ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC7V YXC7(Q)E YAXC7(Q)E YXC7VY2V YXC8V YXC8VZ3V YXC8VZ4V YXC8VZ2V YXC7(Q)A2E (N2XSY) (N2XS(F)2Y) (NA2XS(F)2Y) (N2XSYB(AL)Y) (N2XSEY) (N2XSEYFGY) (N2XSEYBY) (N2XSEYRY) (2XS(FL)2Y) ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC7V YAPISI 1 2 3 4 5 6 7 8 Bakır iletken (sınıf 2) ‹ç yarı iletken tabaka XLPE izole Dıfl yarı iletken tabaka Yarı iletken krep ka¤ıdı Konsantrik iletken Bakır bant PVC dıfl kılıf 8 7 6 5 4 3 2 1 ÖZELL‹KLER Tip Standartlar Anma Gerilimi : YXC7V (N2XSY) : TS IEC 60502-2 - TSEK : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Kullan›ld›¤› Yerler : Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında veya kablo kanallarında kullanılır. C 90 r 250 -20 / +60 C r=15 x D o Kullanım Sıcaklı¤ı Maks. ‹flletme Sıcaklı¤ı Kısa Devre Sıcaklı¤ı Aleve Dayanıklılık IEC 60332 -1-2 Min. Bükülme Yarıçapı RoHS F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit m. kablo 20°C’de D›fl çap Net a¤›rl›k 1000 için sevk iletken yaklafl›k yaklafl›k makara tipi DC direnci mm2 mm kg/km m Ω / km (max.) 6/10 (12) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 22 23 25 27 28 30 31 34 37 40 44 800 940 1160 1420 1670 2060 2400 2970 3650 4550 5650 120 130 140 140 150 150 160 180 180 200 220 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 66 Çal›flma indüktans› yaklafl›k mH/km mH/km 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.53 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.28 Çal›flma kapasitesi yaklafl›k MF/km 0.22 0.24 0.28 0.31 0.33 0.36 0.40 0.45 0.51 0.57 0.63 Ak›m tafl›ma kapasitesi (30°C) Toprakta Havada A A A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC7V F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit m. kablo 20°C’de D›fl çap Net a¤›rl›k 1000 için sevk iletken yaklafl›k yaklafl›k makara tipi DC direnci mm2 mm 8.7/15 (17.5) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 24 26 27 29 31 32 34 36 39 43 46 12/20 (24) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 26 28 30 31 33 35 36 39 42 45 49 kg/km 875 1020 1240 1520 1770 2160 2520 3090 3780 4690 5780 960 1100 1350 1620 1900 2275 2650 3250 3960 4870 5950 m Ω / km (max.) 130 140 140 150 160 160 180 180 200 220 220 140 150 150 160 160 180 180 200 200 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 Çal›flma indüktans› yaklafl›k mH/km mH/km 0.75 0.73 0.70 0.66 0.64 0.63 0.61 0.58 0.57 0.55 0.53 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.54 0.44 0.42 0.40 0.37 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.29 Çal›flma kapasitesi yaklafl›k MF/km 0.18 0.19 0.22 0.25 0.27 0.29 0.31 0.35 0.40 0.44 0.49 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 0.37 0.41 Ak›m tafl›ma kapasitesi (30°C) Toprakta Havada A A A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 18/30 (36 )kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 32 33 35 37 39 40 42 44 47 50 54 1200 1350 1620 1900 2200 2600 3000 3600 4300 5270 6400 160 160 180 180 200 200 200 220 220 240 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.43 0.42 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.30 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 0.28 0.36 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 20.3/35 (42)kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 34 35 37 39 41 42 44 46 49 53 56 1300 1500 1750 2050 2350 2750 3100 3700 4480 5420 6550 180 180 180 200 200 200 220 220 240 260 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.77 0.75 0.71 0.68 0.66 0.64 0.62 0.60 0.59 0.57 0.55 0.51 0.42 0.40 0.38 0.36 0.35 0.39 0.37 0.36 0.35 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.18 0.20 0.23 0.25 0.28 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 67 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC7(Q)E YAPISI 1 2 3 4 5 6 7 8 9 Bakır iletken (sınıf 2) ‹ç yarı iletken tabaka XLPE izole Dıfl yarı iletken tabaka Yarı iletken su tutucu bant Konsantrik iletken Bakır bant Su tutucu bant PE dıfl kılıf 9 8 7 6 5 4 3 2 1 ÖZELL‹KLER Tip Standartlar Anma Gerilimi : YXC7(Q)E (N2XS(F)2Y) : TS IEC 60502-2 - TSEK : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Kullan›ld›¤› Yerler : Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında veya kablo kanallarında kullanılır. Aynı zamanda yapısındaki su tutucu bantlar sayesinde nemli ve sulu ortamlarda da kullanılabilir. C 90 r 250 -20 / +60 C r=15 x D o Kullanım Sıcaklı¤ı Maks. ‹flletme Sıcaklı¤ı Kısa Devre Sıcaklı¤ı Aleve Dayanıklılık IEC 60332 -1-2 Min. Bükülme Yarıçapı RoHS F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit mm2 m. kablo 20°C’de D›fl çap Net a¤›rl›k 1000 için sevk iletken yaklafl›k yaklafl›k makara tipi DC direnci mm kg/km m Ω / km (max.) Çal›flma indüktans› yaklafl›k mH/km mH/km Çal›flma kapasitesi yaklafl›k MF/km Ak›m tafl›ma kapasitesi (30°C) Toprakta A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 Havada A A 6/10 (12) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 68 23 24 26 28 30 31 32 35 38 41 45 800 940 1160 1420 1670 2060 2400 2970 3650 4550 5650 130 130 140 150 150 160 160 180 200 200 220 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.53 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.28 0.22 0.24 0.28 0.31 0.33 0.36 0.40 0.45 0.51 0.57 0.63 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC7(Q)E F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit mm2 m. kablo 20°C’de D›fl çap Net a¤›rl›k 1000 için sevk iletken yaklafl›k yaklafl›k makara tipi DC direnci mm kg/km m Ω / km (max.) Çal›flma indüktans› yaklafl›k mH/km mH/km Çal›flma kapasitesi yaklafl›k MF/km Ak›m tafl›ma kapasitesi (30°C) Toprakta Havada A A A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 8.7/15 (17.5) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 25 27 28 30 31 33 34 37 40 43 47 875 1020 1240 1520 1770 2160 2520 3090 3780 4690 5780 140 140 150 150 160 160 180 180 200 220 220 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 12/20 (24) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 27 28 30 32 34 35 37 39 42 45 49 960 1100 1350 1620 1900 2275 2650 3250 3960 4870 5950 140 150 150 160 180 180 180 200 200 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.54 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.29 18/30 (36) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 33 34 36 37 39 40 42 45 48 51 55 160 180 180 180 200 200 200 220 240 260 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.75 0.72 0.69 0.69 0.64 0.62 0.60 0.58 0.56 0.53 0.42 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.30 20.3/35 (42) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16rm 1x150/25rm 1x185/25rm 1x240/25rm 1x300/25rm 1x400/35rm 1x500/35rm 35 36 38 39 41 43 44 47 50 53 57 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.77 0.75 0.71 0.68 0.66 0.64 0.62 0.60 0.59 0.57 0.55 0.51 0.42 0.40 0.38 0.36 0.35 0.39 0.37 0.36 0.35 0.33 1200 1350 1620 1900 2200 2600 3000 3600 4300 5270 6400 1300 1500 1750 2050 2350 2750 3100 3700 4480 5420 6550 180 180 200 200 200 220 220 220 240 260 260 0.75 0.73 0.70 0.66 0.64 0.63 0.61 0.58 0.57 0.55 0.53 0.44 0.42 0.40 0.37 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.19 0.21 0.23 0.26 0.28 0.30 0.33 0.37 0.40 0.44 0.49 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 0.37 0.41 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 0.28 0.30 0.11 0.12 0.14 0.15 0.16 0.17 0.18 0.20 0.23 0.25 0.28 69 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YAXC7(Q)E YAPISI 1 2 3 4 5 6 7 8 9 Alüminyum iletken (sınıf 2) ‹ç yarı iletken tabaka XLPE izole Dıfl yarı iletken tabaka Yarı iletken su tutucu bant Konsantrik iletken Bakır bant Su tutucu bant PE dıfl kılıf 9 8 7 6 5 4 3 