Schumann André Boucourechliev

Compensatore idraulico/collettore
5539X
Art.
Hydraulic compensator/boiler manifolds
Compensatore idraulico/collettore in acciaio con
coibentazione e staffe di fissaggio, interasse
circuiti 125 mm, attacchi con sede piana e
calotta 1”1/2.
Hydraulic compensator/boiler manifolds made of
steel with insulation and fixture brackets, 125 mm
circuits interaxis, couplings with flat end 1”1/2 cap.
www.tiemme.com
COPYRIGHT
The art. 5539X hydraulic compensator / steel manifolds is used in thermal power stations as a practical and compact solution
since it carries a dual function: the lower section performs the function of hydraulic compensator, and it separates the primary
circuit (heating) from the secondary circuit (user) correcting any differences in flow or pressure drop requirements, while the top
section serves as manifolds going from one side to power the secondary circuit and from the other to collect the flow return.
Article 5539X is insulated with a special cover made of cross linked polyethylene closed cell foam that allows an exellent thermal
insulation when using the heating system and when using the cooling system. Brackets for wall mounting are also provided
PORTATA MAX/
MAX FLOWRATE
CODICE/
CODE
SEZIONE/
SECTION
N.CIRCUITI/
CIRCUITS N.
557 0001
80 X 80
2
3 m3/h
557 0002
80 X 80
3
3 m3/h
557 0003
120 X 120
2
7 m3/h
557 0004
120 X 120
3
7 m3/h
557 0005
120 X 120
4
7 m3/h
Technical Description
Max operating temperature : 100°C
Max operating pressure: 4 bar
Caratteristiche Tecniche
Temperatura max di esercizio: 100°C
Pressione max di esercizio: 4 bar
Descrizione
Materiale
Description
Material
Corpo
Acciaio S235 zincato
Body
Steel S235 zinc-plated
Lower Mounts
For 80x80section.
1''1 / 2 M
For 120x120 section
2” M
Upper Mounts
Loose nut flat end seat 1''1 / 2
Insulating Cover
Foam polyethylene (PEX)
Attacchi inferiori:
per sez. 80x80
Per sez. 120x120
Attacchi superiori:
Guscio di coibentazione:
1”1/2 M
2” M
Dado folle a battuta piana 1”1/2
Polietilene reticolato espanso a
celle chiuse (PEX)
TIEMME Raccorderie S.p.A. si riserva di apportare modifiche in qualsiasi momento senza preavviso.
TIEMME Raccorderie S.p.A.reserves the right to modify contents inany time without prior advise.
È vietata qualsiasi forma di riproduzione, se non autorizzata.
Is forbidden any reproduction unless under TIEMME autorization
Il compensatore idraulico/collettore in acciaio art. 5539X
viene utilizzato nelle centrali termiche poiché rappresenta
una soluzione funzionale e compatta andando a svolgere
una doppia funzione: la parte inferiore permette di svolgere
la funzione di compensatore idraulico separando così
idraulicamente il circuito primario (generatore di calore)
dal circuito secondario (utilizzatore) compensando eventuali
differenze di portata o perdite di carico richieste, mentre
la parte superiore svolge la funzione di collettore andando
cosi da un lato ad alimentare il circuito secondario e dall'altro
a raccogliere il ritorno del fluido.
L'art. 5539X è coibentato con l'apposita custodia in polietilene reticolato espanso a cellule chiuse che permette un ottimo
isolamento termico sia quando si utilizza riscaldamento sia quando si utilizza il raffrescamento. Inoltre vengono fornite le
staffe per il fissaggio a muro.
TIEMME Raccorderie S.p.A.
Via Cavallera 6/A (Loc. Barco) - 25045 Castegnato (Bs) - Italy
Tel +39 030 2142211 R.A. - Fax +39 030 2142206
[email protected] - www.tiemme.com
©TIEMME Raccorderie S.p.A. 5539X Rev. C 10-12
1/6
5
Compensatore idraulico/collettore
5539X
Art.
