18 15 14 /16 3 8 /16 49 19 15 /16 21 20 17 17 11 /16 10 1 /2 ARUF36C14* 49 19 15 /16 21 20 17 17 11 /16 10 /2 12 /8 ARUF42C14* 49 19 15 /16 21 20 17 17 11 /16 10 1 /2 12 3 /8 ARUF48D14* 58 23 5/ 16 24 1 /2 28 3/16 25 3/16 21 3/16 12 5/16 12 3 /8 ARUF60D14* 58 23 5/ 16 24 1 /2 28 3/16 25 3/16 21 3/16 12 5/16 12 3 /8 Dimensions are in inches. 10 13 11 15 /16 13 11 15 /16 1 12 3 /8 3 PRODUCT DIMENSIONS Model ASPT24B14* ASPT30C14* ASPT36C14* ASPT42C14* ASPT48C14* ASPT42D14* ASPT48D14* ASPT60D14* A 45 49 49 49 49 58 58 58 B 16⅜ 19¹⁵⁄₁₆ 19¹⁵⁄₁₆ 19¹⁵⁄₁₆ 19¹⁵⁄₁₆ 23⁵⁄₁₆ 23⁵⁄₁₆ 23⁵⁄₁₆ ASPT**14**/ASUF**14** C 17½ 21 21 21 21 24½ 24½ 24½ D 18 20 20 20 20 28³⁄₁₆ 28³⁄₁₆ 28³⁄₁₆ E 15 17 17 17 17 25³⁄₁₆ 25³⁄₁₆ 25³⁄₁₆ F 14³⁄₁₆ 17¹¹⁄₁₆ 17¹¹⁄₁₆ 17¹¹⁄₁₆ 17¹¹⁄₁₆ 21³⁄₁₆ 21³⁄₁₆ 21³⁄₁₆ G 8¹³⁄₁₆ 10½ 10½ 10½ 10½ 12⁵⁄₁₆ 12⁵⁄₁₆ 12⁵⁄₁₆ H 11¹⁵⁄₁₆ 12⅜ 12⅜ 12⅜ 12⅜ 12⅜ 12⅜ 12⅜ Dimensions are in inches. Model A B C D E F G H ASUF29B14* 45 16 3/8 17 1/2 18 15 14 3/16 8 13/16 11 15/16 ASUF39C14* 49 19 15/16 21 20 17 17 11/16 10 1/2 12 3/8 ASUF49C14* 49 19 15/16 21 20 17 17 11/16 10 1/2 12 3/8 ASUF59D14* 58 23 5/16 24 1/2 28 3/16 25 3/16 21 3/6 12 5/16 12 3/8 Dimensions are in inches. 11 PRODUCT SPECIFICATIONS ARPT**14** ARPT 18B14* ARPT 24B14* ARPT 30B14* ARPT 36C14* ARPT 36D14* ARPT 42D14* ARPT 48D14* ARPT 60D14* 18,000 24,000 30,000 36,000 36,000 42,000 48,000 60,000 1065 825 560 1065 825 560 1020 775 565 1445 1300 1175 1705 1485 1140 1810 1555 1350 1845 1495 1280 2080 1865 1505 9½" 9½" 9½" 10⅝" 10⅝" 10⅝" 11 /16" 15 11 /16" Width 6" 6" 6" 8" 10⅝" 10⅝" 10⅝" 10⅝" Coil Drain Connect FPT ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ⅞" ⅞" ⅞" ⅞" ⅞" Nominal Ratings Cooling (Btu/h) Airflow Rate CFM * High Med Low Blower Diameter 15 Refrigerant Line Connection Size Electrical Data Voltage Min Circuit Ampacity Max. Overcurrent Device (amps) Min. / Max VAC Blower Motor FLA/ HP Ship Weight (lbs) *Airflow rate @.3 static 12 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 3/3 3/3 3/3 4/4 4/4 5/5 5/5 6/6 15 / 15 15 / 15 15 / 15 15 / 15 15 / 15 15 / 15 15 / 15 15 / 15 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 1.9 / ⅓ 1.9 / ⅓ 1.9 / ⅓ 3.1 / ⅓ 3.0 / ½ 3.5 / ½ 3.5/ ½ 4.6 / ¾ 100 100 105 118 155 155 167 167 PRODUCT SPECIFICATIONS ARUF**14** ARUF 18B14* ARUF 24B14* ARUF 30B14* ARUF 30C14* ARUF 36C14* ARUF 42C14* ARUF 48D14* ARUF 60D14* 18,000 24,000 30,000 36,000 36,000 42,000 48,000 60,000 1045 835 565 1045 835 565 1020 775 565 1385 1235 980 1385 1235 980 1465 1290 1000 1810 1555 1350 2125 1885 1455 9½" 9½" 9½" 10⅝" 10⅝" 10⅝" 10⅝" 1115/16" Width 6" 6" 6" 8" 8" 8" 10⅝" 10⅝" Coil