放 電 型 D-D 核 融 合 中 性 子 源 ~ (トランス)ポータブル中性子源 ~ <108 sec-1 (DC) <1010 sec-1 (Pulsed) ~数十cmφ 研究会 「On-site 中小規模中性子源」 平成17年11月18,19日 @京都大学化学研究所 京都大学エネルギー理工学研究所 増 田 開 2 Inertial Electrostatic Confinement Fusion (IECF) Concept by R.L. Hirsch, J. Appl. Phys., vol. 38, pp. 4522-4534, 1967. high voltage supply >109 sec-1 (D-T) @ 10mA, 150kV 6 ion guns support & pump 10-2 – 10-5 Torr Neutron yield was seen to increase as pressure reduces. 3 Glow-Discharge Based IECF Device as a (trans)portable neutron/proton source IECF (Inertial Electrostatic Confinement Fusion) 1 x 107 sec-1 (D-D) 4 IECF 中性子源 の 動作原理 ターゲット = ガス 真空容器(接地) メッシュ状陰極 (- 数十 kV) 5 6 Current World Status of Neutron Yield D-D Neutron/Proton Yield [sec-1] Kyoto U. UIUC UW, Madison LANL TIT Kansai U. Hitachi 1.1 ×107 (DC, 62 kV, 30 mA) 2.0 ×106 (DC) 7.0 ×108 (Pulse) 1.8 ×108 (DC, 180 kV, 67 mA) 1.6 ×108 (DC, D-3He) 1.0 ×106 (DC) 5.0 ×105 (DC) 6.8 ×109 (Pulse, 70 kV, 10 A) 2.6 ×106 (DC, 60 kV, 50 mA) 8.5 ×107 (Pulse, 35 kV, 4.5 A) 7.5 ×107 (DC) 7 人道的 対人地雷 探知・除去技術 研究開発推進事業 「アフガニスタンをはじめとして、現 在、世界には1億1千万個の地雷」 150-300 victims/month 「除去には、今のペースでは数百年 或いはそれ以上を要する」 「我が国政府においては、平成14 年1月のアフガニスタン復興支援 東京会議において研究開発を通じ た貢献を表明」 http://www.jst.go.jp/kisoken/jirai/ 要求条件 30g以上,深さ20cm,100 % 8 Landmine Detection Field Test Landmine detection Field Test in Kagawa, Japan, 25 Feb ’05 The vehicle has a detection system attached at the end of its long arm GPR detection system We are planning to take our test using IEC neutron source in 2006 9 中性子捕獲γ線による探知 中性子捕獲反応 元素に固有の波長 のγ線を放出 H, C, N, O 元素成分比を同定可能 10 IEC20 Device DC Neutron Source for Landmine Detection 200mm 4 x 106 sec-1 DC 65mm 11 IEC20 Operational Diagram Cathode current [ mA ] 80 6k W 70 5k W 60 4k W 50 3k W 40 Neutron yield 2.2x106 sec-1 @70kV, 30mA 2k W 30 1k W 20 4.4x106 sec-1 @100kV, 50mA 10 0 0 20 40 60 80 Cathode voltage [ kV ] 100 12 Experimental Rooms control room above pit pit entrance inside pit 13 Experimental Setup Detector IEC From center of IEC to melamine: 30 cm From surface of NaI to melamine: 12 cm Melamine(C3H6N6): 60~800g 30 cm 1 m c 2 Melamine 14 Detectors was covered with Pb sheet ← X-Ray Shield Melamine was covered with sand in boxes IEC was surrounded by polyethyelene ← Neutron reflector Detector was shielded by neutron absorber ← Protection of detectors from activation by neutrons 15 Gamma-Ray Spectrum at 2.2 x 106 sec-1(CW) 1.00E+05 H-2.22 MeV With melamine800g 5 point moving average Without melamine 5 point moving average N-14: 10.83MeV 1.00E+03 20 1.00E+02 18 16 14 12 1.00E+01 10 8 6 1.00E+00 4 205 204 203 202 201 200 199 198 197 196 195 194 193 192 191 190 189 188 187 0 186 2 185 Arbitrary Unit 1.00E+04 1.00E-01 0 2 4 6 8 10 12 Energy[MeV] Integration counts in this energy region were measured 16 Experimental Results at 2.2 x 106 sec-1 (CW) Total count in 10.8MeV region Amount of melamine With melamine W/O melamine Polyethylene blocks cover melamine 800 g 102 36 270 g 57 38 60 g 50 38 Soil blocks cover melamine 800 g 61 37 270 g 78 47 Count time 1000~1500 sec 17 ¾ D-D 中性子発生率 2x108 sec-1 (DC), 7x109 sec-1 (Pulse) ¾ 地雷探査用の超小型装置の開発 200mmφ,70kV, 30mA, 2x106 sec-1 (DC) ¾ 中性子による爆薬探知 D-D: 後方散乱中性子 → H 中性子捕獲γ線 → H, N D-T: 即発γ線 → H, N, O (関連粒子法適用可) ¾ フィールド試験(2006年冬に予定)に向けて 高中性子束化: > 107 sec-1 (DC) 検出系の高性能化 中性子源・検出器のモジュール化 遮蔽体,中性子源,検出器の最適配置
© Copyright 2024 Paperzz