Muhtelif Ürünler - As Sct Otomotiv

ORTA VE YÜKSEK
GER‹L‹M ENERJ‹ KABLOLARI
YXC7V
YXC7(Q)E
YAXC7(Q)E
YXC7VY2V
YXC8V
YXC8VZ3V
YXC8VZ4V
YXC8VZ2V
YXC7(Q)A2E
(N2XSY)
(N2XS(F)2Y)
(NA2XS(F)2Y)
(N2XSYB(AL)Y)
(N2XSEY)
(N2XSEYFGY)
(N2XSEYBY)
(N2XSEYRY)
(2XS(FL)2Y)
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC7V
YAPISI
1
2
3
4
5
6
7
8
Bakır iletken (sınıf 2)
‹ç yarı iletken tabaka
XLPE izole
Dıfl yarı iletken tabaka
Yarı iletken krep ka¤ıdı
Konsantrik iletken
Bakır bant
PVC dıfl kılıf
8
7
6
5
4
3
2
1
ÖZELL‹KLER
Tip
Standartlar
Anma Gerilimi
: YXC7V (N2XSY)
: TS IEC 60502-2 - TSEK
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Kullan›ld›¤› Yerler
:
Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin
ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde,
yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında
veya kablo kanallarında kullanılır.
C
90
r
250
-20 / +60 C
r=15 x D
o
Kullanım Sıcaklı¤ı
Maks. ‹flletme Sıcaklı¤ı
Kısa Devre Sıcaklı¤ı
Aleve Dayanıklılık
IEC 60332 -1-2
Min. Bükülme Yarıçapı
RoHS
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
m. kablo 20°C’de
D›fl çap Net a¤›rl›k 1000
için sevk
iletken
yaklafl›k yaklafl›k
makara tipi
DC direnci
mm2
mm
kg/km
m
Ω / km (max.)
6/10 (12) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
22
23
25
27
28
30
31
34
37
40
44
800
940
1160
1420
1670
2060
2400
2970
3650
4550
5650
120
130
140
140
150
150
160
180
180
200
220
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
66
Çal›flma
indüktans›
yaklafl›k
mH/km mH/km
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.53
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.28
Çal›flma
kapasitesi
yaklafl›k
MF/km
0.22
0.24
0.28
0.31
0.33
0.36
0.40
0.45
0.51
0.57
0.63
Ak›m tafl›ma kapasitesi (30°C)
Toprakta
Havada
A
A
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC7V
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
m. kablo 20°C’de
D›fl çap Net a¤›rl›k 1000
için sevk
iletken
yaklafl›k yaklafl›k
makara tipi
DC direnci
mm2
mm
8.7/15 (17.5) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
24
26
27
29
31
32
34
36
39
43
46
12/20 (24) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
26
28
30
31
33
35
36
39
42
45
49
kg/km
875
1020
1240
1520
1770
2160
2520
3090
3780
4690
5780
960
1100
1350
1620
1900
2275
2650
3250
3960
4870
5950
m
Ω / km (max.)
130
140
140
150
160
160
180
180
200
220
220
140
150
150
160
160
180
180
200
200
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
Çal›flma
indüktans›
yaklafl›k
mH/km mH/km
0.75
0.73
0.70
0.66
0.64
0.63
0.61
0.58
0.57
0.55
0.53
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.54
0.44
0.42
0.40
0.37
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.29
Çal›flma
kapasitesi
yaklafl›k
MF/km
0.18
0.19
0.22
0.25
0.27
0.29
0.31
0.35
0.40
0.44
0.49
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
Ak›m tafl›ma kapasitesi (30°C)
Toprakta
Havada
A
A
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
18/30 (36 )kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
32
33
35
37
39
40
42
44
47
50
54
1200
1350
1620
1900
2200
2600
3000
3600
4300
5270
6400
160
160
180
180
200
200
200
220
220
240
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.43
0.42
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.30
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
0.28
0.36
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
20.3/35 (42)kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
34
35
37
39
41
42
44
46
49
53
56
1300
1500
1750
2050
2350
2750
3100
3700
4480
5420
6550
180
180
180
200
200
200
220
220
240
260
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.77
0.75
0.71
0.68
0.66
0.64
0.62
0.60
0.59
0.57
0.55
0.51
0.42
0.40
0.38
0.36
0.35
0.39
0.37
0.36
0.35
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.18
0.20
0.23
0.25
0.28
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
67
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC7(Q)E
YAPISI
1
2
3
4
5
6
7
8
9
Bakır iletken (sınıf 2)
‹ç yarı iletken tabaka
XLPE izole
Dıfl yarı iletken tabaka
Yarı iletken su tutucu bant
Konsantrik iletken
Bakır bant
Su tutucu bant
PE dıfl kılıf
9
8 7
6 5
4
3
2
1
ÖZELL‹KLER
Tip
Standartlar
Anma Gerilimi
: YXC7(Q)E (N2XS(F)2Y)
: TS IEC 60502-2 - TSEK
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Kullan›ld›¤› Yerler
:
Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin
ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde,
yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında
veya kablo kanallarında kullanılır. Aynı zamanda yapısındaki
su tutucu bantlar sayesinde nemli ve sulu ortamlarda da
kullanılabilir.
C
90
r
250
-20 / +60 C
r=15 x D
o
Kullanım Sıcaklı¤ı
Maks. ‹flletme Sıcaklı¤ı
Kısa Devre Sıcaklı¤ı
Aleve Dayanıklılık
IEC 60332 -1-2
Min. Bükülme Yarıçapı
RoHS
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
mm2
m. kablo 20°C’de
D›fl çap Net a¤›rl›k 1000
için sevk
iletken
yaklafl›k yaklafl›k
makara tipi
DC direnci
mm
kg/km
m
Ω / km (max.)
Çal›flma
indüktans›
yaklafl›k
mH/km mH/km
Çal›flma
kapasitesi
yaklafl›k
MF/km
Ak›m tafl›ma kapasitesi (30°C)
Toprakta
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
Havada
A
A
6/10 (12) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
68
23
24
26
28
30
31
32
35
38
41
45
800
940
1160
1420
1670
2060
2400
2970
3650
4550
5650
130
130
140
150
150
160
160
180
200
200
220
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.53
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.28
0.22
0.24
0.28
0.31
0.33
0.36
0.40
0.45
0.51
0.57
0.63
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC7(Q)E
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
mm2
m. kablo 20°C’de
D›fl çap Net a¤›rl›k 1000
için sevk
iletken
yaklafl›k yaklafl›k
makara tipi
DC direnci
mm
kg/km
m
Ω / km (max.)
Çal›flma
indüktans›
yaklafl›k
mH/km mH/km
Çal›flma
kapasitesi
yaklafl›k
MF/km
Ak›m tafl›ma kapasitesi (30°C)
Toprakta
Havada
A
A
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
8.7/15 (17.5) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
25
27
28
30
31
33
34
37
40
43
47
875
1020
1240
1520
1770
2160
2520
3090
3780
4690
5780
140
140
150
150
160
160
180
180
200
220
220
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
12/20 (24) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
27
28
30
32
34
35
37
39
42
45
49
960
1100
1350
1620
1900
2275
2650
3250
3960
4870
5950
140
150
150
160
180
180
180
200
200
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.54
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.29
18/30 (36) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
33
34
36
37
39
40
42
45
48
51
55
160
180
180
180
200
200
200
220
240
260
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.75
0.72
0.69
0.69
0.64
0.62
0.60
0.58
0.56
0.53
0.42
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.30
20.3/35 (42) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16rm
1x150/25rm
1x185/25rm
1x240/25rm
1x300/25rm
1x400/35rm
1x500/35rm
35
36
38
39
41
43
44
47
50
53
57
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.77
0.75
0.71
0.68
0.66
0.64
0.62
0.60
0.59
0.57
0.55
0.51
0.42
0.40
0.38
0.36
0.35
0.39
0.37
0.36
0.35
0.33
1200
1350
1620
1900
2200
2600
3000
3600
4300
5270
6400
1300
1500
1750
2050
2350
2750
3100
3700
4480
5420
6550
180
180
200
200
200
220
220
220
240
260
260
0.75
0.73
0.70
0.66
0.64
0.63
0.61
0.58
0.57
0.55
0.53
0.44
0.42
0.40
0.37
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.19
0.21
0.23
0.26
0.28
0.30
0.33
0.37
0.40
0.44
0.49
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
0.28
0.30
0.11
0.12
0.14
0.15
0.16
0.17
0.18
0.20
0.23
0.25
0.28
69
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YAXC7(Q)E
YAPISI
1
2
3
4
5
6
7
8
9
Alüminyum iletken (sınıf 2)
‹ç yarı iletken tabaka
XLPE izole
Dıfl yarı iletken tabaka
Yarı iletken su tutucu bant
Konsantrik iletken
Bakır bant
Su tutucu bant
PE dıfl kılıf
9
8 7
6 5
4
3
2
1
ÖZELL‹KLER
Tip
Standartlar
Anma Gerilimi
: YAXC7(Q)E (NA2XS(F)2Y)
: TS IEC 60502-2 - TSEK
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Kullan›ld›¤› Yerler
:
Bu kabloların elektriksel kayıpları küçüktür. Endüstri bölgelerinin
ve yerleflim merkezlerinin elektrik enerjisi ile beslenmesinde,
yük artıflı beklenen flebekelerde, dahilde, hariçte, toprak altında
veya kablo kanallarında kullanılır. Aynı zamanda yapısındaki
su tutucu bantlar sayesinde nemli ve sulu ortamlarda da
kullanılabilir.