2 1 ÖZELL‹KLER Tip Standartlar Anma Gerilimi : YAXC7(Q)E (NA2XS(F)2Y) : TS IEC 60502-2 - TSEK : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Kullan›ld›¤› Yerler : Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında veya kablo kanallarında kullanılır. Aynı zamanda yapısındaki su tutucu bantlar sayesinde nemli ve sulu ortamlarda da kullanılabilir. C 90 r 250 -20 / +60 C r=15 x D o Kullanım Sıcaklı¤ı Maks. ‹flletme Sıcaklı¤ı Kısa Devre Sıcaklı¤ı Aleve Dayanıklılık IEC 60332 -1-2 Min. Bükülme Yarıçapı RoHS F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit mm2 m. kablo 20°C’de D›fl çap Net a¤›rl›k 1000 için sevk iletken yaklafl›k yaklafl›k makara tipi DC direnci mm kg/km m Ω / km (max.) Çal›flma indüktans› yaklafl›k mH/km mH/km Çal›flma kapasitesi yaklafl›k MF/km Ak›m tafl›ma kapasitesi (30°C) Toprakta Havada A A A A 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 122 144 176 210 240 267 303 351 397 451 502 6/10 (12) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 70 23 24 26 28 29 31 33 35 37 41 44 600 670 765 870 995 1200 1350 1580 1800 2200 2650 130 130 140 150 150 160 160 180 200 200 220 0.641 0.443 0.320 0.253 0.206 0.206 0.164 0.125 0.100 0.0778 0.0605 0.78 0.73 0.69 0.66 0.64 0.62 0.61 0.58 0.56 0.55 0.53 0.43 0.41 0.38 0.36 0.35 0.34 0.33 0.32 0.31 0.30 0.29 0.23 0.24 0.27 0.30 0.33 0.36 0.39 0.44 0.48 0.53 0.59 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YAXC7(Q)E F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit mm2 m. kablo 20°C’de D›fl çap Net a¤›rl›k 1000 için sevk iletken yaklafl›k yaklafl›k makara tipi DC direnci mm kg/km m Ω / km (max.) Çal›flma indüktans› yaklafl›k mH/km mH/km Çal›flma kapasitesi yaklafl›k Ak›m tafl›ma kapasitesi (30°C) Toprakta Havada A A A 0.16 0.19 0.22 0.24 0.27 0.29 0.31 0.34 0.38 0.41 0.46 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 122 144 176 210 240 267 303 351 397 451 502 0.14 0.17 0.19 0.21 0.23 0.25 0.27 0.30 0.32 0.35 0.37 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 122 144 176 210 240 267 303 351 397 451 502 MF/km A 8.7/15 (17.5) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 25 26 28 30 31 33 35 37 40 43 46 700 770 850 1000 1100 1300 1500 1700 1950 2400 2800 140 140 150 150 160 160 180 180 200 220 220 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 12/20 (24) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 27 29 30 32 34 35 37 40 42 45 48 800 850 950 1100 1200 1500 1600 1850 2100 2550 2950 140 150 150 160 180 180 180 200 200 220 240 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 0.75 0.72 0.69 0.66 0.64 0.62 0.59 0.57 0.55 0.53 0.51 18/30 (36) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 33 34 36 37 39 41 42 45 47 50 54 1050 1100 1250 1360 1550 1750 1950 2200 2450 2950 3450 160 180 180 180 200 200 200 220 240 260 260 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 0.74 0.71 0.68 0.64 0.62 0.59 0.57 0.55 0.53 0.51 0.49 0.49 0.47 0.45 0.42 0.41 0.40 0.38 0.37 0.35 0.34 0.33 0.11 0.13 0.15 0.16 0.17 0.19 0.20 0.22 0.24 0.26 0.28 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 122 144 176 210 240 267 303 351 397 451 502 20.3/35 (42) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16rm 1x150/25rm 1x185/25rm 1x240/25rm 1x300/25rm 1x400/35rm 1x500/35rm 35 36 38 40 41 43 45 47 49 53 56 1150 1250 1400 1500 1650 1900 2100 2350 2650 3100 3600 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 0.74 0.71 0.68 0.64 0.62 0.59 0.57 0.55 0.53 0.51 0.49 0.49 0.47 0.45 0.42 0.41 0.40 0.38 0.37 0.35 0.34 0.33 0.11 0.13 0.15 0.16 0.17 0.19 0.20 0.22 0.24 0.26 0.28 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 122 144 176 210 240 267 303 351 397 451 502 180 180 200 200 200 220 220 220 240 260 260 0.76 0.73 0.70 0.67 0.65 0.63 0.61 0.59 0.57 0.55 0.53 0.45 0.43 0.40 0.38 0.37 0.35 0.34 0.33 0.32 0.31 0.30 0.43 0.41 0.39 0.36 0.35 0.33 0.32 0.31 0.30 0.29 0.27 71 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC7VY2V YAPISI 1 2 3 4 5 6 7 8 9 10 Bakır iletken (sınıf 2) ‹ç yarı iletken tabaka XLPE izole Dıfl yarı iletken tabaka Yarı iletken krep ka¤ıdı Konsantrik iletken Bakır bant PVC ayırıcı kılıf Alüminyum yuvarlak tel PVC dıfl kılıf 10 9 8 7 6 5 4 3 2 1 ÖZELL‹KLER Tip Standartlar Anma Gerilimi : YXC7VY2V (N2XSYR(AL)Y) : TS IEC 60502-2 - TSEK : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C C 90 Kullan›ld›¤› Yerler : Mekanik zorlanmalara karflı yapısındaki zırh sayesinde mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında veya kablo kanallarında kullanılır. r 250 -20 / +60 C r=15 x D o Kullanım Sıcaklı¤ı Maks. ‹flletme Sıcaklı¤ı Kısa Devre Sıcaklı¤ı Aleve Dayanıklılık IEC 60332 -1-2 Min. Bükülme Yarıçapı RoHS F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit m. kablo 20°C’de D›fl çap Net a¤›rl›k 1000 için sevk iletken yaklafl›k yaklafl›k makara tipi DC direnci mm2 mm 6/10 (12)kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 28 29 31 32 35 36 38 41 44 48 51 72 kg/km 1150 1330 1600 1900 2300 2700 3050 3700 4450 5450 6600 m 150 150 160 160 180 180 200 200 220 240 260 Ω / km (max.) 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 Çal›flma indüktans› yaklafl›k mH/km mH/km 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.53 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.28 Çal›flma kapasitesi yaklafl›k MF/km 0.22 0.24 0.28 0.31 0.33 0.36 0.40 0.45 0.51 0.57 0.63 Ak›m tafl›ma kapasitesi (30°C) Toprakta A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 Havada A A 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC7VY2V F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit mm2 m. kablo 20°C’de D›fl çap Net a¤›rl›k 1000 için sevk iletken yaklafl›k yaklafl›k makara tipi DC direnci mm kg/km m Ω / km (max.) Çal›flma indüktans› yaklafl›k mH/km mH/km Çal›flma kapasitesi yaklafl›k MF/km Ak›m tafl›ma kapasitesi (30°C) Toprakta A A Havada A A 8.7/15 (17.5) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 30 31 34 36 37 39 41 43 46 50 54 1280 1450 1730 2050 2400 2820 3250 3850 4650 5600 6830 150 160 180 180 180 200 200 220 220 240 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.73 0.70 0.66 0.64 0.63 0.61 0.58 0.57 0.55 0.53 0.44 0.42 0.40 0.37 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.19 0.21 0.23 0.26 0.28 0.30 0.33 0.37 0.40 0.44 0.49 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 12/20 (24) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 32 34 36 38 40 41 43 46 49 52 56 1400 1600 1950 2300 2600 3020 3400 4050 4850 5850 7050 160 180 180 200 200 200 220 220 240 260 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.78 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.54 0.54 0.44 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 0.37 0.41 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 39 40 42 43 46 48 49 52 55 59 63 1850 2050 2350 2700 3160 3600 4020 4700 5500 6570 7850 200 200 200 220 220 240 240 260 260 260 280 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.58 0.56 0.43 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.31 0.30 0.30 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 0.28 0.30 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 18/30 (36) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16rm 1x150/25rm 1x185/25rm 1x240/25rm 1x300/25rm 1x400/35rm 1x500/35rm 73 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC8V YAPISI Bakır iletken (sınıf 2) ‹ç yarı iletken tabaka XLPE izole Dıfl yarı iletken tabaka Yarı iletken krep ka¤ıdı Bakır flerit ekran PP dolgu PVC dıfl kılıf 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 ÖZELL‹KLER Tip Standartlar Anma Gerilimi : YXC8V (N2XSEY) : TS IEC 60502-2 - TSEK : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Kullan›ld›¤› Yerler : Mekanik zorlanmalara karflı yapısındaki zırh sayesinde mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında veya kablo kanallarında kullanılır. C 90 r 250 -20 / +60 C r=15 x D o Kullanım Sıcaklı¤ı Maks. ‹flletme Sıcaklı¤ı Kısa Devre Sıcaklı¤ı Aleve Dayanıklılık IEC 60332 -1-2 Min. Bükülme Yarıçapı RoHS F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Net a¤›rl›k Standart sevk Sevk yaklafl›k uzunlu¤u makara tipi 20°C’de iletken DC direnci Çal›flma indüktans› yaklafl›k Çal›flma Ak›m tafl›ma kapasitesi (30°C) kapasitesi Toprakta Havada yaklafl›k Nominal kesit D›fl çap yaklafl›k mm2 mm kg/km m cm Ω / km (max.) mH/km MF/km A A 43 46 49 53 57 61 64 69 74 2700 2950 3900 4950 5850 6900 7950 9400 10650 500 500 500 500 500 500 500 250 250 180 180 180 200 220 220 240 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.22 0.24 0.28 0.31 0.34 0.36 0.40 0.45 0.51 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 6/10 kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 74 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC8V F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit D›fl çap yaklafl›k mm2 mm Net a¤›rl›k Standart sevk Sevk yaklafl›k uzunlu¤u makara tipi kg/km m cm 20°C’de iletken DC direnci Ω / km (max.) Çal›flma indüktans› yaklafl›k Çal›flma Ak›m tafl›ma kapasitesi (30°C) kapasitesi Toprakta Havada yaklafl›k mH/km MF/km A A 8.7/15 (17.5) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16rm 3x150/25rm 3x185/25rm 3x240/25rm 3x300/25rm 49 51 55 59 63 66 69 74 79 3200 3600 4500 5450 6350 7250 8950 9500 1060 500 500 500 500 500 500 250 250 250 180 200 200 220 220 220 200 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.40 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 12/20 (24) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 52 54 58 62 65 69 72 78 83 3700 4300 5200 6250 7300 8450 9500 11900 13900 500 500 500 500 500 250 250 250 250 200 200 220 220 220 200 200 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.33 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 4900 5400 6500 7500 8650 9250 10100 12100 15150 500 500 250 250 250 250 250 250 250 200 220 220 220 220 240 240 240 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 18/30 (36) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 63 66 70 74 77 80 84 88 93 20.3/35 (42) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 68 71 75 78 82 85 88 94 98 5200 6250 7150 8300 9250 10050 11200 12500 15600 250 250 250 250 250 250 250 250 250 220 220 220 240 240 240 240 240 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 75 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC8VZ3V YAPISI Bakır iletken (sınıf 2) ‹ç yarı iletken tabaka XLPE izole Dıfl yarı iletken tabaka Yarı iletken krep ka¤ıdı Bakır flerit ekran PP dolgu PVC ayırıcı kılıf Galvanizli yassı çelik tel Galvanizli çelik bant PVC dıfl kılıf 1 2 3 4 5 6 7 8 9 10 11 11 10 9 8 7 6 5 4 3 2 1 ÖZELL‹KLER Tip Standartlar Anma Gerilimi : YXC8VZ3V (N2XSEYFGY) : TS IEC 60502-2 - TSEK : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Kullan›ld›¤› Yerler : Mekanik zorlanmalara karflı yapısındaki zırh sayesinde mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında veya kablo kanallarında kullanılır. C 90 r 250 -20 / +60 C r=15 x D o Kullanım Sıcaklı¤ı Maks. ‹flletme Sıcaklı¤ı Kısa Devre Sıcaklı¤ı Aleve Dayanıklılık IEC 60332 -1-2 Darbe Dayanıklılı¤ı Min. Bükülme Yarıçapı RoHS F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Net a¤›rl›k Standart sevk Sevk yaklafl›k uzunlu¤u makara tipi 20°C’de iletken DC direnci Çal›flma indüktans› yaklafl›k Çal›flma Ak›m tafl›ma kapasitesi (30°C) kapasitesi Toprakta Havada yaklafl›k Nominal kesit D›fl çap yaklafl›k mm2 mm kg/km m cm Ω / km (max.) mH/km MF/km A A 49 52 57 60 64 67 71 77 83 3640 4200 5150 6200 7150 8250 9600 10650 14050 500 500 500 500 500 500 500 250 250 200 210 220 220 240 240 260 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.22 0.24 0.28 0.31 0.34 0.36 0.40 0.45 0.51 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 6/10 kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 76 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC8VZ3V F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit D›fl çap yaklafl›k Net a¤›rl›k Standart sevk Sevk yaklafl›k uzunlu¤u makara tipi mm2 mm kg/km m 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16rm 3x150/25rm 3x185/25rm 3x240/25rm 3x300/25rm 55 58 62 66 69 73 77 83 89 4200 4800 5750 6850 7850 8950 10300 12450 14900 500 500 500 500 250 250 250 250 250 210 220 220 240 200 210 220 240 260 12/20 (24) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 60 63 67 71 74 78 87 88 93 4750 5350 6350 7450 8450 9600 11000 13200 15700 500 500 500 500 250 250 250 250 250 72 75 79 83 86 90 94 100 106 6250 6900 7950 9100 10200 11400 12900 15200 17800 250 250 250 250 250 250 250 250 250 20°C’de iletken DC direnci Çal›flma Ak›m tafl›ma kapasitesi (30°C) kapasitesi Toprakta Havada yaklafl›k mH/km MF/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 220 220 240 260 210 220 240 240 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 210 220 220 240 240 260 260 280 300 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 cm Ω / km (max.) Çal›flma indüktans› yaklafl›k A A 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.40 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.33 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 8.7/15 (17.5) kV 18/30 (36) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 20.3/35 (42) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 77 80 84 88 91 95 99 105 110 6900 7600 8650 9850 10950 12150 13700 16000 18550 250 250 250 250 250 250 250 250 250 220 220 240 240 260 260 280 300 300 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 77 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC8VZ4V YAPISI 1 2 3 4 5 6 7 8 9 10 Bakır iletken (sınıf 2) ‹ç yarı iletken tabaka XLPE izole Dıfl yarı iletken tabaka Yarı iletken krep ka¤ıdı Bakır flerit ekran PP dolgu PVC ayırıcı kılıf Galvanizli çift çelik bant PVC dıfl kılıf 10 9 8 7 6 5 4 3 2 1 ÖZELL‹KLER Tip Standartlar Anma Gerilimi : YXC8VZ4V (N2XSEYBY) : TS IEC 60502-2 - TSEK : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Kullan›ld›¤› Yerler : Mekanik zorlanmalara karflı yapısındaki zırh sayesinde mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında veya kablo kanallarında kullanılır. C 90 r 250 -20 / +60 C r=15 x D o Kullanım Sıcaklı¤ı Maks. ‹flletme Sıcaklı¤ı Kısa Devre Sıcaklı¤ı Aleve Dayanıklılık IEC 60332 -1-2 Darbe Dayanıklılı¤ı Min. Bükülme Yarıçapı RoHS F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Çal›flma indüktans› yaklafl›k D›fl çap yaklafl›k mm2 mm kg/km m cm Ω / km (max.) mH/km 49 52 57 60 64 67 71 77 84 3400 4000 4900 5900 6850 7900 9250 11300 14450 500 500 500 500 500 500 500 250 250 200 210 220 220 240 240 260 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 6/10 kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 78 Net a¤›rl›k Standart sevk Sevk yaklafl›k uzunlu¤u makara tipi 20°C’de iletken DC direnci Nominal kesit Çal›flma Ak›m tafl›ma kapasitesi (30°C) kapasitesi Toprakta Havada yaklafl›k MF/km 0.22 0.24 0.28 0.31 0.34 0.36 0.40 0.45 0.51 A 154 181 220 263 298 332 374 431 492 A 172 205 253 307 352 397 453 529 608 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC8VZ4V F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Net a¤›rl›k Standart sevk Sevk yaklafl›k uzunlu¤u makara tipi 20°C’de iletken DC direnci Çal›flma indüktans› yaklafl›k Nominal kesit D›fl çap yaklafl›k mm2 mm kg/km m 55 58 62 66 69 73 77 84 90 3950 4550 5450 6500 7500 8600 9900 12800 15300 500 500 500 500 250 250 250 