Drain Connect FPT ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ¾" ¾" ⅞" ⅞" ⅞" 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 3/3 3/3 3/3 4/4 4/4 4/4 5/5 6/6 15 / 15 15 / 15 15 / 15 15 / 15 15 / 15 15 / 15 15 / 15 15 / 15 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 1.9 / ⅓ 1.9 / ⅓ 1.9 / ⅓ 3.0 / ⅓ 3.0 / ⅓ 3.1 / ⅓ 3.5 / ½ 4.6 / ¾ 98 98 103 115 115 117 154 154 Nominal Ratings Cooling (Btu/h) Airflow rate CFM* High Med Low Blower Diameter Refrigerant Line Connection Size Electrical Data Voltage Min Circuit Ampacity Max. Overcurrent Device (amps) Min. / Max VAC Blower Motor FLA/ HP Ship Weight (lbs) *Airflow rate @.3 static 13 ASPT**14** PRODUCT SPECIFICATIONS Nominal Ratings Cooling (Btu/h) Airflow Rate CFM * T1 T2 T3 T4 T5 Blower Diameter Width Coil Drain Connect FPT Refrigerant Line Connection Size Liquid Suction Electrical Data Voltage Min Circuit Ampacity Max. Overcurrent Device Min. / Max VAC Blower Motor FLA/ HP Ship Weight (lbs) ASPT 24B14* ASPT 30C14* ASPT 36C14* ASPT 42C14* ASPT 48C14* ASPT 42D14* ASPT 48D14* ASPT 60D14* 24,000 30,000 36,000 36,000 42,000 42,000 48,000 60,000 520 600 660 775 975 540 625 720 810 1,400 890 995 1090 1205 1425 865 980 1,070 1,190 1,520 1275 1400 1500 1585 1680 1110 1250 1355 1440 1780 1250 1400 1515 1635 1825 1400 1600 1745 1995 2160 9½" 6" ¾" 10⅝" 8" ¾" 10⅝" 8" ¾" 10⅝" 10⅝" ¾" 10⅝" 10⅝" ¾" 10⅝" 10⅝" ¾" 10⅝" 10⅝" ¾" 11¹⁵⁄₁₆" 10⅝" ¾" ⅜" ¾" ⅜" ⅞" ⅜" ⅞" ⅜" ⅞" ⅜" ⅞" ⅜" ⅞" ⅜" ⅞" ⅜" ⅞" 208 / 230 3/3 15 / 15 197 / 253 2.18/ 3/4 208 / 230 4/4 15 / 15 197 / 253 3.15/ 3/4 208 / 230 4/4 15 / 15 197 / 253 3.15/ 3/4 208 / 230 4/4 15 / 15 197 / 253 3.15/ 3/4 208 / 230 7/7 15/15 197/253 5.4/ 3/4 208 / 230 6/6 15 / 15 197 / 253 4.84/ 3/4 208 / 230 8/8 15 / 15 197 / 253 6.65/ 1 208 / 230 8/8 15 / 15 197 / 253 6.65/ 1 100 118 118 125 125 167 167 167 *Airflow rate @.3 static Note: Assumes dry coil; SCFM correction for wet coil = 4% (208V / 240V) 14 PRODUCT SPECIFICATIONS ASUF**14** ASUF 29B14* ASUF 39C14* ASUF 49C14* ASUF 59D14* 24,000 36,000 49,000 60,000 520 600 660 775 975 890 995 1090 1205 1425 1375 1525 1620 1715 1800 1400 1600 1745 1995 2160 9½" 10⅝" 10⅝" 11 /16" Width 6" 8" 10⅝" 10⅝" Coil Drain Connect FPT ¾" ¾" ¾" ¾" Liquid ⅜" ⅜" ⅜" ⅜" Suction ¾" ⅞" ⅞" ⅞" Nominal Ratings Cooling (Btu/h) Airflow Rate CFM * T1 T2 T3 T4 T5 Blower Diameter 15 Refrigerant Line Connection Size Electrical Data Voltage Min Circuit Ampacity Max. Overcurrent Device (amps) Min. / Max VAC Blower Motor FLA/ HP Ship Weight (lbs) 208 / 230 208 / 230 208 / 230 208 / 230 3/3 4/4 4/4 6/6 15 / 15 15 / 15 15 / 15 15 / 15 197 / 253 