VOYAGE DATA RECORDER Model VR-3000 SIMPLIFIED VOYAGE DATA RECORDER Model VR-3000S Installation Manual SAFETY INSTRUCTIONS ............................................................................................... i EQUIPMENT LISTS........................................................................................................ ii SYSTEM CONFIGURATION ......................................................................................... iv RECORD OF PUB REV., PROG. NO.............................................................................. v 1. MOUNTING ............................................................................................................... 1 1.1 System Overview .....................................................................................................................1 1.2 Data Collecting Unit .................................................................................................................2 1.3 Data Recording Unit.................................................................................................................5 1.4 Junction Box ............................................................................................................................6 1.5 Remote Alarm Panel ................................................................................................................7 1.6 Microphone ..............................................................................................................................8 1.7 VHF Interface Unit IF-5200 (option) ....................................................................................... 12 2. WIRING.................................................................................................................... 13 2.1 System Wiring........................................................................................................................ 13 2.2 Data Collecting Unit ............................................................................................................... 14 2.3 Data Recording Unit (connecting IEEE1394 cable) ............................................................... 30 2.4 Junction Box .......................................................................................................................... 35 2.5 Remote Alarm Panel .............................................................................................................. 37 2.6 Microphone ............................................................................................................................ 38 2.7 Sensor Data ........................................................................................................................... 40 2.8 VHF Interface Unit ................................................................................................................. 44 2.9 Installation of Interface Board for Radar ................................................................................ 45 3. SETUP ..................................................................................................................... 46 3.1 VHF Interface Unit ................................................................................................................. 46 3.2 Data Collecting Unit ............................................................................................................... 47 3.3 DIP Switches in Junction Box ................................................................................................ 48 3.4 Recording Expiration Date of Parts........................................................................................ 51 3.5 System Time Adjustment ....................................................................................................... 52 PACKING LISTS..........................................................................................................A-1 OUTLINE DRAWINGS.................................................................................................D-1 INTERCONNECTION DIAGRAMS..............................................................................S-1 www.furuno.com All brand and product names are trademarks, registered trademarks or service marks of their respective holders. The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN All rights reserved. Printed in Japan A : APR . 2006 N1 : FEB . 24, 2015 Pub. No. IME-44370-N1 ( TAYA ) VR-3000/3000S 0 0 0 1 7 4 7 2 2 1 2 SAFETY INSTRUCTIONS CAUTION WARNING Turn off the power at the switchboard before beginning the installation. Observe the following compass safe distances to prevent interference to a magnetic compass: Fire or electrical shock can result if the power is left on. Do not install the equipment where it may get wet from rain or water splash. Water in the equipment can result in fire, electrical shock or damage the equipment. Standard compass (m) Steering compass (m) DCU 2.15 1.35 JB 1.65 1.05 DRU 1.10 0.65 Microphone 0.55 0.35 Waterproof Microphone 1.05 0.70 VHF I/F unit 0.75 0.50 RAP 0.85 0.55 Do not disassemble or modify the equipment. Fire, electrical shock or injury may result. Connect the power cable to correct terminals. Improper connection may result in electrical shock, fire or injury. Use the proper power supply. The rated voltage for this equipment is 24 VDC and 100-230 VAC. Use of a different power supply can damage the equipment. Attach grounding securely to ship's body. The grounding is required to prevent electrical shock. i EQUIPMENT LISTS Standard supply Name Data Collecting Unit Data Recording Unit Remote Alarm Panel Junction Box Microphone Waterproof Microphone Installation Materials Accessories Spare Parts Type Code No. Qty VR-3010 — 1 VR-5020-9G — 1 9 GB, for connection of 2-4 radars VR-3016 — 1 Includes installation materials IF-8530 VR-5011 — — 1 Option on VR-3000S VR-3012W — CP24-00605 CP24-00609 004-383-250 004-383-290 CP24-00601 004-383-210 CP24-00801 1 to 6 Remarks Choose quantity 1 For VR-3010, radar 1 to 2 CH For VR-3010, radar 3 to 4 CH For VR-3010, no radar connection. 004-384-960 1 For VR-3016 CP24-00217 CP24-00215 CP24-00910 CP24-00920 CP24-00930 004-381-090 004-379-590 000-042-241 000-042-242 000-016-261 1 1 FP24-00401 001-014-480 1 FP24-00201 FP24-00203 SP24-00201 004-383-300 004-555-560 004-555-540 1 1 1 For VR-5011 For VR-5020 IEEE1394 cable, 30m, w/armor IEEE1394 cable, 20m, w/armor IEEE1394 cable, 25m, w/armor Label for RAP, 24-009-2901 (Code No. 100-338-891-10), 1 pc English document For VR-3010 For VR-3010 1 For detailed information about installation materials, accessories and spare parts, see the packing lists at the end of this manual. ii Optional supply Name VHF Interface Unit LAN cable set Removable Hard Disk Drive Waterproof Microphone Microphone Junction Box RGBHV cable Battery Radar I/F Installation materials (for connecting radar) Radar Video Switch Interface Gland Gasket Type Code No. IF-5200 000-040-789 CP03-28900 CP03-28910 000-082-658 000-082-659 CP03-28920 000-082-660 VR-3011-A 001-173-390 Remarks To combine mic and loudspeaker lines 10 m For installation of 20 m IF-8530, w/connector MP5588-C, 30 m FR-FTPC-CY (10 m) VR-3012W VR-5011 IF-8530 BNCX5-DSUB15-L400 BNCX5-DSUB15-L700 OP24-12 RI-3010 CP24-01200 CP24-01210 IF-1000RVC OP24-16 000-041-946 000-159-595-10 000-159-596-10 004-385-010 000-010-132 Max. 3 total For connection of radar video signal, max. 4 2 sets For receiving radar video signal See Chapter 2. 000-010-133 — 001-046-260 See operator’s manual IF-1000RVC See page 34 iii SYSTEM CONFIGURATION Data Recording Unit (DRU) VR-5020-9G Waterproof MIC VR-3012W Analog (max.16ch) Bridge MIC VR-5011 Max. 6 ch VHF I/F IF-5200 Max. 2 ch VHF Audio IEC61162 Serial data Digital (max.64ch) Data Collecting Unit (DCU) VR-3010 Remote Alarm Panel (RAP) VR-3016 or Alarm Monitoring System No. 1 Radar PC Live Player V4 VR-3020 Junction Box (JB) IF-8530* Radar I/F RI-3010* 24 VDC Serial (max.8ch) Analog (max.16ch) Digital (max.64ch) Radar Video SW Interface IF-1000RVC No. 2 Radar Junction Box (JB) IF-8530 (max.2) HUB Serial (max.8ch) Serial (1ch) 100-230 VAC 24 VDC Standard supply equipment and cable Optional supply equipment and cable Local supply equipment and cable *: Optiopnal with VR-3000S GPS Speed log Echo sounder Autopilot Engine telegraph Steering gear M/E remote system Main air compressor Bow thruster Shell door system Watertight doors Fire doors Anemometer Fire detection Main alarms Others Environmental category Waterproof MIC DRU RAP Bridge MIC DCU VHF I/F unit JB Radar Video SW Interface Exposed to weather Protected from weather Note: For S-VDR, where it is impossible to obtain radar data, then AIS target data should be recorded as a source of information from other ships. (Ref. IMO Res.MSC.163(78), section 5.4.7). iv Record of PUB REV., PROG. No. Revision No., Date of Revision Program No. (software) Outline of Revision A Apr. 19, 2006 VR-3000 SYSTEM 2450031-01 RAP 2450026-01 Same as above 1st printing. A1 (For BSH) June 2, 2006 p. iv Added MIC VR-3012W to optional supply. p. v, vi Revised illustrations to show VR-3012W. p. 10, 11, 38 Added mounting and wiring procedures for VR-3012W. p. 13, 14 Revised illustrations to show VR-3012W. D-5, D-6 Added VR-3012W’s outline drawings. S-1, S-2 Added VR-3012W to interconnection diagrams. B: June 16, 2006 Same as above All pages revised. C: Aug. 21, 2006 Same as above Added cover for the beacon. D: Oct. 4 2006 Same as above Added installation material for connecting radar. E: Jan. 18, 2007 Same as above For Russian TA: added PSU-011. F: Aug. 2, 2007 Same as above For second alarm G: May 15, 2008 Same as above Added IF-1000RVC for option. H: Aug. 27, 2008 Dec. 15, 2008 VDR: 2450031-02 RAP/AP: Same as above Added OP24-16 for option. J: Mar. 14, 2010 Same as above Page 30, 31 Revised the illustration. K: Sep. 17, 2010 Same as above Page ii Changed the