Teledyne Analytical Instruments LGA 4000 Analyzer Teledyne Analytical Instruments Overview Theory of Operation Electromagnetic Spectroscopy Laser Tunable Diode Wavelength Selection LGA 4000 In-situ Analyzer LGA 4000 Extractive Analyzer Instrument Specifications Applications Teledyne Analytical Instruments 2 Theory of Operation Electromagnetic Spectroscopy E2 photon Electron Movement DE = hn Energy level transition E1 Nuclei Rotation Molecules absorb EM radiation Raise energy level of electrons at certain wavelengths Each molecule has unique frequency response Nuclei Vibration Teledyne Analytical Instruments 3 Theory of Operation Emit EM radiation through sample gas Measure absorbance A = log10 (Io/It) L I I 0 t Gas Beer Lambert Relationship – A=ε•b•c – ε=molar absorption – b=path length – c=gas concentration Teledyne Analytical Instruments 4 Theory of Operation Diode Laser Absorption Spectroscopy – “Monochromatic” bandwidth – Bandwidth 0.0001nm – Adjust laser temperature, current Teledyne Analytical Instruments 5 Theory of Operation Laser spectral scan is larger than gas absorption spectral line width Reference signal is compared to sample gas signal Calculation of T=Tb/Ta provides accurate concentration measurement Teledyne Analytical Instruments 6 Theory of Operation Teledyne Analytical Instruments 7 Theory of Operation Spectral analysis of background gases and sample gas Frequency must be found such that only sample gas is attenuated Teledyne Analytical Instruments 8 LGA 4000 In-Situ Analyzer Teledyne Analytical Instruments 9 LGA 4000 In-Situ Analyzer Teledyne Analytical Instruments 10 LGA 4000 Extractive Analyzer Teledyne Analytical Instruments 11 Analyzer Specifications In-Situ System Extractive System Optical Path Length: <= 15m Optical Path Length: 0.5m or 1.1m Response Time: <= 1s Response Time: <= 5s (T90) Linear Accuracy: <= +/-1% FS Gas Temperature: -30 to 140C Span Drift: <= +/- 1% FS Gas Pressure 0.5 to 3 Bara Calibration: 2/year Enclosure: IP65 Explosion Proof: Expxmd IICT5 Power: 24VDC/110VAC/220VAC Ambient Temperature: -30 to 60C Teledyne Analytical Instruments 12 Applications Gas LDL Range Gas LDL Range O2 0.01% Vol. 0-1% Vol., 0-100% Vol. CO 40 ppm 0-8000 ppm, 0-100% Vol. CO2 20 ppm 0-2000 ppm, 0-100% Vol. H2O 0.03 ppm 0-3 ppm, 0-70% Vol. H2S 2 ppm 0-200 ppm, 0-30% Vol. HF 0.01 ppm 0-1 ppm, 0-10000 ppm HCL 0.01 ppm 0-7 ppm, 0-8000 ppm HCN 0.2 ppm 0-20 ppm,0-1% Vol. NH3 0.1 ppm 0-10 ppm, 0-1% Vol. CH4 10 ppm 0-200 ppm, 0-10% Vol. C2H2 0.1 ppm 0-10 ppm, 0-70% Vol. C2H4 1.0 ppm 0-100 ppm, 0-70% Vol. Teledyne Analytical Instruments 13
© Copyright 2024 Paperzz