GVU34RS UHF VHF OUT GVU 24RS GVU 34RS GV2U 28RS 10 ÐÏÉÏÔÇÔÁ +ÔÅ×ÍÏËÏÃÉÁ = MATEL GV2U 32RS GVU 34RS log Êåñáßá UHF 1 ìÝôñï Êåñáßá UHF 1 ìÝôñï Êåñáßá VHF 0,6 ìÝôñá ðñüò TV ANT OUT1 OUT2 UHF UHF VHF GV2U32RS Êåñáßá VHF Êåñáßá UHF OUT Êåñáßá UHF áðü ôéò Êåñáßåò Ôñïöïäïôéêü ANT Ðñüò ôï ôñïöïäïôéêü OUT1 OUT2 Ôñïöïäïôéêü ÓÕÍÄÅÓÇ ÔÑÏÖÏÄÏÔÉÊÏÕ - ÑÕÈÌÉÓÅÉÓ ÅÍÉÓ×ÕÔÇ ¼ôáí ðáñáôçñÞóïõìå óôçí ôçëåüñáóç üôé ï Ýíáò óôáèìüò “ìðáßíåé” ìÝóá óôïí Üëëï Þ üôé õðÜñ÷åé ìßá êáôáêüñõöç ìðÜñá ðïõ ìåôáêéíåßôáé, áõôü óçìáßíåé üôé ï åíéó÷õôÞò õðåñïäçãåßôáé. Ôï ðñüâëçìá äéïñèþíåôáé áí ìåéþóïõìå ôçí åíßó÷õóç ôïõ åíéó÷õôÞ. Ãé áõôü óôñÝöïõìå ôï áíôßóôïé÷ï trimmer áñéóôåñüóôñïöá, ìÝ÷ñé íÜ êáèáñßóåé ç åéêüíá. Óå êáíïíéêÝò óõíèÞêåò ôá trimmer ðñÝðåé íá åßíáé ôåëåßùò äåîéÜ (ìåãßóôç åíßó÷õóç). ÓÕÍÄÅÓÇ ÏÌÏÁÎÏÍÉÊÇÓ ÃÑÁÌÌÇÓ ÓÅ ÖÉÓ TV 4 3 1 5 2 4 11 R GV2U 28RS/F electronics 102dBìV VHF III UHF UHF OUT electronics PS1/F POWER INDOOR USE ONLY 230V AC 50Hz-3VA max. FUSE 32mA(FAST BLOW) DISCONNECT MAINS BEFORE OPENING COVER IN OUT1 OUT2 GVU 15RS/F GVU 34RS/F GV2U 28RS/F GV2U 32RS/F GVU 45RS/F 12 ÐÏÉÏÔÇÔÁ +ÔÅ×ÍÏËÏÃÉÁ = MATEL Êåñáßá UHF 1 ìÝôñï Êåñáßá UHF 1 ìÝôñï Êåñáßá VHF GV2U 32RS/F electronics 106dBìV UHF UHF OUT VHF III 0,6 ìÝôñá R Power Supply PS1/F electronics POWER INDOOR USE ONLY 230V AC 50Hz-3VA max. FUSE 32mA(FAST BLOW) DISCONNECT MAINS BEFORE OPENING COVER IN OUT1 OUT2 ðñüò TV áðü ôéò Êåñáßåò Ôñïöïäïôéêü R GV2U 32RS/F electronics UHF VHF III Êåñáßá UHF Êåñáßá UHF Êåñáßá VHF 106dBìV UHF OUT R Power Supply PS1/F electronics POWER INDOOR USE ONLY 230V AC 50Hz-3VA max. FUSE 32mA(FAST BLOW) DISCONNECT MAINS BEFORE OPENING COVER IN Ðñüò ôï ôñïöïäïôéêü OUT1 OUT2 Ôñïöïäïôéêü 13