197 / 253 197 / 253 197 / 253 2.7 / ¾ 3.2 / ¾ 5.4 / ¾ 6.7 / 1 100 118 118 167 *Airflow rate @.3 static 15 BLOWER PERFORMANCE DATA ARPT**14** Static Pressure (in w.c) 0.3 0.4 0.5 Model Number Blower Speed 0.1 0.2 ARPT18B14 High Medium Low 1185 900 630 1125 850 605 1065 825 560 1010 785 525 High Medium Low 1185 900 630 1125 850 605 1065 825 560 High Medium Low 1145 870 615 1085 820 585 High Medium Low 1580 1385 1260 High Medium Low High Medium ARPT24B14 ARPT30B14 ARPT36C14 ARPT36D14 ARPT42D14 Low ARPT48D14 High Medium ARPT60D14 Low High Medium Low 0.6 0.7 985 715 495 910 670 445 780 610 355 1010 785 525 985 715 495 910 670 445 780 610 355 1020 775 565 950 745 535 900 705 490 845 655 435 765 580 345 1515 1350 1205 1445 1300 1175 1395 1250 1105 1345 1170 1040 1240 1095 975 1155 1005 865 1815 1580 1220 1770 1525 1180 1705 1485 1140 1640 1420 1085 1555 1350 1030 1450 1275 950 1355 1165 865 1990 1655 1480 1915 1605 1420 1810 1555 1350 1765 1480 1290 1690 1295 1185 1585 1200 1100 1435 1060 1045 1960 1600 1395 1905 1545 1340 1845 1495 1280 1780 1435 1220 1715 1360 1150 1645 1290 1090 1570 1215 1020 2205 1985 1600 2140 1935 1555 2080 1865 1505 2010 1815 1455 1945 1755 1405 1870 1695 1345 1795 1635 1295 AIRFLOW DATA (CFM) ARPT**14** Notes: • Airflow data indicated is at 230V without air filter in place. • The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. • Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations. 16 BLOWER PERFORMANCE DATA Model Number ARUF18B14* ARUF24B14* ARUF30B14* ARUF30C14* ARUF36C14* ARUF42C14AA ARUF42C14AB ARUF48D14* ARUF60D14* Blower Speed High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low ARUF**14** 0.1 1150 890 640 1150 890 640 0.2 1095 855 605 1095 855 605 Static Pressure (in w.c) 0.3 0.4 0.5 1045 1025 950 835 775 715 565 530 485 1045 1025 950 835 775 715 565 530 485 0.6 865 665 440 865 665 440 0.7 775 605 360 775 605 360 1145 870 615 1485 1300 1040 1085 820 585 1435 1270 1015 1020 775 565 1385 1235 980 950 745 535 1345 1195 930 900 705 490 1275 1130 865 845 655 435 1205 1060 790 765 580 345 1125 955 705 1485 1300 1040 1580 1395 1095 1435 1270 1015 1530 1340 1045 1385 1235 980 1465 1290 1000 1345 1195 930 1400 1235 950 1275 1130 865 1330 1170 895 1205 1060 790 1255 1095 820 1125 955 705 1165 1000 725 1655 1435 1115 1990 1655 1480 1590 1370 1040 1915 1605 1420 1515 1300 995 1810 1555 1350 1430 1220 930 1765 1480 1290 1340 1150 845 1690 1295 1185 1225 1025 770 1585 1200 1100 1080 925 675 1435 1060 1045 2235 2030 1615 2175 1970 1535 2125 1885 1455 2050 1800 1355 1960 1690 1270 1825 1600 1185 1720 1495 1090 AIRFLOW DATA (CFM) ARUF**14** Notes: • Airflow data indicated is at 230V without air filter in place. • The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. • Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations. 