250 250 210 220 220 240 200 210 220 240 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.29 cm Ω / km (max.) mH/km Çal›flma Ak›m tafl›ma kapasitesi (30°C) kapasitesi Toprakta Havada yaklafl›k MF/km A A 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.40 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 8.7/15 (17.5) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 12/20 (24) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 60 62 67 70 74 77 83 89 95 4450 5050 6000 7100 8100 9200 11350 13600 16100 500 500 500 500 250 250 250 250 200 220 220 240 240 210 220 240 260 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 18/30 (36) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 72 75 79 84 88 91 95 101 107 5900 6500 7550 9500 10600 11800 13300 15600 18250 250 250 250 250 250 250 250 250 250 210 220 220 240 240 260 260 280 300 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 20.3/35 (42) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 77 80 85 89 93 96 100 106 112 6500 7200 9050 10250 11400 12600 14200 16500 19200 250 250 250 250 250 250 250 250 250 220 220 240 260 260 260 280 300 320 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 79 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC8VZ2V YAPISI 1 2 3 4 5 6 7 8 9 10 Bakır iletken (sınıf 2) ‹ç yarı iletken tabaka XLPE izole Dıfl yarı iletken tabaka Yarı iletken krep ka¤ıdı Bakır flerit ekran PP dolgu PVC ayırıcı kılıf Galvanizli yuvarlak çelik tel PVC dıfl kılıf 10 9 8 7 6 5 4 3 2 1 ÖZELL‹KLER Tip Standartlar Anma Gerilimi : YXC8VZ2V (N2XSEYRY) : TS IEC 60502-2 - TSEK : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C C 90 Kullan›ld›¤› Yerler : Mekanik zorlanmalara karflı yapısındaki zırh sayesinde mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında veya kablo kanallarında kullanılır. r 250 -20 / +60 C r=15 x D o Kullanım Sıcaklı¤ı Maks. ‹flletme Sıcaklı¤ı Kısa Devre Sıcaklı¤ı Aleve Dayanıklılık IEC 60332 -1-2 Darbe Dayanıklılı¤ı Min. Bükülme Yarıçapı RoHS F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit D›fl çap yaklafl›k Net a¤›rl›k Standart sevk Sevk yaklafl›k uzunlu¤u makara tipi mm2 mm kg/km m 53 56 60 64 68 71 76 83 88 5000 5650 6750 7850 9000 10100 12450 14800 17450 500 500 500 500 500 500 250 250 250 cm 20°C’de iletken DC direnci Ω / km (max.) Çal›flma indüktans› yaklafl›k mH/km Çal›flma Ak›m tafl›ma kapasitesi (30°C) kapasitesi Toprakta Havada yaklafl›k MF/km A A 6/10 kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 80 210 220 220 240 240 260 220 240 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.22 0.24 0.28 0.31 0.34 0.36 0.40 0.45 0.51 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC8VZ2V F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER Nominal kesit D›fl çap yaklafl›k Net a¤›rl›k Standart sevk Sevk yaklafl›k uzunlu¤u makara tipi mm2 mm kg/km 8.7/15 (17.5) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm m 58 61 66 69 74 78 82 88 94 5750 6400 7500 8700 9800 11800 13400 15800 18500 500 500 500 500 500 250 250 250 250 220 220 240 240 260 220 240 240 260 12/20 (24) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 63 66 71 76 80 83 86 93 99 6450 7150 8200 10300 11450 12700 14200 16700 19500 500 500 500 250 250 250 250 250 250 18/30 (36) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16rm 3x150/25rm 3x185/25rm 3x240/25rm 3x300/25 rm 77 80 84 88 92 95 99 105 111 9100 9900 11100 12500 13700 15050 16700 19250 22100 20.3/35 (42) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 82 84 89 93 96 99 104 109 115 9900 10700 11950 13300 14600 15900 17700 20150 23000 20°C’de iletken DC direnci Çal›flma Ak›m tafl›ma kapasitesi (30°C) kapasitesi Toprakta Havada yaklafl›k mH/km MF/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.29 220 240 260 220 220 240 240 260 280 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 250 250 250 250 250 250 250 250 250 220 220 240 240 260 260 280 300 320 250 250 250 250 250 250 250 250 250 240 240 260 260 260 280 300 300 320 cm Ω / km (max.) Çal›flma indüktans› yaklafl›k A A 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.40 154 181 220 263 298 332 374 431 608 172 205 253 307 352 397 453 529 608 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 154 181 220 263 298 332 374 431 608 172 205 253 307 352 397 453 529 608 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 154 181 220 263 298 332 374 431 608 172 205 253 307 352 397 453 529 608 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 608 172 205 253 307 352 397 453 529 608 81 ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI YXC7(Q)A2E YAPISI Bakır iletken (sınıf 2) ‹ç yarı iletken tabaka XLPE izole Dıfl yarı iletken tabaka Yarı iletken suda fliflen bant Konsantrik iletken Bakır bant Su tutucu bant Kopolimerli alüminyum bant Polietilen dıfl kılıf 1 2 3 4 5 6 7 8 9 10 10 9 8 7 6 5 4 3 2 1 ÖZELL‹KLER Tip Standartlar Anma Gerilimi : YXC7(Q)A2E (2XS(FL)2Y) : IEC 60840 Test Standardı : Uo/U=26/45 kV Uo/U=38/66 kV Uo/U=64/100 kV Uo/U=89/154 kV C Kullan›ld›¤› Yerler : Enerji üretim merkezlerinden, ulusal ve uluslararası enterkonnekte flebekelerin beslenmelerinde, kentlerin ana da¤ıtım sistemlerine ba¤lanmasında, güvenlik ve çevre koruması nedeni ile yüksek gerilim havai hatlarla flehir merkezlerine girilemeyen yerlerde, hariçte, kablo kanallarında ve toprak altında kullanılır. Ayrıca bu kablolar su geçirmez özelliktedir. C 90 r 250 -20 / +60 C r=15 x D o Kullanım Sıcaklı¤ı Maks. ‹flletme Sıcaklı¤ı Kısa Devre Sıcaklı¤ı Aleve Dayanıklılık IEC 60332 -1-2 Min. Bükülme Yarıçapı RoHS F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER 20°C’de iletken DC direnci Çal›flma indüktans› yaklafl›k Ω / km (max.) mH/km MF/km A 210 220 240 0.0601 0.0470 0.0366 0.37 0.35 0.33 0.20 0.22 0.24 598 673 759 250 250 250 240 240 240 0.0283 0.0221 0.0176 0.48 0.46 0.43 0.19 0.21 0.24 764 896 931 13300 15100 17200 250 250 250 260 260 280 0.0283 0.0221 0.0176 0.59 0.57 0.55 0.18 0.19 0.21 821 902 968 14200 15900 18100 250 250 250 260 280 280 0.0283 0.0221 0.0176 0.69 0.68 0.66 0.16 0.18 0.19 1080 1220 1355 Nominal kesit D›fl çap yaklafl›k Net a¤›rl›k Standart sevk Sevk yaklafl›k uzunlu¤u makara tipi mm2 mm kg/km m cm 53 62 67 5300 6100 7200 500 500 500 80 83 88 12200 14000 16000 89 93 97 95 99 103 Çal›flma Ak›m tafl›ma kapasitesi (30°C) kapasitesi Toprakta yaklafl›k 26/45 (52) kV 1x300/35 rm 1x400/35 rm 1x500/50 rm 38/66 (76) kV 1x630/135 rm 1x800/135 rm 1x1000/135 rm 64/110 (123) kV 1x630/135 rm 1x800/135 rm 1x1000/135 rm 89/154 (175) kV 1x630/135 rm 1x800/135 rm 1x1000/135 rm • Bu tür kabloların konstrüksiyonları proje bazında hazırlanmaktadır. Detaylı bilgi için firmamızla temas kurunuz. 82 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSY N2XS(F)2Y NA2XS(F)2Y CU/XLPE/SC/AWA/PVC N2XSEY N2XSEYFGY N2XSEYBY N2XSEYRY 2XS(FL)2Y MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSY CONSTRUCTION 1 2 3 4 5 6 7 8 Copper conductor (class 2) Inner semi conductive layer XLPE insulation Outer semi conductive layer Semi conductive crepe paper Concentric conductor Copper tape PVC outer sheath 8 7 6 5 4 3 2 1 SPECIFICATIONS Code Standards Rated voltage : N2XSY : VDE 0273 IEC 60502-2 : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Application : On this cable, electrical losses are minimized. Used for supplying power for populated and industrial regions, networks having voltage increase risk; can be installed in underground, indoor, outdoor and also in cable channel applications. C 90 r 250 -20 / +60 C r=15 x D o Temperature Range Max. Operation Temperature Short Circuit Temperature Flame Retardant IEC 60332 -1-2 Min. Bending Radius RoHS PHYSICAL AND ELECTRICAL PROPERTIES Overall Net weight Delivery drum Conductor DC Operating Nominal resistance type for inductance cross-section diameter approx. at 20°C approx. 