length of IEEE1394 cable to 20 m. Page iii Added 1394M1A1 L = 25 M. L: Dec. 10, 2010 Same as above Page ii Added IEEE1394 cable 25 m, 30 m. Page iii Deleted 1394M1A1 L=25M, 30M. M: May. 31, 2012 M1: Jul. 17, 2012 N: Apr. 12, 2013 Same as above Deleted the PSU-001. Same as above Same as above Minor change. Changed the chassis of the PCB case. v This page is intentionally left blank. vi 1. MOUNTING NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 1.1 System Overview The basic VDR consists of • Data Collecting Unit (DCU) • Data Recording Unit (DRU) in the protective capsule • Remote Alarm Panel (RAP) which indicates the status of the system remotely. • Junction Box (JB) which can minimize the cable run and increase the number of the input ports. (Optional supply with VR-3000S.) • Bridge microphone (one supplied, max. 6) • Optional VHF Interface Unit IF-5200 which combines VHF microphone and loudspeaker lines. The VDR system continuously stores data over past 12 hours in the DRU and removable hard disk. Oldest data is erased as new data is entered. The VDR operates on 100-230 VAC mains and 24 VDC power supply. In case of ship’s mains failure, backup batteries are used for recording bridge audio for 2 hours. A lot of sensors are connected to the VDR, in different signal types in some cases. Determine all sensors to be connected before installation. Note: The Data Collecting Unit, Data Recording Unit, Remote Alarm Panel and Junction Box are sometimes referred to by their acronyms. Data Collecting Unit: DCU Data Recording Unit: DRU Remote Alarm Panel: RAP Junction Box: JB 1 1.2 Data Collecting Unit The DCU is designed for on-deck or bulkhead installation, and should be mounted within the wheelhouse. Mount it in a place convenient for connection with relevant sensors and associated devices. For bulkhead mounting, be sure the mounting location is strong enough to support the weight of the unit under the vibration normally encountered onboard the vessel. Be sure to mount the DCU in an area with low humidity and away from high temperature materials, as well as an area with minimal vibration and shock. Eye bolts are provided at the top of the unit to hoist the unit onboard. Remove them after installation and plug eye bolt holes with supplied cosmetic caps. 1.2.1 General mounting considerations Mount the DCU considering the following points. • The mounting surface must be flat. If it is not flat, insert a number of washers between the unit and the mounting surface as necessary. • The mounting location should be away from places subject to water splash and rain. • Choose the location considering cable lengths, connection of relevant sensors and associated devices, access to connectors and the unit’s door. • A magnetic compass will be affected if the DCU is placed too close to a magnetic compass. Observe the compass safe distances on page ii to prevent deviation of the compass. • Observe the recommended service clearances shown in the outline drawing. 2 1.2.2 Mounting dimensions, mounting procedure Fasten the unit to the chosen location with M10 bolts or ø10 coach bolts. Bend radius 150 mm Clamping point 300 mm or more Mounting dimensions of DCU 3 1.2.3 Attaching card holder to door A card holder for convenient storage of LAN cable, IEEE1394 cable, Error code table and Data extraction procedure on the door of the DCU is available. Remove paper from double-sided tape on the card holder and attach it to the door at the location shown below, aligning bottom edge of card holder with bottom edge of door. Card holder DCU door 4 1.3 Data Recording Unit The DRU contains a protective capsule and it should be installed in the vicinity of the bridge on the open deck area of the vessel. This will maximize the probability of its survival and facilitate recovery following an incident. The DRU should be positioned clear of rigging and other potential obstructions and as near to the centerline of the ship as possible. Constructing a “fence” around the DRU is recommended. 1.3.1 Installation considerations • • • • • • Must be separated from fuel or other potential fire hazards. Must be separated from probable sources of mechanical damage. Must be separated at least 4m from VHF/MF/HF antenna. Must be installed in a place that facilitates routing maintenance and copying of recorded data. Must be installed where a diver or remote operated vehicle could remove and retrieve. There should be a clear and unobstructed area around the DRU to allow a diver or an ROV to work. 1.3.2 Fixed-type DRU Mounting The DRU comes with the mounting bracket fitted. Request shipyard to construct a mounting base for the DRU. (An example of one is shown on page 33.) On the mounting base, mount the bracket with M8 bolts and nuts (double nuts). The gap between vibration absorber and bolt should be at least 3 mm. Projection Acoustic beacon Band Gap More than 3 mm Vibration absorber Cradle Projection A A: details Note: If you once detach the main body from the mounting bracket, fix the main body as shown in the figure above so that the acoustic beacon is horizontal. Then, the main body is securely fixed by the band. How to detach the main body 1. Remove two snap pins. 2. Remove two hinge pins. 3. Lift the release levers and detach the main body. Release lever Hinge pin Snap pin 5 1.4 Junction Box The Junction Box, optionally available with the VR-3000S, provides for connection of digital, serial and analog equipment, and three units may be connected. The No. 1 JB has the following channels: Eight channels of IEC 61162 (two IEC 61162-2 and six IEC 61162-1), 64 channels of digital, and 16 channels of analog. The No. 2 and No. 3 JBs have 64 channels of digital and 16 channels of analog, respectively. 1.4.1 Mounting considerations The JB can be mounted on a bulkhead or a deck. For bulkhead mounting, be sure the mounting location is strong enough to support the weight of the unit. Mount the JB considering the following points. • Locate the unit out of sunlight and away from heat sources because of heat that can build up inside the cabinet. • The mounting location should be away from places subject to water splash and rain. • Choose the location considering cable lengths, connection of relevant sensors and associated devices, and easy access to connectors inside. • A magnetic compass will be affected if the JB is placed too close to it. Observe the compass safe distances on page i to prevent deviation of a magnetic compass. • Observe the recommended service clearances shown in the outline drawing. 1.4.2 Mounting dimensions, mounting procedure 17 12 Fasten the unit to the mounting location with M10 bolts or ø10 coach bolts. Mounting dimensions of junction box 6 1.5 Remote Alarm Panel Make sure there is a sufficient space for access to the rear cover for mounting and cabling. The Remote Alarm Panel is flush-mounted. See the outline drawing for cutout size. FIX UNIT WITH SELF-TAPPING SCREWS. SET CAPS AFTER FASTENING SCREWS. Mounting dimensions of Remote Alarm Panel Attach the IMPORTANT label (large or small one supplied in accessory) near the remote alarm panel. IMPORTANT label 24-009-2901 7 1.6 Microphone 1.6.1 Bridge microphone VR-5011 The bridge microphone comes with a flush mount plate. Fix the plate with six 4x16 self-tapping screws. The microphone covers an area about 10 m in diameter with the height of 2 m. Six microphones can cover a maximum 60 m diameter bridge area (including wings). 2m About 10 m Coverage of microphone Example of microphone at radar station Microphone mounting considerations, mounting dimensions The following consideration must be taken into account to decide the location of the microphone. • Provide clearance around it (normally overhead in the bridge) • The microphone is not waterproof, therefore do not install it on a wing. • Locate away from noise sources, such as fans, motors, and loudspeakers (1 m or more from air duct) • Mount on a non-vibrating surface to keep noise to a minimum. • Secure the cable to keep noise to a minimum. If the cable runs on an overhead without securing it, the cable will pick up noise. • Observe the compass safe distances shown on page i to prevent interference to a magnetic compass. • Microphones are mounted in the place(s) to pick up voices at the locations shown below. (Complying with IEC 61996, 4.6.5.) 1) Centerline conning 2) Bridge wings (if steering gear is installed) 3) Main radar 4) Chart table 5) Helmsstand 6) Radio room 8 Mounting dimensions of Microphone VR-5011 9 1.6.2 Waterproof microphone VR-3012W The waterproof microphone VR-3012W may be mounted on a wing, and is available in bulkhead and flush mount versions. Mounting considerations The following consideration must be taken into account to decide the location of the waterproof microphone. • Provide sufficient clearance around the unit for maintenance, etc., referring to the outline drawing. • Locate away from noise sources, such as fans, motors, and loudspeakers (1 m or more from air duct). • Mount on a non-vibrating surface to keep noise to a minimum. • Observe the compass safe distances shown on page i to prevent interference to a magnetic compass. • Secure the cable to keep noise to a minimum. If the cable runs on an overhead without securing it, the cable will pick up noise. Bulkhead mount 80±0.5 4-φ8 FIXING HOLES #150 215 13±5 195±0.5 1. Fasten the unit to the mounting location with M6 bolts or ø6coach screws. 2. See “Bulkhead mount” in paragraph 2.6.2 for wiring procedure. 100 #50 CABLE ENTRY 69 77 #50 Mounting dimensions for bulkhead mount VR-3012W 10 Flush mount 1. Prepare a cutout (120x60 mm) in the mounting location, referring to the outline drawing. 2. Dismount the microphone chassis from the case to detach MIC assy. Leave the rubber gasket attached to the MIC assy. The case may be discarded. 3. Pass wiring through the cover assy. (supplied). 4. Wire the microphone referring to paragraph 2.6. 