17 BLOWER PERFORMANCE DATA Model Number ASPT24B14 ASPT30C14 ASPT36C14 ASPT42C14 ASPT48C14 ASPT42D14 ASPT48D14 ASPT60D14 ASPT**14** Blower Speed Tap 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1 570 540 520 480 450 415 370 305 270 240 2 650 605 600 570 530 500 460 425 380 330 3 740 690 660 650 615 570 525 480 440 405 4 855 810 775 755 750 720 690 650 620 575 5 1050 1005 975 940 910 900 885 880 845 820 1 610 580 540 445 390 330 285 240 205 160 2 705 670 625 570 545 465 425 385 325 270 3 785 740 720 660 640 580 515 475 440 370 Static Pressure (in w.c) 4 880 845 810 805 740 700 660 595 550 515 5 1440 1440 1400 1380 1350 1330 1295 1275 1245 1205 1 960 905 890 810 760 720 665 620 550 485 2 1060 1010 995 920 875 835 790 745 690 615 3 1150 1100 1090 1025 990 945 905 860 810 750 4 1250 1220 1205 1145 1110 1070 1035 990 940 885 5 1470 1440 1425 1405 1375 1260 1315 1280 1245 1205 1 950 925 865 815 730 675 660 600 545 --- 2 1075 1025 980 930 875 785 730 690 650 --- 3 1160 1115 1070 1025 975 905 815 770 715 --- 4 1275 1235 1190 1145 1100 1040 975 875 835 --- 5 1600 1560 1520 1480 1430 1390 1345 1290 1245 --- 1 1365 1305 1275 1225 1175 1110 1070 1020 995 --- 2 1490 1455 1405 1360 1305 1255 1205 1160 1115 --- 3 1580 1540 1500 1455 1400 1350 1300 1260 1210 --- 4 1670 1635 1585 1545 1495 1445 1395 1365 1315 --- 5 1750 1715 1680 1645 1590 1530 1495 1460 1410 --- 1 1230 1180 1110 1060 1000 945 885 810 745 685 2 1365 1310 1250 1190 1140 1090 1030 980 920 855 3 1460 1410 1355 1305 1255 1210 1155 1115 1060 1010 4 1545 1490 1440 1375 1330 1295 1245 1200 1150 1100 5 1865 1825 1780 1745 1695 1645 1610 1570 1520 1475 1 1485 1425 1400 1325 1270 1220 1165 1115 1080 1005 2 1560 1510 1490 1425 1385 1335 1295 1250 1205 1155 3 1675 1625 1600 1530 1485 1435 1390 1345 1295 1245 4 1820 1770 1745 1685 1640 1595 1555 1510 1470 1420 5 2225 2180 2160 2085 2060 2010 1970 1930 1895 1850 1 1485 1425 1400 1325 1270 1220 1165 1115 1080 1005 2 1675 1625 1600 1530 1485 1435 1390 1345 1295 1245 3 1820 1770 1745 1685 1640 1595 1555 1510 1470 1420 4 2060 2010 1995 1925 1880 1845 1800 1760 1720 1680 5 2225 2180 2160 2085 2060 2010 1970 1930 1895 1850 AIRFLOW DATA (CFM) ASPT**14** Notes: • Airflow data indicated is at 230V without air filter in place. • The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. • Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations. 