C
90
r
250
-20 / +60 C
r=15 x D
o
Kullanım Sıcaklı¤ı
Maks. ‹flletme Sıcaklı¤ı
Kısa Devre Sıcaklı¤ı
Aleve Dayanıklılık
IEC 60332 -1-2
Min. Bükülme Yarıçapı
RoHS
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
mm2
m. kablo 20°C’de
D›fl çap Net a¤›rl›k 1000
için sevk
iletken
yaklafl›k yaklafl›k
makara tipi
DC direnci
mm
kg/km
m
Ω / km (max.)
Çal›flma
indüktans›
yaklafl›k
mH/km mH/km
Çal›flma
kapasitesi
yaklafl›k
MF/km
Ak›m tafl›ma kapasitesi (30°C)
Toprakta
Havada
A
A
A
A
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
122
144
176
210
240
267
303
351
397
451
502
6/10 (12) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
70
23
24
26
28
29
31
33
35
37
41
44
600
670
765
870
995
1200
1350
1580
1800
2200
2650
130
130
140
150
150
160
160
180
200
200
220
0.641
0.443
0.320
0.253
0.206
0.206
0.164
0.125
0.100
0.0778
0.0605
0.78
0.73
0.69
0.66
0.64
0.62
0.61
0.58
0.56
0.55
0.53
0.43
0.41
0.38
0.36
0.35
0.34
0.33
0.32
0.31
0.30
0.29
0.23
0.24
0.27
0.30
0.33
0.36
0.39
0.44
0.48
0.53
0.59
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YAXC7(Q)E
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
mm2
m. kablo 20°C’de
D›fl çap Net a¤›rl›k 1000
için sevk
iletken
yaklafl›k yaklafl›k
makara tipi
DC direnci
mm
kg/km
m
Ω / km (max.)
Çal›flma
indüktans›
yaklafl›k
mH/km mH/km
Çal›flma
kapasitesi
yaklafl›k
Ak›m tafl›ma kapasitesi (30°C)
Toprakta
Havada
A
A
A
0.16
0.19
0.22
0.24
0.27
0.29
0.31
0.34
0.38
0.41
0.46
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
122
144
176
210
240
267
303
351
397
451
502
0.14
0.17
0.19
0.21
0.23
0.25
0.27
0.30
0.32
0.35
0.37
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
122
144
176
210
240
267
303
351
397
451
502
MF/km
A
8.7/15 (17.5) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
25
26
28
30
31
33
35
37
40
43
46
700
770
850
1000
1100
1300
1500
1700
1950
2400
2800
140
140
150
150
160
160
180
180
200
220
220
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
12/20 (24) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
27
29
30
32
34
35
37
40
42
45
48
800
850
950
1100
1200
1500
1600
1850
2100
2550
2950
140
150
150
160
180
180
180
200
200
220
240
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.75
0.72
0.69
0.66
0.64
0.62
0.59
0.57
0.55
0.53
0.51
18/30 (36) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
33
34
36
37
39
41
42
45
47
50
54
1050
1100
1250
1360
1550
1750
1950
2200
2450
2950
3450
160
180
180
180
200
200
200
220
240
260
260
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.74
0.71
0.68
0.64
0.62
0.59
0.57
0.55
0.53
0.51
0.49
0.49
0.47
0.45
0.42
0.41
0.40
0.38
0.37
0.35
0.34
0.33
0.11
0.13
0.15
0.16
0.17
0.19
0.20
0.22
0.24
0.26
0.28
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
122
144
176
210
240
267
303
351
397
451
502
20.3/35 (42) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16rm
1x150/25rm
1x185/25rm
1x240/25rm
1x300/25rm
1x400/35rm
1x500/35rm
35
36
38
40
41
43
45
47
49
53
56
1150
1250
1400
1500
1650
1900
2100
2350
2650
3100
3600
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.74
0.71
0.68
0.64
0.62
0.59
0.57
0.55
0.53
0.51
0.49
0.49
0.47
0.45
0.42
0.41
0.40
0.38
0.37
0.35
0.34
0.33
0.11
0.13
0.15
0.16
0.17
0.19
0.20
0.22
0.24
0.26
0.28
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
122
144
176
210
240
267
303
351
397
451
502
180
180
200
200
200
220
220
220
240
260
260
0.76
0.73
0.70
0.67
0.65
0.63
0.61
0.59
0.57
0.55
0.53
0.45
0.43
0.40
0.38
0.37
0.35
0.34
0.33
0.32
0.31
0.30
0.43
0.41
0.39
0.36
0.35
0.33
0.32
0.31
0.30
0.29
0.27
71
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC7VY2V
YAPISI
1
2
3
4
5
6
7
8
9
10
Bakır iletken (sınıf 2)
‹ç yarı iletken tabaka
XLPE izole
Dıfl yarı iletken tabaka
Yarı iletken krep ka¤ıdı
Konsantrik iletken
Bakır bant
PVC ayırıcı kılıf
Alüminyum yuvarlak tel
PVC dıfl kılıf
10
9 8 7 6
5
4
3
2
1
ÖZELL‹KLER
Tip
Standartlar
Anma Gerilimi
: YXC7VY2V (N2XSYR(AL)Y)
: TS IEC 60502-2 - TSEK
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
C
90
Kullan›ld›¤› Yerler
:
Mekanik zorlanmalara karflı yapısındaki zırh sayesinde
mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür.
Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi
ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde,
hariçte, toprak altında veya kablo kanallarında kullanılır.
r
250
-20 / +60 C
r=15 x D
o
Kullanım Sıcaklı¤ı
Maks. ‹flletme Sıcaklı¤ı
Kısa Devre Sıcaklı¤ı
Aleve Dayanıklılık
IEC 60332 -1-2
Min. Bükülme Yarıçapı
RoHS
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
m. kablo 20°C’de
D›fl çap Net a¤›rl›k 1000
için sevk
iletken
yaklafl›k yaklafl›k
makara tipi
DC direnci
mm2
mm
6/10 (12)kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
28
29
31
32
35
36
38
41
44
48
51
72
kg/km
1150
1330
1600
1900
2300
2700
3050
3700
4450
5450
6600
m
150
150
160
160
180
180
200
200
220
240
260
Ω / km (max.)
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
Çal›flma
indüktans›
yaklafl›k
mH/km mH/km
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.53
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.28
Çal›flma
kapasitesi
yaklafl›k
MF/km
0.22
0.24
0.28
0.31
0.33
0.36
0.40
0.45
0.51
0.57
0.63
Ak›m tafl›ma kapasitesi (30°C)
Toprakta
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
Havada
A
A
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC7VY2V
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
mm2
m. kablo 20°C’de
D›fl çap Net a¤›rl›k 1000
için sevk
iletken
yaklafl›k yaklafl›k
makara tipi
DC direnci
mm
kg/km
m
Ω / km (max.)
Çal›flma
indüktans›
yaklafl›k
mH/km mH/km
Çal›flma
kapasitesi
yaklafl›k
MF/km
Ak›m tafl›ma kapasitesi (30°C)
Toprakta
A
A
Havada
A
A
8.7/15 (17.5) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
30
31
34
36
37
39
41
43
46
50
54
1280
1450
1730
2050
2400
2820
3250
3850
4650
5600
6830
150
160
180
180
180
200
200
220
220
240
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.73
0.70
0.66
0.64
0.63
0.61
0.58
0.57
0.55
0.53
0.44
0.42
0.40
0.37
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.19
0.21
0.23
0.26
0.28
0.30
0.33
0.37
0.40
0.44
0.49
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
12/20 (24) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
32
34
36
38
40
41
43
46
49
52
56
1400
1600
1950
2300
2600
3020
3400
4050
4850
5850
7050
160
180
180
200
200
200
220
220
240
260
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.78
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.54
0.54
0.44
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
39
40
42
43
46
48
49
52
55
59
63
1850
2050
2350
2700
3160
3600
4020
4700
5500
6570
7850
200
200
200
220
220
240
240
260
260
260
280
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.58
0.56
0.43
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.31
0.30
0.30
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
0.28
0.30
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
18/30 (36) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16rm
1x150/25rm
1x185/25rm
1x240/25rm
1x300/25rm
1x400/35rm
1x500/35rm
73
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC8V
YAPISI
Bakır iletken (sınıf 2)
‹ç yarı iletken tabaka
XLPE izole
Dıfl yarı iletken tabaka
Yarı iletken krep ka¤ıdı
Bakır flerit ekran
PP dolgu
PVC dıfl kılıf
1
2
3
4
5
6
7
8
8
7
6
5 4 3 2
1
ÖZELL‹KLER
Tip
Standartlar
Anma Gerilimi
: YXC8V (N2XSEY)
: TS IEC 60502-2 - TSEK
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Kullan›ld›¤› Yerler
:
Mekanik zorlanmalara karflı yapısındaki zırh sayesinde
mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür.
Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi
ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde,
hariçte, toprak altında veya kablo kanallarında kullanılır.
C
90
r
250
-20 / +60 C
r=15 x D
o
Kullanım Sıcaklı¤ı
Maks. ‹flletme Sıcaklı¤ı
Kısa Devre Sıcaklı¤ı
Aleve Dayanıklılık
IEC 60332 -1-2
Min. Bükülme Yarıçapı
RoHS
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Net a¤›rl›k Standart sevk
Sevk
yaklafl›k
uzunlu¤u
makara tipi
20°C’de
iletken
DC direnci
Çal›flma
indüktans›
yaklafl›k
Çal›flma Ak›m tafl›ma kapasitesi (30°C)
kapasitesi
Toprakta
Havada
yaklafl›k
Nominal
kesit
D›fl çap
yaklafl›k
mm2
mm
kg/km
m
cm
Ω / km (max.)
mH/km
MF/km
A
A
43
46
49
53
57
61
64
69
74
2700
2950
3900
4950
5850
6900
7950
9400
10650
500
500
500
500
500
500
500
250
250
180
180
180
200
220
220
240
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.22
0.24
0.28
0.31
0.34
0.36
0.40
0.45
0.51
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
6/10 kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
74
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC8V
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
D›fl çap
yaklafl›k
mm2
mm
Net a¤›rl›k Standart sevk
Sevk
yaklafl›k
uzunlu¤u
makara tipi
kg/km
m
cm
20°C’de
iletken
DC direnci
Ω / km (max.)
Çal›flma
indüktans›
yaklafl›k
Çal›flma Ak›m tafl›ma kapasitesi (30°C)
kapasitesi
Toprakta
Havada
yaklafl›k
mH/km
MF/km
A
A
8.7/15 (17.5) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16rm
3x150/25rm
3x185/25rm
3x240/25rm
3x300/25rm
49
51
55
59
63
66
69
74
79
3200
3600
4500
5450
6350
7250
8950
9500
1060
500
500
500
500
500
500
250
250
250
180
200
200
220
220
220
200
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.40
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
12/20 (24) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
52
54
58
62
65
69
72
78
83
3700
4300
5200
6250
7300
8450
9500
11900
13900
500
500
500
500
500
250
250
250
250
200
200
220
220
220
200
200
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.33
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
4900
5400
6500
7500
8650
9250
10100
12100
15150
500
500
250
250
250
250
250
250
250
200
220
220
220
220
240
240
240
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
18/30 (36) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
63
66
70
74
77
80
84
88
93
20.3/35 (42) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
68
71
75
78
82
85
88
94
98
5200
6250
7150
8300
9250
10050
11200
12500
15600
250
250
250
250
250
250
250
250
250
220
220
220
240
240
240
240
240
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
75
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC8VZ3V
YAPISI
Bakır iletken (sınıf 2)
‹ç yarı iletken tabaka
XLPE izole
Dıfl yarı iletken tabaka
Yarı iletken krep ka¤ıdı
Bakır flerit ekran
PP dolgu
PVC ayırıcı kılıf
Galvanizli yassı çelik tel
Galvanizli çelik bant
PVC dıfl kılıf
1
2
3
4
5
6
7
8
9
10
11
11
10 9
8 7 6 5 4 3
2 1
ÖZELL‹KLER
Tip
Standartlar
Anma Gerilimi
: YXC8VZ3V (N2XSEYFGY)
: TS IEC 60502-2 - TSEK
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Kullan›ld›¤› Yerler
:
Mekanik zorlanmalara karflı yapısındaki zırh sayesinde
mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür.
Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi
ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde,
hariçte, toprak altında veya kablo kanallarında kullanılır.
C
90
r
250
-20 / +60 C
r=15 x D
o
Kullanım Sıcaklı¤ı
Maks. ‹flletme Sıcaklı¤ı
Kısa Devre Sıcaklı¤ı
Aleve Dayanıklılık
IEC 60332 -1-2
Darbe Dayanıklılı¤ı
Min. Bükülme Yarıçapı
RoHS
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Net a¤›rl›k Standart sevk
Sevk
yaklafl›k
uzunlu¤u
makara tipi
20°C’de
iletken
DC direnci
Çal›flma
indüktans›
yaklafl›k
Çal›flma Ak›m tafl›ma kapasitesi (30°C)
kapasitesi
Toprakta
Havada
yaklafl›k
Nominal
kesit
D›fl çap
yaklafl›k
mm2
mm
kg/km
m
cm
Ω / km (max.)
mH/km
MF/km
A
A
49
52
57
60
64
67
71
77
83
3640
4200
5150
6200
7150
8250
9600
10650
14050
500
500
500
500
500
500
500
250
250
200
210
220
220
240
240
260
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.22
0.24
0.28
0.31
0.34
0.36
0.40
0.45
0.51
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
6/10 kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
76
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC8VZ3V
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
D›fl çap
yaklafl›k
Net a¤›rl›k Standart sevk
Sevk
yaklafl›k
uzunlu¤u
makara tipi
mm2
mm
kg/km
m
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16rm
3x150/25rm
3x185/25rm
3x240/25rm
3x300/25rm
55
58
62
66
69
73
77
83
89
4200
4800
5750
6850
7850
8950
10300
12450
14900
500
500
500
500
250
250
250
250
250
210
220
220
240
200
210
220
240
260
12/20 (24) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
60
63
67
71
74
78
87
88
93
4750
5350
6350
7450
8450
9600
11000
13200
15700
500
500
500
500
250
250
250
250
250
72
75
79
83
86
90
94
100
106
6250
6900
7950
9100
10200
11400
12900
15200
17800
250
250
250
250
250
250
250
250
250
20°C’de
iletken
DC direnci
Çal›flma Ak›m tafl›ma kapasitesi (30°C)
kapasitesi
Toprakta
Havada
yaklafl›k
mH/km
MF/km
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
220
220
240
260
210
220
240
240
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
210
220
220
240
240
260
260
280
300
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
cm
Ω / km (max.)
Çal›flma
indüktans›
yaklafl›k
A
A
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.40
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.33
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
8.7/15 (17.5) kV
18/30 (36) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
20.3/35 (42) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
77
80
84
88
91
95
99
105
110
6900
7600
8650
9850
10950
12150
13700
16000
18550
250
250
250
250
250
250
250
250
250
220
220
240
240
260
260
280
300
300
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
77
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC8VZ4V
YAPISI
1
2
3
4
5
6
7
8
9
10
Bakır iletken (sınıf 2)
‹ç yarı iletken tabaka
XLPE izole
Dıfl yarı iletken tabaka
Yarı iletken krep ka¤ıdı
Bakır flerit ekran
PP dolgu
PVC ayırıcı kılıf
Galvanizli çift çelik bant
PVC dıfl kılıf
10
9
8 7 6 5 4
3 2 1
ÖZELL‹KLER
Tip
Standartlar
Anma Gerilimi
: YXC8VZ4V (N2XSEYBY)
: TS IEC 60502-2 - TSEK
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Kullan›ld›¤› Yerler
:
Mekanik zorlanmalara karflı yapısındaki zırh sayesinde
mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür.
Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi
ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde,
hariçte, toprak altında veya kablo kanallarında kullanılır.
