HVC-P-S - Omron

SG-B5T-007A
в– Block Diagram
HVC-P
Host
Image Sensing Component
UART (3.3V)
HVC-P-S
B5T-001001-S (Sample) Model
CN1
Command Response
Reset
Recognition
Processing
Section
DC5V power source
Camera module
Circuit board
(customer side)
HVC-P Sample Specification Manual
в– Specifications and Functions
В© OMRON Corporation 2014 All Rights Reserved.
пЃ¬ Input Image Specifications
Item
Resolution
Horizontal detection range (angle of view)
Vertical detection range (angle of view)
в– Parts Name and Functions
пЃ¬ Front
UART 5 pin
пЃ¬ Image Sensing Functions
CN1
Function
Human
Body
Detection,
Face
Detection,
Hand
Detection
1
2
3
4
5
CN2
Face
Direction
Estimation
LED1
Gaze
Estimation
Camera module
Blink
Estimation
Age
Estimation
Gender
Estimation
Signal
Name
CN1
Connector 1
CN2
LED1
Connector 2
LED1
Function
UART signal, power switch, reset input
(cannot be used simultaneously with CN4)
Not usable
Lit when power is ON
Output
гѓ»Number of detected objects
гѓ»Position
(center coordinates)
гѓ»Size
гѓ»Degree of confidence
гѓ»Yaw angle
гѓ»Pitch angle
гѓ»Roll angle
гѓ»Degree of confidence
гѓ»Yaw angle
гѓ»Pitch angle
гѓ»Blink degree
гѓ»Age
гѓ»Degree of confidence
гѓ»Gender
гѓ»Degree of confidence
гѓ»Estimated expression
Expression
Estimation
пЃ¬ Back
гѓ»Score
гѓ»Expression degree
(positive or negative)
SW1
SW2
гѓ»Individual identification
result
OFF
Face
Recognition
ON
CN4
CN4
SW2-1
гѓ»Score
SW2-2
SW2-3
UART6 pin
4
5
6
Name
CN4
Connector 4
Description
Reserved for OMRON HVC-CONV-S conversion board.
(cannot be used simultaneously with CN1)
SW1
Tact switch
Reset input for HVC-P module board
SW2
DIP switch
Transmission rate setting of the UART signal (*1)
(*1): DIP Switch SW2 setting. The function of each bit is as follows:
SW2-1:
Fixed to ON (Please do not set it to OFF).
SW2-2 to 2-4: Used to set the transmission rate setting of the UART signal.
Transmission rate (bps)
9,600
38,400
115,200
230,400
460,800
921,600 (factory setting)
SW2-2
OFF
ON
OFF
ON
OFF
ON
SW2-3
OFF
OFF
ON
ON
OFF
OFF
Details
гѓ»Maximum of 35 per object type
гѓ»Coordinates on the screen from the top-left
corner of the screen (in pixels)
гѓ»Pixel size on the input image
гѓ»Confidence in the detection result
(0 to 1000), a higher value indicates
a higher confidence
гѓ»Positive to the right (in degrees)
гѓ»Positive upwards (in degrees)
гѓ»Positive clockwise (in degrees)
гѓ»Confidence in the estimation result
(0 to 1000), a higher value indicates
a higher confidence
гѓ»Positive to the right (in degrees)
гѓ»Positive upwards (in degrees)
гѓ»Output for both eyes (1 to 1000)
A higher value indicates the eye is
closer to being fully shut
гѓ»0 to 75 (75 includes higher ages)
гѓ»Confidence in the estimation result
(0 to 1000), a higher value indicates
a higher confidence
гѓ»Male or female
гѓ»Confidence in the estimation result
(0 to 1000), a higher value indicates
a higher confidence
гѓ»The expression with the single highest
score will be output (possible expressions
are “neutral”, “happiness”, “surprise”,
“anger” and “sadness”). The score
indicates the likeliness of a face
displaying the estimated expression,
where a higher score indicates a higher
likeliness of being that expression.
гѓ»The single highest score will be output
from 0 to 100
гѓ»+100 to -100
A degree closer to +100 indicates a high
degree of “happiness” while a degree
closer to -100 indicates a high degree of
“surprise”, “anger” or “sadness”.
