Ôå÷íéêÜ ÷áñáêôçñéóôéêÜ / Technical Specifications Æþíåò / Zones 4 Áñéèìüò Ãñáììþí ÓåéñÞíùí / Alarm Lines 2 ÔÜóç Æþíçò / Zone Voltage 30V DC ÔÜóç Ãñáììþí ÓåéñÞíùí / Alarm Line Voltage 24V DC +5% / -5% Ðáñï÷Þ ÔÜóçò Äéêôýïõ / Power supply 230V +10% / -15% ÔåñìáôéêÝò ÁíôéóôÜóåéò Æùíþí-Ãñáììþí ÓåéñÞíùí / Terminal Resistors on Zones - Alarm Lines 12KÙ ÌÝãéóôïò Áñéèìüò Áíé÷íåõôþí áíÜ Æþíç / Maximum number of Detectors per Zone 20 ÌÝãéóôï öïñôßï óå ÃñáììÝò ÓåéñÞíùí / Maximum load on Alarm Lines 400mA áíÜ ãñáììÞ 800 mA óõíïëéêü / 400mA per line, 800 mA total ÌÝãéóôï öïñôßï âïçèçôéêÞò ôñïö/óßáò (AUX 12V 24V) / Maximum load on AUX 12V - 24V 800mA max ÂïçèçôéêÞ ¸îïäïò ÓöÜëìáôïò / General Fault Output 50mA 0V ÂïçèçôéêÞ ¸îïäïò ÓÞìáôïò ÖùôéÜò / General Fire Output ¸îïäïò relay / Relay Output ÂïçèçôéêÝò ¸îïäïé ÓÞìáôïò ÖùôéÜò áíÜ æþíç / Fire Outputs per Zone Ðñïãñáììáôéæüìåíç áíÜëïãá ìå ôç ëåéôïõñãßá ôïõ ðßíáêá / Programmable according to the panel’s operational mode ÅöåäñéêÞ Ôñïöïäïóßá (Ìðáôáñßá) / Backup Power (battery) 1x7,2Ah ×ñüíïò Öüñôéóçò / Battery Charge time 24h ×ñüíïò Áõôïíïìßáò / Backup power autonomy 72h ÄéáóôÜóåéò Ðßíáêá / Panel Dimensions 250mm x 250mm x 60mm Åããýçóç / Guarantee 3 ÷ñüíéá / 3 years FP400 MID810 Êùäéêïß ðáñáããåëßáò / Order Codes Ðßíáêáò ðõñáíß÷íåõóçò 4 æùíþí ÷ùñßò ìðáôáñßá / 4 zone fire detection control panel without battery Áíé÷íåõôÞò êáðíïý éïíéóìïý / Ionization smoke detector Áíé÷íåõôÞò êáðíïý öùôïçëåêôñéêüò / Photoelectric smoke detector Áíé÷íåõôÞò êáðíïý èåñìïäéáöïñéêüò / Fast response heat detector MPD820 MFR830 o o MHT890 Áíé÷íåõôÞò óôáèåñÞò èåñìïêñáóßáò 90 C / High temp response heat detector 90 C o 60 C / MMT860 Èåñìïäéáöïñéêüò óôáèåñÞò èåñìïêñáóßáò ÊÅÍÔÑÉÊÁ Medium response heat detector 60 oC MDB800 ÊïéíÞ âÜóç áíé÷íåõôþí / Common mounting base for detectors Êüìâïò Êïñéíïý, Ô.È. 48, 601 00 Êáôåñßíç Ôçë.: 23510-41200 - Fax: 23510-42057 CX3000 Äéáêüðôçò áíáããåëßáò öùôéÜò ìå åðáíáöåñüìåíï ðëáóôéêü / Web site: www.univel.gr Resetable plastic call point e-mail: [email protected] CXY3000 Äéáêüðôçò êáôÜóâåóçò ìå åðáíáöåñüìåíï ðëáóôéêü / ÃÑÁÖÅÉÁ ÁÈÇÍÙÍ Resetable plastic extinguishing call point ÄñÜìáò 1 & Ãñßâá - ¢ã. ÁíÜñãõñïé Ô.