C
90
r
250
-20 / +60 C
r=15 x D
o
Kullanım Sıcaklı¤ı
Maks. ‹flletme Sıcaklı¤ı
Kısa Devre Sıcaklı¤ı
Aleve Dayanıklılık
IEC 60332 -1-2
Darbe Dayanıklılı¤ı
Min. Bükülme Yarıçapı
RoHS
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Çal›flma
indüktans›
yaklafl›k
D›fl çap
yaklafl›k
mm2
mm
kg/km
m
cm
Ω / km (max.)
mH/km
49
52
57
60
64
67
71
77
84
3400
4000
4900
5900
6850
7900
9250
11300
14450
500
500
500
500
500
500
500
250
250
200
210
220
220
240
240
260
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
6/10 kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
78
Net a¤›rl›k Standart sevk
Sevk
yaklafl›k
uzunlu¤u
makara tipi
20°C’de
iletken
DC direnci
Nominal
kesit
Çal›flma Ak›m tafl›ma kapasitesi (30°C)
kapasitesi
Toprakta
Havada
yaklafl›k
MF/km
0.22
0.24
0.28
0.31
0.34
0.36
0.40
0.45
0.51
A
154
181
220
263
298
332
374
431
492
A
172
205
253
307
352
397
453
529
608
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC8VZ4V
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Net a¤›rl›k Standart sevk
Sevk
yaklafl›k
uzunlu¤u
makara tipi
20°C’de
iletken
DC direnci
Çal›flma
indüktans›
yaklafl›k
Nominal
kesit
D›fl çap
yaklafl›k
mm2
mm
kg/km
m
55
58
62
66
69
73
77
84
90
3950
4550
5450
6500
7500
8600
9900
12800
15300
500
500
500
500
250
250
250
250
250
210
220
220
240
200
210
220
240
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.29
cm
Ω / km (max.)
mH/km
Çal›flma Ak›m tafl›ma kapasitesi (30°C)
kapasitesi
Toprakta
Havada
yaklafl›k
MF/km
A
A
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.40
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
8.7/15 (17.5) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
12/20 (24) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
60
62
67
70
74
77
83
89
95
4450
5050
6000
7100
8100
9200
11350
13600
16100
500
500
500
500
250
250
250
250
200
220
220
240
240
210
220
240
260
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
18/30 (36) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
72
75
79
84
88
91
95
101
107
5900
6500
7550
9500
10600
11800
13300
15600
18250
250
250
250
250
250
250
250
250
250
210
220
220
240
240
260
260
280
300
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
20.3/35 (42) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
77
80
85
89
93
96
100
106
112
6500
7200
9050
10250
11400
12600
14200
16500
19200
250
250
250
250
250
250
250
250
250
220
220
240
260
260
260
280
300
320
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
79
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC8VZ2V
YAPISI
1
2
3
4
5
6
7
8
9
10
Bakır iletken (sınıf 2)
‹ç yarı iletken tabaka
XLPE izole
Dıfl yarı iletken tabaka
Yarı iletken krep ka¤ıdı
Bakır flerit ekran
PP dolgu
PVC ayırıcı kılıf
Galvanizli yuvarlak çelik tel
PVC dıfl kılıf
10
9
8
7 6 5 4
3 2 1
ÖZELL‹KLER
Tip
Standartlar
Anma Gerilimi
: YXC8VZ2V (N2XSEYRY)
: TS IEC 60502-2 - TSEK
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
C
90
Kullan›ld›¤› Yerler :
Mekanik zorlanmalara karflı yapısındaki zırh sayesinde
mukavemetlidir. Bu kabloların elektriksel kayıpları küçüktür.
Endüstri bölgelerinin ve yerleflim merkezlerinin elektrik enerjisi
ile beslenmesinde, yük artıflı beklenen flebekelerde, dahilde,
hariçte, toprak altında veya kablo kanallarında kullanılır.
r
250
-20 / +60 C
r=15 x D
o
Kullanım Sıcaklı¤ı
Maks. ‹flletme Sıcaklı¤ı
Kısa Devre Sıcaklı¤ı
Aleve Dayanıklılık
IEC 60332 -1-2
Darbe Dayanıklılı¤ı
Min. Bükülme Yarıçapı
RoHS
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
D›fl çap
yaklafl›k
Net a¤›rl›k Standart sevk
Sevk
yaklafl›k
uzunlu¤u
makara tipi
mm2
mm
kg/km
m
53
56
60
64
68
71
76
83
88
5000
5650
6750
7850
9000
10100
12450
14800
17450
500
500
500
500
500
500
250
250
250
cm
20°C’de
iletken
DC direnci
Ω / km (max.)
Çal›flma
indüktans›
yaklafl›k
mH/km
Çal›flma Ak›m tafl›ma kapasitesi (30°C)
kapasitesi
Toprakta
Havada
yaklafl›k
MF/km
A
A
6/10 kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
80
210
220
220
240
240
260
220
240
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.22
0.24
0.28
0.31
0.34
0.36
0.40
0.45
0.51
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC8VZ2V
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
Nominal
kesit
D›fl çap
yaklafl›k
Net a¤›rl›k Standart sevk
Sevk
yaklafl›k
uzunlu¤u
makara tipi
mm2
mm
kg/km
8.7/15 (17.5) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
m
58
61
66
69
74
78
82
88
94
5750
6400
7500
8700
9800
11800
13400
15800
18500
500
500
500
500
500
250
250
250
250
220
220
240
240
260
220
240
240
260
12/20 (24) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
63
66
71
76
80
83
86
93
99
6450
7150
8200
10300
11450
12700
14200
16700
19500
500
500
500
250
250
250
250
250
250
18/30 (36) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16rm
3x150/25rm
3x185/25rm
3x240/25rm
3x300/25 rm
77
80
84
88
92
95
99
105
111
9100
9900
11100
12500
13700
15050
16700
19250
22100
20.3/35 (42) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
82
84
89
93
96
99
104
109
115
9900
10700
11950
13300
14600
15900
17700
20150
23000
20°C’de
iletken
DC direnci
Çal›flma Ak›m tafl›ma kapasitesi (30°C)
kapasitesi
Toprakta
Havada
yaklafl›k
mH/km
MF/km
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.29
220
240
260
220
220
240
240
260
280
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
250
250
250
250
250
250
250
250
250
220
220
240
240
260
260
280
300
320
250
250
250
250
250
250
250
250
250
240
240
260
260
260
280
300
300
320
cm
Ω / km (max.)
Çal›flma
indüktans›
yaklafl›k
A
A
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.40
154
181
220
263
298
332
374
431
608
172
205
253
307
352
397
453
529
608
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
154
181
220
263
298
332
374
431
608
172
205
253
307
352
397
453
529
608
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
154
181
220
263
298
332
374
431
608
172
205
253
307
352
397
453
529
608
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
608
172
205
253
307
352
397
453
529
608
81
ORTA VE YÜKSEK GER‹L‹M ENERJ‹ KABLOLARI
YXC7(Q)A2E
YAPISI
Bakır iletken (sınıf 2)
‹ç yarı iletken tabaka
XLPE izole
Dıfl yarı iletken tabaka
Yarı iletken suda fliflen bant
Konsantrik iletken
Bakır bant
Su tutucu bant
Kopolimerli alüminyum bant
Polietilen dıfl kılıf
1
2
3
4
5
6
7
8
9
10
10
9 8 7 6 5
4
3
2
1
ÖZELL‹KLER
Tip
Standartlar
Anma Gerilimi
: YXC7(Q)A2E (2XS(FL)2Y)
: IEC 60840 Test Standardı
: Uo/U=26/45 kV
Uo/U=38/66 kV
Uo/U=64/100 kV
Uo/U=89/154 kV
C
Kullan›ld›¤› Yerler :
Enerji üretim merkezlerinden, ulusal ve uluslararası
enterkonnekte flebekelerin beslenmelerinde, kentlerin ana
da¤ıtım sistemlerine ba¤lanmasında, güvenlik ve çevre koruması
nedeni ile yüksek gerilim havai hatlarla flehir merkezlerine
girilemeyen yerlerde, hariçte, kablo kanallarında ve toprak
altında kullanılır. Ayrıca bu kablolar su geçirmez özelliktedir.
C
90
r
250
-20 / +60 C
r=15 x D
o
Kullanım Sıcaklı¤ı
Maks. ‹flletme Sıcaklı¤ı
Kısa Devre Sıcaklı¤ı
Aleve Dayanıklılık
IEC 60332 -1-2
Min. Bükülme Yarıçapı
RoHS
F‹Z‹KSEL VE ELEKTR‹KSEL ÖZELL‹KLER
20°C’de
iletken
DC direnci
Çal›flma
indüktans›
yaklafl›k
Ω / km (max.)
mH/km
MF/km
A
210
220
240
0.0601
0.0470
0.0366
0.37
0.35
0.33
0.20
0.22
0.24
598
673
759
250
250
250
240
240
240
0.0283
0.0221
0.0176
0.48
0.46
0.43
0.19
0.21
0.24
764
896
931
13300
15100
17200
250
250
250
260
260
280
0.0283
0.0221
0.0176
0.59
0.57
0.55
0.18
0.19
0.21
821
902
968
14200
15900
18100
250
250
250
260
280
280
0.0283
0.0221
0.0176
0.69
0.68
0.66
0.16
0.18
0.19
1080
1220
1355
Nominal
kesit
D›fl çap
yaklafl›k
Net a¤›rl›k Standart sevk
Sevk
yaklafl›k
uzunlu¤u
makara tipi
mm2
mm
kg/km
m
cm
53
62
67
5300
6100
7200
500
500
500
80
83
88
12200
14000
16000
89
93
97
95
99
103
Çal›flma Ak›m tafl›ma kapasitesi (30°C)
kapasitesi
Toprakta
yaklafl›k
26/45 (52) kV
1x300/35 rm
1x400/35 rm
1x500/50 rm
38/66 (76) kV
1x630/135 rm
1x800/135 rm
1x1000/135 rm
64/110 (123) kV
1x630/135 rm
1x800/135 rm
1x1000/135 rm
89/154 (175) kV
1x630/135 rm
1x800/135 rm
1x1000/135 rm
• Bu tür kabloların konstrüksiyonları proje bazında hazırlanmaktadır. Detaylı bilgi için firmamızla temas kurunuz.