5. Set the cover assy. to the MIC assy. and fasten with two screws. 6. Set the entire assy. to the mounting location and fasten with 12 self-tapping screws (4x16). 7. Coat area around the MIC assy. with silicone sealant to enhance waterproofing. Gasket Mounting dimensions for flush mount VR-3012W 11 1.7 VHF Interface Unit IF-5200 (option) Mounting Fix the unit using 4x20 self-tapping screws. Remove the cover to access to holes. When a non-FURUNO VHF is connected to the unit, using the terminal board, remove unused wires and connectors. Otherwise, noise problem may arise. Audio level is adjusted by DIP switches in the interface unit after installation. See paragraph 3.1. 116 ± 0.5 4- φ 5 (FIXING HOLES) NAMEPLATE 148 176 ± 0.5 217 #50 94 Mounting dimensions of VHF interface unit 12 #50 2. WIRING 2.1 System Wiring Data Recording Unit (DRU) VR-5020-9G IEEE1394 cable (20m, 25m or 30m, w/ armor) Waterproof MIC VR-3012W TTYCS-4 (max. 6 ch) Data Collecting VHF I/F Unit (DCU) IF-5200 VR-3010 TTYCS-1 (max. 2 ch) Bridge MIC VR-5011 VHF Audio No. 1 Radar *3 No. 2 Radar *3 TTYCS-4 Radar Video SW Interface IF-1000RVC PC Live Player V4 VR-3020 *3 LAN cable STP(CAT5) DPYC-2.5 Alarm Monitoring System Radar I/F RI-3010* DPYC-1.5 DPYC-1.5 TTYCS-1 x 6*1 TTYCS-1Q x 2*2 IEC61162 Serial data LAN cable STP(CAT5) 100-230 VAC 24 VDC *1: IEC 61162-1 *2: IEC 61162-2 *3: KB-HD152K or 3COX-2P-6C Cable names (Japan Industrial Standard, equivalent may be used) are shown along cable lines together with number of cables required. : Standard supply equipment and cable :Optional supply equipment and cable :Local supply equipment and cable *: Optiopnal with VR-3000S Digital (max.64ch) TTYCS-1 Remote Alarm Panel (RAP) VR-3016 HUB 3C2V or 5C2V (max. 4 ch) Radar TTYCS-4 Analog (max.16ch) TTYCS-1 Serial (1ch) Junction Box (JB) IF-8530 (max.2) or Junction Box (JB) IF-8530* DPYC-1.5 24 VDC Serial (max.8ch) TTYCS-1 x 6*1 TTYCS-1Q x 2*2 Analog (max.16ch) TTYCS-1 Digital (max.64ch) TTYCS-1 GPS Speed log Echo sounder Autopilot Engine telegraph Steering gear M/E remote system Main air compressor Bow thruster Shell door system Watertight doors Fire doors Anemometer Fire detection Main alarms Others 13 2.2 Data Collecting Unit 2.2.1 Location of connectors and terminals Radar video connectors (4) beneath this plate Side of the PCB case: J33 (KEYBOARD) J28 (VGA) J24 (RS232C) Playback/CPU SW DRU (Reserved for future use) From left: J8 (DRU) J6 (Playback) J14 (Data) From top: TB10 (MIC5) TB11 (MIC6) TB12 (VHF1) TB13 (VHF2) From left: TB3 (24VDC OUT) J10 (JB) From top: 1 TB14 (CH1* ) 1 TB15 (CH2* ) TB4 (RAP) 2 TB5 (AMS* ) Cable Clamps Lead in cables thru appropriate cable slots referring to front view of cable clamp. 1 * IEC61162-2 2 * Alarm Monitoring System From top: TB1 TB6 (MIC1) (100-230 VAC IN) TB7 (MIC2) TB2 TB8 (MIC3) (24 VDC IN) TB9 (MIC4) From top: TB16 (CH3) TB17 (CH4) TB18 (CH5) TB19 (CH6) IEC61162-1 TB20 (CH7) TB21 (CH8) Cables for MICs AMS, RAP LAN, IEEE1394 Power cables Radar video cables 14 Cables for serial equipment Connectors, terminals, etc. inside the DCU Terminals and connectors in the DCU Connector/TB Signal/Unit to be connected TB1 (100-230 VAC IN) 100-230 VAC TB2 (24 VDC IN) 24 VDC TB3 (24 VDC OUT) 24 VDC for JB TB4 (RAP) Remote Alarm Panel TB5 (AMS) Alarm Monitoring System TB6-TB11 (MIC1-MIC6) Bridge audio, 6 channels TB12-TB-13 (VHF1-VHF2) VHF audio, 2 channels TB14-TB21 (CH1-CH8) Serial data, 8 channels J6 (PLAYBACK) Play back data/PC J8 (DRU) DRU J10 (JB) JB J14 (DATA) Live Player V4 VR-3020 J24 (RS232C) PC J28 (VGA) Monitor J33 (KEYBOARD) Keyboard DRU Reserved for future use For service Refer to the interconnection diagram for details of pins on the terminal boards. Turn off the DCU before making connections. Note 1: The DCU and DRU are connected to each other with the supplied IEEE1394 (sometimes called FireWire*) cable on which two plugs are factory-fitted at both ends. These plugs look like the same but these are different; one has latches and the other does not. These are labeled “DCU” and “DRU,” so connect the cable accordingly. *FireWire is a registered trademark of the Apple Corporation. It was originally developed as a very fast external bus technology that supports data transfer rates of up to 400Mbps. Note 2: Attach cable band (supplied) to each cable to be connected to the DCU and record sensor name/equipment name on each cable band. 15 2.2.2 Working inside the unit Snap/wire assembly for keeping door of DCU open A snap/wire assembly which keeps the door of the DCU open while working inside the DCU is provided. Use it to keep the door open and prevent deformation of the door when it is opened. Attach one snap to the hole on the door and the other snap to the hole to the right of the battery handle. Note that it is not necessary to detach the assembly before closing the door. This procedure is necessary only when the unit is mounted on the deck. Attach the snap to these holes. Snap/wire assembly 16 Lead-fitting tool Radar, MIC, VHF, etc. are connected to the terminals and connectors in the DCU. The terminal board has WAGO connectors for leads of up to 2.5 mm2 or AWG 14 wires. Use the lead-fitting tool, attached inside the DCU, to fix wires to WAGO connectors, as shown in the illustration below. Lead fittting tool How to use lead-fitting tool 1) Strip sheath by 8-10 mm. 3) Tug on wires to confirm that they are securely inserted. 2) Use lead-fitting tool to open terminal and then insert wire. 17 2.2.3 Cable fabrication DPYC-1.5, DPYC-2.5 (power cables) 3 L=150 Armor Armor Sheath Sheath Cut the sheath. 50 = 11.7 mm Conductor S = 1.5 mm2 = 1.56 mm Remove paint. DPYC-1.5 cross section view Armor 15 10 6 Sheath Vinyl tape = 12.5 mm Conductor S = 2.5 mm 2 = 2.01 mm Crimp-on lug FV2-4 (supplied) 1 DPYC-2.5 cross section view Fabrication of cable type DPYC-1.5, DPYC-2.5 (or equivalent) TTYCS-1 (Serial equipment, format IEC 61162-1) L=300 Shield 50 Armor Remove paint by 50 mm. Cut vinyl sheath. Sheath Shield = 10.1 mm Expose cores, trim shield, solder ground wire to shield, attach crimp-on lug to ground wire. Conductor S = 0.75 mm 2 = 1.11 mm TTYCS-1 cross section view Vinyl tape 6 Lay this part in cable clamp. Fabrication of cable type TTYCS-1(or equivalent) 18 TTYCS-1Q (Serial equipment, format IEC 61162-2) L=300 50 Armor Shield Remove paint by 50 mm. Cut vinyl sheath. Sheath = 11.3 mm Expose cores, trim shield, solder ground wire to shield, attach crimp-on lug to ground wire. Shield Conductor S = 0.75 mm 2 = 1.11 mm TTYCS-1Q cross section view Vinyl tape 6 Lay this part in cable clamp. Fabrication of cable type TTYCS-1Q (or equivalent) TTYCS-4 (Alarm Monitoring System, MIC, RAP, analog equipment) L=300 Shield 50 Armor Remove paint by 50 mm. Cut vinyl sheath. Sheath = 16.3 mm Shield Conductor S = 0.75 mm2 = 1.11 mm Expose cores, trim shield, solder ground wire to shield, attach crimp-on lug TTYCS-4 cross section view to ground wire. 6 Vinyl tape Lay this part in cable clamp. Fabrication of cable type TTYCS-4 (or equivalent) Note: For crimp-on lugs for TTYCS cables, use those on respective terminal board. 19 How to process armor of IEEE1394 cable Ground the armor of the IEEE1394 cable by the cable clamp at the DCU. Fabricate the cable as follows. 1. Confirm the label “DCU” at the end of the cable end. (Fabricate the cable at the DCU side.) 2. Use a box cutter to cut and remove the heat-shrink tube and remove the vinyl sheath approx. 8 cm from the end of the cable. Approx. 8cm Heat-shrink tube 3. Wind the vinyl tape at the end of armor about 2 cm in width so that the end of the armor is centered on the winding. 2cm Completed state End of armor 20 2.2.4 Power supply Connect the DCU unit as follows: • AC power: Connect the ship’s mains to “100-230 VAC IN” in the DCU with cable DPYC-1.5 (or equivalent). If AC emergency source of electrical power is provided, connect it to the AC line. • DC power: If no AC emergency source of electrical power is provided, connect the ship’s battery to “24 VDC IN” (max10A battery) in the DCU with cable DPCY-2.5 (or equivalent). Observe the polarity when connecting DC source. • Junction Box: Connect the DCU to the Junction Box with cable DPYC-1.5. Main Generator VDR AC DC Emergency Generator Ship equipped with emergency AC power VDR AC Main Generator DC Battery Ship has no emergency AC power Power connections and ship’s power arrangement Power connections in the DCU Terminal TB1 (100-230 VAC IN) TB2 (24 VDC IN) TB3 (24 VDC OUT) Pin No. Signal Type 1 AC LINE 2 AC NEUT 3 AC GND 1 DC INPUT+ 2 DC INPUT- 1 DC OUTPUT+ 2 DC OUTPUT- Remarks Connect to TB1 (24 VDC IN) on JB 2.2.5 Ground Connect a ground wire (IV-8sq) between the ground terminal on the unit and ship’s grounding bus. Make the length as short as possible. CAUTION Attach grounding securely to the ship's body. The grounding is required to prevent electrical shock. 21 2.2.6 Radar RGB video Interlaced or non-interlaced radar video (4 ch max.) is connected to the video connectors on the RADAR I/F Board (optionally available with the VR-3000S) inside the DCU, with a 15-pin VGA Male to 5x BNC RGBHV cable. (Cable is supplied with VR-3000, and is available optionally with the VR-3000S.) The system supports separate sync, sync-on-green, and composite sync signals. 