1000 m. cable approx mm2 mm kg/km m Ω / km (max.) 6/10 (12) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 22 23 25 27 28 30 31 34 37 40 44 800 940 1160 1420 1670 2060 2400 2970 3650 4550 5650 120 130 140 140 150 150 160 180 180 200 220 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 66 mH/km mH/km 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.53 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.28 Operating capacity approx MF/km 0.22 0.24 0.28 0.31 0.33 0.36 0.40 0.45 0.51 0.57 0.63 Current carrying capacity in (30°C) Earth Air A A A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSY PHYSICAL AND ELECTRICAL PROPERTIES Overall Net weight Delivery drum Conductor DC Operating Nominal resistance type for inductance cross-section diameter approx. at 20°C approx. 1000 m. cable approx mm2 mm 8.7/15 (17.5) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 24 26 27 29 31 32 34 36 39 43 46 12/20 (24) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 26 28 30 31 33 35 36 39 42 45 49 kg/km 875 1020 1240 1520 1770 2160 2520 3090 3780 4690 5780 960 1100 1350 1620 1900 2275 2650 3250 3960 4870 5950 m Ω / km (max.) 130 140 140 150 160 160 180 180 200 220 220 140 150 150 160 160 180 180 200 200 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 mH/km mH/km 0.75 0.73 0.70 0.66 0.64 0.63 0.61 0.58 0.57 0.55 0.53 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.54 0.44 0.42 0.40 0.37 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.29 Operating capacity approx MF/km 0.18 0.19 0.22 0.25 0.27 0.29 0.31 0.35 0.40 0.44 0.49 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 0.37 0.41 Current carrying capacity in (30°C) Earth Air A A A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 18/30 (36 )kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 32 33 35 37 39 40 42 44 47 50 54 1200 1350 1620 1900 2200 2600 3000 3600 4300 5270 6400 160 160 180 180 200 200 200 220 220 240 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.43 0.42 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.30 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 0.28 0.36 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 20.3/35 (42)kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 34 35 37 39 41 42 44 46 49 53 56 1300 1500 1750 2050 2350 2750 3100 3700 4480 5420 6550 180 180 180 200 200 200 220 220 240 260 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.77 0.75 0.71 0.68 0.66 0.64 0.62 0.60 0.59 0.57 0.55 0.51 0.42 0.40 0.38 0.36 0.35 0.39 0.37 0.36 0.35 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.18 0.20 0.23 0.25 0.28 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1020 198 238 296 361 417 473 543 641 735 845 942 67 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XS(F)2Y CONSTRUCTION Copper conductor (class 2) Inner semi conductive layer XLPE insulation Outer semi conductive layer Semi conductive water blocking tape Concentric conductor Copper tape Water Swelling tape PE outer sheath 1 2 3 4 5 6 7 8 9 9 8 7 6 5 4 3 2 1 SPECIFICATIONS Code Standards Rated voltage : N2XS(F)2Y : VDE 0273 IEC 60502-2 : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Application : On this cable, electrical losses are minimized. Used for supplying power for populated and industrial regions, networks having voltage increase risk; can be installed in underground, indoor, outdoor and also in cable channel applications.These cables can also be used in humid and wet applications. C 90 r 250 -20 / +60 C r=15 x D o Temperature Range Max. Operation Temperature Short Circuit Temperature Flame Retardant IEC 60332 -1-2 Min. Bending Radius RoHS PHYSICAL AND ELECTRICAL PROPERTIES Overall Net weight Delivery drum Conductor DC Operating Nominal resistance type for inductance cross-section diameter approx. at 20°C approx. 1000 m. cable approx mm2 mm kg/km m Ω / km (max.) mH/km mH/km Operating capacity approx MF/km Current carrying capacity in (30°C) Earth Air A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 A A 6/10 (12) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 68 23 24 26 28 30 31 32 35 38 41 45 800 940 1160 1420 1670 2060 2400 2970 3650 4550 5650 130 130 140 150 150 160 160 180 200 200 220 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.53 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.28 0.22 0.24 0.28 0.31 0.33 0.36 0.40 0.45 0.51 0.57 0.63 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XS(F)2Y PHYSICAL AND ELECTRICAL PROPERTIES Overall Net weight Delivery drum Conductor DC Operating Nominal resistance type for inductance cross-section diameter approx. at 20°C approx. 1000 m. cable approx mm2 mm kg/km m Ω / km (max.) mH/km mH/km Operating capacity approx MF/km Current carrying capacity in (30°C) Earth Air A A A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 8.7/15 (17.5) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 25 27 28 30 31 33 34 37 40 43 47 875 1020 1240 1520 1770 2160 2520 3090 3780 4690 5780 140 140 150 150 160 160 180 180 200 220 220 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 12/20 (24) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 27 28 30 32 34 35 37 39 42 45 49 960 1100 1350 1620 1900 2275 2650 3250 3960 4870 5950 140 150 150 160 180 180 180 200 200 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.54 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.29 18/30 (36) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 33 34 36 37 39 40 42 45 48 51 55 160 180 180 180 200 200 200 220 240 260 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.75 0.72 0.69 0.69 0.64 0.62 0.60 0.58 0.56 0.53 0.42 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.30 20.3/35 (42) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16rm 1x150/25rm 1x185/25rm 1x240/25rm 1x300/25rm 1x400/35rm 1x500/35rm 35 36 38 39 41 43 44 47 50 53 57 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.77 0.75 0.71 0.68 0.66 0.64 0.62 0.60 0.59 0.57 0.55 0.51 0.42 0.40 0.38 0.36 0.35 0.39 0.37 0.36 0.35 0.33 1200 1350 1620 1900 2200 2600 3000 3600 4300 5270 6400 1300 1500 1750 2050 2350 2750 3100 3700 4480 5420 6550 180 180 200 200 200 220 220 220 240 260 260 0.75 0.73 0.70 0.66 0.64 0.63 0.61 0.58 0.57 0.55 0.53 0.44 0.42 0.40 0.37 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.19 0.21 0.23 0.26 0.28 0.30 0.33 0.37 0.40 0.44 0.49 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 0.37 0.41 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 0.28 0.30 0.11 0.12 0.14 0.15 0.16 0.17 0.18 0.20 0.23 0.25 0.28 69 MEDIUM AND HIGH VOLTAGE POWER CABLES NA2XS(F)2Y CONSTRUCTION Aluminium conductor (class 2) Inner semi conductive layer XLPE insulation Outer semi conductive layer Semi conductive water blocking tape Concentric conductor Copper tape Water Swelling tape PE outer sheath 1 2 3 4 5 6 7 8 9 9 8 7 6 5 4 3 2 1 SPECIFICATIONS Code Standards Rated voltage : NA2XS(F)2Y : VDE 0273 IEC 60502-2 : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Application : On this cable, electrical losses are minimized. Used for supplying power for populated and industrial regions, networks having voltage increase risk; can be installed in underground, indoor, outdoor and also in cable channel applications.These cables can also be used in humid and wet applications. C 90 r 250 -20 / +60 C r=15 x D o Temperature Range Max. Operation Temperature Short Circuit Temperature Flame Retardant IEC 60332 -1-2 Min. Bending Radius RoHS PHYSICAL AND ELECTRICAL PROPERTIES Overall Net weight Delivery drum Conductor DC Operating Nominal resistance type for inductance cross-section diameter approx. at 20°C approx. 