82
MEDIUM AND HIGH
VOLTAGE POWER CABLES
N2XSY
N2XS(F)2Y
NA2XS(F)2Y
CU/XLPE/SC/AWA/PVC
N2XSEY
N2XSEYFGY
N2XSEYBY
N2XSEYRY
2XS(FL)2Y
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSY
CONSTRUCTION
1
2
3
4
5
6
7
8
Copper conductor (class 2)
Inner semi conductive layer
XLPE insulation
Outer semi conductive layer
Semi conductive crepe paper
Concentric conductor
Copper tape
PVC outer sheath
8
7
6
5
4
3
2
1
SPECIFICATIONS
Code
Standards
Rated voltage
: N2XSY
: VDE 0273 IEC 60502-2
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Application
:
On this cable, electrical losses are minimized. Used for supplying
power for populated and industrial regions, networks having
voltage increase risk; can be installed in underground, indoor,
outdoor and also in cable channel applications.
C
90
r
250
-20 / +60 C
r=15 x D
o
Temperature Range
Max. Operation Temperature
Short Circuit Temperature
Flame Retardant
IEC 60332 -1-2
Min. Bending Radius
RoHS
PHYSICAL AND ELECTRICAL PROPERTIES
Overall Net weight Delivery drum Conductor DC Operating
Nominal
resistance
type for
inductance
cross-section diameter
approx.
at 20°C
approx.
1000 m. cable
approx
mm2
mm
kg/km
m
Ω / km (max.)
6/10 (12) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
22
23
25
27
28
30
31
34
37
40
44
800
940
1160
1420
1670
2060
2400
2970
3650
4550
5650
120
130
140
140
150
150
160
180
180
200
220
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
66
mH/km mH/km
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.53
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.28
Operating
capacity
approx
MF/km
0.22
0.24
0.28
0.31
0.33
0.36
0.40
0.45
0.51
0.57
0.63
Current carrying capacity in (30°C)
Earth
Air
A
A
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSY
PHYSICAL AND ELECTRICAL PROPERTIES
Overall Net weight Delivery drum Conductor DC Operating
Nominal
resistance
type for
inductance
cross-section diameter
approx.
at 20°C
approx.
1000 m. cable
approx
mm2
mm
8.7/15 (17.5) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
24
26
27
29
31
32
34
36
39
43
46
12/20 (24) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
26
28
30
31
33
35
36
39
42
45
49
kg/km
875
1020
1240
1520
1770
2160
2520
3090
3780
4690
5780
960
1100
1350
1620
1900
2275
2650
3250
3960
4870
5950
m
Ω / km (max.)
130
140
140
150
160
160
180
180
200
220
220
140
150
150
160
160
180
180
200
200
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
mH/km mH/km
0.75
0.73
0.70
0.66
0.64
0.63
0.61
0.58
0.57
0.55
0.53
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.54
0.44
0.42
0.40
0.37
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.29
Operating
capacity
approx
MF/km
0.18
0.19
0.22
0.25
0.27
0.29
0.31
0.35
0.40
0.44
0.49
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
Current carrying capacity in (30°C)
Earth
Air
A
A
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
18/30 (36 )kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
32
33
35
37
39
40
42
44
47
50
54
1200
1350
1620
1900
2200
2600
3000
3600
4300
5270
6400
160
160
180
180
200
200
200
220
220
240
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.43
0.42
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.30
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
0.28
0.36
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
20.3/35 (42)kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
34
35
37
39
41
42
44
46
49
53
56
1300
1500
1750
2050
2350
2750
3100
3700
4480
5420
6550
180
180
180
200
200
200
220
220
240
260
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.77
0.75
0.71
0.68
0.66
0.64
0.62
0.60
0.59
0.57
0.55
0.51
0.42
0.40
0.38
0.36
0.35
0.39
0.37
0.36
0.35
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.18
0.20
0.23
0.25
0.28
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1020
198
238
296
361
417
473
543
641
735
845
942
67
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XS(F)2Y
CONSTRUCTION
Copper conductor (class 2)
Inner semi conductive layer
XLPE insulation
Outer semi conductive layer
Semi conductive water blocking tape
Concentric conductor
Copper tape
Water Swelling tape
PE outer sheath
1
2
3
4
5
6
7
8
9
9
8 7
6 5
4
3
2
1
SPECIFICATIONS
Code
Standards
Rated voltage
: N2XS(F)2Y
: VDE 0273 IEC 60502-2
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Application
:
On this cable, electrical losses are minimized. Used for supplying
power for populated and industrial regions, networks having
voltage increase risk; can be installed in underground, indoor,
outdoor and also in cable channel applications.These cables
can also be used in humid and wet applications.
C
90
r
250
-20 / +60 C
r=15 x D
o
Temperature Range
Max. Operation Temperature
Short Circuit Temperature
Flame Retardant
IEC 60332 -1-2
Min. Bending Radius
RoHS
PHYSICAL AND ELECTRICAL PROPERTIES
Overall Net weight Delivery drum Conductor DC Operating
Nominal
resistance
type for
inductance
cross-section diameter
approx.
at 20°C
approx.
1000 m. cable
approx
mm2
mm
kg/km
m
Ω / km (max.)
mH/km mH/km
Operating
capacity
approx
MF/km
Current carrying capacity in (30°C)
Earth
Air
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
A
A
6/10 (12) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
68
23
24
26
28
30
31
32
35
38
41
45
800
940
1160
1420
1670
2060
2400
2970
3650
4550
5650
130
130
140
150
150
160
160
180
200
200
220
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.53
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.28
0.22
0.24
0.28
0.31
0.33
0.36
0.40
0.45
0.51
0.57
0.63
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XS(F)2Y
PHYSICAL AND ELECTRICAL PROPERTIES
Overall Net weight Delivery drum Conductor DC Operating
Nominal
resistance
type for
inductance
cross-section diameter
approx.
at 20°C
approx.
1000 m. cable
approx
mm2
mm
kg/km
m
Ω / km (max.)
mH/km mH/km
Operating
capacity
approx
MF/km
Current carrying capacity in (30°C)
Earth
Air
A
A
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
8.7/15 (17.5) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
25
27
28
30
31
33
34
37
40
43
47
875
1020
1240
1520
1770
2160
2520
3090
3780
4690
5780
140
140
150
150
160
160
180
180
200
220
220
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
12/20 (24) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
27
28
30
32
34
35
37
39
42
45
49
960
1100
1350
1620
1900
2275
2650
3250
3960
4870
5950
140
150
150
160
180
180
180
200
200
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.54
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.29
18/30 (36) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
33
34
36
37
39
40
42
45
48
51
55
160
180
180
180
200
200
200
220
240
260
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.75
0.72
0.69
0.69
0.64
0.62
0.60
0.58
0.56
0.53
0.42
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.30
20.3/35 (42) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16rm
1x150/25rm
1x185/25rm
1x240/25rm
1x300/25rm
1x400/35rm
1x500/35rm
35
36
38
39
41
43
44
47
50
53
57
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.77
0.75
0.71
0.68
0.66
0.64
0.62
0.60
0.59
0.57
0.55
0.51
0.42
0.40
0.38
0.36
0.35
0.39
0.37
0.36
0.35
0.33
1200
1350
1620
1900
2200
2600
3000
3600
4300
5270
6400
1300
1500
1750
2050
2350
2750
3100
3700
4480
5420
6550
180
180
200
200
200
220
220
220
240
260
260
0.75
0.73
0.70
0.66
0.64
0.63
0.61
0.58
0.57
0.55
0.53
0.44
0.42
0.40
0.37
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.19
0.21
0.23
0.26
0.28
0.30
0.33
0.37
0.40
0.44
0.49
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
0.28
0.30
0.11
0.12
0.14
0.15
0.16
0.17
0.18
0.20
0.23
0.25
0.28
69
MEDIUM AND HIGH VOLTAGE POWER CABLES
NA2XS(F)2Y
CONSTRUCTION
Aluminium conductor (class 2)
Inner semi conductive layer
XLPE insulation
Outer semi conductive layer
Semi conductive water blocking tape
Concentric conductor
Copper tape
Water Swelling tape
PE outer sheath
1
2
3
4
5
6
7
8
9
9
8 7
6 5
4
3
2
1
SPECIFICATIONS
Code
Standards
Rated voltage
: NA2XS(F)2Y
: VDE 0273 IEC 60502-2
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Application
:
On this cable, electrical losses are minimized. Used for supplying
power for populated and industrial regions, networks having
voltage increase risk; can be installed in underground, indoor,
outdoor and also in cable channel applications.These cables
can also be used in humid and wet applications.