гѓ»Displays the registered User ID, or
“non-registered” for non-registered
individuals
Maximum number of users: 500
Maximum number of images per user: 10
гѓ»Matching degree (the User ID of the user
with the highest matching degree is output)
пЃ¬ Basic Performance
SW2-4
1
2
3
Signal
Specifications
640 Г— 480 pixels
49 degrees
37 degrees
SW2-4
OFF
OFF
OFF
OFF
ON
ON
Function
Maximum distance (for reference)
Human Body Detection
2.8 meters
Hand Detection
1.5 meters
Face Detection, Face Direction Estimation,
Gaze Estimation, Blink Estimation,
1.3 meters
Age Estimation, Gender Estimation,
Expression Estimation, Face Recognition
Caution: Please note that the detection and estimation performance will gradually fall when
exceeding the maximum distance indicated for reference.
пЃ¬ Specifications for Signal with Host
Item
Outline
Transmission system
Transmission protocol
Synchronization system
Data format
Transmission code
Transmission speed
Specifications
Receives the command controlling the module from the host
and sends back the detection result info
Full-duplex bidirectional system
Non-procedure
Asynchronous method
Start: 1 bit, Data: 8 bit, Stop: 1 bit, no parity
NRZ, Logic Low: 0V Logic High: 3.3V
Please refer to the description of the DIP Switch SW2.
пЃ¬ Operating and Storage Environment
Item
Power supply voltage
Power consumption
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Size
Fixed value
5V В±10%
0.45 A
0 to +50В°C (no condensation or freezing)
Below 90% RH (no condensation or freezing)
-30 to +70В°C (no condensation or freezing)
Below 90% RH (no condensation or freezing)
W: 60mm Г— H: 40mm Г— D: 14.2mm
Please note that the specifications may change
as the sample is still under development
SG-B5T-007A
в– Board Dimensions
пЃ® Connector Pin Configuration
пЃ¬ Front
Please keep CN2 free of any connection.
CN4 is reserved for the OMRON HVC-CONV-S conversion board.
CN4 cannot be used simultaneously with CN1.
60
4пјЌП† 3.2
3
CN1 is used to connect to the power supply and the UART signal interface.
Connector: SM05B-SRSS-TB (made by J.S.T. Mfg. Co. Ltd.)
40
34В±0.1
3
53.5В±0.1
Recommended CN on the other end:
Housing: SHR-05V-S (made by J.S.T. Mfg. Co. Ltd.)
Contact: SSH-003T-P0.2 (made by J.S.T. Mfg. Co. Ltd.)
Pin number
1
Signal
Vcc
I/O
Input
2
UART RX
Input
3
UART TX
Output
4
GND
-
5
RESET
Input
5.4
в– Mounting
6.8
14.2
7.4
пЃ¬ Side
Description
Power supply: 5.0VВ±10%
UART signal (from host to HVC-P)
Logic 0: 0V Logic 1: 3.3V
UART signal (from HVC-P to host)
Logic 0: 0V Logic 1: 3.3V
Ground
Reset signal (from host to HVC-P)
Logic 0: 0V Logic 1: 3.3V
Reset is active on logic 1
Mounting direction (*1)
4-П†3.2 (Hole) (*2)
в– Image Input Detection Range
Vertical detection range
Vertical detection range
4-П†6 (Hatching) (*3)
Horizontal detection range
Horizontal detection range
(*1)
(*2)
в– Component Layout Dimensions
пЃ¬ Front
44.3
CN1
10.5
(*3)
П† 3.2
17
1.6
This figure is for a frontal mounting direction (0В°) of the module.
The software settings can be changed to reflect a 90В°, 180В° or 270В°
clockwise mounting direction from the front (0В°).
Please use the M3 screws to fix the board in the four corners.
Please make sure to not bend or break the board when fixing the screws.
Please make sure to also use the tightening torques provided.
Please make sure to fix the board so that it is not warped, bent or any under
unreasonable stress.
Please make sure that the board is sufficiently distanced from any
electrically-conductive part.
The П†6 (x4) hatching sections indicate the acceptable area for metallic
components.
в– Inquiries
OMRON Corporation
Electronic and Mechanical Components Company
AOC Department, HVC Customer Service
пЃ¬ Back
15.0
9.1
SW2
+81-77-565-5481
[email protected]
Hours:
9:00 to 17:00 (Japan Time Zone: UTC+09:00)
Closed on weekends, and regular and company
designated holidays.
32.3
32.8
SW1
Phone:
Email:
5.3
CN4
П† 3.2
35.9
2.54 Г— 5
пЃ¬ Camera Device
6.0
6.0
О¦ 6.0
Please note that the specifications may change
as the sample is still under development
5.4
4.6
3.5
О¦ 5.0
Please apply the glue to fix
the camera as displayed
above.