Discontinued MAX. NUMBER OF FIXTURES: 32 MAX. DAISY CHAIN LENGTH: 300 METERS AC IN DATA INJECTOR XB.AC.2300000 CABLE A WASHER SHIELD AC XB CABLE B POWER DMX IN DATA CABLE C OUT IN IN OUT IN OUT IN AC IN voltage Total Cable length to first fixture (m) + 220 - 240V MAX. 100 METERS 3-PIN SOCKET IP66 XB.AC.2306000 END CAP IP66 XB.AC.2308000 FOR 5-PIN PLUG CABLE A SJTW 3C AWG14 (XE.IF.9999911, 100m) (UL) H07RN-F 3G 1.5mm2 (XE.IF.9999910, 100m) (CE) CABLE B and CABLE C SJTW 5C AWG14 (XE.ID.9999911, 100m) (UL) H07RN-F 5G 1.5mm2 (XE.ID.9999910, 100m) (CE) CONTINUE DMX TO NEXT CHAIN DATA INJECTOR XB.AC.2300000 100V Maximum number of fixtures per Data Injector daisy chain* Wall Washer Shield XB-18 Wall Washer Shield XB-36 5 32 32 20 32 32 100 5 32 32 32 22 20 32 21 100 5 24 32 12 19 20 30 16 100 11 4 * Cable length between fixtures: 1 meter CABLE C MAX. 100 METERS MAX. NUMBER OF FIXTURES: 32 AC IN 120V OUT MAX. DAISY CHAIN LENGTH: 300 METERS WASHER SHIELD AC XB OUT POWER DATA OUT IN IN OUT IN RJ45 END CAP IP66 MAX. 100 METERS MAX. 100 METERS OUT 5-PIN PLUG IP66 XB.AC.2302000 IN 5-PIN SOCKET IP66 XB.AC.2303000 TITLE : OUT END CAP IP66 XB.AC.2304000 FOR 5-PIN SOCKET DATE : 17/03/2011 DWG. BY : BL SCALE : NOT TO SCALE SYSTEM WIRING DIAGRAM PRODUCTS : Please check for the latest updates and changes on the TRAXON website. © TRAXON TECHNOLOGIES, 2011. ALL RIGHTS RESERVED. WWW.TRAXONTECHNOLOGIES.COM WALL WASHER SHIELD AC XB PAGE : 1 OF 1 VER : 1.0