1) Video signal level: 0.5 to 1 Vpp (Minimum sync signal is 50 mV when a composite sync signal is used.) 2) Horizontal sync signal: Max. 91.146 kHz, positive or negative 3) Vertical sync signal: Max. 85 Hz Receivable resolution is 640 x 480 to 1280 x 1024 as shown in table below. (a) VGA: 640 x 480 (f) FR-15x5M3 series: 1024 x 780 (b) Wide VGA: 852 x 480 (g) FAR-28x5 series: 1066 x 800 (c) CCIR: 738 x 576 (h) Wide XGA: 1336 x 768 (d) SVGA: 800 x 600 (i) SXGA: 1280 x 1024 (e) Wide SVGA: 1067 x 600 (j) FR-21x5 series: 1280 x 1024 Attach connector assemblies (BNCX5-DSUB15-L400 and BNCX5-DSUB15-L7400) following the illustration on the next page. Connect coaxial cables after attaching connector assemblies. If coaxial cables are to be supplied locally, use type 3C-2V or 5C-2V. (Five cables are required.) A “single cable” (CP24-01200 or CP24-01210) for connection of radar is optionally available. Type CP24-01200 CP24-01210 22 Coaxial cable 1.5C2V-3C2V-T-20 m (20 m, 6 coaxial cores, large dia. for RGB, small dia. for HV) 1.5C2V-3C2V-T-30 m (30 m, 6 coaxial cores, large dia. for RGB, small dia. for HV) Coaxial connector 1) FB-SPM1D (BNC-P-3), 3 pcs. 2) BNC-P-1.7N, 3 pcs. 1) FB-SPM1D (BNC-P-3), 3 pcs. 2) BNC-P-1.7N, 3 pcs. Connection of radar video signal in DCU 2 4 Bind cables with cable tie. 1 3 Fix the cable with this cable clip. Cable assy. BNCX5-DSUB-L700 (length: 700 mm) Connector arrangement on RADAR I/F Board Cable assy. BNCX5-DSUB-L400 (length: 400 mm) Fix the ground wire with the screw. Tape BNC connector with vinyl insulating tape. 23 Cable arrangement in cable clamp and coaxial cable type 3C-2V coaxial cable 5C-2V coaxial cable Five coaxial cables Five coaxial cables bound with cable tie, inside and outside the DCU. 24 Attaching coaxial connector Washer Clamping nut Gasket 1) Slip clamping nut, washer and gasket onto cable. Center pin 5) Insert center pin to core and solder. 7 mm Shell 2) Strip sheath by 7 mm. 6) Screw shell into cable. 3 mm 3) Strip shield and insulator by 3 mm. Completed 4) Slide clamp onto cable and fold back shield onto clamp. 25 FAR-21x7/28x7 series radar For the connection between the VR-3000 and FAR-21x7/28x7 series radar, refer to the respective radar installation manual. FR-21x5 series radar Modify the FR-21x5 series radar as shown below to connect it to the VR-3000/VR-3000S. Parts of FR-21x5 series radar modification kit Parts Name Type Code No. Qty RGB buffer kit RGB-BUFF board NH-XH connector assy. NH-XH connector assy. OP03-162 03P9229A NH10P-XH13P NH4P-XH3P 008-501-130 1 set BNC connector converter DSUB-BNC-1 000-148-528 1 2 m RGB cable KB-HD152K 000-152-099 1 INT board RGB-BUFF board XH13P J449 RGB cable, 2m J1 BNCx5 J2 NH10P DB15 DB15 J449 XH3P J463 - J3 NH4P BNC connector converter FR -21x5 Display Unit Modification on FR-21x5 series radar 26 FAR/FR-28x5 series radar Modify the FAR/FR-28x5 series radar as shown below to connect it to the VDR. Parts of FAR/FR-28x5 series radar modification kit Parts Name VDR I/F kit (1) RGB-BUFF board NH-XH connector assy. NH-XH connector assy. VDA/INT chassis VDR I/F kit (2) (No VDA/INT chassis) BNC connector converter 2 m RGB cable Type OP03-177 03P9229A 03-2057, 4-3P 03-2058, 10-13P 03-133-1127-4 OP03-178 Code No. 008-528-270 008-528-280 DSUB-BNC-1 KB-HD152K 000-148-528 000-152-099 Qty 1 set 1 1 Kit (1): For display units being produced in June 2002 and before. Kit (2): For display units being produced in July 2002 and after. INT board J449 - 03-2058 RGB-BUFF board XH13P J1 BNCx5 NH10P J2 XH3P J463 - RGB cable, 2m DB15 DB15 J3 NH4P 03-2057 BNC connector converter FR/FAR-28x5 Display Unit Modification on FAR/FR-28x5 series radar The figure below illustrates how to mount CPA/TCPA board together with RGB buffer board in FAR/FR-28x5 series radar. VDA/INT chassis should be new type, 03-133-1127-3. CPA/TCPA board is powered from #6 (12V) and #8 (GND) of DTB-2. J463 on INT board is used for RGB board. Use 15 mm spacers. CPA/TCPA board Use 25 mm spacers. This hole is not used. VIDEO AMP New VDA/INT chassis RGB board Mounting PA/TCPA and RGB boards in FAR/FR-28x5 27 2.2.7 Alarm Monitoring System (AMS) The Alarm Monitoring System connects to TB5 in the DCU, with cable TTYCS-4 (see page 19 for cable fabrication and cable construction). Three types of signals are generated: system failure, local ACK and remote ACK. See the figure below and the two on the next page for details. System failure VR-3000/VR-3000S notifies the AMS that an alarm has been generated. Use NC port. TB5 Contact Rating Voltage: less than 32 V Current: Less than 0.2 A 1 NC NC: Normal Closed Contact 2 COM 500 ms Alarm stop System failure ON Buzzer OFF Normal condition Buzzer Alarm activated Alarm occured Alarm activated Another alarm occured ACK ACK (2nd alarm)* Buzzer stop Alarm continued *: When error code 086 or 084 occurs, system failure can not be output by 2nd alarm. Local ACK VR-3000/VR-3000S notifies the AMS that it has acknowledged system failure. TB5 Contact Rating Voltage: less than 32 V Current: Less than 0.2 A NC 4 NC 5 NO COM NC: Normal Close Contact NO: Normal Open Contact Close Open 6 NO Close Open 500 ms Local Ack Active Active interval of Local ACK signal is 500 msec ±5 msec. Local ACK signal 28 Remote ACK AMS notifies the VR-3000/VR-3000S that it has acknowledged system failure. +24 V NO 7 3.3 K + NC 8 3.3 K C C C C Active A > 150 ms Total impedance (contact and cable) shall be less than 500 ohms. NC: Normal Close Contact NO: Normal Open Contact B > 150 ms A > 150 ms Active interval A and B of Remote ACK signal shall be more than 150 msec. Chattering may be present at interval C . Choose close or open contact with S1#4 on AP MAIN board (24P0075B) ON=Normal Close OFF=Normal Open (default) Remote ACK signal S1 29 2.3 Data Recording Unit (connecting IEEE1394 cable) Connect the DRU and DCU with the IEEE1394 cable (20 m, 25 m, or 30 m). The cable is attached the connectors at both ends. The connectors are labeled “DCU” and “DRU,” respectively; do not confuse the connectors. For the IEEE1394 cable, keep in mind the following points. • • • • Do not cut the cable. If welding of cable gland or cabling support is necessary, weld BEFORE running cable. Take care not to damage shield of cable. The connector connected to the DCU must be protected from rain. If necessary, run the cable through conduit or the like. • Remove the connector cap and cap bracket from the DRU connector. How to connect the cable to the DRU DRU connector The connector cap and cap bracket are attached to the DRU connector and fixed with vinyl tape. 1. Remove vinyl tape, connector cap and cap bracket from the DRU connector perfectly. Be careful not to damage the DRU connector when removing parts. Vinyl tape, connector cap and cap bracket are removed perfectly. Cap nut Rubber bushing Teflon washer 30 The cap bracket is NOT removed. 2. Pass the cap nut, teflon washer and rubber bushing onto the cable as shown left. 3. Grease inside and outside of rubber bushing with supplied lubricant. This allows for the rubber bushing/cable and rubber bushing/DRU connections to slide easily. 4. Coat threads with lubricant to prevent scorching of threads. DO NOT coat the connector. 5. Confirm that the connector does not have a notch then connect it to receptacle on the DRU. 6. Push the cable towards the DRU then put the teflon washer and rubber bushing on to the cable. DO NOT pull the cable. The connector does not have a fastening notch to prevent it from being disconnected. 31 7. Coat the surface of the teflon washer and connecting part of the cable with supplied silicone sealant. Gap: Approx. 2.6 mm Gap: Approx. 2.6 mm approx. 1 thread Thread DO NOT OVERTIGHTEN Thread screw OR How to tighten cap nut 8. Tighten the DRU cap nut until the cap nut contacts the surface of the DRU. The cap nut is correctly tightened if approx. one thread of the cap nut is visible. Gap: Approx. 2.6 mm Gap between cap n 9. Coat the area around the cable connection and the cap nut with silicone sealant for waterproofing. 32 How to fix the DRU to the mounting base - Mounting base "A" to be supplied by shipyard. - Fix the DRU on the compass deck. - Select the location where the DRU can be easily maintained. - Locate well away from other equipment. A Loop: >30cm - Do not cut the cable even if it is too long. - Loop the cable and bind it with cable ties. Then fix the cable near the DRU but do not fix to the handle. - Fix the cable between the DRU and loop with cable ties. The radius of the loop must be more than 15 cm. Do not loop the cable around the handle of the DRU to keep the radius of the loop more than 15 cm. Fix the rocker pins. 33 How to connect the cable to the DCU Connect the cable to the DRU port J8 in the DCU and fix it with a cable tie. Using vinyl tape, tape from tip of connector to about 8 cm. Fix the cable to the support plate with the cable tie. Optional Kit The optional kit is provided for the IEEE1394 cable run through the deck. Name: Gland gasket OP24-16, Code number: 001-046-260 Name Type Code No. Qty Gasket 24-004-1503 100-347-370-10 1 Washer 24-004-1504 100-347-380-10 4 34 2.4 Junction Box Connect the junction box to the DCU before turning on the system. 2.4.1 Location of connectors Navigation device, etc. are connected to the terminals and connectors on the terminal board in the JB. The terminal board has WAGO spring-catch terminal blocks for leads of up to 2.5 mm2 or AWG 14 wires. Insert wires into holes in the connectors the same as on the terminal board in the DCU. SERIAL OUT CH1 (for additional JB) DIP SW from left: S5 (JB No.) S4 (Baud Rate) S3 (Baud Rate) S2 (Analog) S1 (Analog) DCU CH5 CH6 CH7 CH8 CH13-CH16 CH21-CH24 CH29-CH32 CH37-CH40 CH45-CH48 CH53-CH56 CH1 CH2 CH13-CH16 CH4 CH5-CH8 CH3 CH61-CH64 CH1 CH5-CH8 SERIAL CHANNELS DIGITAL CHANNELS Serial Spare LAN Spare Serial Digital Serial Analog Digital CH9-CH12 CH1-CH4 CH57-CH60 CH49-CH52 CH41-CH44 CH33-CH36 CH25-CH28 CH17-CH20 CH9-CH12 CH1-CH4 ANALOG CHANNELS DC 24V IN Power Supply Analog Location of connectors inside the junction box, where to lead in cables thru cable clamps 35 2.4.2 Cable fabrication Cable type DPYC-1.5 (power), TTYCS-1 and TTYCS-1Q (serial IEC 61162-1 and IEC 61162-2, respectively), and TTYCS-1 (analog) connect various equipment to the JB. For fabrication of those cables, see paragraph 1.1.3. 2.4.3 Ground Connect a ground wire (IV-8sq) between the ground terminal on the unit and ship’s grounding bus. CAUTION Attach grounding securely to the ship's body. The grounding is required to prevent electrical shock. 