Ê. 135 61 FLASHNI ÖáñïóåéñÞíá 18-30Vdc ìå ëÜìðá xenon / Ôçë.: 210-2639820 - Fax: 210-2639821 Combined sounder beacon with xenon tube 18-30Vdc e-mail: [email protected] MBM246 Êïõäïýíé 24Vdc / Fire alarm bell 24Vdc HEAD OFFICE FL24 Åíäåßêôçò êéíäýíïõ / Åmergency indicator Komvos Korinou, P.O. BOX 48, 601 00 Katerini, GREECE D8080N ÅðáíáëÞðôçò Ýíäåéîçò óõíáãåñìïý / Led remote indicator Ôel.: +30 23510-41200 - Fax: +30 23510-42057 MGD8023 Áíé÷íåõôÞò áåñßùí (ðáñáãþãùí ðåôñåëáéïåéäþí) / LPG gas detector Web site: www.univel.gr e-mail: [email protected] Ìðïõôüí áêýñùóçò / Cancel button ES100 ATHENS BRANCH ÐëáêÝôá ìå 4 relay ãéá fp400 / 4 relay board for fp400 FP402 1, Dramas str. & Grivas str., 135 61 Aghii Anargiri ÐëáêÝôá åðéôçñïýìåíçò êáôÜóâåóçò / FP403 Tel.: +30 210-2639820 - Fax: +30 210-2639821 Board for extinguishing line monitoring e-mail: [email protected] ÐÉÍÁÊÁÓ ÐÕÑÁÍÉ×ÍÅÕÓÇÓ 4 ÆÙÍÙÍ 4 ZONE FIRE DETECTION PANEL ÔÝóóåñéò ðëÞñùò åëåã÷üìåíåò Zþíåò ìå äõíáôüôçôá áíåîÜñôçôçò ëåéôïõñãßáò äïêéìÞò / áðåíåñãïðïßçóçò (Test / Disable) áíÜ Æþíç. Four fully controlled Zones with test/disable capabilities per zone. Äýï ðëÞñùò åëåã÷üìåíåò ÃñáììÝò ÓåéñÞíùí ìå äõíáôüôçôá áíåîÜñôçôçò áðåíåñãïðïßçóçò (Disable) áíÜ ÃñáììÞ. 2 fully controlled Alarm Lines with disable capability per line. 24V/800mA ôñïöïäïôéêü ìå ìðáôáñßá åöåäñåßáò 12V/7,2Ah ãéá 72 þñåò áõôïíïìßáò. 24V/800mA Power Supply with a 12V/7.2Ah backup Battery for 72 hours autonomy. ÂïçèçôéêÝò Ýîïäïé ôÜóçò 12V-24V DC. 12V-24V Auxiliary Output Voltages. Ôñåéò êáôáóôÜóåéò ëåéôïõñãßáò: Ðõñáíß÷íåõóç, Áíß÷íåõóç áåñßùí, ÊáôÜóâåóç. Three operation modes: Fire detection , Gas Detection , Extinguish. Äéáöïñïðïßçóç Ýíäåéîçò áíïéêôÞò/âñá÷õêõêëùìÝíçò ãñáììÞò óôéò Æþíåò/ÃñáììÝò óåéñÞíùí ãéá åõêïëüôåñç åãêáôÜóôáóç êáé óõíôÞñçóç. Differentiation on of indication in open / short state of Zones /Alarm Lines for easiest fault recognition during installation / maintenance. Äõíáôüôçôá åíåñãïðïßçóçò óåéñÞíùí áðü åîùôåñéêü äéáêüðôç. Alarm Line activation by an external switch (Class Change operation) . Äõíáôüôçôá ðñïãñáììáôéóìïý êáèõóôÝñçóçò