Hydraulic compensator/boiler manifolds
Dimensioni
Codice Sezione AxA n. Circuiti
Code
Section AxA Circuits N.
557 0001
80x80
2
557 0002
80x80
3
557 0003
120x120
2
557 0004
120x120
3
557 0005
120x120
4
DIMENSIONI/DIMENSIONS
ØD
ØA
ØV
ØS
L
B
C
1''1/2 1''1/2 M 1/2''F 26,4
460
125 42,5
1''1/2 1''1/2 M 1/2''F 26,4
710
125 42,5
1''1/2 2'' M 1/2''F 26,9
515
125 70
1''1/2 2'' M 1/2''F 26,9
765
125 70
1''1/2 2'' M 1/2''F 26,9 1015 125 70
D
62
62
90
90
90
E
50
50
50
50
80
Peso [Kg]
Weight
[Kg]
5,1
7,3
10,6
15,0
19,6
DIMENSIONI/DIMENSIONS
Codice
Code
557 0001
557 0002
557 0003
557 0004
557 0005
Sezione AxA n. Circuiti
Section AxA Circuits N.
80x80
80x80
120x120
120x120
120x120
2
3
2
3
4
F
G
H
I
N
M
O
P
Portata
max.
[m3/h]
Max
flowrate
[m3/h]
22,5
22,5
22,5
22,5
22,5
70
70
100
100
100
130
130
195
210
210
200
450
125
345
595
60
60
95
110
110
47,5
47,5
77,5
77,5
77,5
15
15
15
15
15
50
50
50
50
50
3
3
7
7
7
Principio di Funzionamento
Operation
Il compensatore idraulico/collettore in acciaio viene utilizzato negli impianti di riscaldamento/raffrescamento per permettere differenti regolazioni
termiche dei vari ambienti a fronte della presenza di un solo generatore di calore o macchina frigorifera.
È un prodotto utilizzato soprattutto in centrali termiche che presentano dimensioni ridotte, infatti l'art. 5539X ha il vantaggio di avere 2 prodotti in 1:
-funzione di compensatore idraulico (parte inferiore);
TIEMME Raccorderie S.p.A. si riserva di apportare modifiche in qualsiasi momento senza preavviso.
TIEMME Raccorderie S.p.A.reserves the right to modify contents inany time without prior advise.
È vietata qualsiasi forma di riproduzione, se non autorizzata.
Is forbidden any reproduction unless under TIEMME autorization
Dimensions
-funzione di collettore (parte superiore).
Il compensatore idraulico trova utilizzo nei moderni impianti dove ad un circuito primario di produzione di acqua calda
(generatore di calore) o di acqua fredda (macchina frigorifera) dotato di propria pompa di circolazione viene associato uno o più circuiti di utilizzo
anche loro dotati di propria pompa di circolazione.
TIEMME Raccorderie S.p.A.
Via Cavallera 6/A (Loc. Barco) - 25045 Castegnato (Bs) - Italy
Tel +39 030 2142211 R.A. - Fax +39 030 2142206
[email protected] - www.tiemme.com
©TIEMME Raccorderie S.p.A. 5539X Rev. C 10-12
2/6
Compensatore idraulico/collettore
5539X
Art.
Hydraulic compensator/boiler manifolds
A questo punto possono nascere varie problematiche, innescate dalla differenza di pressione differenziale tra il circuito di produzione di acqua ed il
circuito di utilizzo, soprattutto se il secondo può facilmente variare la sua prevalenza.
Per risolvere queste problematiche basta frapporre tra i due circuiti il separatore idraulico, creando una zona a ridotta perdita di carico, che
permette di rendere idraulicamente indipendenti i circuiti ad esso collegati.
In questo caso, la portata che passa attraverso i rispettivi circuiti dipende esclusivamente dalle caratteristiche di portata delle pompe, evitando la
reciproca influenza dovuta al loro accoppiamento in serie.
