LED lighting system for MELANO (for electricians)

Overview diagram: For electricians
LED lighting system for MELANO
*With the present document version all previous versions are no longer valid. STOBAG endeavors to continuously improve these documents. Nevertheless, no liability is
accepted for any errors which may occur and the impact there of
The regulations must be read prior to assembly. The information and instructions must be observed to prevent hazards and
damage.
The extremely energy-efficient LED lighting is impressive because of its high luminous efficiency. LED lighting can be switched on and off
using a light switch or a radio receiver. By using the optional dimmer with a 1-10V interface, the LED lighting can be infinitely dimmed.
Connection option 1: Ext. ON/OFF switch
3x1.5mm2 LNPE
(230VAC / 50Hz)
230V
On/Off
PE
L
N
230V/24V
230V
Prim
24V
Sek
1-10V
EZ601 / SL300
+
-
Connection option 2: Radio RTS / io ON/OFF
3x1.5mm2 LNPE
(230VAC / 50Hz)
Radio receiver ON/OFF
L
230V/24V
1-10V
EZ601 / SL300
N PE
PE
L
N
230V
Prim
-
24V +
Sek -
Connection option 3: Ext. Dimmer 1-10V
3x1.5mm2 LNPE
(230VAC / 50Hz)
Ext. Dimmer ON/OFF
with interface 1-10V
+
230V24V
1-10V
EZ601 / SL300
1-10V Blue DIM +
1-10V White DIM 230V
24V +
PE
L
N
Prim
Sek -
Connection option 4: Radio-Dimmer io 1-10V
3x1.5mm2 LNPE
(230VAC / 50Hz)
Radio-Dimmer io
230V24V
1-10V
EZ601 / SL300
Radio-Dimmer io
DIM DIM +
230V
IN
L
N
PE
230V
OUT
1-10V Blue DIM +
1-10V White DIM 230V
24V +
Prim
Sek -
Important: A max. of 1 network unit or network device may be connected per radio receiver.
Safety instructions: see back page
2016-01
Seite 1 von 2
Safety instructions:
Immediately after unpacking the lighting check for any damage.
If it is ascertained that safe operation cannot be guaranteed it must be taken out of service immediately and secured from
unintentional operation.
The electric installation on site must be undertaken by authorized electricians.
Set up electric connections in such a way that they are always accessible and can be switched off.
Wiring work must be performed with the power disconnected.
The stipulated protection class is only featured for undamaged and complete housing.
Local regulations must be observed.
Any disposal must be performed according to the applicable legal provisions.
.