åíåñãïðïßçóçò óåéñÞíùí Ýùò 2 min ìå âÞìá 15 sec. Alarm Line activation Delay programming capability to approximately 2 min by 15 sec step. ÐáñÜêáìøç êáèõóôÝñçóçò áðü Ìðïõôüí / äéðëÞ åíåñãïðïßçóç æþíçò. Alarm Line activation delay override by Call Point / Double sensor activation in any single Zone. Äõíáôüôçôá ðñïãñáììáôéóìïý ðáñÜëëçëçò Þ åíáëëáóóüìåíçò ëåéôïõñãßáò ôùí ãñáììþí óåéñÞíùí. Programmable operation of alarm lines in parallel or alternative mode. Ó÷åäéáóìÝíïò óýìöùíá ìå ôá ÅÍ 54-2 & 4. Designed according to the ÅÍ 54-2 & 4. ÊáôáóôÜóåéò ëåéôïõñãßáò / Operation modes D8080N (optional) + MPD820 2 1 2 OUT 470 1 1 +OUT 1 MMT860 - CX3000 2 2 1 +OUT IN 470 CX3000 1 C5 Terminal resistor 12kÙ FLASHNI (50mA) 1 - L1 L1 C6 C5 MGD8023 MGD8023 C6 MGD8023 C5 MGD8023 L1 L1 L1 L1 L1 L1 C6 C5 C6 C5 C6 C5 CX3000 OUT 470 1 IN 470 - L1 L1 1 L1 L1 MGD8023 - Z1 + - Z2 + - Z3 + - AL1 + - AL2 + - Z4 + C6 C5 2 Terminal resistor 12kÙ L1 C6 C5 MGD8023 IN 9300 C6 L1 L1 L1 L1 C6 C5 C6 C5 C6 C5 - Z1 + 2 C5 MGD8023 MGD8023 L1 L1 - IN 470 L1 C5 C6 FLASHNI (50mA) C5 MGD8023 L1 C5 - - Z2 + - Z3 + - AL1 + - Z4 + FP400 B FP402 NO COM COM 2 NO NC Z ONC NE 24V COM 1 NO 12V GND - AL2 + ZONE 4 FIRE (0 VOLT) ZONE 3 FIRE (0 VOLT) D Áõôüìáôç ÊáôÜóâåóç ìå ôç ÷ñÞóç ôçò ðëáêÝôáò åðÝêôáóçò FP403 / Extinguish by using the FP403 extension board C B NO Åðéôçñïýìåíç ãñáììÞ êáôÜóâåóçò / Monitored extinguishing line FP400 COM NC - 1 1 1 2 2 2 FLASHNI (50mA) - 1 MMT860 MFR830 2 2 2 2 2 1 NC2 ES100 Solenoid Valve or Detonator / ÇëåêôñïâÜíá Þ ÐõñïêñïôçôÞò (24V) 2 2 ES100 Cancel button 1 (input) NC1 1 NC2 1 1 1 2 2 1 1 2 2 - Z2 + - Z3 + - Z4 + - AL1 + General Fault (Output 0V) manual extinguishing Terminal diode / ÔåñìáôéêÞ äßïäïò 2 - AL2 + Terminal PCB C 12V GND 2 2 - Z1 + EXT - + - Z2 + - Z3 + - Z4 + FP400 D B NO COM NC Detonator/ ÐõñïêñïôçôÞò + + MBM246 FL24 1 NC1 1 NC2 FP403 FP400 NC 24V 1 FIRE FLASHNI (50mA) - C NO COM 2 1 + MBM246 - MID810 B Extinguish ( output 0V) FIRE ES100 Þ/or D + - D8080N (optional) 2 2 2 MMT860 MFR830 - MHT890 2 Solenoid Valve / ÇëåêôñïâÜíá + - - 2 FL24 FLASHNI (50mA) 1 MPD820 2 D8080N (optional) General Fire with