Il collettore si trova a valle della zona di separazione idraulica e si hanno quindi i collettori di andata e ritorno a cui possono essere collegati i
vari circuiti di distribuzione secondari. La particolarità costruttiva è dovuta ad una geometria a sinusoide che permette di separare la
mandata con il ritorno. Ciascun circuito è pertanto indipendente l'uno dall'altro.
The hydraulic compensator / steel manifold is used in heating / cooling system to allow different temperature settings of the various rooms where there is only
one heat /refrigeration generator
This product is mainly used in power stations which are small in size , in fact art. 5539X has the advantage of having two products in one:
Hydraulic compensator (lower end ) function
Header (top end).function
The hydraulic compensator is used in modern air conditioning systems where the primary circuit of hot water (heating) or cold (refrigeration) which
has its own circulation pump is associated with one or more circuits also using their own circulation pump.
At this point, various problems may arise, triggered by the pressure difference between the differential circuit of water production and use of the
circuit, especially if the latter can easily vary its prevalence.
To resolve these issues one can simply interpose the separator between the two hydraulic circuits, creating a zone of low pressure drop, which
allows you to make independent hydraulic circuits connected to it.
In this case, the flow rate through the respective circuits depends exclusively on the characteristics of the pump, while avoiding the mutual influence
due to their coupling .
The manifolds are located downstream of the hydraulic separation zone and then you have the flow and return manifolds which can be connected
Each circuit is thus independent of each other
Di seguito riportiamo la rappresentazione grafica delle 3 condizioni di equilibrio idraulico che possiamo trovare all’interno del
compensatore idraulico/collettore:
Here below you may find the three different conditions of hydraulic balance of the hydraulic compensator/boiler manifold
(with calculation of the relevant temperature):
Qi > Qe
Qi = portata circuito primario
Qe
T4
T3
Qe
T4
primary circuit flow rate
T3
Qe= portata circuito secondario
secondary circuit flow rate
T1=Temperatura di mandata circuito primario
primary circuit supply temperature
T2= Temperatura di ritorno circuito primario
primary circuit return temperature
T3=Temperatura di mandata circuito secondario
secondary circuit supply temperature
T2
T1= T3
T2> T4
T1
Qi
T4= Temperatura di ritorno circuito secondario
TIEMME Raccorderie S.p.A. si riserva di apportare modifiche in qualsiasi momento senza preavviso.
TIEMME Raccorderie S.p.A.reserves the right to modify contents inany time without prior advise.
È vietata qualsiasi forma di riproduzione, se non autorizzata.
Is forbidden any reproduction unless under TIEMME autorization
to the various secondary distribution channels . The particular design is due to a sinusoidal geometry which separates the flow with the return.
secondary circuit return temperature
TIEMME Raccorderie S.p.A.
Via Cavallera 6/A (Loc. Barco) - 25045 Castegnato (Bs) - Italy
Tel +39 030 2142211 R.A. - Fax +39 030 2142206
[email protected] - www.tiemme.com
©TIEMME Raccorderie S.p.A. 5539X Rev. C 10-12
3/6
Compensatore idraulico/collettore
Hydraulic compensator/boiler manifolds
5539X
Art.
Qi < Qe
Qi = Qe
Qe
T4
T3
Qe
T4
T4
T3
T2
T1
T1= T3
T2= T4
Qe
Qe
T3
T4
T3
T2
T1
T1> T3
T2= T4
Qi
Qi
Installazione
Installation
The manifolds / compensator must be installed in compliance with the connections shown in the graphics.
Article. 5539X can be installed upside down but you need to keep the connections in mind
Mounts 1 / 2 "can be used to connect the fill valve and the exhaust valve when the system require it.
Art.2990
Rubinetto per carico acqua
Fill valve
Art.2990
Rubinetto per scarico acqua
Exhaust valve
TIEMME Raccorderie S.p.A. si riserva di apportare modifiche in qualsiasi momento senza preavviso.