2.4.4 Connection of additional junction boxes Maximum two additional junction boxes may be installed. An additional junction box has connections for 1 serial channel (IEC 61162-1, CH3 only), 64 digital channels, and 16 analog channels. See the figure below for general wiring. When installing additional junction boxes, set junction box no. (2 and 3) with DIP SW S5. If the junction box no. of additional junction boxes is left as “1”, data will not be output from the junction box. For setting procedure, see page 50. No. 1 Junction Box (standard supply) 24 VDC Serial: 8CH Analog: 16CH Digital: 64CH LAN cable Serial CH 1 to CH8 24 VDC 172.31.24.1 Data Collecting Unit No. 1 Junction Box (standard supply) (V2.xx V1.5xx) SW HUB Data Collecting Unit Connection of one Junction Box Only CH3 (serial input) can be used with No.2 and No.3 Junction Boxes. Serial: 1CH Analog: 16CH Digital: 64CH No. 2 Junction Box Serial: 1CH Analog: 16CH Digital: 64CH No. 3 Junction Box Connection of two or three Junction Boxes 36 V1.05 and after 2.5 Remote Alarm Panel A - Clamp armor of cable. - Connect shield to shield screw on back panel. - Connect Wago connector to terminal after removing chip to avoid damage to terminal. - Spacer "A" is not necesary when space is too wide as in A above. - Tape fabricated part of cable with vinyl tape. A Wiring RAP 37 2.6 Microphone A maximum of 6 microphones can be connected, to TB6 thru TB11 in the DCU. A dual twisted, balanced cable carries the following signals: +: 24 VDC (+) A: Audio signal line, balanced, 0 dBm B: Audio signal line, balanced, 0 dBm -: 24 VDC (-) MIC1 audio is mixed with MIC2 audio, MIC3 with MIC4, and MIC5 with MIC6, respectively. CAUTION: Turn off the DCU before connecting a microphone, to prevent damage to the microphone. 2.6.1 VR-5011 - Refer to page 19 for cable fabrication. - Connect shield to screw on chassis as shown. - Tape fabricated part of cable with vinyl tape. 38 NOTICE After installing microphones, test them to make sure they are not picking up noise and that the sound quality is good. 2.6.2 VR-3012W Bulkhead mount 1. Unfasten the cover. 2. Lead in wiring through the cable gland and connect it to the terminal board on the rear side the cover, referring to the interconnection diagram. See page 19 for how to fabricate the cable. Be sure to ground shield. Tape fabricated part of wiring with vinyl tape. 3. Close the cover. Flush mount 1. Connect wiring to the terminal board on the rear side of the cover, referring to the interconnection diagram. See page 19 for how to fabricate the cable. Be sure to ground shield. Tape fabricated part of wiring with vinyl tape. 2. Fasten the cover to the housing. NOTICE After installing microphones, test them to make sure they are not picking up noise and that the sound quality is good. 39 2.7 Sensor Data Note: The serial channels in the Junction Box IF-8530 can receive the maximum of 82 characters in a sentence, consisting of a maximum of 79 characters between the starting delimiter "$" or “!” and the terminating delimiter <CR>, <LF> as defined by NMEA0183/IEC61162. 2.7.1 IEC 61162-1 serial data 12 channels are provided to receive IEC 61162-1 serial data, six in the DCU and six in the JB. Receivable are all IEC 61162 sentences and binary data, but at least ZDA is necessary for stamping date and time. Data Collecting Unit A B IEC 61162-1 interface circuit in Data Collecting Unit Junction Box A A B IEC 61162-1 interface circuit in Junction Box 40 2.7.2 IEC 61162-2 serial data 4 channels are provided to receive IEC 61162-2 serial data, two in the DCU and two in the JB. Data Collecting Unit G B A IEC 61162-2 interface circuit in Data Collecting Unit Junction Box B A G IEC 61162-2 interface circuit in Junction Box 41 2.7.3 Non-IEC 61162 signal 1) Analog 4 to 20 mA, 0 to 10 V and –10 to +10 V signals (max. 16 channels) can be connected to the ANALOG terminals in the JB. Input voltage (current) range is set by DIP switches in the junction box. Voltage signal The voltage between two input terminals is 0 to +10V or –10 to +10 V. Current signal For 4 to 20 mA current signal set jumper between I and V as shown below. Connect for current signal V 470 ohms 1/2W I G Connection of 4-20 mA current signal 2) Digital (Voltage and Contact-closure) The terminals for digital input in the JB connect voltage and contact-closure signals. Range of input voltage is 10 to 32 V. The system sends 24 VDC to ”floating contact.” The figures below show the digital interface circuit for voltage and contact-closure signals respectively. 10-32 V +24 V 2.2 K 24 2.2 K A B G Interfacing of voltage signal 42 +24 V 2.2 K 24 Jumper 2.2 K A B G Interfacing of contact-closure signal Note: Jumpers are fitted at factory between A and 24 terminals for CH1 to CH32 in order to connect contact-closure signal. To connect a voltage signal to CH1 to CH32, remove jumper by using two openers attached inside the junction box. To connect a contact-closure signal to CH33 to CH64, short between A and 24 terminals by using a jumper wire (local supply). 43 2.8 VHF Interface Unit Two VHF audio signals may be connected to the terminal board in the DCU. IMO requires one VHF audio to be recorded. A dual twisted, balanced cable carries the following signals: +: 24 VDC (+) A: Audio signal line, balanced, 0 dBm B: Audio signal line, balanced, 0 dBm -: 24 VDC (-) The VHF interface unit mixes VHF transmitting and receiving signals for the VDR. When the VHF outputs the mixed signal, this unit is not required. Specifications Power Supply: Mic input level: 24 VDC (21.6 to 31.6 VDC), 40mA -16 to –56 dBm, Input impedance: >10k ohms (Factory default: -46 dBm, 600 ohms: 10dB ATT ON) 32 to 200 ohms, 2 mW, input impedance: 10k ohms (Factory default: 2 mW, 200 ohms: 10dB ATT OFF) TTL level 0 dBm±10dB, 600 ohms, balanced Speaker input level: PTT Switch signal: Output: When a wing handset is used, the connection is made as follows. HANDSET IF-5200 FM-8700 CN3 CN1 CN2 DC24V FM10PS-6H TTYCS-1 * HANDSET VR-3000 DCU CC490, 1m CN4 WING HANDSET FM14-7P OUT1** CN7 CN5 CN6 * CC491, 1m * TTYCS-1 OUT2** TB12 TB13 CN9 * CN8 TTYC-4S WING HANDSET X2 **: OUT2 can be mixed with OUT1. *: Connect one of OUT1 or OUT2. Fix cable with a cable tie inside of the chassis. Connecting FM-8700 to DCU via interface unit IF-5200 44 2.9 Installation of Interface Board for Radar When the interface board for connection of radar(s) is not installed at the factory, install it (in the DCU) as shown below. 1. Remove ten screws shown below to detach the PCB. 2. Remove the screws shown below to remove the fixing plate. Remove this screw to remove the fixing plate. Fixing plate PCB card case 3. Connect the flat cable between the two interface boards if it is not already connected. 4. Set the boards in the PCB card case as shown below. Fix boards with screws. Set larger board in slot. 5. Fix the boards with the screws provided. 6. Reattach the fixing plate and PCB card case. 7. Connect cabling as shown on page 21-24. 45 3. SETUP This chapter describes how to set up and check the system. 3.1 VHF Interface Unit 3.1.1 Audio level adjustment DS1 and DS3 are 10 dB step attenuators for channel 1 and 2 microphone lines respectively. Set the DIP switch so that the audio output level between #4 and #5 (OUT1) and between #7 and #8 (OUT2) of CN9 is 0 dBm (2.2 Vp-p). Factory-setting: 10 dB (ON); 20 dB (OFF); 30 dB (OFF) and 40 dB (OFF). DS1 CN9 JP1 Channel 1 Input DS2 #4 #5 OUT1 #7 #8 OUT2 To VDR DS3 Channel 2 Input DS4 Location of DIP switches and jumper wire in VHF interface unit Functions of #1 and #2 segments of DS2 and DS4 Segment # of DS2 and DS4 Function #1 (10 dB ATT) Attenuates speaker signal by 10 dB. Factory-setting: OFF #2 (MIX) When set to OFF, either “mic” or “sp” signal is sent to the VDR according to the PTT switch status. When ON, both “mic” and “sp” signals are always sent to the VDR. Factory-setting: OFF 3.1.2 Jumper setting Jumper wire JP1 functions as follows: • Short circuit (Factory-setting): “Input” signals from CH1 and CH2 are output from OUT 1 port and OUT 2 port, respectively. • Open circuit: “Input” signals from CH1 and CH2 are output from OUT 1 port. 46 3.2 Data Collecting Unit The system configuration must be updated after installation. See instruction manual for VDR Maintenance Viewer and operator’s manual for Live Player V4 for the procedure. The outline of the system configuration is; Step 1: Network setting on PC Step 2: Connection of PC Step 3: Software configuration Step 4: Making a backup copy of configuration data Step 5: Software configuration from file data Step 6: Media management Step 7: Other functions 47 3.3 DIP Switches in Junction Box DIP switches in the JB are provided to set up the system according to equipment connected. The default setting for all DIP switches is “OFF”. Turn off the VR-3000/S and junction box to change the DIP switch setting. After setting the DIP switches, turn on the system to apply the settings. DIP SW from left: S5 (JB No.) S4 (Baud Rate 1) S3 (Baud Rate 2) S2 (Analog 1) S1 (Analog 2) Junction box, inside view Analog signal (DIP SW S1, DIP SW S2) Analog Signal Range Setting Channel SW No. SW Label CH1 S2-1 1 OFF ON CH2 S2-2 2 OFF ON CH3 S2-3 3 OFF ON CH4 S2-4 4 OFF ON CH5 S2-5 5 OFF ON CH6 S2-6 6 OFF ON CH7 S2-7 7 OFF ON CH8 S2-8 8 OFF ON CH9 S1-1 9 OFF ON CH10 S1-2 10 OFF ON CH11 S1-3 11 OFF ON CH12 S1-4 12 OFF ON CH13 S1-5 13 OFF ON CH14 S1-6 14 OFF ON CH15 S1-7 15 OFF ON CH16 S1-8 16 OFF ON 48 -10V to +10 V 0 V to +10 V or 4-20 mA Serial data baud rate (DIP SW S3, S4) Use for No. 1 JB (Set S5-6, S5-7, S5-8 as OFF, OFF, OFF.) Channel *1 CH1 *1 CH2 *2 CH3 *2 CH4 *2 CH5 *2 CH6 *2 CH7 *2 CH8 Serial Baud Rate Setting (bps) SW No. SW Label 4800 9600 19200 38400 S4-1 1A OFF — — ON S4-2 1B OFF — — ON S4-3 2A OFF — — ON S4-4 2B OFF — — ON S4-5 3A OFF ON OFF — S4-6 3B OFF OFF ON — S4-7 4A OFF ON OFF — S4-8 4B OFF OFF ON — S3-1 5A OFF ON OFF — S3-2 5B OFF OFF ON — S3-3 6A OFF ON OFF — S3-4 6B OFF OFF ON — S3-5 7A OFF ON OFF — S3-6 7B OFF OFF ON — S3-7 8A OFF ON OFF — 8B OFF OFF ON — S3-8 *1 *2 IEC 61162-2, IEC 61162-1 When serial out CH1 of No. 2 or No. 3 JB is connected to CH3 to CH8 of previous JB, set the CH switch for 19200 bps. Use for No.2, No. 3 JB. (Set S5-6, S5-7, S5-8 as OFF, OFF, ON or OFF, ON, OFF.) Channel *2 CH3 Serial Baud Rate Setting (bps) SW No. SW Label 4800 9600 19200 38400 S4-5 3A OFF ON — — S4-6 3B OFF OFF — — *2 IEC 61162-1 Only CH3 functions on JB No. 2 and No. 3. 