OPEN 4 FAN 3 F 1/OPN 3 H 2/CLO 0-10V OUT OUTPUTS SWITCHED COM DAMPER OUT (USA) 019917-007 (CAN) 020171-001 0-10 COM COM CW CCW NOTE 1: TRANSFORMER SECONDARY COM MUST BE EARTH GROUNDED PRICE SUPPLIED ACTUATOR OPN 2 CLO 1 -24V COM COM +24V HOT NOTE 2: WIRES 1-6 ARE PLENUM RATED CABLES FOR 24VAC POWER AND CONTROL CIRCUITS MAX 10VA PER CONTACTOR *STAGES 2 AND 3 ARE OPTIONAL C 24VAC BINARY OUTPUTS PAC - PRICE ANALOG CONTROLLER PAC - 250000-600 24VAC POWER SAT SENSOR LINKER PAC THERMOSTAT SERVICE HOT COM 1 2 3 4 5 6 7 8 L H NOTE 3: DO NOT USE GAUGE TAPS! L H CONTACT FLOW SENSOR 6 5 AIR FLOW COM CLOSE Control Sequence Number 5803 FAN POWERED DIGITAL CONTROLS R PAC DIAL STAT 250055-100 AIR FLOW SUPPLY AIR TEMPERATURE (SAT) SENSOR (OPT. - REQUIRED FOR HCCO) 250000-050 Calibration note: Suitable min and max heating flows must be selected in order to maintain flow through energized electric coils of at least 200 fpm and at least 70 cfm/kW throughout the entire operating range. LEGEND FACTORY FLOW SENSOR TUBING FACTORY ELECTRICAL WIRING FIELD ELECTRICAL WIRING CONTROL GRAPH Continuous Fan Operation Ai r Ai r ol m On Co at He ar Air Vol Max Heating Max. Cooling W Min. Heating Min. Cooling Room Set point Cool Room Condition 1 4 5 6 7 8 Warm R ENGINEER: CUSTOMER: SUBMITTAL DATE: 3 Sequence of Operation -- Constant Volume Heat/cool changeover OR cooling With up to 3 stage binary reheat - Pressure Independent On power up the damper will calibrate closed for 2 minutes. **If no SAT sensor is present, the controller assumes Cool supply air at all times** While the space is occupied, the unit fan operates continuously supplying a constant volume of supply air. Cool supply air: On an increase in space temperature the controller regulates the actuator to open the VAV damper and increase the flow of cool air. On an increase of space temperature greater than the cooling proportional band, the airflow is maintained at its pre-selected maximum setting. On a decrease in space temperature the controller regulates the actuator to close the VAV damper and reduce the flow of cool air. If the space temperature decreases to less than the cooling proportional band, the airflow is maintained at the pre-selected minimum setting. Warm supply air: On a decrease in space temperature the controller regulates the actuator to open the VAV damper and increase the flow of warm air. On a decrease of space temperature greater than the heating proportional band, the airflow is maintained at its pre-selected maximum setting. On an increase in space temperature the controller regulates the actuator to close the VAV damper and reduce the flow of warm air. If the space temperature increases above the heating proportional band, the airflow is maintained at the pre-selected minimum setting. Reheat Operation: On a decrease in space temperature into the heating proportional band, the HW valve is modulated to increase heat proportionally to room demand. PROJECT: C Copyright PRICE INDUSTRIES LIMITED 2014 2 264453 SPEC. SYMBOL: FAN POWERED PAC C.V.PRESSURE INDEPENDENT HEAT/COOL C/O OR COOLING WITHFIELD WIRED TRI-STATE HW 2014/03/14 REV 0 FAN 3 +24V HOT 1 -24V COM 2 NOTE 2: WIRES 1-4 ARE PLENUM RATED CABLES FOR 24VAC POWER AND CONTROL CIRCUITS MAX 10VA PER CONTACTOR ANALOG OUTPUT MAX: 10mA (USA) 019917-007 (CAN) 020171-001 0-10V OUT OUTPUTS SWITCHED H COM DAMPER OUT 0-10 COM OPN CLO PRICE SUPPLIED ACTUATOR COM COM CW CCW NOTE 1: TRANSFORMER SECONDARY COM MUST BE EARTH GROUNDED 3 2 1 F C 24VAC BINARY OUTPUTS PAC - PRICE ANALOG CONTROLLER PAC - 250000-600 24VAC POWER SAT SENSOR LINKER PAC THERMOSTAT SERVICE HOT COM 1 2 3 4 5 6 7 8 L H NOTE 3: DO NOT USE GAUGE TAPS! L H CONTACT FLOW SENSOR 4 AIR FLOW 0-10VDC Control Sequence Number 5804 FAN POWERED DIGITAL CONTROLS R PAC DIAL STAT 250055-100 AIR FLOW SUPPLY AIR TEMPERATURE (SAT) SENSOR (OPT. - REQUIRED FOR HCCO) 1 250000-050 Calibration note: Suitable min and max heating flows must be selected in order to maintain flow through energized electric coils of at least 200 fpm and at least 70 cfm/kW throughout the entire operating range. LEGEND FACTORY FLOW SENSOR TUBING FACTORY ELECTRICAL WIRING FIELD ELECTRICAL WIRING CONTROL GRAPH Continuous Fan Operation Max Heating Max. Cooling ol Ai r a He Co m Ai r ar Air Vol W n tO Min. Heating Min. Cooling Room Set point Cool Room Condition 5 6 7 8 Cool supply air: On an increase in space temperature the controller regulates the actuator to open the VAV damper and increase the flow of cool air. On an increase of space temperature greater than the cooling proportional band, the airflow is maintained at its pre-selected maximum setting. On a decrease in space temperature the controller regulates the actuator to close the VAV damper and reduce the flow of cool air. If the space temperature decreases to less than the cooling proportional band, the airflow is maintained at the pre-selected minimum setting. Warm supply air: On a decrease in space temperature the controller regulates the actuator to open the VAV damper and increase the flow of warm air. On a decrease of space temperature greater than the heating proportional band, the airflow is maintained at its pre-selected maximum setting. On an increase in space temperature the controller regulates the actuator to close the VAV damper and reduce the flow of warm air. If the space temperature increases above the heating proportional band, the airflow is maintained at the pre-selected minimum setting. Reheat Operation: On a decrease in space temperature, the controller modulates the 0-10VDC ouput to increase heat proportionally to the room demand. Warm R ENGINEER: CUSTOMER: SUBMITTAL DATE: 4 Sequence of Operation -- Constant Volume Heat/cool changeover OR Cooling With Analog modulating reheat - Pressure Independent On power up the damper will calibrate closed for 2 minutes. **If no SAT sensor is present, the controller assumes Cool supply air at all times** While the space is occupied, the unit fan operates continuously supplying a constant volume of supply air. PROJECT: C Copyright PRICE INDUSTRIES LIMITED 2014 2 3 264454 SPEC. SYMBOL: FAN POWERED PAC C.V.PRESSURE INDEPENDENT HEAT/COOL C/O OR COOLING WITH FIELD WIRED ANALOG HW 2014/03/14 REV 0
© Copyright 2024 Paperzz