Contaminant Max Allowable Concentration

MultiRAE Gas Monitor or
equivalent Carbon
Monoxide Monitor
TSI Side Pak AM510 or
equivalent Particulate Sampler
Tripod stand and
sampling tray
Our LEED Certification Kit also includes:
t Single, sturdy Kit Case
Assay 580 Monitor
for Formaldehyde
Stainless canisters and
integrated regulators
for TVOC
t All-inclusive lab report
t Free shipping and 2nd Day Air delivery
to and from your location (within U.S.)
t Includes all accessories required
Contaminant
Max Allowable
Concentration
Sampling
Method
Sampling
Time
Total Air
Volume
Reporting
Limit
Formaldehyde
27 ppb
NIOSH 2016
Assay
580 monitor
4 or 8 hrs.
N/A
20 ppb – 4 hrs
10 ppb – 8 hrs
Particulates
50 ug/m3
direct read
instrument
N/A
Continuous
data logging
N/A
1 ug/m3
Total Volatile Organic
Compounds
4-PCH (media not
shown)
Carbon Monoxide
500 ug/m3
EPA TO-15
evacuated
canister
4 or 8 hrs.
440 ml
23.7 ug/m3
6.5 ug/m3
NIOSH 1501
226-01 tube
4 hr at 0.2lpm 48 L
8 hr at 0.2lpm 96 L
4.2 ug/m3
2.1 ug/m3
9 ppm and no greater
then 2 ppm above the
outside value
direct read
instrument
N/A
Continuous
data logging
0.1 ppm
Media
N/A
For more information about LEED testing, contact a Galson service
representative at 888-432-LABS or use our LIVE Online chat service
at www.galsonlabs.com. To view our LEED Kit video, go to
www.galsonlabs.com/services/leed/
ISO 17025:2005 accredited by AIHA
AIHA LAP, LLC
AIHA LAP, LLC
AIHA LAP, LLC
ACCREDITED LABORATORY
ACCREDITED LABORATORY
ACCREDITED LABORATORY
INDUSTRIAL HYGIENE
ISO/IEC 17025:2005
ENVIRONMENTAL LEAD
ISO/IEC 17025:2005
ENVIRONMENTAL MICROBIOLOGY
ISO/IEC 17025:2005
www.aihaaccreditedlabs.org
www.aihaaccreditedlabs.org
www.aihaaccreditedlabs.org
#100324
GalsonLAB
Lab
#100324
#100324
GalsonLAB
Lab
#100324
#100324
GalsonLAB
Lab
#100324
"*326"-*5:5&45*/(t-"#"/"-:4*4t-&&%$&35*'*$"5*0/t&26*1.&/53&/5"-t$"--$&/5&3t*/5&3/"5*0/"--:"$$3&%*5&%