C
90
r
250
-20 / +60 C
r=15 x D
o
Temperature Range
Max. Operation Temperature
Short Circuit Temperature
Flame Retardant
IEC 60332 -1-2
Min. Bending Radius
RoHS
PHYSICAL AND ELECTRICAL PROPERTIES
Overall Net weight Delivery drum Conductor DC Operating
Nominal
resistance
type for
inductance
cross-section diameter
approx.
at 20°C
approx.
1000 m. cable
approx
mm2
mm
kg/km
m
Ω / km (max.)
mH/km mH/km
Operating
capacity
approx
MF/km
Current carrying capacity in (30°C)
Earth
Air
A
A
A
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
A
6/10 (12) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
70
23
24
26
28
29
31
33
35
37
41
44
600
670
765
870
995
1200
1350
1580
1800
2200
2650
130
130
140
150
150
160
160
180
200
200
220
0.641
0.443
0.320
0.253
0.206
0.206
0.164
0.125
0.100
0.0778
0.0605
0.78
0.73
0.69
0.66
0.64
0.62
0.61
0.58
0.56
0.55
0.53
0.43
0.41
0.38
0.36
0.35
0.34
0.33
0.32
0.31
0.30
0.29
0.23
0.24
0.27
0.30
0.33
0.36
0.39
0.44
0.48
0.53
0.59
122
144
176
210
240
267
303
351
397
451
502
MEDIUM AND HIGH VOLTAGE POWER CABLES
NA2XS(F)2Y
PHYSICAL AND ELECTRICAL PROPERTIES
Overall Net weight Delivery drum Conductor DC Operating
Nominal
resistance
type for
inductance
cross-section diameter
approx.
at 20°C
approx.
1000 m. cable
approx
mm2
8.7/15 (17.5) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
12/20 (24) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
18/30 (36) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
20.3/35 (42) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16rm
1x150/25rm
1x185/25rm
1x240/25rm
1x300/25rm
1x400/35rm
1x500/35rm
mm
kg/km
m
Ω / km (max.)
mH/km mH/km
0.45
0.43
0.40
0.38
0.37
0.35
0.34
0.33
0.32
0.31
0.30
Current carrying capacity in (30°C)
Earth
Air
A
A
A
A
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
122
144
176
210
240
267
303
351
397
451
502
0.14
0.17
0.19
0.21
0.23
0.25
0.27
0.30
0.32
0.35
0.37
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
122
144
176
210
240
267
303
351
397
451
502
MF/km
25
26
28
30
31
33
35
37
40
43
46
700
770
850
1000
1100
1300
1500
1700
1950
2400
2800
140
140
150
150
160
160
180
180
200
220
220
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
27
29
30
32
34
35
37
40
42
45
48
800
850
950
1100
1200
1500
1600
1850
2100
2550
2950
140
150
150
160
180
180
180
200
200
220
240
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.75
0.72
0.69
0.66
0.64
0.62
0.59
0.57
0.55
0.53
0.51
33
34
36
37
39
41
42
45
47
50
54
1050
1100
1250
1360
1550
1750
1950
2200
2450
2950
3450
160
180
180
180
200
200
200
220
240
260
260
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.74
0.71
0.68
0.64
0.62
0.59
0.57
0.55
0.53
0.51
0.49
0.49
0.47
0.45
0.42
0.41
0.40
0.38
0.37
0.35
0.34
0.33
0.11
0.13
0.15
0.16
0.17
0.19
0.20
0.22
0.24
0.26
0.28
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
122
144
176
210
240
267
303
351
397
451
502
35
36
38
40
41
43
45
47
49
53
56
1150
1250
1400
1500
1650
1900
2100
2350
2650
3100
3600
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.74
0.71
0.68
0.64
0.62
0.59
0.57
0.55
0.53
0.51
0.49
0.49
0.47
0.45
0.42
0.41
0.40
0.38
0.37
0.35
0.34
0.33
0.11
0.13
0.15
0.16
0.17
0.19
0.20
0.22
0.24
0.26
0.28
134
157
192
229
260
288
324
373
419
466
526
129
152
186
221
252
281
317
367
414
470
542
123
146
178
213
242
271
307
356
402
457
508
122
144
176
210
240
267
303
351
397
451
502
180
180
200
200
200
220
220
220
240
260
260
0.76
0.73
0.70
0.67
0.65
0.63
0.61
0.59
0.57
0.55
0.53
Operating
capacity
approx
0.43
0.41
0.39
0.36
0.35
0.33
0.32
0.31
0.30
0.29
0.27
0.16
0.19
0.22
0.24
0.27
0.29
0.31
0.34
0.38
0.41
0.46
71
MEDIUM AND HIGH VOLTAGE POWER CABLES
CU/XLPE/SC/AWA/PVC
CONSTRUCTION
1
2
3
4
5
6
7
8
9
10
Copper conductor (class 2)
Inner semi conductive layer
XLPE insulation
Outer semi conductive layer
Semi conductive crepe paper
Concentric conductor
Copper tape
PVC separation sheath
Aluminium round wire
PVC outer sheath
10
9 8 7 6
5
4
3
2
1
SPECIFICATIONS
Code
Standards
Rated voltage
: CU/XLPE / SC / AWA / PVC
: BS 6622 IEC 60502-2
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Application
:
On this cable, electrical losses are minimized. Used for supplying
power for populated and industrial regions, networks having
voltage increase risk; can be installed in underground, indoor,
outdoor and also in cable channel applications. The armour in
the structure makes the cable necessary where there is
mechanical stress risk.
C
90
r
250
-20 / +60 C
r=15 x D
o
Temperature Range
Max. Operation Temperature
Short Circuit Temperature
Flame Retardant
IEC 60332 -1-2
Min. Bending Radius
RoHS
PHYSICAL AND ELECTRICAL PROPERTIES
Overall Net weight Delivery drum Conductor DC Operating
Nominal
resistance
type for
inductance
cross-section diameter
approx.
at 20°C
approx.
1000 m. cable
approx
mm2
mm
6/10 (12)kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
28
29
31
32
35
36
38
41
44
48
51
72
kg/km
1150
1330
1600
1900
2300
2700
3050
3700
4450
5450
6600
m
150
150
160
160
180
180
200
200
220
240
260
Ω / km (max.)
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
mH/km mH/km
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.56
0.54
0.53
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.28
Operating
capacity
approx
MF/km
0.22
0.24
0.28
0.31
0.33
0.36
0.40
0.45
0.51
0.57
0.63
Current carrying capacity in (30°C)
Earth
Air
A
A
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
A
A
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
MEDIUM AND HIGH VOLTAGE POWER CABLES
CU/XLPE/SC/AWA/PVC
PHYSICAL AND ELECTRICAL PROPERTIES
Overall Net weight Delivery drum Conductor DC Operating
Nominal
resistance
type for
inductance
cross-section diameter
approx.
at 20°C
approx.