delay (Output 0V) 1 NC1 - FL24 - Z1 + 2 + MID810 D8080N (optional) Terminal resistor 12kÙ FIRE - +IN OUT 9300 CXY3000 IN 9300 C 1 2 1 MID810 2 EXT IN 2 1 PYRO IN 1 2 - 1 Ìðïõôüí OUT 470 CXY3000 IN 470 + 2 + - + 1 +OUT GND MHT890 Ìðïõôüí OUT 470 CXY3000 IN 470 Terminal resistor 12kÙ OUT 470 CXY3000 IN 470 +IN +OUT +IN D FIRE 1 Terminal resistor 12kÙ +IN 24V 1 MPD820 - Ìðïõôüí OUT 470 CXY3000 IN 470 12V OUT 9300 CXY3000 IN 9300 + MBM246 1 - FL24 Terminal resistor 12kÙ MBM246 1 MID810 FLASHNI (50mA) Terminal resistor 12kÙ +OUT + 1 Ìðïõôüí OUT 470 CXY3000 IN 470 - +IN + 1 +OUT + Ìðïõôüí OUT 470 CXY3000 IN 470 Terminal resistor 12kÙ OUT 470 CXY3000 IN 470 +IN +OUT Terminal resistor 12kÙ +IN auto extinguishing Ìðïõôüí OUT 470 CXY3000 IN 470 +IN +OUT +OUT Ìðïõôüí OUT 9300 CXY3000 IN 9300 +OUT +IN +OUT + Ìðïõôüí OUT 9300 CXY3000 IN 9300 Terminal resistor 12kÙ +IN +OUT Terminal resistor 12kÙ +IN + +IN +OUT +OUT + Áõôüìáôç ÊáôÜóâåóç / Extinguish Terminal resistor 12kÙ Terminal resistor 12kÙ 24V GND manual extinguishing C COM 3 NO + 12V auto extinguishing D Z ONC NE GND Solenoid Valve 1 / ÇëåêôñïâÜíá 1 (24V) Åðéôçñïýìåíç ãñáììÞ ìðïõôüí áêýñùóçò êáôÜóâåóçò / Monitored Cancel button line - AL2 + 24 V ZONE 1 FIRE (0 VOLT) Terminal resistor 12kÙ - AL1 + - Z4 + C5 ZONE 2 FIRE (0 VOLT) Terminal resistor 12kÙ COM 4 NO Z ONC NE L1 C6 Solenoid Valve 2 / ÇëåêôñïâÜíá 2 (24V) Ðñïãñáììáôéóìüò ðßíáêá óå Mode (3) 1. Äéáêüðôïõìå ôéò ôñïöïäïóßåò ôïõ ðßíáêá áöáéñþíôáò ôéò áóöÜëåéåò ôùí 230VAC êáé ôçò ìðáôáñßáò. 2. ÐéÝæïõìå êáé êñáôÜìå ðáôçìÝíï ôï ðëÞêôñï 3. 3. Åðáíáôïðïèåôïýìå ôçí áóöÜëåéá 230VAC. 4. Áöïý áíÜøåé ç Ýíäåéîç (zone 3 fire) áöÞíïõìå ôï ðëÞêôñï 3. 5. Åðáíáôïðïèåôïýìå ôçí áóöÜëåéá ôçò ìðáôáñßáò. Programming panel in mode (3) 1. Cut off power supplies by removing 230VAC mains and battery fuse. 2. Press continuously key 3. 3. Place back 230VAC mains fuse. 4. Once indication (zone 3 fire) is switched on release key 3. 