18 ASUF**14** BLOWER PERFORMANCE DATA Model Number ASUF29B14 ASUF39C14 ASUF49C14 ASUF59D14 Blower Speed Tap 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1 570 540 520 480 450 415 370 305 270 240 2 650 605 600 570 530 500 460 425 380 330 3 740 690 660 650 615 570 525 480 440 405 4 5 1 2 3 4 5 855 1050 810 1005 775 975 755 940 750 910 720 900 690 885 650 880 620 845 575 820 960 1060 1150 1250 1470 905 1010 1100 1220 1440 890 995 1090 1205 1425 810 920 1025 1145 1405 760 875 990 1110 1375 720 835 945 1070 1260 665 790 905 1035 1315 620 745 860 990 1280 550 690 810 940 1245 485 615 750 885 1205 1 1425 1405 1375 1340 1305 1265 1215 1155 1115 1070 2 1560 1545 1525 1490 1455 1410 1380 1325 1275 1225 3 1670 1645 1620 1595 1550 1520 1485 1445 1405 1350 4 5 1760 1845 1745 1820 1715 1800 1685 1775 1655 1740 1625 1705 1585 1675 1550 1640 1515 1605 1470 1575 1 1485 1425 1400 1325 1270 1220 1165 1115 1080 1005 2 1675 1625 1600 1530 1485 1435 1390 1345 1295 1245 3 1820 1770 1745 1685 1640 1595 1555 1510 1470 1420 4 2060 2225 2010 2180 1995 2160 1925 2085 1880 2060 1845 2010 1800 1970 1760 1930 1720 1895 1680 1850 5 Static Pressure (in w.c) AIRFLOW DATA (CFM) ASUF**14** Notes: • Airflow data indicated is at 230V without air filter in place. • The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. • Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations. 19 WIRING DIAGRAMS ARPT**14**/ARUF**14** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. FL FL FL FL HTR2 TL FL HTR1 TL HTR1 TL BK BK RD FL HTR1 TL FL BK FL HTR2 TL FL RD BK BK 2 HTR3 TL 1 BK BK HTR2 TL RD HTR3 TL FL 1 HTR1 TL YL HTR4 TL 1 BL BK RD PU BL BK R YL PU BK M1 M1 M3 4 M2 M4 5 R WH BK BK RD 4 M1 YL M2 R2 RD RD 5 BR M2 BL M3 M4 M5 M7 M6 M8 R1 WH 6 3 RD BL R2 BR 4 5 BK BK 6 RD RD WH 6 7 7 BK 8 M4 2 PU BL BK BK WH 7 RD M2 3 RD BL M1 R1 6 BK RD PU BL M3 1 2 YL BK 3 BL RD 5 M2 RD RD 4 M1 BK 2 3 7 YL 8 RD YL BK 8 9 RD 9 BL BK 8 RD 9 9 L1 L2 L1 ONE (1) ELEMENT ROWS L2 L1 TWO (2) ELEMENT ROWS L2 L1 L2 THREE (3) ELEMENT ROWS L1 L2 L1 L2 FOUR (4) ELEMENT ROWS NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP IS NOT BELOW MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIR HANDLER/HEATER KIT COMBINATION ON THIS UNITS SERIAL PLATE. AFTER INST ALLING OPTIONAL HEAT KIT, MARK A "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO THE NUMBER OF HEATER ELEMENT ROW S INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. 