1000 m. cable
approx
mm2
mm
kg/km
m
Ω / km (max.)
mH/km mH/km
Operating
capacity
approx
MF/km
Current carrying capacity in (30°C)
Earth
Air
A
A
A
A
8.7/15 (17.5) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
30
31
34
36
37
39
41
43
46
50
54
1280
1450
1730
2050
2400
2820
3250
3850
4650
5600
6830
150
160
180
180
180
200
200
220
220
240
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.73
0.70
0.66
0.64
0.63
0.61
0.58
0.57
0.55
0.53
0.44
0.42
0.40
0.37
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.19
0.21
0.23
0.26
0.28
0.30
0.33
0.37
0.40
0.44
0.49
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
12/20 (24) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16 rm
1x150/25 rm
1x185/25 rm
1x240/25 rm
1x300/25 rm
1x400/35 rm
1x500/35 rm
32
34
36
38
40
41
43
46
49
52
56
1400
1600
1950
2300
2600
3020
3400
4050
4850
5850
7050
160
180
180
200
200
200
220
220
240
260
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.78
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.54
0.54
0.44
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.30
0.29
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
0.37
0.41
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
39
40
42
43
46
48
49
52
55
59
63
1850
2050
2350
2700
3160
3600
4020
4700
5500
6570
7850
200
200
200
220
220
240
240
260
260
260
280
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.75
0.72
0.69
0.66
0.64
0.62
0.60
0.58
0.58
0.56
0.43
0.42
0.40
0.38
0.36
0.35
0.34
0.33
0.31
0.31
0.30
0.30
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
0.28
0.30
172
203
246
293
332
366
410
470
524
572
632
166
196
239
285
323
361
406
469
526
590
658
238
286
356
434
500
559
637
745
846
938
1026
198
238
296
361
417
473
543
641
735
845
942
18/30 (36) kV
1x35/16 rm
1x50/16 rm
1x70/16 rm
1x95/16 rm
1x120/16rm
1x150/25rm
1x185/25rm
1x240/25rm
1x300/25rm
1x400/35rm
1x500/35rm
73
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSEY
CONSTRUCTION
1
2
3
4
5
6
7
8
Copper conductor (class 2)
Inner semi conductive layer
XLPE insulation
Outer semi conductive layer
Semi conductive crepe paper
Copper tape screen
PP filler
PVC outer sheath
8
7
6
5 4 3 2
1
SPECIFICATIONS
Code
Standards
Rated voltage
: N2XSEY
: VDE 0273
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Application
:
On this cable, electrical losses are minimized. Used for supplying
power for populated and industrial regions, networks having
voltage increase risk; can be installed in underground, indoor,
outdoor and also in cable channel applications. The armour in
the structure makes the cable necessary where there is
mechanical stress risk.
C
90
r
250
-20 / +60 C
r=15 x D
o
Temperature Range
Max. Operation
Temperature
Short Circuit
Temperature
Flame Retardant
IEC 60332 -1-2
Min. Bending Radius
RoHS
PHYSICAL AND ELECTRICAL PROPERTIES
Overall
Nominal
cross-section diameter
approx.
mm2
Net weight
approx.
Delivery Delivery drum Conductor DC Operating
length
resistance inductance
type
at 20°C
approx
Operating
capacity
approx
Current carrying capacity in (30°C)
Earth
Air
mm
kg/km
m
cm
Ω / km (max.)
mH/km
MF/km
A
A
43
46
49
53
57
61
64
69
74
2700
2950
3900
4950
5850
6900
7950
9400
10650
500
500
500
500
500
500
500
250
250
180
180
180
200
220
220
240
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.22
0.24
0.28
0.31
0.34
0.36
0.40
0.45
0.51
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
6/10 kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
74
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSEY
PHYSICAL AND ELECTRICAL PROPERTIES
Overall
Nominal
cross-section diameter
approx.
mm2
mm
Net weight
approx.
kg/km
Delivery Delivery drum Conductor DC Operating
length
resistance inductance
type
at 20°C
approx
m
cm
Ω / km (max.)
Operating Current carrying capacity in (30°C)
capacity
Earth
Air
approx
mH/km
MF/km
A
A
8.7/15 (17.5) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16rm
3x150/25rm
3x185/25rm
3x240/25rm
3x300/25rm
49
51
55
59
63
66
69
74
79
3200
3600
4500
5450
6350
7250
8950
9500
1060
500
500
500
500
500
500
250
250
250
180
200
200
220
220
220
200
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.40
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
12/20 (24) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
52
54
58
62
65
69
72
78
83
3700
4300
5200
6250
7300
8450
9500
11900
13900
500
500
500
500
500
250
250
250
250
200
200
220
220
220
200
200
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.33
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
4900
5400
6500
7500
8650
9250
10100
12100
15150
500
500
250
250
250
250
250
250
250
200
220
220
220
220
240
240
240
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
18/30 (36) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
63
66
70
74
77
80
84
88
93
20.3/35 (42) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
68
71
75
78
82
85
88
94
98
5200
6250
7150
8300
9250
10050
11200
12500
15600
250
250
250
250
250
250
250
250
250
220
220
220
240
240
240
240
240
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
75
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSEYFGY
CONSTRUCTION
1
2
3
4
5
6
7
8
9
10
11
Copper conductor (class 2)
Inner semi conductive layer
XLPE insulation
Outer semi conductive layer
Semi conductive crepe paper
Copper tape screen
PP filler
PVC separation sheath
Galvanized flat steel wire
Galvanized steel tape
PVC outer sheath
11
10 9
8 7 6 5 4 3
2 1
SPECIFICATIONS
Code
Standards
Rated voltage
: N2XSEYFGY
: VDE 0273
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Application
:
On this cable, electrical losses are minimized. Used for supplying
power for populated and industrial regions, networks having
voltage increase risk; can be installed in underground, indoor,
outdoor and also in cable channel applications. The armour in
the structure makes the cable necessary where there is
mechanical stress risk.
C
90
r
250
-20 / +60 C
r=15 x D
o
Temperature Range
Max. Operation
Temperature
Short Circuit
Temperature
Flame Retardant
IEC 60332 -1-2
Mechanical Resistance
Min. Bending Radius
RoHS
PHYSICAL AND ELECTRICAL PROPERTIES
Overall
Nominal
cross-section diameter
approx.
mm2
Net weight
approx.
Delivery Delivery drum Conductor DC Operating
length
resistance inductance
type
at 20°C
approx
Operating
capacity
approx
Current carrying capacity in (30°C)
Earth
Air
mm
kg/km
m
cm
Ω / km (max.)
mH/km
MF/km
A
A
49
52
57
60
64
67
71
77
83
3640
4200
5150
6200
7150
8250
9600
10650
14050
500
500
500
500
500
500
500
250
250
200
210
220
220
240
240
260
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.22
0.24
0.28
0.31
0.34
0.36
0.40
0.45
0.51
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
6/10 kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
76
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSEYFGY
PHYSICAL AND ELECTRICAL PROPERTIES
Overall
Nominal
cross-section diameter
approx.
mm2
Net weight
approx.
Delivery Delivery drum Conductor DC Operating
length
resistance inductance
type
at 20°C
approx
mm
kg/km
m
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16rm
3x150/25rm
3x185/25rm
3x240/25rm
3x300/25rm
55
58
62
66
69
73
77
83
89
4200
4800
5750
6850
7850
8950
10300
12450
14900
500
500
500
500
250
250
250
250
250
12/20 (24) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
60
63
67
71
74
78
87
88
93
4750
5350
6350
7450
8450
9600
11000
13200
15700
500
500
500
500
250
250
250
250
250
72
75
79
83
86
90
94
100
106
6250
6900
7950
9100
10200
11400
12900
15200
17800
250
250
250
250
250
250
250
250
250
mH/km
MF/km
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
220
220
240
260
210
220
240
240
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
210
220
220
240
240
260
260
280
300
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
cm
Ω / km (max.)
Operating Current carrying capacity in (30°C)
capacity
Earth
Air
approx
A
A
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.40
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.33
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
8.7/15 (17.5) kV
210
220
220
240
200
210
220
240
260
18/30 (36) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
20.3/35 (42) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
77
80
84
88
91
95
99
105
110
6900
7600
8650
9850
10950
12150
13700
16000
18550
250
250
250
250
250
250
250
250
250
220
220
240
240
260
260
280
300
300
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
77
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSEYBY
CONSTRUCTION
1
2
3
4
5
6
7
8
9
10
Copper conductor (class 2)
Inner semi conductive layer
XLPE insulation
Outer semi conductive layer
Semi conductive crepe paper
Copper tape screen
PP filler
PVC separation sheath
Galvanized double steel tape
PVC outer sheath
10
9
8 7 6 5 4
3 2 1
SPECIFICATIONS
Code
Standards
Rated voltage
: N2XSEYBY
: VDE 0273 IEC 60502-2
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Application
:
On this cable, electrical losses are minimized. Used for supplying
power for populated and industrial regions, networks having
voltage increase risk; can be installed in underground, indoor,
outdoor and also in cable channel applications. The armour in
the structure makes the cable necessary where there is
mechanical stress risk.
C
90
r
250
-20 / +60 C
r=15 x D
o
Temperature Range
Max. Operation
Temperature
Short Circuit
Temperature
Flame Retardant
IEC 60332 -1-2
Mechanical Resistance
Min. Bending Radius
RoHS
PHYSICAL AND ELECTRICAL PROPERTIES
Overall
Nominal
cross-section diameter
approx.
mm2
mm
6/10 kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
78
49
52
57
60
64
67
71
77
84
Net weight
approx.
kg/km
3400
4000
4900
5900
6850
7900
9250
11300
14450
Delivery Delivery drum Conductor DC Operating
length
resistance inductance
type
at 20°C
approx
m
Ω
/ km (max.)
mH/km
cm
500
500
500
500
500
500
500
250
250
200
210
220
220
240
240
260
220
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
Operating
capacity
approx
MF/km
0.22
0.24
0.28
0.31
0.34
0.36
0.40
0.45
0.51
Current carrying capacity in (30°C)
Earth
Air
A
A
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSEYBY
PHYSICAL AND ELECTRICAL PROPERTIES
Overall
Nominal
cross-section diameter
approx.
mm2
Net weight Delivery
length
approx.