1000 m. cable approx mm2 mm kg/km m Ω / km (max.) mH/km mH/km Operating capacity approx MF/km Current carrying capacity in (30°C) Earth Air A A A 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 A 6/10 (12) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 70 23 24 26 28 29 31 33 35 37 41 44 600 670 765 870 995 1200 1350 1580 1800 2200 2650 130 130 140 150 150 160 160 180 200 200 220 0.641 0.443 0.320 0.253 0.206 0.206 0.164 0.125 0.100 0.0778 0.0605 0.78 0.73 0.69 0.66 0.64 0.62 0.61 0.58 0.56 0.55 0.53 0.43 0.41 0.38 0.36 0.35 0.34 0.33 0.32 0.31 0.30 0.29 0.23 0.24 0.27 0.30 0.33 0.36 0.39 0.44 0.48 0.53 0.59 122 144 176 210 240 267 303 351 397 451 502 MEDIUM AND HIGH VOLTAGE POWER CABLES NA2XS(F)2Y PHYSICAL AND ELECTRICAL PROPERTIES Overall Net weight Delivery drum Conductor DC Operating Nominal resistance type for inductance cross-section diameter approx. at 20°C approx. 1000 m. cable approx mm2 8.7/15 (17.5) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 12/20 (24) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 18/30 (36) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 20.3/35 (42) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16rm 1x150/25rm 1x185/25rm 1x240/25rm 1x300/25rm 1x400/35rm 1x500/35rm mm kg/km m Ω / km (max.) mH/km mH/km 0.45 0.43 0.40 0.38 0.37 0.35 0.34 0.33 0.32 0.31 0.30 Current carrying capacity in (30°C) Earth Air A A A A 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 122 144 176 210 240 267 303 351 397 451 502 0.14 0.17 0.19 0.21 0.23 0.25 0.27 0.30 0.32 0.35 0.37 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 122 144 176 210 240 267 303 351 397 451 502 MF/km 25 26 28 30 31 33 35 37 40 43 46 700 770 850 1000 1100 1300 1500 1700 1950 2400 2800 140 140 150 150 160 160 180 180 200 220 220 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 27 29 30 32 34 35 37 40 42 45 48 800 850 950 1100 1200 1500 1600 1850 2100 2550 2950 140 150 150 160 180 180 180 200 200 220 240 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 0.75 0.72 0.69 0.66 0.64 0.62 0.59 0.57 0.55 0.53 0.51 33 34 36 37 39 41 42 45 47 50 54 1050 1100 1250 1360 1550 1750 1950 2200 2450 2950 3450 160 180 180 180 200 200 200 220 240 260 260 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 0.74 0.71 0.68 0.64 0.62 0.59 0.57 0.55 0.53 0.51 0.49 0.49 0.47 0.45 0.42 0.41 0.40 0.38 0.37 0.35 0.34 0.33 0.11 0.13 0.15 0.16 0.17 0.19 0.20 0.22 0.24 0.26 0.28 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 122 144 176 210 240 267 303 351 397 451 502 35 36 38 40 41 43 45 47 49 53 56 1150 1250 1400 1500 1650 1900 2100 2350 2650 3100 3600 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 0.74 0.71 0.68 0.64 0.62 0.59 0.57 0.55 0.53 0.51 0.49 0.49 0.47 0.45 0.42 0.41 0.40 0.38 0.37 0.35 0.34 0.33 0.11 0.13 0.15 0.16 0.17 0.19 0.20 0.22 0.24 0.26 0.28 134 157 192 229 260 288 324 373 419 466 526 129 152 186 221 252 281 317 367 414 470 542 123 146 178 213 242 271 307 356 402 457 508 122 144 176 210 240 267 303 351 397 451 502 180 180 200 200 200 220 220 220 240 260 260 0.76 0.73 0.70 0.67 0.65 0.63 0.61 0.59 0.57 0.55 0.53 Operating capacity approx 0.43 0.41 0.39 0.36 0.35 0.33 0.32 0.31 0.30 0.29 0.27 0.16 0.19 0.22 0.24 0.27 0.29 0.31 0.34 0.38 0.41 0.46 71 MEDIUM AND HIGH VOLTAGE POWER CABLES CU/XLPE/SC/AWA/PVC CONSTRUCTION 1 2 3 4 5 6 7 8 9 10 Copper conductor (class 2) Inner semi conductive layer XLPE insulation Outer semi conductive layer Semi conductive crepe paper Concentric conductor Copper tape PVC separation sheath Aluminium round wire PVC outer sheath 10 9 8 7 6 5 4 3 2 1 SPECIFICATIONS Code Standards Rated voltage : CU/XLPE / SC / AWA / PVC : BS 6622 IEC 60502-2 : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Application : On this cable, electrical losses are minimized. Used for supplying power for populated and industrial regions, networks having voltage increase risk; can be installed in underground, indoor, outdoor and also in cable channel applications. The armour in the structure makes the cable necessary where there is mechanical stress risk. C 90 r 250 -20 / +60 C r=15 x D o Temperature Range Max. Operation Temperature Short Circuit Temperature Flame Retardant IEC 60332 -1-2 Min. Bending Radius RoHS PHYSICAL AND ELECTRICAL PROPERTIES Overall Net weight Delivery drum Conductor DC Operating Nominal resistance type for inductance cross-section diameter approx. at 20°C approx. 1000 m. cable approx mm2 mm 6/10 (12)kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 28 29 31 32 35 36 38 41 44 48 51 72 kg/km 1150 1330 1600 1900 2300 2700 3050 3700 4450 5450 6600 m 150 150 160 160 180 180 200 200 220 240 260 Ω / km (max.) 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 mH/km mH/km 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.56 0.54 0.53 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.28 Operating capacity approx MF/km 0.22 0.24 0.28 0.31 0.33 0.36 0.40 0.45 0.51 0.57 0.63 Current carrying capacity in (30°C) Earth Air A A 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 A A 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 MEDIUM AND HIGH VOLTAGE POWER CABLES CU/XLPE/SC/AWA/PVC PHYSICAL AND ELECTRICAL PROPERTIES Overall Net weight Delivery drum Conductor DC Operating Nominal resistance type for inductance cross-section diameter approx. at 20°C approx. 1000 m. cable approx mm2 mm kg/km m Ω / km (max.) mH/km mH/km Operating capacity approx MF/km Current carrying capacity in (30°C) Earth Air A A A A 8.7/15 (17.5) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 30 31 34 36 37 39 41 43 46 50 54 1280 1450 1730 2050 2400 2820 3250 3850 4650 5600 6830 150 160 180 180 180 200 200 220 220 240 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.73 0.70 0.66 0.64 0.63 0.61 0.58 0.57 0.55 0.53 0.44 0.42 0.40 0.37 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.19 0.21 0.23 0.26 0.28 0.30 0.33 0.37 0.40 0.44 0.49 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 12/20 (24) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16 rm 1x150/25 rm 1x185/25 rm 1x240/25 rm 1x300/25 rm 1x400/35 rm 1x500/35 rm 32 34 36 38 40 41 43 46 49 52 56 1400 1600 1950 2300 2600 3020 3400 4050 4850 5850 7050 160 180 180 200 200 200 220 220 240 260 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.78 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.54 0.54 0.44 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.30 0.29 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 0.37 0.41 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 39 40 42 43 46 48 49 52 55 59 63 1850 2050 2350 2700 3160 3600 4020 4700 5500 6570 7850 200 200 200 220 220 240 240 260 260 260 280 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.75 0.72 0.69 0.66 0.64 0.62 0.60 0.58 0.58 0.56 0.43 0.42 0.40 0.38 0.36 0.35 0.34 0.33 0.31 0.31 0.30 0.30 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 0.28 0.30 172 203 246 293 332 366 410 470 524 572 632 166 196 239 285 323 361 406 469 526 590 658 238 286 356 434 500 559 637 745 846 938 1026 198 238 296 361 417 473 543 641 735 845 942 18/30 (36) kV 1x35/16 rm 1x50/16 rm 1x70/16 rm 1x95/16 rm 1x120/16rm 1x150/25rm 1x185/25rm 1x240/25rm 1x300/25rm 1x400/35rm 1x500/35rm 73 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSEY CONSTRUCTION 1 2 3 4 5 6 7 8 Copper conductor (class 2) Inner semi conductive layer XLPE insulation Outer semi conductive layer Semi conductive crepe paper Copper tape screen PP filler PVC outer sheath 8 7 6 5 4 3 2 1 SPECIFICATIONS Code Standards Rated voltage : N2XSEY : VDE 0273 : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Application : On this cable, electrical losses are minimized. Used for supplying power for populated and industrial regions, networks having voltage increase risk; can be installed in underground, indoor, outdoor and also in cable channel applications. The armour in the structure makes the cable necessary where there is mechanical stress risk. C 90 r 250 -20 / +60 C r=15 x D o Temperature Range Max. Operation Temperature Short Circuit Temperature Flame Retardant IEC 60332 -1-2 Min. Bending Radius RoHS PHYSICAL AND ELECTRICAL PROPERTIES Overall Nominal cross-section diameter approx. mm2 Net weight approx. Delivery Delivery drum Conductor DC Operating length resistance inductance type at 20°C approx Operating capacity approx Current carrying capacity in (30°C) Earth Air mm kg/km m cm Ω / km (max.) mH/km MF/km A A 43 46 49 53 57 61 64 69 74 2700 2950 3900 4950 5850 6900 7950 9400 10650 500 500 500 500 500 500 500 250 250 180 180 180 200 220 220 240 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.22 0.24 0.28 0.31 0.34 0.36 0.40 0.45 0.51 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 6/10 kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 74 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSEY PHYSICAL AND ELECTRICAL PROPERTIES Overall Nominal cross-section diameter approx. mm2 mm Net weight approx. kg/km Delivery Delivery drum Conductor DC Operating length resistance inductance type at 20°C approx m cm Ω / km (max.) Operating Current carrying capacity in (30°C) capacity Earth Air approx mH/km MF/km A A 8.7/15 (17.5) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16rm 3x150/25rm 3x185/25rm 3x240/25rm 3x300/25rm 49 51 55 59 63 66 69 74 79 3200 3600 4500 5450 6350 7250 8950 9500 1060 500 500 500 500 500 500 250 250 250 180 200 200 220 220 220 200 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.40 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 12/20 (24) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 52 54 58 62 65 69 72 78 83 3700 4300 5200 6250 7300 8450 9500 11900 13900 500 500 500 500 500 250 250 250 250 200 200 220 220 220 200 200 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.33 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 4900 5400 6500 7500 8650 9250 10100 12100 15150 500 500 250 250 250 250 250 250 250 200 220 220 220 220 240 240 240 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 18/30 (36) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 63 66 70 74 77 80 84 88 93 20.3/35 (42) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 68 71 75 78 82 85 88 94 98 5200 6250 7150 8300 9250 10050 11200 12500 15600 250 250 250 250 250 250 250 250 250 220 220 220 240 240 240 240 240 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 75 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSEYFGY CONSTRUCTION 1 2 3 4 5 6 7 8 9 10 11 Copper conductor (class 2) Inner semi conductive layer XLPE insulation Outer semi conductive layer Semi conductive crepe paper Copper tape screen PP filler PVC separation sheath Galvanized flat steel wire Galvanized steel tape PVC outer sheath 11 10 9 8 7 6 5 4 3 2 1 SPECIFICATIONS Code Standards Rated voltage : N2XSEYFGY : VDE 0273 : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Application : On this cable, electrical losses are minimized. Used for supplying power for populated and industrial regions, networks having voltage increase risk; can be installed in underground, indoor, outdoor and also in cable channel applications. The armour in the structure makes the cable necessary where there is mechanical stress risk. C 90 r 250 -20 / +60 C r=15 x D o Temperature Range Max. Operation Temperature Short Circuit Temperature Flame Retardant IEC 60332 -1-2 Mechanical Resistance Min. Bending Radius RoHS PHYSICAL AND ELECTRICAL PROPERTIES Overall Nominal cross-section diameter approx. mm2 Net weight approx. Delivery Delivery drum Conductor DC Operating length resistance inductance type at 20°C approx Operating capacity approx Current carrying capacity in (30°C) Earth Air mm kg/km m cm Ω / km (max.) mH/km MF/km A A 49 52 57 60 64 67 71 77 83 3640 4200 5150 6200 7150 8250 9600 10650 14050 500 500 500 500 500 500 500 250 250 200 210 220 220 240 240 260 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.22 0.24 0.28 0.31 0.34 0.36 0.40 0.45 0.51 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 6/10 kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 76 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSEYFGY PHYSICAL AND ELECTRICAL PROPERTIES Overall Nominal cross-section diameter approx. mm2 Net weight approx. Delivery Delivery drum Conductor DC Operating length resistance inductance type at 20°C approx mm kg/km m 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16rm 3x150/25rm 3x185/25rm 3x240/25rm 3x300/25rm 55 58 62 66 69 73 77 83 89 4200 4800 5750 6850 7850 8950 10300 12450 14900 500 500 500 500 250 250 250 250 250 12/20 (24) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 60 63 67 71 74 78 87 88 93 4750 5350 6350 7450 8450 9600 11000 13200 15700 500 500 500 500 250 250 250 250 250 72 75 79 83 86 90 94 100 106 6250 6900 7950 9100 10200 11400 12900 15200 17800 250 250 250 250 250 250 250 250 250 mH/km MF/km 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 220 220 240 260 210 220 240 240 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 210 220 220 240 240 260 260 280 300 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 cm Ω / km (max.) Operating Current carrying capacity in (30°C) capacity Earth Air approx A A 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.40 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.33 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 8.7/15 (17.5) kV 210 220 220 240 200 210 220 240 260 18/30 (36) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 20.3/35 (42) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 77 80 84 88 91 95 99 105 110 6900 7600 8650 9850 10950 12150 13700 16000 18550 250 250 250 250 250 250 250 250 250 220 220 240 240 260 260 280 300 300 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 77 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSEYBY CONSTRUCTION 1 2 3 4 5 6 7 8 9 10 Copper conductor (class 2) Inner semi conductive layer XLPE insulation Outer semi conductive layer Semi conductive crepe paper Copper tape screen PP filler PVC separation sheath Galvanized double steel tape PVC outer sheath 10 9 8 7 6 5 4 3 2 1 SPECIFICATIONS Code Standards Rated voltage : N2XSEYBY : VDE 0273 IEC 60502-2 : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Application : On this cable, electrical losses are minimized. Used for supplying power for populated and industrial regions, networks having voltage increase risk; can be installed in underground, indoor, outdoor and also in cable channel applications. The armour in the structure makes the cable necessary where there is mechanical stress risk. C 90 r 250 -20 / +60 C r=15 x D o Temperature Range Max. Operation Temperature Short Circuit Temperature Flame Retardant IEC 60332 -1-2 Mechanical Resistance Min. Bending Radius RoHS PHYSICAL AND ELECTRICAL PROPERTIES Overall Nominal cross-section diameter approx. mm2 mm 6/10 kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 78 49 52 57 60 64 67 71 77 84 Net weight approx. kg/km 3400 4000 4900 5900 6850 7900 9250 11300 14450 Delivery Delivery drum Conductor DC Operating length resistance inductance type at 20°C approx m Ω / km (max.) mH/km cm 500 500 500 500 500 500 500 250 250 200 210 220 220 240 240 260 220 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 Operating capacity approx MF/km 0.22 0.24 0.28 0.31 0.34 0.36 0.40 0.45 0.51 Current