5. Put the battery fuse back on. - Z3 + 24VDC GRD + - MGD8023 L1 C6 + - L1 - Z1 + C6 FIRE ¸îïäïé Relay áíá æþíç Relay outputs per zone + C6 L1 Terminal resistor 12kÙ CX3000 L1 MGD8023 C5 - FLASHNI (50mA) OUT 470 L1 MGD8023 C6 - +IN +OUT 2 2 - Z2 + + Z ONC NE 2 MFR830 L1 - L1 Terminal resistor 12kÙ + MHT890 MID810 2 C5 1 Terminal resistor 12kÙ 1 1 + 1 FLASHNI (50mA) C5 MGD8023 L1 12VDC L1 C6 1 - GND MBM246 CX3000 + 24 V MPD820 L1 Terminal resistor 12kÙ L1 FIRE + - MGD8023 Áíß÷íåõóç Áåñßùí (¸îïäïò áíá æþíç) / Gas detection (Output per zone) +IN - L1 MGD8023 MGD8023 2 Terminal resistor 12kÙ FLASHNI (50mA) 2 2 MPD820 2 +OUT Terminal resistor 12kÙ OUT 9300 1 Terminal resistor 12kÙ 2 - + FP400 Ðñïãñáììáôéóìüò ðßíáêá óå Mode (2) 1. Äéáêüðôïõìå ôéò ôñïöïäïóßåò ôïõ ðßíáêá áöáéñþíôáò ôéò áóöÜëåéåò ôùí 230VAC êáé ôçò ìðáôáñßáò. 2. ÐéÝæïõìå êáé êñáôÜìå ðáôçìÝíï ôï ðëÞêôñï 2. 3. Åðáíáôïðïèåôïýìå ôçí áóöÜëåéá 230VAC. 4. Áöïý áíÜøåé ç Ýíäåéîç (zone 2 fire) áöÞíïõìå ôï ðëÞêôñï 2. 5. Åðáíáôïðïèåôïýìå ôçí áóöÜëåéá ôçò ìðáôáñßáò. Programming panel in mode (2) 1. Cut off power supplies by removing 230VAC mains and battery fuse. 2. Press continuously key 2. 3. Place back 230VAC mains fuse. 4. Once indication (zone 2 fire) is switched on release key 2. 5. Put the battery fuse back on. Terminal resistor 12kÙ MID810 MFR830 2 L1 + 1 L1 MGD8023 MGD8023 IN 9300 1 MHT890 2 L1 C6 - +IN L1 Terminal resistor 12kÙ +IN OUT 9300 2 + + 2 1 2 FIRE + - MFR830 2 - FLASHNI (50mA) + Terminal resistor 12kÙ MID810 2 +IN +OUT + Terminal resistor 12kÙ 1 + Terminal resistor 12kÙ - 4 1 1 1 + 4 Terminal resistor 12kÙ 24V 12V GND - AL1 + - AL2 + MBM246 + Ðñïãñáììáôéóìüò ðßíáêá óå Mode (1) 1. Äéáêüðôïõìå ôéò ôñïöïäïóßåò ôïõ ðßíáêá áöáéñþíôáò ôéò áóöÜëåéåò ôùí 230VAC êáé ôçò ìðáôáñßáò. 2. ÐéÝæïõìå êáé êñáôÜìå ðáôçìÝíï ôï ðëÞêôñï 1. 3. Åðáíáôïðïèåôïýìå ôçí áóöÜëåéá 230VAC. 4. Áöïý áíÜøåé ç Ýíäåéîç (zone 1 fire) áöÞíïõìå ôï ðëÞêôñï 1. 5. Åðáíáôïðïèåôïýìå ôçí áóöÜëåéá ôçò ìðáôáñßáò. Programming panel in mode (1) 1. Cut off power supplies by removing 230VAC mains and battery fuse. 2. Press continuously key 1. 3. Place back 230VAC mains fuse. 4. Once indication (zone 1 fire) is switched on release key 1. 5. Put the battery fuse back on. Terminal resistor 12kÙ MBM246 Ðõñáíß÷íåõóç / Fire Detection Terminal resistor 12kÙ D8080N (optional)
© Copyright 2024 Paperzz