GigaLine ® KL-A-DF(ZN)(L)2Y - LEONI Kerpen GmbH – Stolberg

GigaLine ® KL-A-DF(ZN)(L)2Y
Fibre optic outdoor cable, multi tube, longitudinally and
latitudinally watertight, multi-layer sheath
Type
KL-A-DF(ZN)(L)2Y n x m G/E
Construction:
1)
Fibre:
single mode fibre E9..10/125 µm
multi mode fibre G50/125 µm
multi mode fibre G62.5/125µm
Colour code:
DIN VDE 0888-3 red, green, blue, white, grey, brown, violet,
turquoise, black, orange, pink
2)
Core:
jelly-filled loose tube Ø 2.4mm
Colour code:
Colour code loose tubes: 1st tube red, 2nd white, others yellow
(9/125), green (50/125) or blue (62,5/125)
3)
Central dielectric strength member (FRP)
stranded, jelly-filled loose tube
4)
Strain-relief
aramid yarns/glass rovings
5)
Multi-layer sheath:
aluminium foil bonded with the PE sheath
INDUSTRY 6)
Sheath:
PE, sunlight resistant
Colour outer sheath:
Jet black RAL-9005
Fibre quality:
0,36F3,5/0,22H18; E9..10 low OH, OS2
3.0B250/0.7F800-GBE500/1000; G62.5/125 OM1e
2,5B600/0,7F1200-GBE750/2000; G50/125 OM2e
2.5B1500/0.7F500-10GBE300; G50/125 OM3 bendable
2,5B4700/0,7F500 10GBE550; G50/125 OM4 bendable
Halogen acid gas emission:
IEC 60754-1
Impact:
IEC 60794-1-2 E4
Bending:
IEC 60794-1-2 E11
Chemical continuance:
Printing Inkjet:
LEONI GigaLine $fibre type$ $core type$ ~~ $lot number$ $meter
mark$
Free of hazardous substances acc. to RoHS 2002/95/EG
Temperature test:
IEC 60794-1-2, method F1
Strain-relief elements:
Temperature range
Transport and storage -25°C to +70°C
During installation -5°C to +50°C
After installation -40°C to +60°C
IEC 60794-1-2, method E1
Crush:
IEC 60794-1-2, method E3
Bending radius
After installation: 30 mm
During installation: 60 mm
For single element: 30 mm
LEONI Kerpen GmbH Zweifaller Str. 275-287 D-52224 Stolberg, Tel. +49(0)2402-17-1, Fax +49(0)2402-75154,
Email [email protected], www.leoni-infrastructure-datacom.com
Valid except for misprints and errors. Technical values subject to change (without notice).
The original document is in German language. In case of doubt or conflict, the German language version will prevail.
GigaLine ® KL-A-DF(ZN)(L)2Y
Fibre optic outdoor cable, multi tube, longitudinally and
latitudinally watertight, multi-layer sheath
Type
KL-A-DF(ZN)(L)2Y n x m G/E
Application:
Outdoor cable for laying directly in the ground or in conduits and in case of high risk of damage by rodents, for MAN (city
networks) and LAN ( campus/backbone). For installation in generic cabling acc. to ISO/IEC 11801, ISO/IEC 24702, EN
50173-1 and EN 50173-3.
Ideal for all applications of Classes OF 300 to OF 10000 (depending on the fiber).
Suitable for splicing
Installation:
Outdoor, in conduits or on covered cable trays. For automated cable pulling via cable winches the use of tensile-forcerecording equipment is obligatory.
Dimensions: Outer-Ø:
Weight:
Strain-rel
ief elements:
mm (ca.) kg/km (approx.)
N (max.)
Crush resistance:
Calorific value:
Long term
Short term
MJ / m kWh / m
N / dm (max.) N / dm (max.) (approx.) (approx.)
2x12
12,1
140
3000
1500
3000
4,97
8x12
14,4
200
4000
1500
3000
5,87
1,63
12x12
17,7
300
4000
1500
3000
7,24
2,01
INDUSTRY
Dimensions: GBE 750/2000 OM2e
G50/125
Low OH OS2
E9...10/125
10GBE300 OM3 bendable
G50/125
2x12
LKD8AA204060000
*
LKD8AA504060000
8x12
*
LKD8AC704110000
*
12x12
*
LKD8AC704130000
*
* on request
1,38