Delivery drum Conductor DC Operating
resistance inductance
type
at 20°C
approx
mm
kg/km
m
cm
Ω / km (max.)
mH/km
55
58
62
66
69
73
77
84
90
3950
4550
5450
6500
7500
8600
9900
12800
15300
500
500
500
500
250
250
250
250
250
210
220
220
240
200
210
220
240
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.29
Operating
capacity
approx
Current carrying capacity in (30°C)
Earth
Air
A
A
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.40
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
MF/km
8.7/15 (17.5) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
12/20 (24) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
60
62
67
70
74
77
83
89
95
4450
5050
6000
7100
8100
9200
11350
13600
16100
500
500
500
500
250
250
250
250
200
220
220
240
240
210
220
240
260
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.27
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
18/30 (36) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
72
75
79
84
88
91
95
101
107
5900
6500
7550
9500
10600
11800
13300
15600
18250
250
250
250
250
250
250
250
250
250
210
220
220
240
240
260
260
280
300
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
20.3/35 (42) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
77
80
85
89
93
96
100
106
112
6500
7200
9050
10250
11400
12600
14200
16500
19200
250
250
250
250
250
250
250
250
250
220
220
240
260
260
260
280
300
320
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
79
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSEYRY
CONSTRUCTION
1
2
3
4
5
6
7
8
9
10
Copper conductor (class 2)
Inner semi conductive layer
XLPE insulation
Outer semi conductive layer
Semi conductive crepe paper
Copper tape screen
PP filler
PVC separation sheath
Galvanized round steel wire
PVC outer sheath
10
9
7 6 5 4
8
3 2 1
SPECIFICATIONS
Code
Standards
Rated voltage
: N2XSEYRY
: VDE 0273
: Uo/U=6/10 kV
Uo/U=8.7/15 kV
Uo/U=12/20 kV
Uo/U=18/30 kV
Uo/U=20.3/35 kV
C
Application
:
On this cable, electrical losses are minimized. Used for supplying
power for populated and industrial regions, networks having
voltage increase risk; can be installed in underground, indoor,
outdoor and also in cable channel applications. The armour in
the structure make the cable necessary where there is
mechanical stress risk.
C
90
r
250
-20 / +60 C
r=15 x D
o
Temperature Range
Max. Operation
Temperature
Short Circuit
Temperature
Flame Retardant
IEC 60332 -1-2
Mechanical Resistance
Min. Bending Radius
RoHS
PHYSICAL AND ELECTRICAL PROPERTIES
Overall
Nominal
cross-section diameter
approx.
mm2
Net weight Delivery
length
approx.
mm
kg/km
m
53
56
60
64
68
71
76
83
88
5000
5650
6750
7850
9000
10100
12450
14800
17450
500
500
500
500
500
500
250
250
250
Delivery drum Conductor DC Operating
resistance inductance
type
at 20°C
approx
cm
Ω / km (max.)
mH/km
Operating
capacity
approx
MF/km
Current carrying capacity in (30°C)
Earth
Air
A
A
6/10 kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
80
210
220
220
240
240
260
220
240
240
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.22
0.24
0.28
0.31
0.34
0.36
0.40
0.45
0.51
154
181
220
263
298
332
374
431
492
172
205
253
307
352
397
453
529
608
MEDIUM AND HIGH VOLTAGE POWER CABLES
N2XSEYRY
PHYSICAL AND ELECTRICAL PROPERTIES
Overall
Nominal
cross-section diameter
approx.
Net weight
approx.
Delivery Delivery drum Conductor DC Operating
length
resistance inductance
type
at 20°C
approx
Operating
capacity
approx
Current carrying capacity in (30°C)
Earth
Air
A
A
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.35
0.40
154
181
220
263
298
332
374
431
608
172
205
253
307
352
397
453
529
608
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.16
0.18
0.20
0.22
0.24
0.26
0.28
0.31
0.34
154
181
220
263
298
332
374
431
608
172
205
253
307
352
397
453
529
608
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.13
0.14
0.16
0.17
0.18
0.20
0.21
0.23
0.25
154
181
220
263
298
332
374
431
608
172
205
253
307
352
397
453
529
608
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.47
0.45
0.42
0.40
0.39
0.37
0.36
0.34
0.33
0.11
0.12
0.14
0.15
0.16
0.17
0.19
0.21
0.23
154
181
220
263
298
332
374
431
608
172
205
253
307
352
397
453
529
608
mm2
mm
kg/km
m
cm
Ω / km (max.)
mH/km
MF/km
8.7/15 (17.5) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
58
61
66
69
74
78
82
88
94
5750
6400
7500
8700
9800
11800
13400
15800
18500
500
500
500
500
500
250
250
250
250
220
220
240
240
260
220
240
240
260
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.39
0.37
0.35
0.33
0.32
0.31
0.30
0.29
0.29
12/20 (24) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
63
66
71
76
80
83
86
93
99
6450
7150
8200
10300
11450
12700
14200
16700
19500
500
500
500
250
250
250
250
250
250
220
240
260
220
220
240
240
260
280
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
18/30 (36) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16rm
3x150/25rm
3x185/25rm
3x240/25rm
3x300/25 rm
77
80
84
88
92
95
99
105
111
9100
9900
11100
12500
13700
15050
16700
19250
22100
250
250
250
250
250
250
250
250
250
220
220
240
240
260
260
280
300
320
20.3/35 (42) kV
3x35/16 rm
3x50/16 rm
3x70/16 rm
3x95/16 rm
3x120/16 rm
3x150/25 rm
3x185/25 rm
3x240/25 rm
3x300/25 rm
82
84
89
93
96
99
104
109
115
9900
10700
11950
13300
14600
15900
17700
20150
23000
250
250
250
250
250
250
250
250
250
240
240
260
260
260
280
300
300
320
81
MEDIUM AND HIGH VOLTAGE POWER CABLES
2XS(FL)2Y
CONSTRUCTION
1
2
3
4
5
6
7
8
9
10
Copper conductor (class 2)
Inner semi conductive layer
XLPE insulation
Outer semi conductive layer
Semi conductive water blocking tape
Concentric conductor
Copper tape
Water swelling tape
Copolimer aluminium tape
Polyethylene outer sheath
10
9 8 7 6 5
4
3
2
1
SPECIFICATIONS
Code
Standards
Rated voltage
: 2XS(FL)2Y
: IEC 60840 Test Standards
: Uo/U=26/45 kV
Uo/U=38/66 kV
Uo/U=64/100 kV
Uo/U=89/154 kV
C
Application
:
Used to transmit energy from power centres to national and
international interconnection networks, at connection of cities
to central distribution systems, also used in special premises
where over head lines are not permitted such as city centres
due to safety and environmental regulations. Additionally, this
cable is completely waterproof.
C
90
r
250
-20 / +60 C
r=15 x D
o
Temperature Range
Max. Operation Temperature
Short Circuit Temperature
Flame Retardant
IEC 60332 -1-2
Min. Bending Radius
RoHS
PHYSICAL AND ELECTRICAL PROPERTIES
Overall
Nominal
cross-section diameter
approx.
mm2
Net weight
approx.
Delivery Delivery drum Conductor DC Operating
length
resistance inductance
type
at 20°C
approx
mm
kg/km
m
cm
53
62
67
5300
6100
7200
500
500
500
80
83
88
12200
14000
16000
89
93
97
95
99
103
Operating
capacity
approx
Current carrying capacity in (30°C)
Earth
Ω / km (max.)
mH/km
MF/km
A
210
220
240
0.0601
0.0470
0.0366
0.37
0.35
0.33
0.20
0.22
0.24
598
673
759
250
250
250
240
240
240
0.0283
0.0221
0.0176
0.48
0.46
0.43
0.19
0.21
0.24
764
896
931
13300
15100
17200
250
250
250
260
260
280
0.0283
0.0221
0.0176
0.59
0.57
0.55
0.18
0.19
0.21
821
902
968
14200
15900
18100
250
250
250
260
280
280
0.0283
0.0221
0.0176
0.69
0.68
0.66
0.16
0.18
0.19
1080
1220
1355
26/45 (52) kV
1x300/35 rm
1x400/35 rm
1x500/50 rm
38/66 (76) kV
1x630/135 rm
1x800/135 rm
1x1000/135 rm
64/110 (123) kV
1x630/135 rm
1x800/135 rm
1x1000/135 rm
89/154 (175) kV
1x630/135 rm
1x800/135 rm
1x1000/135 rm
• Since construction of these cables are individually prepared on project basis,please contact with our company for further information.