5 ELEMENT ROWS DATA SUPPLIED WITH HEATER KIT. SEE NOTE 2 L1 L2 BK RD PLF 1 2 3 4 5 6 7 8 9 PLM 1 2 3 4 5 6 7 8 9 BK RD PU BL BR WH TERMINAL BLOCK SHOWN FOR 50HZ MODELS ONLY BL RD GR WH BR SR EQUIPMENT GROUND USE COPPER WIRE 208/240 VOLTS GRD L1 L2 1 PLF PLF 2 1 PLM 3 2 EM RC SEE NOTE 4 HI BR LO WH PLM 1 2 3 4 24V 5 M1 NO NC EBTDR M2 COM SEE NOTE 1 TR C EBTDR R GR SEE NOTE 5 RD G BL COM K1 SPEEDUP 6 C 1 2 3 5 24V 4 RD 240 BK RD YL BL NC M1 BL BL M2 BK RD SEE NOTE 3 THREE SPEED MOTOR WIRING (SELECT MODELS ONLY) SEE NOTE 3 PU (M2) BL (TR 1) BK LOW MEDIUM (M1) BK IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY USE WI RE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. EM RC SR R EBTDR NOTES: (COM) RD HIGH PU BR PU RC RC BR EM 3 SPEED BLACK GR PU RED YELLOW BR WH BLUE EM BR GR BL WH BR COMPONENT CODE RD COPPER POWER SUPPLY (SEE RATING PLATE) USE MIN. 75°C FIELD WIRE WIRING CODE GREEN PURPLE BROWN WHITE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE TR EVAPORATOR MOTOR RUN CAPACITOR PLF STRAIN RELIEF PLM FL RELAY TL ELECTRONIC BLOWER TIME DELAY RELAY HTR TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS 1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2) SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 3) CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT APPROPRIATE MOTOR WIRE (RED FOR LOW, BLUE FOR MEDIUM,AND BLACK FOR HIGH SPEED) ON "COM" CONNECTION OF THE EBTDR. INACTIVE MOTOR WIRES SHOULD BE CONNECTED TO "M1 OR M2" ON EBTDR. 4) BROWN AND WHITE WIRES ARE USED WITH HEAT KITS ONLY. 5) EBTDR HAS A 7 SECOND ON DELAY WHEN "G" IS ENERGIZED AND A 65 SECOND OFF DELAY WHEN "G" IS DE-ENERGIZED. 0140A00058-B Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 20 G 4 PLF COLOR CODE TR PU 5 EBTDR SEE NOTE 1 RD RD NO K1 C BL RD PU EBTDR R XFMR-R XFMR-C RD BK WIRING DIAGRAMS ASPT**14**/ASUF**14** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. FL FL FL TL HTR 1 FL BK BK HTR1 FL BK FL BK 1 HTR2 RD FL BK 1 RD PU 4 M1 R RD 6 M3 4 M2 M4 5 7 BK RD RD BL M3 M4 M2 3 RD BL M1 R2 BR BK RD WH M1 YL RD M3 M2 M4 R1 6 M5 M7 M6 M8 3 RD BL R2 BR BK BK RD WH 4 5 6 7 8 YL BK 8 1 2 YL 7 RD RD 9 BL BK RD 9 9 L1 BK BL 4 5 7 BK BK RD 6 BK 8 BL PU M2 R1 WH BK RD BK BL PU BK M1 M1 R WH YL 3 BL BK 5 M2 YL TL 2 YL RD 2 3 BL RD TL HTR3 FL 1 HTR4 RD PU BK BK TL HTR2 TL HTR3 BK RD 2 TL HTR1 FL TL TL HTR2 FL TL TL HTR1 8 9 L2 L1 L2 L1 L2 L1 L2 L1 ONE (1) ELEMENT ROWS TWO (2) ELEMENT ROWS L2 L1 L2 FOUR (4) ELEMENT ROWS TH REE (3) ELEMENT ROWS NOTE: W HEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOW ER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE BOX PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. 