carrying capacity in (30°C) Earth Air A A 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSEYBY PHYSICAL AND ELECTRICAL PROPERTIES Overall Nominal cross-section diameter approx. mm2 Net weight Delivery length approx. Delivery drum Conductor DC Operating resistance inductance type at 20°C approx mm kg/km m cm Ω / km (max.) mH/km 55 58 62 66 69 73 77 84 90 3950 4550 5450 6500 7500 8600 9900 12800 15300 500 500 500 500 250 250 250 250 250 210 220 220 240 200 210 220 240 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.29 Operating capacity approx Current carrying capacity in (30°C) Earth Air A A 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.40 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 MF/km 8.7/15 (17.5) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 12/20 (24) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 60 62 67 70 74 77 83 89 95 4450 5050 6000 7100 8100 9200 11350 13600 16100 500 500 500 500 250 250 250 250 200 220 220 240 240 210 220 240 260 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.27 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 18/30 (36) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 72 75 79 84 88 91 95 101 107 5900 6500 7550 9500 10600 11800 13300 15600 18250 250 250 250 250 250 250 250 250 250 210 220 220 240 240 260 260 280 300 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 20.3/35 (42) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 77 80 85 89 93 96 100 106 112 6500 7200 9050 10250 11400 12600 14200 16500 19200 250 250 250 250 250 250 250 250 250 220 220 240 260 260 260 280 300 320 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 79 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSEYRY CONSTRUCTION 1 2 3 4 5 6 7 8 9 10 Copper conductor (class 2) Inner semi conductive layer XLPE insulation Outer semi conductive layer Semi conductive crepe paper Copper tape screen PP filler PVC separation sheath Galvanized round steel wire PVC outer sheath 10 9 7 6 5 4 8 3 2 1 SPECIFICATIONS Code Standards Rated voltage : N2XSEYRY : VDE 0273 : Uo/U=6/10 kV Uo/U=8.7/15 kV Uo/U=12/20 kV Uo/U=18/30 kV Uo/U=20.3/35 kV C Application : On this cable, electrical losses are minimized. Used for supplying power for populated and industrial regions, networks having voltage increase risk; can be installed in underground, indoor, outdoor and also in cable channel applications. The armour in the structure make the cable necessary where there is mechanical stress risk. C 90 r 250 -20 / +60 C r=15 x D o Temperature Range Max. Operation Temperature Short Circuit Temperature Flame Retardant IEC 60332 -1-2 Mechanical Resistance Min. Bending Radius RoHS PHYSICAL AND ELECTRICAL PROPERTIES Overall Nominal cross-section diameter approx. mm2 Net weight Delivery length approx. mm kg/km m 53 56 60 64 68 71 76 83 88 5000 5650 6750 7850 9000 10100 12450 14800 17450 500 500 500 500 500 500 250 250 250 Delivery drum Conductor DC Operating resistance inductance type at 20°C approx cm Ω / km (max.) mH/km Operating capacity approx MF/km Current carrying capacity in (30°C) Earth Air A A 6/10 kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 80 210 220 220 240 240 260 220 240 240 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.22 0.24 0.28 0.31 0.34 0.36 0.40 0.45 0.51 154 181 220 263 298 332 374 431 492 172 205 253 307 352 397 453 529 608 MEDIUM AND HIGH VOLTAGE POWER CABLES N2XSEYRY PHYSICAL AND ELECTRICAL PROPERTIES Overall Nominal cross-section diameter approx. Net weight approx. Delivery Delivery drum Conductor DC Operating length resistance inductance type at 20°C approx Operating capacity approx Current carrying capacity in (30°C) Earth Air A A 0.18 0.20 0.22 0.25 0.27 0.29 0.32 0.35 0.40 154 181 220 263 298 332 374 431 608 172 205 253 307 352 397 453 529 608 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.16 0.18 0.20 0.22 0.24 0.26 0.28 0.31 0.34 154 181 220 263 298 332 374 431 608 172 205 253 307 352 397 453 529 608 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.13 0.14 0.16 0.17 0.18 0.20 0.21 0.23 0.25 154 181 220 263 298 332 374 431 608 172 205 253 307 352 397 453 529 608 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.47 0.45 0.42 0.40 0.39 0.37 0.36 0.34 0.33 0.11 0.12 0.14 0.15 0.16 0.17 0.19 0.21 0.23 154 181 220 263 298 332 374 431 608 172 205 253 307 352 397 453 529 608 mm2 mm kg/km m cm Ω / km (max.) mH/km MF/km 8.7/15 (17.5) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 58 61 66 69 74 78 82 88 94 5750 6400 7500 8700 9800 11800 13400 15800 18500 500 500 500 500 500 250 250 250 250 220 220 240 240 260 220 240 240 260 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.39 0.37 0.35 0.33 0.32 0.31 0.30 0.29 0.29 12/20 (24) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 63 66 71 76 80 83 86 93 99 6450 7150 8200 10300 11450 12700 14200 16700 19500 500 500 500 250 250 250 250 250 250 220 240 260 220 220 240 240 260 280 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 18/30 (36) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16rm 3x150/25rm 3x185/25rm 3x240/25rm 3x300/25 rm 77 80 84 88 92 95 99 105 111 9100 9900 11100 12500 13700 15050 16700 19250 22100 250 250 250 250 250 250 250 250 250 220 220 240 240 260 260 280 300 320 20.3/35 (42) kV 3x35/16 rm 3x50/16 rm 3x70/16 rm 3x95/16 rm 3x120/16 rm 3x150/25 rm 3x185/25 rm 3x240/25 rm 3x300/25 rm 82 84 89 93 96 99 104 109 115 9900 10700 11950 13300 14600 15900 17700 20150 23000 250 250 250 250 250 250 250 250 250 240 240 260 260 260 280 300 300 320 81 MEDIUM AND HIGH VOLTAGE POWER CABLES 2XS(FL)2Y CONSTRUCTION 1 2 3 4 5 6 7 8 9 10 Copper conductor (class 2) Inner semi conductive layer XLPE insulation Outer semi conductive layer Semi conductive water blocking tape Concentric conductor Copper tape Water swelling tape Copolimer aluminium tape Polyethylene outer sheath 10 9 8 7 6 5 4 3 2 1 SPECIFICATIONS Code Standards Rated voltage : 2XS(FL)2Y : IEC 60840 Test Standards : Uo/U=26/45 kV Uo/U=38/66 kV Uo/U=64/100 kV Uo/U=89/154 kV C Application : Used to transmit energy from power centres to national and international interconnection networks, at connection of cities to central distribution systems, also used in special premises where over head lines are not permitted such as city centres due to safety and environmental regulations. Additionally, this cable is completely waterproof. C 90 r 250 -20 / +60 C r=15 x D o Temperature Range Max. Operation Temperature Short Circuit Temperature Flame Retardant IEC 60332 -1-2 Min. Bending Radius RoHS PHYSICAL AND ELECTRICAL PROPERTIES Overall Nominal cross-section diameter approx. mm2 Net weight approx. Delivery Delivery drum Conductor DC Operating length resistance inductance type at 20°C approx mm kg/km m cm 53 62 67 5300 6100 7200 500 500 500 80 83 88 12200 14000 16000 89 93 97 95 99 103 Operating capacity approx Current carrying capacity in (30°C) Earth Ω / km (max.) mH/km MF/km A 210 220 240 0.0601 0.0470 0.0366 0.37 0.35 0.33 0.20 0.22 0.24 598 673 759 250 250 250 240 240 240 0.0283 0.0221 0.0176 0.48 0.46 0.43 0.19 0.21 0.24 764 896 931 13300 15100 17200 250 250 250 260 260 280 0.0283 0.0221 0.0176 0.59 0.57 0.55 0.18 0.19 0.21 821 902 968 14200 15900 18100 250 250 250 260 280 280 0.0283 0.0221 0.0176 0.69 0.68 0.66 0.16 0.18 0.19 1080 1220 1355 26/45 (52) kV 1x300/35 rm 1x400/35 rm 1x500/50 rm 38/66 (76) kV 1x630/135 rm 1x800/135 rm 1x1000/135 rm 64/110 (123) kV 1x630/135 rm 1x800/135 rm 1x1000/135 rm 89/154 (175) kV 1x630/135 rm 1x800/135 rm 1x1000/135 rm • Since construction of these cables are individually prepared on project basis,please contact with our company for further information. 82
© Copyright 2024 Paperzz