TIEMME Raccorderie S.p.A.reserves the right to modify contents inany time without prior advise.
È vietata qualsiasi forma di riproduzione, se non autorizzata.
Is forbidden any reproduction unless under TIEMME autorization
Il collettore/compensatore deve essere montato rispettando i collegamenti rappresentati nella grafica.
L'art. 5539X può essere installato anche capovolto rispettando però i collegamenti.
Gli attacchi 1/2” possono utilizzati per collegare la valvola di carico e la valvola di scarico qualora l'impianto lo richiedesse.
TIEMME Raccorderie S.p.A.
Via Cavallera 6/A (Loc. Barco) - 25045 Castegnato (Bs) - Italy
Tel +39 030 2142211 R.A. - Fax +39 030 2142206
[email protected] - www.tiemme.com
©TIEMME Raccorderie S.p.A. 5539X Rev. C 10-12
4/6
Compensatore idraulico/collettore
Hydraulic compensator/boiler manifolds
5539X
Art.
Il collettore/compensatore viene fornito completo di apposite staffe di fissaggio a parete. I collettori/compensatori cod. 557 0003,
557 0004, 557 0005 presentato delle staffe più resistenti per supportare un peso maggiore ed è possibile inoltre regolare in profondità
il posizionamento. L'art. 5539X viene fornito completo di coibentazione in Polietilene reticolato espanso a celle chiuse (PEX). Permette un
ottimo isolamento termico e le caratteristiche di questo materiale e la conformazione della coibentazione non permettono all'aria di
posizionarsi tra il pezzo e la coibentazione. In tal caso, qualora si utilizzasse acqua refrigerata, si evita la formazione della condensa.
The compensator / manifolds come complete with brackets for wall mounting. code. 557 0003,
557 0004, 557 0005 stronger brackets to support more weight ,you can also adjust the positioning for more depth.
Article. 5539X comes complete with insulation cover in cross-linked polyethylene closed cell foam (PEX). It allows an excellent thermal
insulation and resistance. This kind of material and its shape do not allow air to flow inside therefore, if chilled water is used, condensation
is prevented.
Applicazione tipica
5539x
Impianto con caldaia a terra
System with floor standing boiler
TIEMME Raccorderie S.p.A. si riserva di apportare modifiche in qualsiasi momento senza preavviso.
TIEMME Raccorderie S.p.A.reserves the right to modify contents inany time without prior advise.
È vietata qualsiasi forma di riproduzione, se non autorizzata.
Is forbidden any reproduction unless under TIEMME autorization
ORIGINAL ITALIAN TRADEMARK
Tipical application
TIEMME Raccorderie S.p.A.
Via Cavallera 6/A (Loc. Barco) - 25045 Castegnato (Bs) - Italy
Tel +39 030 2142211 R.A. - Fax +39 030 2142206
[email protected] - www.tiemme.com
©TIEMME Raccorderie S.p.A. 5539X Rev. C 10-12
5/6
Compensatore idraulico/collettore
Hydraulic compensator/boiler manifolds
5539X
Art.
Applicazione tipica
Impianto con caldaia murale
System with wall-mounted boiler
5539x
ORIGINAL ITALIAN TRADEMARK
TIEMME Raccorderie S.p.A. si riserva di apportare modifiche in qualsiasi momento senza preavviso.
TIEMME Raccorderie S.p.A.reserves the right to modify contents inany time without prior advise.
È vietata qualsiasi forma di riproduzione, se non autorizzata.
Is forbidden any reproduction unless under TIEMME autorization
Tipical application
TIEMME Raccorderie S.p.A.
Via Cavallera 6/A (Loc. Barco) - 25045 Castegnato (Bs) - Italy
Tel +39 030 2142211 R.A. - Fax +39 030 2142206
[email protected] - www.tiemme.com
©TIEMME Raccorderie S.p.A. 5539X Rev. C 10-12
6/6