49 Junction box no. setting (DIP SW S5) JB No. 1 JB DIP SW S5-6: OFF S5-7: OFF S5-8: OFF 2 S5-6: OFF S5-7: OFF S5-8: ON 3 S5-6: OFF S5-7: ON S5-8: OFF JB IP Address 172.31.24.10 S5-1: OFF S5-2: OFF S5-3: OFF S5-4: OFF 172.31.24.11 S5-1: ON S5-2: OFF S5-3: OFF S5-4: ON 172.31.24.12 S5-1: OFF S5-2: ON S5-3: OFF S5-4: ON JB NW Mode S5-5: OFF S5-5: ON S5-5: ON nd rd No. 2, No. 3 JB: Additional junction boxes (2 or 3 JB) 50 3.4 Recording Expiration Date of Parts After installing and setting up the system, record the expiration date of major parts of the system, on the sheet provided. Cut out (or copy and cut) an expiration data sheet from the ones below. For interval-specific parts record date of expiration and for general consumable parts the date of replacement. Place the card in the card holder on the inside of the door of the DCU. The expiration period starts from date of installation. Card holder Interval-specific parts Life Battery in DCU 4 years Underwater acoustic beacon in DRU 6 years General consumable parts Life Backup HDD 2 years Removable HDD (VR-3011-A) 10 years DC power fan 6 years 6 years DCU chassis fan AC power supply Interval-specific parts Date of replacement 6 years Life Battery in DCU 4 years Underwater acoustic beacon in DRU 6 years General consumable parts Life Backup HDD 2 years Removable HDD (VR-3011-A) 10 years DC power fan 6 years 6 years DCU chassis fan AC power supply Date of expiration Date of expiration Date of replacement 6 years 51 3.5 System Time Adjustment The system time, used for time-stamping VDR data, synchronizes with the UTC time if the system time is behind the UTC time within one hour. However, the system time is set to within two minutes (typically 10 seconds) behind the UTC time after installation to make the synchronization faster. 1. Connect VGA monitor and keyboard to the DCU, at the locations shown below. Inside of the DCU Side view of th PCB case Connect the VGA monitor to the VGA connector (J28). Connect the keyboard to the USB connector. DCU, door opened 2. 3. 4. 5. 6. 7. 52 Turn on the VR-3000 while pressing and holding down the F2 key. Wait for the BIOS screen to come up. (Keep the F2 key pressed.) Set the system time about 10 seconds behind UTC or GPS time. Press F10, Y, and Enter keys in order to save data. Restart VR-3000. Wait until system time synchronizes with the GPS time. NAME 004-383-290-00 CP24-00609 004-383-250-00 CP24-00605 004-555-560-00 FP24-00203 004-383-300-00 FP24-00201 004-383-310-00 FP24-00202 004-555-540-00 SP24-00201 000-042-169-00 VR-3010/3010-S-I/N ** DESCRIPTION/CODE № (*2) 1 (*2) 1 1 (*1) 1 (*1) 1 1 1 Q'TY (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 2.(*1)(*2)は、それぞれ仕様選択品を表します。 (*1)(*2)INDICATE SPECIFICATION SELECTIVE ITEM. NAME DOCUMENT OUTLINE 1/1 ** ** ** ** (*3) 1 1 1 1 (*2) 1 Q'TY TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. 24AE-X-9851 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 000-169-588-1* OMJ-44373-* 000-157-079-1* IM*-44370-* 000-157-088-1* OS*-44370-* 000-157-077-1* OM*-44370-* 004-383-210-00 CP24-00601 DESCRIPTION/CODE № 24AE-X-9851 -6 3.(*3)の取扱説明書は、サービスマンが持ち帰ります。 (*3) OPERATOR'S MANUAL SHOULD BE RETURN TO ENGINEER. OPERATOR'S MANUAL 取扱説明書(和) INSTALLATION MANUAL 装備要領書 OPERATOR'S GUIDE 操作要領書 OPERATOR'S MANUAL 取扱説明書 図書 INSTALLATION MATERIALS 工事材料 VR-3010/3010-S-I/3010-S-N 1.コ-ド番号末尾の[**]は、選択品の代表コードを表します。 CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL. INSTALLATION MATERIALS 工事材料 OUTLINE INSTALLATION MATERIALS ACCESSORIES SPARE PARTS UNIT INSTALLATION MATERIALS 工事材料 工事材料 ACCESSORIES 付属品 ACCESSORIES 付属品 ACCESSORIES 付属品 付属品 SPARE PARTS 予備品 予備品 DATA COLLECTING UNIT(DCU) データ収集ユニット ユニット PACKING LIST A-1 12'4#6145/#07#. ขᛒ⺑ᦠ ⧷ %&41/ %&41/ ⇛ޓޓ࿑ 176.+0' %1&'01 1/' %1&'01 ဳฬ㧛ⷙᩰ &'5%4+26+105 ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 C4437-F01-D 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ฬޓޓ⒓ 0#/' DATA EXTRACTION PROCEDURE データチュウシュツヨウリョウ ERROR CODE TABLE エラーコードヒョウ CARD HOLDER カードホルダー LAN CABLE ASSEMBLY LANケーブル(ブルー) CABLE ケーブル(IEEE1394) 名 称 NAME 略 図 OUTLINE 000-151-843-00 000-165-407-10 000-155-571-00 000-159-488-1* CODE NO. 000-159-489-1* C42-00408-* CODE NO. C42-00407-* CODE NO. C-26-タテ-ニ-1 000-159-485-00 C-26-タテ-ニ-1 CODE NO. ALT-03BX CODE NO. FP24-00203 1 1 1 1 1 数量 Q'TY 004-555-560-00 型名/規格 DESCRIPTIONS AIE896 TYPE CODE NO. 用途/備考 REMARKS 24AE-X-9503 -2 1/1 A-3 FURUNO ELECTRIC CO .,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) C4437-F03-C 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. 5 4 3 2 1 番 号 NO. ACCESSORIES ⇟ภ 01 #%%'5514+'5 付属品表 (2 6;2' A-2 #': ઃዻຠ %1&'01 ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 %#$.'ޓ6+' 㩄㩧㩗㩨㨹㩂㩇 %#$.'ޓ6+' 㩄㩧㩗㩨㨹㩂㩇 %15/'6+%%#2 㩘㩨㩣㩎㩁㨶㨹㩖㩩 %100'%614ޓ#55; 㩄㩒㩂㩊⚵ຠ %100'%614ޓ#55; 㩄㩒㩂㩊⚵ຠ %#$.'$#0& 㩃㨺㩖㩨㩣㩔㩨㩧㩎㩨 50#29+4'#55'/$.; 㩇㩏㨹㩖㩩㩦㨼㩞㨺㩂㩚㩕㩧 %4+/210.7) ⌕┵ሶ ฬޓޓ⒓ 0#/' ⇛ޓޓ࿑ 176.+0' %1&'01 %80 %1&'01 %80 %1&'01 %2$%+814; %1&'01 $0%:&57$. %1&'01 $0%:&57$. %1&'01 2.(// %1&'01 1#. %1&'01 (8$.7 ဳฬ㧛ⷙᩰ &'5%4+26+105 ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 C4437-M03-G 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 C4437-M02-G ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ⇟ภ 01 A-5 #': 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' %1&'01 %2$%+814; %1&'01 $0%:&57$. %1&'01 $0%:&57$. %1&'01 2.(// %1&'01 1#. %1&'01 (8$.7 %1&'01 %80 %1&'01 %80 ဳฬ㧛ⷙᩰ &'5%4+26+105 %2 ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ %15/'6+%%#2 㩘㩨㩣㩎㩁㨶㨹㩖㩩 %100'%614ޓ#55; 㩄㩒㩂㩊⚵ຠ %100'%614ޓ#55; 㩄㩒㩂㩊⚵ຠ %#$.'$#0& 㩃㨺㩖㩨㩣㩔㩨㩧㩎㩨 50#29+4'#55'/$.; 㩇㩏㨹㩖㩩㩦㨼㩞㨺㩂㩚㩕㩧 %4+/210.7) ⌕┵ሶ %#$.'ޓ6+' 㩄㩧㩗㩨㨹㩂㩇 %#$.'ޓ6+' 㩄㩧㩗㩨㨹㩂㩇 ⇛ޓޓ࿑ 176.+0' 6;2' %1&'01 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' ฬޓޓ⒓ 0#/' +056#..#6+10/#6'4+#.5 ⇟ภ 01 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ %2 6;2' A-4 #': Ꮏ᧚ᢱ %1&'01 %15/'6+%%#2 㩘㩨㩣㩎㩁㨶㨹㩖㩩 %#$.'$#0& 㩃㨺㩖㩨㩣㩔㩨㩧㩎㩨 50#29+4'#55'/$.; 㩇㩏㨹㩖㩩㩦㨼㩞㨺㩂㩚㩕㩧 %4+/210.7) ⌕┵ሶ %#$.'ޓ6+' 㩄㩧㩗㩨㨹㩂㩇 %#$.'ޓ6+' 㩄㩧㩗㩨㨹㩂㩇 ฬޓޓ⒓ 0#/' ⇛ޓޓ࿑ 176.+0' %1&'01 %2$%+814; %1&'01 2.(// %1&'01 1#. %1&'01 (8$.7 %1&'01 %80 %1&'01 %80 ဳฬ㧛ⷙᩰ &'5%4+26+105 %2 6;2' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 #': 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 C4437-M04-F 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ⇟ภ 01 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ %1&'01 A-6 0#/' &1%7/'06 36; 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 C4418-Z02-D 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 ' % %2 A-7 #$: &'5%4+26+10%1&'ͳ 84) 㪈㪅䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍဳᑼ㪆䍘䍎䍢䍼䉕䈚䉁䈜䇯 㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪜㪛㩷㪙㪰㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪫㪰㪧㪠㪚㪘㪣㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅 2#46+6+10241%'&74' 㩔㩩㨺㩍㨲㩆㨸㩧ᚻ㗅 176.+0' +056#..#6+10/#6'4+#.5 70+6 %*#0)'%10(+)74#6+10/'07 %10(+)ᄌᦝ߅㗿 ࿑ᦠ +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ Ꮏ᧚ᢱ #4'%14&'4 㩍㩨㨺㩊⸥㍳ེ ࡙࠾࠶࠻ 84)) 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 (.7+&%1/2170& 㨿㨼㩣㩄㩧㩔㩩㨽㩧㩎㩨 5+.+%10'5'#.#06 㩆㩢㩄㩧㩄㩨㩛 ฬޓޓ⒓ 0#/' ⇛ޓޓ࿑ 176.+0' %1&'01 -50 %1&'01 -'9 ဳฬ㧛ⷙᩰ &'5%4+26+105 %2 6;2' ᢙ㊂ 36; ↪ㅜ㧛⠨ 4'/#4-5 #$: 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 C4418-M02-F 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ⇟ภ 01 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ %1&'01 A-8 0#/' 176.+0' +056#..#6+10/#6'4+#.5 #%%'5514+'5 70+6 %2 (2 84 36; 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 C4437-Z02-C 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 A-9 #': &'5%4+26+10%1&'ͳ 䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ䍘䍎䍢䍼䉕䈚䉁䈜䇯 㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ Ꮏ᧚ᢱ #%%'5514+'5 ઃዻຠ ઃዻຠ 4'/16'#.#4/2#0'. 4#2 㩢㩝㨺㩎㨻㩡㨺㩛㩔㩩㩒㩣 ࡙࠾࠶࠻ 84*- 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 SELF-TAPPING SCREW +ナベタッピンネジ 1シュ CAP キャップ 名 称 NAME 略 図 OUTLINE CODE NO. 000-162-659-10 000-809-321-00 4X30 SUS304 1シュ CODE NO. 000-164-927-10 000-515-248-00 4X30 SUS304 040-3025 040-3025 型名/規格 DESCRIPTIONS 4 4 数量 Q'TY CP24-00801 TYPE 用途/備考 REMARKS 24AE-X-9401 -1 1/1 FURUNO ELECTRIC CO .,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) C4437-M01-B 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. 2 1 番 号 NO. INSTALLATION MATERIALS 工事材料表 004-384-960-00 CODE NO. A-10 0#/' 176.+0' +056#..#6+10/#6'4+#.5 70+6 %2 84 36; 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 C4418-Z04-D 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 A-11 #$: &'5%4+26+10%1&'ͳ 䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ䍘䍎䍢䍼䉕䈚䉁䈜䇯 㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅 +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ Ꮏ᧚ᢱ /+%412*10' 㩙㨼㩂㩥㩖㨵㩧 ࡙࠾࠶࠻ 8484*- 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 1シュ SELF-TAPPING SCREW +トラスタッピンネジ 名 称 NAME 略 図 OUTLINE CODE NO. 000-162-605-10 4X16 SUS304 型名/規格 DESCRIPTIONS 6 数量 Q'TY CP24-00217 TYPE 用途/備考 REMARKS 24AB-X-9405 -2 1/1 FURUNO ELECTRIC CO .,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) C4418-M05-C 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. 1 番 号 NO. INSTALLATION MATERIALS 工事材料表 004-381-090-00 CODE NO. A-12 0#/' 176.+0' +056#..#6+10/#6'4+#.5 #%%'5514+'5 70+6 59㨻㩣㩚㩋㨷㨺㩖㩨) %2 (2 (2 849 &'5%4+26+10%1&'ͳ 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 C4437-Z04-B 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 36; A-13 #': ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 5+.