208/240 VOLTS EQUIP MENT GROUND USE COPPER WIRE GRD SEE NOT E 2 R C G W 1 W 2 Y1 Y2 O DH 1 2 3 4 5 L1 L1 L2 PLF 1 2 3 4 5 6 7 8 9 PLM 1 2 3 4 5 6 7 8 9 BK RD BL BR WH 1 1 RD GR L2 PLF WIRING CODE 5 FACTORY W IRING HIGH VOLTAGE LOW VOLTAGE FIELD W IRING HIGH VOLTAGE LOW VOLTAGE PLF 2 EM PLM LGN PLM SEE NOTE 4 2 2 1 3 SEE NOTE 1 BR WH 1 2 3 4 24V 5 4 CR TR PLF PLM FL TL HTR ALTERNATE HEAT RELAY 1 BL TR RD WH CR BK 7 RD GR 4 1 A B RD SEE NOTE 1 BK WH C RD 1 2 3 5 24V 4 FUSE HOLDER PU 6 5 B A 4 7 240 TR R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 BL BL BL BL BL RD RD COPPER POWER SUPPLY (USE RATING PLATE) USE MIN. 75° C FIELD WIRE WH PU FUSE HOLDER OR BR YL 1 2 34 5 EM PU 4 IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. RD 2 5 GR 1 3 C LGN WH BL ALTERNATE HEAT RELAY RD BK BL NOTES: 1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 280 VOLTS. 1 2 3 4 5 EM BK RD YL BL BLACK GR GREEN RED PU PURPLE YELLOW BR BROWN BLUE WH WHITE C C OMPONENT CODE EM TB R CR EBTDR EVAPORATOR MOTOR TERM INAL BOARD RELAY CONTROL RELAY ELECTR ONIC BLOWER TIME DELAY RELAY 2) SEE COMPLETE WIRING DIAGRAMS IN INSTALLATIO N INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRIN G CONNECTIONS. 3) CONFIRM SPEED TAP SELECTIO N IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL 4 OF CR RELAY TO APPROPRIATE TAP AT TB. 4) BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY. BL COLOR CODE CR 4 P LM TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CON NECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS 0140A00063-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 21 WIRING DIAGRAMS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 3-Phase Heat Kit 25kW Heat Kit TL HTR1 TL HTR2 TL BK FL COMPONENT CODE RD FL M10 R3 M9 HTR3 TL YL FL HTR4 BK FL TL PU PC HTR5 RD BL BL FL BK 1 BL 2 PU BK RD M2 YL PU M4 M1 WH BL M3 R1 M6 M5 4 M8 R2 BR 5 BK RD WH 6 7 YL BL BK RD CB3 L1 CB1 L2 L1 L1 9 BK = BLACK BL = BLUE BR = BROWN GR = GREEN OR = ORANGE PK = PINK PU = PURPLE RD = RED WH = WHITE YL = YELLOW PU NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER / HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. FIVE (5) ELEMENT ROWS NOTE:THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION CB2 L2 8 COLOR CODE HIGH VOLTAGE LOW VOLTAGE 3 RD BL M7 PC = 9 PIN CONNECTOR HTR = HEATER ELEMENT TL = THERMAL LMT RS = RELAY/SEQUENCER TB = TERMINAL BLOCK CB = CIRCUIT BREAKER CC = CONTACTOR FL = FUSE LINK EM = EVAPORATOR MOTOR EBTDR = ELEC. BLOWER TIME DELAY RC = RUN CAPACITOR TR = TRANSFORMER SR = STRAIN RELIEF WIRING CODE: L2 BK BK RD RD CB4 L1 L2 0140M00274-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 22
© Copyright 2024 Paperzz