+%1047$$'4 㩃㩚㩆㨺㩣 Ꮏ᧚ᢱ #%%'5514+'5 ઃዻຠ ઃዻຠ 9#6'42411(/+%412*10' 㒐᳓㩙㨼㩂 ࡙࠾࠶࠻ 849 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 524+0)9#5*'4 㩔㩨㩒㩅㩨㩀㩨㩒 (.#69#5*'4 㩚㩀㩨㩁ᐔᐳ㊄ 2#0*'#&5%4'9 㩏㩗㩨ዊ㩒㩆㩨 %18'4ޓ#55; 㩀㩔㩨㨺⚵ຠ ฬޓޓ⒓ 0#/' 849 ⇛ޓޓ࿑ 176.+0' 9#6'42411(/+%412*10' %1&'01 /%9 %1&'01 /%4 %1&'01 /:%9/$0+ %1&'01 (2 ဳฬ㧛ⷙᩰ &'5%4+26+105 (2 6;2' ᢙ㊂ 36; A-14 ↪ㅜ㧛⠨ 4'/#4-5 #': 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 C4437-F05-C 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ⇟ภ 01 #%%'5514+'5 ઃዻຠ %1&'01 FUSE ヒューズ ELECTRIC CO.,LTD. FGBO 125V 10A PBF DWG. NO. OR TYPE NO. S DWG NO. PER VES 2 SPARE A-15 P 000-155-826-10 REMARKS/CODE NO. SETS PER VESSEL BOX NO. 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は 変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. 1/1 24AE-X-9301 -0 1/1 C4437-P01-A QUANTITY E WORKING PER SET U SP24-00201 004-555-540-00 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) FURUNO OUTLINE SPARE PARTS LIST FOR NAME OF PART MFR'S NAME 1 ITEM NO. SHIP NO. TYPE CODE NO. D-1 Y. Hatai D-2 Takahashi D-3 Feb.25'05 D-4 D-5 Y. Hatai Y. Hatai D-6 Y. Hatai D-7 D-8 16/May/08 R.Esumi 音声マイク (最大6台) 注記 *1)造船所手配 *2)オプション *3)切断不可 MIC4 ウイング用 FOR WING AUDIO MIC (MAX. 6 SETS) NOTE *1: SHIPYARD SUPPLY. *2: OPTION. *3: NEVER CUT THE CABLE. TTYCS-1 *1 VHF2 VHF1 DRAWN 7/Jan/2015 CHECKED 7/Jan/2015 APPROVED SCALE DWG No. *1 DPYC-1.5 C4437-C01- P J28 RED GREEN BLUE NC GND AGND(R) AGND(G) AGND(B) NC GND NC CRT_DOC_DATA H_SYNC V_SYNC CRT_DOC_CLOCK J24 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI J33 1 +5V 2 USB0- LOWER 3 USB0+ 4 GND SH FG 5 +5V 6 USB1- UPPER 7 USB1+ 8 GND SH FG J32 データ収集ユニット DATA COLLECTING UNIT VR-3010 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 AC IN TB1 1 L 2 N 3 G DC IN TB2 1 24V 2 0V GND BB+ AA+ 1 2 3 4 5 6 P P IEEE1394 P P P RADAR I/F RI-3010 BNCX5-DSUB15-L400 *1 PE IV-8sq. 保護アース REF.No. T.YAMASAKI H.MAKI MASS kg 24-009-5038-8 8/Jan/2015 H.MAKI BNCX5-DSUB15-L400 *2 BNCX5-DSUB15-L700 *2 VGA4 R 1 G 2 B 3 R_GND 6 G_GND 7 B_GND 8 SYNC_GND 10 H_SYNC 13 V_SYNC 14 15 BNCX5-DSUB15-L700 VGA RS-232C CPU BOARD USB KEYBOARD (FOR MAINTENANCE) D 各信号の接続に関しては造船所/船主との事前打合せが必要です。 CONSULT WITH SHIPOWNER AND/OR SHIPYARD ABOUT CONNECTION OF DEVICES. TITLE VR-3000 名称 航海情報記録装置 相互結線図 NAME VOYAGE DATA RECORDER INTERCONNECTION DIAGRAM V H B G R V H BNC BNC BNC または OR HUB PC (LIVE PLAYER) COAX. CABLE(x5) (*1) OR 1.5C2V-3C2V-T-20M/30M 20/30m,φ21 *2 レーダーまたはECDIS RADAR OR ECDIS COAX. CABLE(x5) (*1) OR 1.5C2V-3C2V-T-20M/30M 20/30m,φ21 *2 レーダーまたはECDIS RADAR OR ECDIS COAX. CABLE(x5) (*1) OR 1.5C2V-3C2V-T-20M/30M 20/30m,φ21 レーダーまたはECDIS RADAR OR ECDIS COAX. CABLE(x5) (*1) OR 1.5C2V-3C2V-T-20M/30M 20/30m,φ21 レーダーまたはECDIS RADAR OR ECDIS 5 B G R V H B G R V H B G R BNC TB4 TD_A TD_B RD_A RD_B GND +24V OV RJ45 J1 1 TX-P P 2 TX-N 3 RX-P 4 P P 5 6 RX-N 7 P 8 DC IN TB1 1 24V 2 0V *1 STP CABLE(CAT5) *1 STP(CAT5) ALT-03BX,3m OR STP-CAT5,CROSS(*1) *1 DPYC-1.5 1 2 3 4 5 6 7 データ記録器 DATA RECORDING UNIT VR-5020-9G アラームモニタリングシステム ALARM MONITORING SYSTEM AIE896,2m(IEEE1394) *1 TTYCS-4 *1 TTYCS-4 *3 1394M1A1 AG,20m,φ15 (25/30m:OPTION) 4 VGA3 R 1 G 2 B 3 R_GND 6 G_GND 7 B_GND 8 SYNC_GND 10 H_SYNC 13 V_SYNC 14 15 VGA1 R 1 G 2 B 3 4 5 R_GND 6 G_GND 7 B_GND 8 9 SYNC_GND 10 11 12 H_SYNC 13 V_SYNC 14 15 VGA2 R 1 G 2 B 3 R_GND 6 G_GND 7 B_GND 8 SYNC_GND 10 H_SYNC 13 V_SYNC 14 15 J10 RJ45 LAN1_BI_DA+ 1 LAN1_BI_DA- 2 LAN1_BI_DB+ 3 LAN1_BI_DC- 4 LAN1_BI_DC+ 5 LAN1_BI_DB- 6 LAN1_BI_DD+ 7 LAN1_BI_DD- 8 DC OUT TB3 24V 1 0V 2 J14 RJ45 LAN2_BI_DA+ 1 P LAN2_BI_DA- 2 LAN2_BI_DB+ 3 LAN2_BI_DC- 4 PP LAN2_BI_DC+ 5 LAN2_BI_DB- 6 LAN2_BI_DD+ 7 P LAN2_BI_DD- 8 TP TP TP TP J6 TB5 SYS_FAIL(NC) 1 SYS_FAIL(COM) 2 SYS_FAIL(NO) 3 LOCAL_ACK(NC) 4 LOCAL_ACK(COM) 5 LOCAL_ACK(NO) 6 REMOTE_ACK(+) 7 REMOTE_ACK(-) 8 P P P IEEE1394 接続箱 JUNCTION BOX IF-8530 100-230VAC 1φ,50/60Hz *1 DPYC-2.5 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 1 2 3 4 5 6 3 24VDC SERIAL CH8 IEC61162-1 SERIAL CH7 IEC61162-1 SERIAL CH6 IEC61162-1 SERIAL CH5 IEC61162-1 SERIAL CH4 IEC61162-1 SERIAL CH3 IEC61162-1 *1 TTYCS-1 *1 TTYCS-1Q *1 TTYCS-1Q *1 TTYCS-1 *1 TTYCS-1 P P P P J8 TB4 COM2 RX- 1 COM2 RX+ 2 COM2 TX- 3 COM2 TX+ 4 COM2 GND 5 +24V 6 OV 7 +24V GND TP BTP B+ TP ATP A+ 2 SERIAL CH2 IEC61162-2 SERIAL CH1 IEC61162-2 VHF INTERFACE IF-5200 VHF RECEIVER (MAX. 2 ch) VHF INTERFACE IF-5200 同上 DITTO C 1m TTYCS-1 *1 MIC6 *1 TTYCS-4 *1 TTYCS-4 P P P P B *1 TTYCS-4 *1 TTYCS-4 TB7 24V A B OV TB8 1 24V 2 A 3 B 4 OV TB9 1 24V 2 A 3 B 4 OV TB10 1 24V 2 A 3 B 4 OV TB11 1 24V 2 A 3 B 4 OV TB12 1 24V 2 A 3 B 4 OV TB13 1 24V 2 A 3 B 4 OV TB14 1 A1 2 B1 3 G1 TB15 1 A2 2 B2 3 G2 TB16 1 A 2 B TB17 1 A 2 B TB18 1 A 2 B TB19 1 A 2 B TB20 1 A 2 B TB21 1 A 2 B 1 2 3 4 TB6 24V A B OV *1 IV-8sq. VHF2 24VDC 同上 DITTO MIC3 P P P P 1 2 3 4 リモートアラームパネル REMOTE ALARM PANEL VR-3016 VHF1 24VDC 1m 同上 DITTO MIC2 *1 TTYCS-4 *1 TTYCS-4 TERMINAL BOARD(1) MIC5 同上 DITTO MIC1 1 2 3 4 5 A マイクロフォン MICROPHONE VR-5011 または OR 防水型マイク *2 WATERPROOF MIC VR-3012W 24V マイクロフォン A MICROPHONE B VR-5011 OV 1 6 S-1 注記 *1)造船所手配 *2)オプション *3)切断不可 音声マイク (最大6台) AUDIO MIC (MAX. 6 SETS) NOTE *1. SHIPYARD SUPPLY. *2. OPTION. *3. NEVER CUT THE CABLE. 1m 各信号の接続に関しては造船所/船主との事前打合せが必要です。 CONSULT WITH SHIPOWNER AND/OR SHIPYARD ABOUT CONNECTION OF DEVICES. TTYCS-1 *1 1m VHF2 VHF1 DRAWN 7/Jan/2015 CHECKED DWG No. 100-230VAC 1φ,50/60Hz *1 DPYC-1.5 7/Jan/2015 APPROVED H.MAKI SCALE MASS C4436-C01- M J28 RED GREEN BLUE NC GND AGND(R) AGND(G) AGND(B) NC GND NC CRT_DOC_DATA H_SYNC V_SYNC CRT_DOC_CLOCK J24 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI J33 1 +5V 2 USB0- LOWER 3 USB0+ 4 GND SH FG 5 +5V 6 USB1- UPPER 7 USB1+ 8 GND SH FG J32 データ収集ユニット DATA COLLECTING UNIT VR-3010 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 AC IN TB1 1 L 2 N 3 G DC IN TB2 1 24V 2 0V P P IEEE1394 J10 RJ45 LAN1_BI_DA+ 1 LAN1_BI_DA- 2 LAN1_BI_DB+ 3 LAN1_BI_DC- 4 LAN1_BI_DC+ 5 LAN1_BI_DB- 6 LAN1_BI_DD+ 7 LAN1_BI_DD- 8 DC OUT TB3 24V 1 0V 2 BNCX5-DSUB15-L400 *2 BNCX5-DSUB15-L700 *2 VGA4 R 1 G 2 B 3 R_GND 6 G_GND 7 B_GND 8 SYNC_GND 10 H_SYNC 13 V_SYNC 14 15 RADAR I/F RI-3010 *2 BNCX5-DSUB15-L700 *2 VGA3 R 1 G 2 B 3 R_GND 6 G_GND 7 B_GND 8 SYNC_GND 10 H_SYNC 13 V_SYNC 14 15 BNCX5-DSUB15-L400 *2 VGA1 R 1 G 2 B 3 4 5 R_GND 6 G_GND 7 B_GND 8 9 SYNC_GND 10 11 12 H_SYNC 13 V_SYNC 14 15 VGA2 R 1 G 2 B 3 R_GND 6 G_GND 7 B_GND 8 SYNC_GND 10 H_SYNC 13 V_SYNC 14 15 *1 PE IV-8sq. 保護アース REF.No. T.YAMASAKI kg 24-009-5038-8 VGA 8/Jan/2015 H.MAKI RS-232C V H B G R V BNC BNC COAX. CABLE(x5) (*1) OR 1.5C2V-3C2V-T-20M/30M 20/30m,φ21 *2 レーダーまたはECDIS RADAR OR ECDIS COAX. CABLE(x5) (*1) OR 1.5C2V-3C2V-T-20M/30M 20/30m,φ21 *2 レーダーまたはECDIS RADAR OR ECDIS COAX. CABLE(x5) (*1) OR 1.5C2V-3C2V-T-20M/30M 20/30m,φ21 *2 レーダーまたはECDIS RADAR OR ECDIS 5 H B G R V H B BNC COAX. CABLE(x5) (*1) OR 1.5C2V-3C2V-T-20M/30M 20/30m,φ21 *2 レーダーまたはECDIS RADAR OR ECDIS 4 G R V H B G R BNC または OR HUB PC (LIVE PLAYER) *1 RJ45 J1 STP CABLE(CAT5) 1 TX-P P 2 TX-N 3 RX-P 4 P P 5 6 RX-N 7 P 8 DC IN *1 TB1 DPYC-1.5 1 24V 2 0V *1 STP(CAT5) ALT-03BX,3m OR STP-CAT5,CROSS(*1) AIE896,2m(IEEE1394) アラームモニタリングシステム ALARM MONITORING SYSTEM 接続箱 JUNCTION BOX IF-8530 *2 *1 DPYC-2.5 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 GND BB+ AA+ 1 2 3 4 5 6 J14 RJ45 LAN2_BI_DA+ 1 P LAN2_BI_DA- 2 LAN2_BI_DB+ 3 LAN2_BI_DC- 4 PP LAN2_BI_DC+ 5 LAN2_BI_DB- 6 LAN2_BI_DD+ 7 P LAN2_BI_DD- 8 TP TP TP TP J6 P P P *1 TTYCS-4 3 24VDC SERIAL CH8 IEC61162-1 SERIAL CH7 IEC61162-1 SERIAL CH6 IEC61162-1 SERIAL CH5 IEC61162-1 SERIAL CH4 IEC61162-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1Q *1 TTYCS-1Q *1 TTYCS-1 *1 TTYCS-1 P P TB5 SYS_FAIL(NC) 1 SYS_FAIL(COM) 2 SYS_FAIL(NO) 3 LOCAL_ACK(NC) 4 LOCAL_ACK(COM) 5 LOCAL_ACK(NO) 6 REMOTE_ACK(+) 7 REMOTE_ACK(-) 8 TB4 TD_A TD_B RD_A RD_B GND +24V OV *1 TTYCS-4 1 2 3 4 5 6 7 データ記録器 DATA RECORDING UNIT VR-5020-9G *3 1394M1A1-AG 20/30m,φ15 2 SERIAL CH3 IEC61162-1 SERIAL CH2 IEC61162-2 SERIAL CH1 IEC61162-2 VHF INTERFACE IF-5200 VHF RECEIVER (MAX. 2 ch) VHF INTERFACE IF-5200 C VHF2 24VDC ウイング用 FOR WING TTYCS-1 *1 同上 DITTO P P P P P P J8 IEEE1394 +24V 1 GND 2 TP B- 3 TP B+ 4 TP A- 5 TP A+ 6 TB4 COM2 RX- 1 P COM2 RX+ 2 COM2 TX- 3 P COM2 TX+ 4 COM2 GND 5 +24V 6 P OV 7 *1 IV-8sq. VHF1 24VDC MIC6 *1 TTYCS-4 *1 TTYCS-4 *1 TTYCS-4 *1 TTYCS-4 TB7 24V A B OV TB8 1 24V 2 A 3 B 4 OV TB9 1 24V 2 A 3 B 4 OV TB10 1 24V 2 A 3 B 4 OV TB11 1 24V 2 A 3 B 4 OV TB12 1 24V 2 A 3 B 4 OV TB13 1 24V 2 A 3 B 4 OV TB14 1 A1 2 B1 3 G1 TB15 1 A2 2 B2 3 G2 TB16 1 A 2 B TB17 1 A 2 B TB18 1 A 2 B TB19 1 A 2 B TB20 1 A 2 B TB21 1 A 2 B 1 2 3 4 TB6 24V A B OV リモートアラームパネル REMOTE ALARM PANEL VR-3016 MIC5 同上 DITTO MIC4 マイクロフォン MICROPHONE VR-5011 または OR 防水型マイク *2 WATERPROOF MIC VR-3012W 同上 DITTO P P P P 1 2 3 4 B MIC3 *1 TTYCS-4 *1 TTYCS-4 TERMINAL BOARD(1) MIC2 1 2 3 4 5 A 同上 DITTO MIC1 24V マイクロフォン A MICROPHONE B VR-5011 OV 1 6 S-2 CPU BOARD USB KEYBOARD (FOR MAINTENANCE) D TITLE VR-3000S 名称 簡易型航海情報記録装置 相互結線図 NAME SIMPLIFIED VOYAGE DATA RECORDER INTERCONNECTION DIAGRAM 1 2 接続箱 JUNCTION BOX IF-8530 DIGITAL (CONTACT) *1 CH1 TTYCS-1 A CH2 CH3 CH4 CH5 CH6 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *3 *3 *3 *3 *3 *3 B CH7 CH8 CH9 CH10 C *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 *3 *3 *3 *3 *3 CH11 TTYCS-1 CH12 CH13 CH14 CH15 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *3 *3 *3 *3 D CH16 *1 TTYCS-1 *3 24P0077 RJB-TMB TB12 TB2 1 24:24V 24:24V 1 A:DIG_SIG17 2 2 A:DIG_SIG1 B:DIG_RTN17 3 3 B:DIG_RTN1 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG18 6 6 A:DIG_SIG2 B:DIG_RTN18 7 7 B:DIG_RTN2 G:GND 8 8 G:GND TB13 TB3 24:24V 1 1 24:24V A:DIG_SIG19 2 2 A:DIG_SIG3 B:DIG_RTN19 3 3 B:DIG_RTN3 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG20 6 6 A:DIG_SIG4 B:DIG_RTN20 7 7 B:DIG_RTN4 G:GND 8 8 G:GND TB14 TB4 24:24V 1 1 24:24V A:DIG_SIG21 2 2 A:DIG_SIG5 B:DIG_RTN21 3 3 B:DIG_RTN5 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG22 6 6 A:DIG_SIG6 B:DIG_RTN22 7 7 B:DIG_RTN6 G:GND 8 8 G:GND TB15 TB5 24:24V 1 1 24:24V A:DIG_SIG23 2 2 A:DIG_SIG7 B:DIG_RTN23 3 3 B:DIG_RTN7 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG24 6 6 A:DIG_SIG8 B:DIG_RTN24 7 7 B:DIG_RTN8 G:GND 8 8 G:GND TB17 TB7 24:24V 1 1 24:24V A:DIG_SIG25 2 2 A:DIG_SIG9 B:DIG_RTN25 3 3 B:DIG_RTN9 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG26 6 6 A:DIG_SIG10 B:DIG_RTN26 7 7 B:DIG_RTN10 G:GND 8 8 G:GND TB18 TB8 24:24V 1 1 24:24V A:DIG_SIG27 2 2 A:DIG_SIG11 B:DIG_RTN27 3 3 B:DIG_RTN11 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG28 6 6 A:DIG_SIG12 B:DIG_RTN28 7 7 B:DIG_RTN12 G:GND 8 8 G:GND TB9 TB19 1 24:24V 24:24V 1 A:DIG_SIG29 2 2 A:DIG_SIG13 B:DIG_RTN29 3 3 B:DIG_RTN13 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG30 6 6 A:DIG_SIG14 B:DIG_RTN30 7 7 B:DIG_RTN14 8 G:GND G:GND 8 TB10 TB20 1 24:24V 24:24V 1 A:DIG_SIG31 2 2 A:DIG_SIG15 B:DIG_RTN31 3 3 B:DIG_RTN15 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG32 6 6 A:DIG_SIG16 B:DIG_RTN32 7 7 B:DIG_RTN16 8 G:GND G:GND 8 *3 *3 *3 *3 *3 *3 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 DIGITAL (CONTACT) CH17 DIGITAL (VOLTAGE) *1 CH33 TTYCS-1 CH34 *1 TTYCS-1 CH18 CH35 CH19 *1 TTYCS-1 *1 CH36 TTYCS-1 CH20 CH37 CH21 CH38 *1 TTYCS-1 *1 TTYCS-1 CH22 *1 *3 *3 *3 *3 *3 *3 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 CH39 TTYCS-1 CH23 CH40 *1 TTYCS-1 CH24 CH41 CH25 CH42 *1 TTYCS-1 *1 TTYCS-1 CH26 CH43 CH27 CH44 *1 TTYCS-1 *1 TTYCS-1 CH28 *1 *3 *3 *1 TTYCS-1 *1 TTYCS-1 CH45 TTYCS-1 CH29 CH46 *1 TTYCS-1 CH30 *1 *3 *3 4 3 *1 TTYCS-1 *1 TTYCS-1 CH47 TTYCS-1 CH31 CH48 CH32 *1 TTYCS-1 RJB-TMB TB22 TB32 24P0077 24:24V 24:24V 1 A:DIG_SIG33 A:DIG_SIG49 2 B:DIG_RTN33 B:DIG_RTN49 3 G:GND G:GND 4 24:24V 24:24V 5 A:DIG_SIG34 A:DIG_SIG50 6 B:DIG_RTN34 B:DIG_RTN50 7 G:GND G:GND 8 TB23 TB33 24:24V 1 1 24:24V A:DIG_SIG51 2 2 A:DIG_SIG35 B:DIG_RTN51 3 3 B:DIG_RTN35 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG52 6 6 A:DIG_SIG36 B:DIG_RTN52 7 7 B:DIG_RTN36 G:GND 8 8 G:GND TB24 TB34 1 24:24V 24V 1 A:DIG_SIG53 2 2 A:DIG_SIG37 B:DIG_RTN53 3 3 B:DIG_RTN37 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG54 6 6 A:DIG_SIG38 B:DIG_RTN54 7 7 B:DIG_RTN38 G:GND 8 8 G:GND TB25 TB35 24:24V 1 1 24:24V A:DIG_SIG55 2 2 A:DIG_SIG39 B:DIG_RTN55 3 3 B:DIG_RTN39 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG56 6 6 A:DIG_SIG40 B:DIG_RTN56 7 7 B:DIG_RTN40 G:GND 8 8 G:GND TB27 TB37 1 24:24V 24:24V 1 A:DIG_SIG57 2 2 A:DIG_SIG41 B:DIG_RTN57 3 3 B:DIG_RTN41 G:GND 4 4 G:GND 24:24V 5 5 24:24V 6 A:DIG_SIG42 A:DIG_SIG58 6 7 B:DIG_RTN42 B:DIG_RTN58 7 8 G:GND G:GND 8 TB28 TB38 1 24:24V 24:24V 1 A:DIG_SIG59 2 2 A:DIG_SIG43 B:DIG_RTN59 3 3 B:DIG_RTN43 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG60 6 6 A:DIG_SIG44 B:DIG_RTN60 7 7 B:DIG_RTN44 8 G:GND G:GND 8 TB39 TB29 1 24:24V 24:24V 1 A:DIG_SIG61 2 2 A:DIG_SIG45 B:DIG_RTN61 3 3 B:DIG_RTN45 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG62 6 6 A:DIG_SIG46 B:DIG_RTN62 7 7 B:DIG_RTN46 G:GND 8 8 G:GND TB30 TB40 1 24:24V 24:24V 1 A:DIG_SIG63 2 2 A:DIG_SIG47 B:DIG_RTN63 3 3 B:DIG_RTN47 G:GND 4 4 G:GND 24:24V 5 5 24:24V A:DIG_SIG64 6 6 A:DIG_SIG48 B:DIG_RTN64 7 7 B:DIG_RTN48 8 G:GND G:GND 8 *1 TTYCS-1 1 2 3 4 5 6 7 8 *1 TTYCS-1 *1 TTYCS-1 5 DIGITAL (VOLTAGE) SERIAL IEC61162-1/2 CH49 CONSULT WITH SHIPOWNER AND/OR SHIPYARD ABOUT CONNECTION OF DEVICES. NOTE *1: SHIPYARD SUPPLY. *2: SET JUMPER BETWEEN I AND V FOR 4-20mA SIGNAL. *3: JUMPER SET BETWEEN 24V AND A-TERMINAL AT FACTORY. MODIFY SETTING TO CONNECT A VOLTAGE LINE. CH2 CH50 SERIAL IEC61162-1 CH3 CH51 CH4 *1 TTYCS-1 *1 TTYCS-1 CH52 CH5 CH6 CH53 CH7 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 CH54 CH8 *1 TTYCS-1Q *1 TTYCS-1Q *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 TB45 1 A:SER_A1 2 B:SER_B1 3 G:SER_ISOGND1 TB50 1 A:SER_A2 2 B:SER_B2 3 G:SER_ISOGND2 TB11 1 A:SER_A3 2 B:SER_B3 TB16 1 A:SER_A4 2 B:SER_B4 TB21 1 A:SER_A5 2 B:SER_B5 TB26 1 A:SER_A6 2 B:SER_B6 TB31 1 A:SER_A7 2 B:SER_B7 TB36 1 A:SER_A8 2 B:SER_B8 TB6 1 SER_OUT_A 2 SER_OUT_B 3 4 CH55 CH56 CH57 CH58 CH59 CH60 CH61 RJB-TMB 24P0077 CH62 TB41 V:AN_SIG1 1 I:470ohm1 2 G:AN_RTN1 3 V:AN_SIG2 4 I:470ohm2 5 G:AN_RTN2 6 TB42 V:AN_SIG3 1 I:470ohm3 2 G:AN_RTN3 3 V:AN_SIG4 4 I:470ohm4 5 G:AN_RTN4 6 TB43 V:AN_SIG5 1 I:470ohm5 2 G:AN_RTN5 3 V:AN_SIG6 4 I:470ohm6 5 G:AN_RTN6 6 TB44 V:AN_SIG7 1 I:470ohm7 2 G:AN_RTN7 3 V:AN_SIG8 4 I:470ohm8 5 G:AN_RTN8 6 TB46 V:AN_SIG9 1 I:470ohm9 2 G:AN_RTN9 3 V:AN_SIG10 4 I:470ohm10 5 G:AN_RTN10 6 TB47 V:AN_SIG11 1 I:470ohm11 2 G:AN_RTN11 3 V:AN_SIG12 4 I:470ohm12 5 G:AN_RTN12 6 TB48 V:AN_SIG13 1 I:470ohm13 2 G:AN_RTN13 3 V:AN_SIG14 4 I:470ohm14 5 G:AN_RTN14 6 TB49 V:AN_SIG15 1 I:470ohm15 2 G:AN_RTN15 3 V:AN_SIG16 4 I:470ohm16 5 G:AN_RTN16 6 TB1 24V 1 OV 2 J1 TX-P TX-N RX-P CH63 RX-N *1 TTYCS-1 RJB-MAIN 24P0069 CH64 *1 TTYCS-1 *2 *1 TTYCS-1 ANALOG CH1 CH2 *2 *1 TTYCS-1 *2 *1 TTYCS-1 CH3 CH4 *2 *1 TTYCS-1 *2 *1 TTYCS-1 CH5 CH6 *2 *1 TTYCS-1 *2 *1 TTYCS-1 CH7 CH8 *2 *1 TTYCS-1 *2 *1 TTYCS-1 CH9 CH10 *2 *1 TTYCS-1 *2 *1 TTYCS-1 CH11 CH12 *2 *1 TTYCS-1 *2 *1 TTYCS-1 CH13 CH14 *2 *1 TTYCS-1 *2 *1 TTYCS-1 CH15 CH16 *2 *1 DPYC-1.5 *1 RJ45 STP(CAT5) RJ45 1 2 3 4 5 6 7 8 P P P P 24VDC HUB OR DCU 1 2 3 4 5 6 7 8 *1 IV-8sq. DRAWN 各信号の接続に関しては造船所/船主との事前打合せが必要です。 注記 *1)造船所手配。 *2)入力信号が4-20mAの場合はV-I間をショートすること。 *3)接点信号接続用に24V-A端子間にジャンパー取付済。 電圧信号接続時は設定を変更する。 CH1 S-3 6 18/Jun/2014 CHECKED 18/Jun/2014 APPROVED T.YAMASAKI H.MAKI MASS kg DWG No. C4437-C02- K IF-8530 名称 接続箱 相互結線図 NAME JUNCTION BOX INTERCONNECTION DIAGRAM VR-7000 VR-3000/3000S 19/Jun/2014 H.MAKI SCALE TITLE REF.No. TX-P(DA+) TX-N(DA-) RX-P(DB+) RX-N(DB-) S-4 1 2 3 A VHFインターフェイス VHF INTERFACE IF-5200 *2 FM10PS-6H ハンドセットハンガー HANDSET HANGER HSC701K-B20 マイクレセプタクル ボックス MIC RECEPTACLE BOX RBD-VHF/VHF-B No.1 B 1 2 3 4 5 6 1 2 3 *1 TTYCY-4S P P 4 CN3 0V PTT SW MIC-H MIC-C SP(H) THRU1 CN4 0V PTT SW MIC-H MIC-C SP(H) THRU1 THRU2 0V 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CN7/8 CN5 0V 0V PTT SW PTT SW MIC-H MIC-H MIC-C MIC-C SP(H) SP(H) THRU1 THRU1 THRU2 THRU2 0V 0V 1 2 3 4 5 6 7 8 CN6 CN9 0V 24VDC(+) 1 PTT SW 24VDC(-) 2 MIC-H 3 MIC-C OUT1(H) 4 OUT1(L) 5 SP(H) 6 THRU1 OUT2(H) 7 THRU2 OUT2(L) 8 0V 1 2 3 4 5 6 7 8 *2 NH8P 付属ケーブル ATTACHED CABLE CC490,1m *2 NH8P 付属ケーブル ATTACHED CABLE CC491,1m VHF送受信機 VHF TRANSCEIVER UNIT FM-8500 HANDSET *2 FM10PS-6H J1105 1 0V 2 PTT SW 3 MIC-H 4 MIC-C 5 HS SP 6 HOOK SW *2 FM14-7P 1 2 3 4 5 6 7 WING HANDSET J602 0V W_PTT SW W_MIC W_SP TX/RX +15V 0V ウイングハンドセット WING HANDSET *3 HS6000FZ-6/5 マイクレセプタクル ボックス MIC RECEPTACLE BOX RBD-VHF/VHF-B No.2 1 2 3 *1 TTYCY-4S P P 4 C ウイングハンドセット WING HANDSET *3 HS6000FZ-6/5 *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 24VDC VHF-1 L+ LVHF-2 L+ L- VR-5000 データ収録ユニット DATA COLLECTING UNIT VR-5010 TB-12 2 A 3 B TB-13 2 A 3 B VR-3000/3000S データ収録ユニット DATA COLLECTING UNIT VR-3010 注記 *1)造船所手配。 *2)工場にて取付済み。 *3)1台のウイングハンドセットを共用する。 D NOTE *1. SHIPYARD SUPPLY. *2. FITTED AT FACTORY. *3. ONE WING HANDSET IS USED IN COMMON. DRAWN MAY 23, '06 CHECKED APPROVED SCALE DWG.No. TITLE E.MIYOSHI TAKAHASHI.T 名称 Y. Hatai MASS C4418-C02- J kg NAME IF-5200 (W/FM-8500) VHFインターフェイス 相互結線図 VHF INTERFACE INTERCONNECTION DIAGRAM S-5 1 2 3 VHF送受信機 VHF RADIO FM-8700 A VHFインターフェイス VHF INTERFACE IF-5200 *2 FM10PS-6H ハンドセットハンガー HANDSET HANGER HSC701K-B20 マイクレセプタクル ボックス MIC RECEPTACLE BOX RBD-VHF/VHF-B No.1 B 1 2 3 4 5 6 1 2 3 *1 TTYCY-4S P P 4 CN3 0V PTT SW MIC-H MIC-C SP(H) THRU1 1 2 3 4 5 6 7 8 ウイングハンドセット WING HANDSET *3 HS6000FZ-6/5 マイクレセプタクル ボックス MIC RECEPTACLE BOX RBD-VHF/VHF-B No.2 1 2 3 4 C *1 TTYCY-4S P P 1 2 3 4 5 6 7 8 CN4 0V PTT SW MIC-H MIC-C SP(H) THRU1 THRU2 0V CN5 0V PTT SW CN7/8 MIC-H MIC-C 0V SP(H) PTT SW MIC-H THRU1 MIC-C THRU2 SP(H) 0V THRU1 THRU2 0V 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CN6 CN9 0V 24VDC(+) 1 PTT SW 24VDC(-) 2 MIC-H 3 MIC-C OUT1(H) 4 OUT1(L) 5 SP(H) 6 THRU1 OUT2(H) 7 THRU2 OUT2(L) 8 0V ウイングハンドセット WING HANDSET *3 HS6000FZ-6/5 *2 NH8P *2 NH8P 送受信部 TRANSCEIVER UNIT FM-8700 付属ケーブル HANDSET *2 ATTACHED CABLE FM10PS-6H J1105 CC490,1m 1 0V 2 PTT SW 3 MIC-H 4 MIC-C 5 HS SP 6 HOOK SW 付属ケーブル ATTACHED CABLE CC491,1m クロ BLK ミドリ GRN アカ RED アオ BLU シロ WHT *1 TTYCS-1 *1 TTYCS-1 *1 TTYCS-1 デュプレクサユニット DUPLEXER UNIT DX-8700 WING HANDSET TB201 0V W_PTT SW W_MIC W_SP F_GND *4 1 2 3 4 5 24VDC VHF-1 L+ LVHF-2 L+ L- VR-5000 データ収録ユニット DATA COLLECTING UNIT VR-5010 TB-12 2 A 3 B TB-13 2 A 3 B VR-3000/3000S データ収録ユニット DATA COLLECTING UNIT VR-3010 注記 *1)造船所手配。 *2)工場にて取付済み。 *3)1台のウイングハンドセットを共用する。 *4)コネクタプラグを取り外して結線する。 D NOTE *1. SHIPYARD SUPPLY. *2. FITTED AT FACTORY. *3. ONE WING HANDSET IS USED IN COMMON. *4. CONNECT CORES AFTER REMOVE CONNECTOR PLUG. DRAWN Jun. 26,'06 CHECKED APPROVED SCALE DWG.No. TITLE E.MIYOSHI TAKAHASHI.T 名称 Y.Hatai MASS C4418-C03- K kg NAME IF-5200 (W/FM-8700) VHFインターフェイス 相互結線図 VHF INTERFACE INTERCONNECTION DIAGRAM S-6 1 2 3 レーダー映像自動切換器 RADAR VIDEO SWITCH INTERFACE IF-1000RVC A 100-230VAC 1φ,50-60Hz RADAR 1 RADAR 2 OUT1 BNC *1 DPYC-1.5 TB1 1 L 2 N J9 BNC J10 BNC J11 BNC J12 BNC J13 BNC OUT2 BNC J14 R BNC J15 BNC J16 BNC J17 BNC J18 BNC R *3 G *1 TTYCS-1 *1 TTYCS-1 1 2 3 4 TB2 TRG1 GND TRG2 GND B H RADAR 1 B Dsub15P IN1 KB-HD152K,2m *2 J5 3COX-2P-6C,5/10m,φ8.5 (mini) R 1 OR VGA CABLE *1 GND 6 G 2 GND 7 B 3 GND 8 NC 4 NC 9 NC 5 GND 10 H 13 GND 11 V 14 NC 12 15 NC V G B H V RADAR 2 Dsub15P KB-HD152K,2m *2 3COX-2P-6C,5/10m,φ8.5 (mini) OR VGA CABLE *1 J6 IN2 OUT1 J7 同上 DITTO OUT2 C J8 *2 1.5C2V-3C2V-T-20M/30M, VDR/S-VDR 20/30m,φ21 OR COAX.CABLE(x5) *1 *2 1.5C2V-3C2V-T-20M/30M, VDR/S-VDR 20/30m,φ21 OR COAX.CABLE(x5) *1 Dsub15P (mini) KB-HD152K,2m *2 3COX-2P-6C,5/10m,φ8.5 OR VGA CABLE *1 VDR/S-VDR Dsub15P (mini) KB-HD152K,2m *2 3COX-2P-6C,5/10m,φ8.5 OR VGA CABLE *1 VDR/S-VDR PE *1 IV-2sq. D 注記 *1)造船所手配。 *2)オプション。 *3)出力はBNCまたはDsubのいずれかを選択。(内部設定) NOTE *1: SHIPYARD SUPPLY. *2: OPTION. *3: SELECT BNC OR D-SUB OUTPUT.(MODIFY INNER SETTING) DRAWN CHECKED APPROVED SCALE DWG.No. 8/May/08 8/May/08 TITLE T.YAMASAKI 名称 T.TAKENO 16/May/08 R.Esumi VR-5000/3000 MASS C4418-C06- A NAME kg REF.No. 24-009-5050-0 IF-1000RVC レーダー映像自動切換器 相互結線図 RADAR VIDEO SWITCH INTERFACE INTERCONNECTION DIAGRAM
© Copyright 2024 Paperzz